
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Fluance Ai41 Quick Start Guide Ai41 – Powered Bookshelf Speakers Quick Start Guide v1.0 Fluance Ai41 Quick Start Guide Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. if the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit form the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over. 13. Unplug this apparatus during lightning storms or when unused for long periods of time. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in anyway, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15. The use of apparatus in moderate climates. CAUTION • Minimum 5cm around the apparatus for sufficient ventilation. • The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, curtains, etc. • No naked flame sources, such as lighted candles, should be placed on the apparatus. • Should be drawn to the environmental aspects of the battery disposal. • To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. • Battery shall not be exposed to excessive heat such as sunshine, fire or the like. • The mains plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable. Fluance Ai41 Quick Start Guide Précautions De Sécurité Importantes a Lire En Premier 1. Lisez ces instructions. 2. Conservez ces instructions. 3. Tenez compte de tous les avertissements. 4. Suivez toutes les instructions. 5. N’utilisez pas cet appareil près de l’eau. 6. Nettoyer uniquement avec un chiffon sec. 7. Ne bloquez aucune ouverture de ventilation. Installez conformément aux instructions du fabricant. 8. Ne pas installer à proximité de sources de chaleur telles que des radiateurs, des registres de chaleur, des poêles ou d’autres appareils (y compris des amplificateurs) qui produis- ent de la chaleur. 9. Ne détournez pas le but de sécurité de la prise polarisée ou de mise à la terre. Une fiche polarisée comporte deux pales dont une plus large que l’autre. Une fiche de type à la terre a deux lames et une troisième broche de mise à la terre. La lame large ou la troisième broche sont fournies pour votre sécurité. Si la fiche fournie ne rentre pas dans votre prise, consultez un électricien pour le remplacement de la sortie obsolète. 10. Protégez le cordon d’alimentation avant d’être piétiné ou pincé en particulier sur les bouchons, les prises de courant et le point où ils sortent de l’appareil. 11. N’utilisez que des accessoires / accessoires spécifiés par le fabricant. 12. Utilisez uniquement avec le chariot, le support, le trépied, le support ou la table spécifiés par le fabricant ou vendus avec l’appareil. Lorsqu’un chariot est utilisé, soyez prudent lorsque vous déplacez la combinaison panier / appareil pour éviter les blessures causées par le renversement. 13. Débranchez cet appareil pendant les orages ou lorsqu’il n’est pas utilisé pendant de longues périodes. 14. Référer tous les services à un personnel qualifié. Un entretien est nécessaire lorsque l’appareil a été endommagé de toute façon, comme le cordon d’alimentation ou la fiche est endommagé, le liquide a été renversé ou les objets sont tombés dans l’appareil, l’appareil a été exposé à la pluie ou à l’humidité, s’il ne fonctionne pas normalement ou s’il est tombé. 15. L’utilisation d’appareils dans les climats modérés. ATTENTION • 5cm minimale autour de l’appareil pour une aération suffisante. • il convient que l’aeration ne soit pas gênée par l’obstruction des ouvertures d’aération par des objets tels que journaux, nappes, rideaux, etc... • il convent de ne pas placer sur l’appareil de sources de flammes nues, telles que des bougies allumées. • il convent d’attirer l’attention sur les problèmes d’environnement dus à la mise au déchet des piles. • le mode d’emploi doit stipuler que l’appareil ne doit pas être exposé à des égouttements d’eau ou des éclaboussures et de plus qu’aucun objet rempli de liquide tel que des vases ne doit être placé sur l’appareil. • Un avertissement selon lequel les batteries (bloc de batteries ou batteries installées) ne doivent pas être exposées à une chaleur excessive telle que celle du soleil, d’un feu ou d’origine simi- laire. • lorsque la prise du RESEAU D’ALIMENTATION ou une prise placée sur l’appareil est utilisée comme appareil de déconnecxion, cet appareil doit demeurer aisément accessible. Fluance Ai41 Quick Start Guide Introduction Thank you for your purchase of your Fluance product. We hope you enjoy your experience. If you have any questions please visit us at www.Fluance.com/support. Fluance believes everyone should experience audio in its truest form, recreating the p…
Text truncated - open the document above for the full version.
Circus World Displays Limited for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 <2020-08-10> TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC IDModel name Ai41SMH-AI41 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, ------------------------------------ Name:Raj Jain/President Company: Circus World Displays Limited Address: 4080 Montrose Road Niagara Falls, Ontario, Canada L2H 1J9 Phone:9053530732 Fax:9053530732 E-Mail:[email protected]
Circus World Displays Limited 4080 Montrose Road Niagara Falls, Ontario, Canada L2H 1J9 Tel: 9053530732 Fax: 9053530732 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2020/08/10 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relati ng to applications for equipment authorization FCC ID: [SMH-AI41] including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name:Raj Jain/President Company: Circus World Displays Limited Address: 4080 Montrose Road Niagara Falls, Ontario, Canada L2H 1J9 Phone:9053530732 Fax:9053530732 E-Mail:[email protected]
FCC ID: SMH-AI41 IC: 4593A-AI41 FCC ID: SMH-AI41 IC: 4593A-AI41 FCC ID: SMH-AI41 IC: 4593A-AI41 FCC ID: SMH-AI41 IC: 4593A-AI41
FCC ID: SMH-AI41 IC: 4593A-AI41 FCC ID: SMH-AI41 IC: 4593A-AI41 FCC ID: SMH-AI41 IC: 4593A-AI41 FCC ID: SMH-AI41 IC: 4593A-AI41 Ant FCC ID: SMH-AI41 IC: 4593A-AI41
RF Exposure evaluation Exposure category: General population/uncontrolled environment EUT Type: Production Unit Device Type: Mobile Device Refer Standard: KDB 447498 D01 General RF Exposure Guidance v06 FCC Part 2 §2.1091 FCC ID: SMH-AI41 1. Reference According to §1.1307(b)(1), systems operating under the provisions of this section shallbe operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2. Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.06141.63(100) * 6 3.0 – 301842/f4.89/f(900/f 2 )*6 30 – 30061.40.1631.06 300 – 1500//f/3006 1500 – 100,000//56 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.06141.63(100) *30 3.0 – 30824/f2.19/f(180/f 2 )*30 30 – 30027.50.0730.230 300 – 1500 //f/150030 1500 – 100,000 //1.030 F=frequency in MHz *=Plane-wave equivalent power density 3. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. Result As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used BT antenna is -0.58dBi, the RF power density can be obtained. BLE Freq. (MHz) Output Power (dBm) Target power W/ tolerance (dBm) Max tune up power tolerance (dBm) Output power to antenna (mW) Ant Gain (dBi) Power Density at R=20cm (mW/cm2) Limit (mW/c m2) Result GFSK 24021.039 1 ± 1.0 2 1.585-0.58 0.000281 Pass 24400.869 1 ± 1.0 2 1.585-0.58 0.000281Pass 24800.359 0 ± 1.0 1 1.259-0.58 0.000221Pass Note: The estimation distance is 20cm 5. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device.
Page1of35ReportNo.:UNIA20071302FR-01 FCCRADIOTESTREPORT FCCID:SMH-AI41 IC:4593A-AI41 Product : PoweredBookshelfSpeaker TradeName : FLUANCE ModelName/HVIN(s): Ai41 SerialModel : N/A ReportNo. : UNIA20071302FR-01 Preparedfor CircusWorldDisplaysLimited 4080MontroseRoadNiagaraFalls,Ontario,CanadaL2H1J9 Preparedby ShenzhenUnitedTestingTechnologyCo.,Ltd. 2F,AnnexBldg,JiahuangyuanTechPark,#365Baotian1Rd,Tiegang Community,XixiangStr,Bao'anDistrict,Shenzhen,China Page2of35ReportNo.:UNIA20071302FR-01 TESTRESULTCERTIFICATION Applicant’sname....................: CircusWorldDisplaysLimited Address ...................................... : 4080MontroseRoadNiagaraFalls,Ontario,CanadaL2H1J9 Manufacture'sName..............: SHENZHENAVTECHTECHNOLOGYCo.,LTD Address ...................................... : 501A-601,BuildingNo.6,HongaoIndustrialPark,Tianliao Community,YutangStreet,GuangmingDistrict,Shenzhen, China. Productdescription Productname............................... : PoweredBookshelfSpeaker TradeMark ................................. : FLUANCE Modeland/ortypereference.: Ai41 Standards..................................: FCCRulesandRegulationsPart15SubpartCSection15.247, RSS-247Issue2:February2017,RSS-GenIssue5April2018 ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyShenzhenUnitedTestingTechnology Co.,Ltd.,andthetestresultsshowthattheequipmentundertest(EUT)isincompliance withtheFCCrequirements.Anditisapplicableonlytothetestedsampleidentifiedinthe report. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofUNI,this documentmaybealteredorrevisedbyShenzhenUnitedTestingTechnologyCo.,Ltd., personnelonly,andshallbenotedintherevisionofthedocument. DateofTest ............................................... : Date(s)ofperformanceoftests ............... :Jun.20~Jul.17,2020 DateofIssue..............................................:Jul.20,2020 TestResult..................................................:Pass Testby: Bobliao/Enginner Reviewer: Kahnyang/Supervisor Approved&AuthorizedSigner: Liuze/Manager Page3of35ReportNo.:UNIA20071302FR-01 TableofContentsPage 1.TESTSUMMARY...................................................................................................................5 1.1TESTPROCEDURESANDRESULTS..................................................................................5 1.2TESTFACILITY..........................................................................................................................5 1.3MEASUREMENTUNCERTAINTY..........................................................................................5 2.GENERALINFORMATION ................................................................................................... 6 2.1GENERALDESCRIPTIONOFEUT.......................................................................................6 2.2CarrierFrequencyofChannels...............................................................................................7 2.3OperationofEUTduringtesting..............................................................................................7 2.4DESCRIPTIONOFTESTSETUP...........................................................................................7 2.5MEASUREMENTINSTRUMENTSLIST................................................................................8 3.CONDUCTEDEMISSIONSTEST.......................................................................................9 3.1ConductedPowerLineEmissionLimit ..................................................................................... 9 3.2TestSetup ..................................................................................................................................... 9 3.3TestProcedure ............................................................................................................................. 9 3.4TestResult .................................................................................................................................... 9 4.RADIATEDEMISSIONTEST.............................................................................................12 4.1RadiationLimit...........................................................................................................................12 4.2TestSetup...................................................................................................................................12 4.3TestProcedure...........................................................................................................................13 4.4TestResult..................................................................................................................................13 5.BANDEDGE ......................................................................................................................... 18 5.1Limits...........................................................................................................................................18 5.2TestProcedure...........................................................................................................................18 5.3TestResult..................................................................................................................................18 6.OCCUPIEDBANDWIDTHMEASUREMENT..................................................................19 6.1TestLimit ..................................................................................................................................... 19 6.2TestProcedure ........................................................................................................................... 19 6.3MeasurementEquipmentUsed ............................................................................................... 19 6.4TestResult .................................................................................................................................. 19 7.POWERSPECTRALDENSITYTEST.............................................…
Text truncated - open the document above for the full version.
FCC ID: SMH-AI41 IC: 4593A-AI41 Radiated Emission (Below 1G) Radiated Emission (Above 1G) FCC ID: SMH-AI41 IC: 4593A-AI41 Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.30 mW |

Powered Bookshelf Speaker
Equipment Class
DTS - Digital Transmission System
2.4GHz Wireless Security Camera with Dual Channel Receiver (Camera Unit)
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
2.4GHz Wireless Security Camera with Dual Channel Receiver (Receiver Unit)
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
2.4GHz Wireless Security Camera with Dual Channel Receiver (Camera Unit)
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
2.4GHz Audio Baby Monitor - Parent Unit
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter