Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
In that case, you need to install repeater. When you continue to press the call button of transmitter over two seconds, transmission will be automatically cut off, preventing battery from running out. In addition, BBT-100 sets up magnetic sensor or external switch . Wait for 5 seconds Select receiver sound No.1 Wait for 10 seconds Select receiver sound No.2 Wait for 15 seconds Wait for 20 seconds In the case of common use of cable and radio re p eater In receivin g with antenna of receiver In usin g cable re p eater
BWS TECH Inc. 1 of 1 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 Appendix 5. Block Diagram External Controll DIP_SW1,2 Number / Channel Signal Source Encoder U1 Frequency Generator SAW345.0M Amp / Mixer Q1 RF Amp Q2 RF Out Power ANTENA Power SW1
BWS TECH Inc. 1 of 1 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 Appendix 3. External Photographs of EUT Front of EUT Rear of EUT
BWS TECH Inc. 1 of 1 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 Appendix 2. FCC ID Label and location Product Label Sample with FCC ID Label information Following is a sample copy of the label that will be placed on the rear cabinet of the product. The FCC identifier is marked in the product label. The warning statement and information to the user are described in the user manual. Label Location The label shown above shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase.(Labeling requirements per 2.925) XTM Solution Wireless Calling Bell System Model : BBT-100 FCC ID : SDIBBT-100 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC LABEL Solution
BWS TECH Inc. 1 of 2 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 Appendix 4. Internal Photographs of EUT BWS TECH Inc. 2 of 2 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 Front of EUT (Internal) Rear of EUT (Internal)
In that case, you need to install repeater. When y ou continue to p ress the call button of transmitter over two seconds, transmission will be automatically cut off, preventing battery from running out.
BWS TECH Inc. 1 of 1 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 Appendix 6. Schematic
BWS TECH Inc. 1 of 16 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 Electromagnetic Emission FCC MEASUREMENT REPORT FCC PART 15 SUBPART C FOR LOW POEWR TRANSMITTER PRODUCT : Wireless Calling Bell Transmitter MODEL/TYPE NO : BBT-100 FCC ID : SDIBBT-100 TRADE NAME : XTM Solution APPLICANT : XTM Solution Heacheon Bldg., 741-40, Yeoksam-dong, Gangnam-Ku, Seoul, 135-936, Korea Attn. : Kyeong-Rok Kang / President FCC CLASSIFICATION : DSC- Part 15 RF Control/Security device Transmitter FCC RULE PART(S) : FCC Part 15 Subpart C Section 15.231 FCC PROCEDURE : Certification DATES OF TEST : July 12, 2004 DATES OF ISSUE : July 22, 2004 TEST REPORT No. : BWS-04-RF-0016 TEST LAB. : BWS Tech., Inc. (Registration No. : 553281) This RF Keyless entry system has been tested in accordance with the measurement procedures specified in ANSI C63.4-2000 at the BWS TECH/EMC Test Laboratory and has been shown to be complied with the electromagnetic radiated emission limits specified in FCC Rule Part15 Subpart C Section15.231 I attest to the accuracy of data. All measurement herein was performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. The results of testing in this report apply to the product/system, which was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. TaeHyun Nam Chief of Laboratory Division BWS TECH Inc. BWS TECH Inc. www.bws.co.kr 294-9, Jungdae-Dong, Kwangju-Si, Kyunggi-Do, 464-080, Korea TEL: +82 31 762 0124 FAX: +82 31 762 0126 BWS TECH Inc. www.bws.co.kr 294-7, Jungdae-Dong, Kwangju-Si, Kyunggi-Do, 464-080, Korea TEL: +82 31 764 0125 FAX: +82 31 764 0126 BWS TECH Inc. 2 of 16 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 TABLE OF CONTENTS Pages 1. General Information 3 2. Description of Test Facility 4 3. Product Information 5 4. Description of Tests 6~7 5. Test Condition 8 6. Test Results 9~14 7. Sample Calculation and Other Information 15 8. Test Equipment List 16 Appendix 1. Test Setup Photos Appendix 2. FCC ID Label and location Appendix 3. External Photos of EUT Appendix 4. Internal Photos of EUT Appendix 5. Block Diagram Appendix 6. Schematics Appendix 7. Operational Description Appendix 8. User Manual BWS TECH Inc. 3 of 16 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 FCC TEST REPORT Scope β Measurement and determination of electromagnetic emission(EME) of radio frequency devices including intentional radiators and/or unintentional radiators for compliance with the technical rules and regulations of the U.S Federal Communications Commission(FCC) 1. General Information Applicant Manufacturer z EUT Type : Wireless Calling Bell Transmitter z Model Number : BBT-100 z FCC Identifier : SDIBBT-100 z S/N : Prototype z Freq. Range : 345 MHz z Channel : 1 ch z Modulation Method : ASK z FCC Rule Part(s) : Part 15 Subpart C Section 15.231 z Test Procedure : ANSI C63.4-2000 z Dates of Tests : July 12, 2004 z Place of Tests : BWS TECH Inc. EMC Testing Lab (FCC Registration Number : 553281) 294-9, Jungdae-Dong, Kwangju-Si, Kyunggi-Do, 464-080, Korea TEL: +82 31 762 0124 FAX: +82 31 762 0126 z Test Report No. zBWS-04-RF-0016 Company Name : XTM Solution Company Address : Heacheon Bldg., 741-40, Yeoksam-dong, Gangnam-Ku, Seoul, 135-936, Korea Phone/Fax : Phone : +82-2-3467-5600 Fax : +82-2-3467-4419 Company Name : XTM Solution Company Address : Heacheon Bldg., 741-40, Yeoksam-dong, Gangnam-Ku, Seoul, 135-936, Korea Phone/Fax : Phone : +82-2-3467-5600 Fax : +82-2-558-4419 BWS TECH Inc. 4 of 16 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 2. Description of Test Facility The measurement for radiated emission test were practiced at the open area test site of BWS TECH Inc. Measurement for conducted emission test were practiced at the semi EMC Anechoic Chamber test site of BWS TECH Inc. facility located at 294-9, Jungdae-Dong, Kwangju-Si, Kyunggi-Do, Korea. The site is constructed in conformance with the requirements of the ANSI C63.4-2000 and CISPR Publication 16. The BWS TECH measurement facility has been filed to the Commission with the FCC for 3 and 10-meter site configurations. Detailed description of test facility was found to be in compliance with the requirements of Section 2.948 FCC Rules according to the ANSI C63.4-1992 and registered to the Federal Communications Commission (Registration Number : 553281 ). The measurement procedure described in American National Standard for Method of Measurement of Radio-Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz (ANSI C.63.4-2000) was used in determining radiated emissions from the Drake Systems Co., Ltd.. RF keyless entry system Model : DTH-9000B. BWS TECH Inc. 5 of 16 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 3. Product Information 3.1 Equipment Description The Equipment Under Test (EUT) is RF transmitter by the XTM Solution. Wireless Calling Bell Transmitter model: BBT-100 (FCC ID: SDIBBT-100). This product is just push the button on the transmitter, then it will show all the pre-set beeping numbers with an alarm noise. It is a simple methβ¦
Text truncated - open the document above for the full version.
BWS TECH Inc. 1 of 1 294-9 Jungdae-Dong, Kwanggu-Si,Kyunggi-Do, 464-800, Korea Report No: BWS-04-RF-0016 FCC ID : SDIBBT-100 Date of Test : July 12, 2004 XTM Solution Wireless Calling Bell Transmitter BBT-100 Appendix 1. Test Setup Photographs Radiated Emission Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 345 MHz - 345 MHz | - |