Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
GET STARTED FCC ID: SN2-B0113 IC: 11003A-B0113 Model: B0113 FCC ID: SN2-B0113A IC: 11003A-B0113A Model: B0113A Please visit blastmotion.com/regulatory to view all regulatory information. FOLDFOLD EXTERIOR v ......................................................... ......................................................... 01. 02. Download Blast Putt from the App Store and install it on your device. Need help? For more information scan the code or visit: blastmotion.com/golfputt/getstarted Place the sensor in the attachment. ......................................................... ......................................................... 05. 06. Wake the sensor to pair it with your device. Putt You can take practice strokes, make contact with the ball to start recording. ......................................................... ......................................................... 03. 04. Align the top of the Blast logo with the face of the putter head. Start the app and sign up as a new user. Point the grip of the club to the ground for two seconds. Then hold the putter upright, with the club head close to the ground. a. b. Stretch the putt attachment over the putter grip. Press the sensor into the top of the putter attachment. a. b. * Sensors are shipped charged, but recharging the sensor prior to first use is advised. Blast LogoPutter Head FOLDFOLD INTERIOR
FCC ID SN2-B0113 IC: 11003A-B0113 The EUT does not have a separate label due to its size (please see attestation letter included with this filing). Label information can be found in the User’s Manual which is in an electronic format on the Blast Motion Web Site accessible through the software application
FCC ID SN2-B0113 IC: 11003A-B0113
FCC ID SN2-B0113 IC: 11003A-B0113 The EUT does not have a separate label due to its size (please see attestation letter included with this filing). Label information can be found in the User’s Manual which is in an electronic format on the Blast Motion Web Site accessible through the software application
FCC ID SN2-B0113 IC: 11003A-B0113
TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364 February 06, 2014 TUV SUD BABT Octagon House, Concorde Way Segensworth Rd N, Fareham PO15 5RL Attention: Director of Certification RE: Analysis of RF Exposure for Portable and Mobile use per KDB 447498 D01 Mobile Portable RF Exposure v05r01 and RSS-102 Issue 4 March 2010 IC: 11003A-B0113 FCC ID: SN2-B0113 Portable exposure SAR Exemption Calculation using a 6mm separation distance: As per Clause 4.3.1.1 of KDB 447498 D01 v05r01: � max.power of channel,including tune −up tolerance,mW min.test separation distance,mm � x �� 푓 ( 퐺퐻푧 ) � ≤ 3.0 � 0.0114 mW 6 mm � x � � 2. 402 ( 퐺퐻푧 ) � ≤ 3.0 0.003 ≤ 3.0 (complies) Sincerely, Ferdie S. Custodio Name Authorized Signatory Title: Senior EMC/Wireless Test Engineer
Report No. SC1312333 January 2014 America Report On Radio Testing of the Blast Motion, Inc. Blast B0113 Wireless Motion Sensor FCC Part 15 Subpart C §15.249 IC RSS-210 Issue 8 December 2010 TÜV SÜD America Inc., 10040 Mesa Rim Road, San Diego, CA 92121 Tel: (858) 678-1400. Website: www.TUVamerica.com Page 2 of 44 TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364 REPORT ON TEST REPORT NUMBER PREPARED FOR Radio Testing of the Blast Motion, Inc. Wireless Motion Sensor SC1312333 Blast Motion, Inc. 2281 Las Palmas Drive, Suite 101 Carlsbad, CA 92011 CONTACT PERSON Mark Winbigler Sr. Manufacturing Engineer (760) 803-2724 [email protected] PREPARED BY Ferdinand S. Custodio Name Authorized Signatory Title: EMC/Wireless Test Engineer APPROVED BY Chip R. Fleury Name Authorized Signatory DATED December 31, 2013 TÜV SÜD America Inc., 10040 Mesa Rim Road, San Diego, CA 92121 Tel: (858) 678-1400. Website: www.TUVamerica.com Page 3 of 44 TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364 Revision History SC1312333 Blast Motion, Inc. Blast Wireless Motion Sensor DATE OLD REVISION NEW REVISION REASON PAGES AFFECTED APPROVED BY 12/31/13 Initial Release Chip R. Fleury FCC ID SN2-B0113 IC: 11003A-B0113 Report No. SC1312333 Page 4 of 44 TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364 CONTENTS Section Page No 1 REPORT SUMMARY ............................................................................................................................... 5 1.1 Introduction ................................................................................................................................................ 6 1.2 Brief Summary Of Results ........................................................................................................................... 7 1.3 Product Information ................................................................................................................................... 8 1.4 EUT Test Configuration ............................................................................................................................. 10 1.5 Deviations From The Standard ................................................................................................................. 12 1.6 Modification Record ................................................................................................................................. 12 1.7 Test Methodology ..................................................................................................................................... 12 1.8 Test Facility Location ................................................................................................................................. 12 1.9 Test Facility Registration ........................................................................................................................... 13 2 TEST DETAILS ...................................................................................................................................... 14 2.1 Conducted Emissions ................................................................................................................................ 15 2.2 20 dB Bandwidth ....................................................................................................................................... 16 2.3 99% Emission Bandwidth .......................................................................................................................... 20 2.4 Field Strength Limits For Fundamental And Harmonics ........................................................................... 24 2.5 Spurious Radiated Emissions .................................................................................................................... 30 2.6 Receiver Spurious Emissions ..................................................................................................................... 33 3 TEST EQUIPMENT USED ...................................................................................................................... 37 3.1 Test Equipment Used ................................................................................................................................ 38 3.2 Measurement Uncertainty ....................................................................................................................... 39 4 DIAGRAM OF TEST SETUP ................................................................................................................... 40 4.1 Radiated Emission Test Setup (Below 1GHz) ............................................................................................ 41 4.2 Radiated Emission Test Setup (Above 1GHz) ............................................................................................ 42 5 ACCREDITATION, DISCLAIMERS AND COPYRIGHT ............................................................................... 43 5.1 Accreditation, Disclaimers and Copyright ................................................................................................. 44 FCC ID SN2-B0113 IC: 11003A-B0113 Report No. SC1312333 Page 5 of 44 TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364 SECTION 1 REPORT SUMMARY Radio Testing of the Blast Motion, Inc. Wireless Motion Sensor FCC ID SN2-B0113 IC: 11003A-B0113 Report No. SC1312333 Page 6 of 44 TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364 1.1 INTRODUCTION The information contained in this report is intended to show verification of the Blast Motion, Inc. Wireless Motion Sensor to the requirements of FCC Part 15 Subpart C §15.249 and IC RSS-210 Issue 8 December 2010. Objective To perform Radio Testing to determine the Equipment Under Test's (EUT’s) comp…
Text truncated - open the document above for the full version.
FCC ID SN2-B0113 IC: 11003A-B0113 Radiated Emissions Test Setup (below 1GHz) Radiated Emissions Test Setup (above 1GHz) Radiated Emissions Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 11.40 µW |

Bluetooth motion capture sensor
Equipment Class
DTS - Digital Transmission System