Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SZ DJI TECHNOLOGY CO., LTD Date: 6/18/2024 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(5) Attestation FCC ID: SS3-TKPL22310 Grantee FRN: 0022596753 1. SZ DJI TECHNOLOGY CO., LTD certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2. SZ DJI TECHNOLOGY CO., LTD certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Sincerely yours, Name: Gary Zeng Job Title: certification supervisor Company Name: SZ DJI TECHNOLOGY CO., LTD
SZ DJI TECHNOLOGY CO., LTD Date: 6/18/2024 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(7) Agent Designation Attestation FCC ID: SS3-TKPL22310 Grantee FRN: 0022596753 SZ DJI TECHNOLOGY CO., LTD as required by section 2.911(d)(7), designates the following agent, located in the United States, for purposes of acting as the applicant’s agent for service of process. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility under CFR 47 §2.929(c) to inform the FCC whenever the agent information changes. U.S. Agent Information: Contact Person: DJI Research LLC FCC FRN: 0033569757 Company Name: JIE SHEN Company Address: 17301 Edwards Road, Cerritos, CA 90703 Email: [email protected] Sincerely yours, Name: Gary Zeng Job Title: certification supervisor Company Name: SZ DJI TECHNOLOGY CO., LTD
SZ DJI TECHNOLOGY CO., LTD Date: 4/11/2024 UL Verification Services Inc. 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. In authorizing UL Verification Services Inc. as our representative, we still recognize that we are responsible to: a) fulfill the requirements for the scope of certification requested, including implementing any appropriate changes requested by UL Verification Services Telecommunications Certification Body (TCB) and / or the FCC; b) supply any and all information needed for the evaluation of the products for which certification is sought; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) not use our product certification in such a manner as to bring the TCB or FCC into disrepute and to not make any statement regarding product certification which the TCB or FCC may consider misleading or unauthorized; e) discontinue use of all advertising matter that contains any reference thereto and complies with any and all actions required by the FCC upon suspension or cancellation of certification; f) use certification only to indicate that products are certified in conformity with specified standards; g) endeavor to ensure that no certificate or report or any part thereof is used in a misleading manner, and any copies of the grants/certificates shall be reproduced in their entirety; h) comply with the requirements of the TCB and FCC, including the use of marks and label information prescribed for the scope of certification, when making reference to product certification in communication media such as documents, brochure or advertisements; i) comply with the requirements for certification, supply any information needed for evaluation of products to be certified and, where applicable, make provision for the participation of observers; j) ensure that products marketed under the scope of the requested certification continue to comply with the certification requirements; k) provide a sample of a production unit for testing within 30 days of the request should this product be selected as part of either the TCB’s or the FCC’s market surveillance requirements; l) keep a record of all complaints relating to product’s compliance with requirements of relevant standard; make records available to UL or FCC when requested; take appropriate action with respect to such complaints and any deficiencies found in the product that affect compliance with requirements for certification; document the actions taken with respect to complaints and/or deficiencies; m) inform the TCB immediately of any changes that may affect its ability to comply with the certification requirements. This authorization is valid until further written notice from the applicant. Sincerely Yours, Company Name: SZ DJI TECHNOLOGY CO., LTD Contact Name: Gary Zeng Title of Person: certification supervisor Address: Lobby of T2, DJI Sky City, No 53 Xianyuan Road, Xili Community, Xili Street, Nanshan District, Shenzhen, China
SZ DJI TECHNOLOGY CO., LTD DATE : 2024-6-18 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Request for Short-Term Confidentiality Company name: SZ DJI TECHNOLOGY CO., LTD FCC ID: SS3-TKPL22310 FCC Part 15 Certification Pursuant to Sections 0.457 and 0.459 of the commission rules, and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705), we hereby request short-term confidentiality for the following items prior to marketing the device.: (1) Test Setup Photos (2) External Photos (3) Internal Photos (4) User Manual The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Sincerely, Signature Company Name: SZ DJI TECHNOLOGY CO., LTD Contact Name: Gary Zeng Title of Person: certification supervisor Address: Lobby of T2, DJI Sky City, No 53 Xianyuan Road, Xili Community, Xili Street, Nanshan District, Shenzhen, China
SZ DJI TECHNOLOGY CO., LTD Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: SS3-TKPL22310 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation BOM list Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards Company Name: SZ DJI TECHNOLOGY CO., LTD Contact Name: Gary Zeng Title of Person: certification supervisor Address: Lobby of T2, DJI Sky City, No 53 Xianyuan Road, Xili Community, Xili Street, Nanshan District, Shenzhen, China Date:6/ 18/2024
Label locates on the back of the device
. Measurement Report for Device, , , UID 0 -, Channel 0 (2450.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, N/A x N/A x N/A Dipole Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL , , 0-- 2450.000, 0 7.98 1.88 40.2 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V8.0 (20deg probe tilt) - xxxx HBBL-600-10000 Charge:xxxx, 2024-Jun-22 EX3DV4 - SN7733, 2024-02-21 DAE4 Sn1739, 2024-01-23 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 40.0 x 80.0 30.0 x 30.0 x 30.0 Grid Steps [mm] 10.0 x 10.0 5.0 x 5.0 x 1.5 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Yes Grading Ratio N/A 1.5 MAIA N/A N/A Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2024-06-22, 09:20 2024-06-22, 09:28 psSAR1g [W/kg] 13.7 13.6 psSAR10g [W/kg] 6.29 6.21 Power Drift [dB] -0.04 -0.01 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 80.8 Dist 3dB Peak [mm] 9.0 Warning(s) / Error(s) Details Area Scan Zoom Scan Warning(s) Error(s) . Measurement Report for Device, , , UID 0 -, Channel 0 (2450.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, N/A x N/A x N/A Dipole Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL , , 0-- 2450.000, 0 7.98 1.87 40.1 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V8.0 (20deg probe tilt) - xxxx HBBL-600-10000 Charge:xxxx, 2024-Jul-22 EX3DV4 - SN7733, 2024-02-21 DAE4 Sn1739, 2024-01-23 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 40.0 x 80.0 30.0 x 30.0 x 30.0 Grid Steps [mm] 10.0 x 10.0 5.0 x 5.0 x 1.5 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Yes Grading Ratio N/A 1.5 MAIA N/A N/A Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2024-07-22, 08:35 2024-07-22, 08:42 psSAR1g [W/kg] 13.7 13.1 psSAR10g [W/kg] 6.14 6.11 Power Drift [dB] -0.01 -0.03 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 80.8 Dist 3dB Peak [mm] 9.0 Warning(s) / Error(s) Details Area Scan Zoom Scan Warning(s) Error(s) . Measurement Report for Device, , , UID 0 -, Channel 0 (5250.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, N/A x N/A x N/A Dipole Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL , , 0-- 5250.000, 0 5.64 4.63 35.4 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V8.0 (20deg probe tilt) - xxxx HBBL-600-10000 Charge:xxxx, 2024-Jun-24 EX3DV4 - SN7733, 2024-02-21 DAE4 Sn1739, 2024-01-23 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 40.0 x 80.0 22.0 x 22.0 x 22.0 Grid Steps [mm] 10.0 x 10.0 4.0 x 4.0 x 1.4 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Yes Grading Ratio N/A 1.4 MAIA N/A N/A Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2024-06-24, 08:35 2024-06-24, 08:43 psSAR1g [W/kg] 7.61 7.89 psSAR10g [W/kg] 2.35 2.37 Power Drift [dB] 0.01 0.00 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 65.9 Dist 3dB Peak [mm] 7.4 Warning(s) / Error(s) Details Area Scan Zoom Scan Warning(s) Error(s) . Measurement Report for Device, , , UID 0 -, Channel 0 (5250.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, N/A x N/A x N/A Dipole Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL , , 0-- 5250.000, 0 5.64 4.64 35.3 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V8.0 (20deg probe tilt) - xxxx HBBL-600-10000 Charge:xxxx, 2024-Jul-25 EX3DV4 - SN7733, 2024-02-21 DAE4 Sn1739, 2024-01-23 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 40.0 x 80.0 22.0 x 22.0 x 22.0 Grid Steps [mm] 10.0 x 10.0 4.0 x 4.0 x 1.4 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Yes Grading Ratio N/A 1.4 MAIA N/A N/A Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2024-07-25, 10:01 2024-07-25, 10:09 psSAR1g [W/kg] 7.63 8.11 psSAR10g [W/kg] 2.43 2.39 Power Drift [dB] 0.01 0.05 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 65.9 Dist 3dB Peak [mm] 7.4 Warning(s) / Error(s) Details Area Scan Zoom Scan Warning(s) Error(s) . Measurement Report for Device, , , UID 0 -, Channel 0 (5750.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, N/A x N/A x N/A Dipole Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL , , 0-- 5750.000, 0 5.05 5.04 35.4 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V8.0 (20deg probe tilt) - xxxx HBBL-600-10000 Charge:xxxx, 2024-Jun-22 EX3DV4 - SN7733, 2024-02-21 DAE4 Sn1739, 2024-01-23 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 40.0 x 80.0 22.0 x 22.0 x 22.0 Grid Steps [mm] 10.0 x 10.0 4.0 x 4.0 x 1.4 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Yes Grading Ratio N/A 1.4 MAIA N/A N/A Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2024-06-22, 08:26 2024-06-22, 08:33 psSAR1g [W/kg] 7.25 7.…
Text truncated - open the document above for the full version.
2.4G WIFI 2412MHz 5mm-WiFi L . Measurement Report for Device, EDGE RIGHT, WLAN 2.4GHz, UID 10012 CAB, Channel 1 (2412.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, 300.0 x 280.0 x 100.0 Other Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL EDGE RIGHT, 5.00 WLAN 2.4GHz WLAN, 10012-CAB 2412.000, 1 7.98 1.85 40.1 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V8.0 (20deg probe tilt) - xxxx HBBL-600-10000 Charge:xxxx, 2024-Jun-22 EX3DV4 - SN7733, 2024-02-21 DAE4 Sn1739, 2024-01-23 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 140.0 x 340.0 30.0 x 30.0 x 30.0 Grid Steps [mm] 10.0 x 10.0 5.0 x 5.0 x 1.5 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Yes Grading Ratio N/A 1.5 MAIA N/A N/A Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2024-06-22, 10:29 2024-06-22, 10:36 psSAR1g [W/kg] 0.845 0.835 psSAR10g [W/kg] 0.387 0.375 Power Drift [dB] 0.10 -0.06 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 81.3 Dist 3dB Peak [mm] 10.0 Warning(s) / Error(s) Details Area Scan Zoom Scan Warning(s) Error(s) 5G WIFI 5200MHz 5mm- WiFi R . Measurement Report for Device, EDGE LEFT, U-NII-1, U-NII-2A, UID 10062 CAE, Channel 40 (5200.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, 300.0 x 280.0 x 100.0 Other Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL EDGE LEFT, 5.00 U-NII-1, U-NII-2A WLAN, 10062-CAE 5200.000, 40 5.64 4.94 35.6 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V8.0 (20deg probe tilt) - xxxx HBBL-600-10000 Charge:xxxx, 2024-Jun-24 EX3DV4 - SN7733, 2024-02-21 DAE4 Sn1739, 2024-01-23 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 140.0 x 340.0 22.0 x 22.0 x 22.0 Grid Steps [mm] 10.0 x 10.0 4.0 x 4.0 x 1.4 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Yes Grading Ratio N/A 1.4 MAIA Y N/A Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2024-06-24, 09:16 2024-06-24, 09:27 psSAR1g [W/kg] 0.525 0.559 psSAR10g [W/kg] 0.203 0.204 Power Drift [dB] 0.09 -0.02 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 64.2 Dist 3dB Peak [mm] 8.3 Warning(s) / Error(s) Details Area Scan Zoom Scan Warning(s) Error(s) 5G WIFI 5785MHz 5mm- WiFi R . Measurement Report for Device, EDGE LEFT, U-NII-2C, U-NII-3, UID 10062 CAE, Channel 157 (5785.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, 300.0 x 280.0 x 100.0 Other Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL EDGE LEFT, 5.00 WLAN 5GHz WLAN, 10062-CAE 5785.0, 157 5.05 5.08 35.4 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V8.0 (20deg probe tilt) - xxxx HBBL-600-10000 Charge:xxxx, 2024-Jun-22 EX3DV4 - SN7733, 2024-02-21 DAE4 Sn1739, 2024-01-23 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 140.0 x 340.0 22.0 x 22.0 x 22.0 Grid Steps [mm] 10.0 x 10.0 4.0 x 4.0 x 1.4 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Yes Grading Ratio N/A 1.4 MAIA N/A Y Surface Detection VMS + 6p VMS + 6p Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2024-06-22, 20:21 2024-06-22, 20:34 psSAR1g [W/kg] 0.667 0.687 psSAR10g [W/kg] 0.247 0.240 Power Drift [dB] 0.00 -0.03 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 59.1 Dist 3dB Peak [mm] 7.9 Warning(s) / Error(s) Details Area Scan Zoom Scan Warning(s) Error(s) 2.4G SDR 2437.5MHz 5mm-ANT 0 . Measurement Report for Device, BACK, Custom Band, UID 10062 CAE, Channel 2437500 (2437.500MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, 300.0 x 280.0 x 100.0 Other Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL BACK, 5.00 Custom Band CW, 10062-CAE 2437.500, 2437500 7.98 1.88 40.2 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration Date ELI V8.0 (20deg probe tilt) - xxxx HBBL-600-10000 Charge:xxxx, 2024-Jul-22 EX3DV4 - SN7733, 2024-02-21 DAE4 Sn1739, 2024-01-23 Scan Setup Area Scan Zoom Scan Grid Extents [mm] 320.0 x 340.0 30.0 x 30.0 x 30.0 Grid Steps [mm] 10.0 x 10.0 5.0 x 5.0 x 1.5 Sensor Surface [mm] 3.0 1.4 Graded Grid N/A Yes Grading Ratio N/A 1.5 MAIA N/A N/A Surface Detection All points All points Scan Method Measured Measured Measurement Results Area Scan Zoom Scan Date 2024-07-22, 15:06 2024-07-22, 15:20 psSAR1g [W/kg] 2.45 2.71 psSAR10g [W/kg] 1.21 1.31 Power Drift [dB] 0.07 0.07 Power Scaling Disabled Disabled Scaling Factor [dB] TSL Correction No correction No correction M2/M1 [%] 82.0 Dist 3dB Peak [mm] 11.2 Warning(s) / Error(s) Details Area Scan Zoom Scan Warning(s) Error(s) 5.1G SDR 5200MHz 5mm-ANT 0 . Measurement Report for Device, BACK, WLAN 5GHz, UID 10534 AAD, Channel 40 (5200.000MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, 300.0 x 280.0 x 100.0 Other Exposure Conditions Phantom Section, TSL Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Flat, HSL BACK, 5.00 WLAN 5GHz WLAN, 10534-AAD 5200.000, 40 5.64 4.61 35.4 Hardware Setup Phantom TSL, Measured Date Probe, Calibration Date DAE, Calibration D…
Text truncated - open the document above for the full version.
R(Ω)X(jΩ)R(Ω)X(jΩ)R(Ω)X(jΩ) 56.400.96059.220.855 2.82-0.11 Annual Verification Result Measure Date -24.288-21.44-11.7% 16-Dec-22 Return loss(dB) Dipole2450 Head TSL Target ValueMeasure ValueDifference Impedance Annual Verification Result Dipole2450 Head TSL Target Value Measure Value Difference R (Ω) X (jΩ) R (Ω) X (jΩ) R (Ω) X (jΩ) Impedance 56.40 0.960 58.31 -0.127 1.91 -1.09 Return loss(dB) -24.288 -22.3 -8.2% Measure Date 16-Dec-23 Annual Verification Result Dipole5250 Head TSL Target Value Measure Value Difference R(Ω) X(jΩ) R (Ω) X (jΩ) R (Ω) X (jΩ) Impedance 48.99 -5.890 45.94 -5.120 -3.05 0.77 Return loss(dB) -24.399 -23.35 -4.3% Measure Date 14-Dec-22 Annual Verification Result Dipole5600 Head TSL Target Value Measure Value Difference R(Ω) X(jΩ) R (Ω) X (jΩ) R (Ω) X (jΩ) Impedance 50.56 -1.177 49.59 1.540 -0.97 2.72 Return loss(dB) -37.744 -35 -7.3% Measure Date 14-Dec-22 Annual Verification Result Dipole5750 Head TSL Target Value Measure Value Difference R(Ω) X(jΩ) R (Ω) X (jΩ) R (Ω) X (jΩ) Impedance 54.72 0.028 55.70 -1.100 0.98 -1.13 Return loss(dB) -26.929 -25.2 -6.4% Measure Date 14-Dec-22 Annual Verification Result Dipole5250 Head TSL Target Value Measure Value Difference R(Ω) X(jΩ) R(Ω) X(jΩ) R(Ω) X(jΩ) Impedance 48.99 -5.890 49.57 -4.560 0.58 1.33 Return loss(dB) -24.399 -26.75 9.6% Measure Date 14-Dec-23 Annual Verification Result Dipole5600 Head TSL Target Value Measure Value Difference R(Ω) X(jΩ) R(Ω) X(jΩ) R(Ω) X(jΩ) Impedance 50.56 -1.177 48.98 0.191 -1.58 1.37 Return loss(dB) -37.744 -39.56 4.8% Measure Date 14-Dec-23 Annual Verification Result Dipole5750 Head TSL Target Value Measure Value Difference R(Ω) X(jΩ) R(Ω) X(jΩ) R(Ω) X(jΩ) Impedance 54.72 0.028 55.22 -1.440 0.50 -1.47 Return loss(dB) -26.929 -25.78 -4.3% Measure Date 14-Dec-23
UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0036 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. SAR EVALUATION REPORT FCC 47 CFR § 2.1093 IEEE Std. 1528-2013 For DJI RC Plus 2 MODEL NUMBER: TKPL2 REPORT NUMBER: 4790917103-3-SAR-1 ISSUE DATE: Aug. 6, 2024 FCC ID: SS3-TKPL22310 Prepared for SZ DJI TECHNOLOGY CO., LTD. Lobby of T2, DJI Sky City, No 53 Xianyuan Road, Xili Community, Xili Street, Nanshan District, Shenzhen, China Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Building 10, Innovation Technology Park, No. 1, Li Bin Road, Song Shan Lake Hi-Tech Development Zone Dongguan, People’s Republic of China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4790917103-3-SAR-1 Page 2 of 40 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0036 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 Aug. 6, 2024 Initial Issue \ Note: 1) This test report is only published to and used by the applicant, and it is not for evidence purpose in China. 2) The measurement result for the sample received is <Pass> according to < IEEE Std. 1528>when <Simple Acceptance> decision rule is applied. REPORT NO.: 4790917103-3-SAR-1 Page 3 of 40 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0036 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Table of Contents 1. Attestation of Test Results .......................................................................................................... 5 2. Test Specification, Methods and Procedures ............................................................................ 6 3. Facilities and Accreditation ......................................................................................................... 7 4. SAR Measurement System & Test Equipment ........................................................................... 8 4.1. SAR Measurement System .............................................................................................................. 8 4.2. SAR Scan Procedures ..................................................................................................................... 9 4.3. Test Equipment .............................................................................................................................. 11 5. Measurement Uncertainty ......................................................................................................... 12 6. Device Under Test (DUT) Information ....................................................................................... 13 6.1. DUT Description............................................................................................................................. 13 6.2. Wireless Technology ...................................................................................................................... 13 7. Conducted Output Power Measurement and tune-up tolerance ............................................ 14 7.1. Test Results of WiFi 2.4GHz .......................................................................................................... 14 7.2. Test Results of WiFi 5GHz ............................................................................................................. 15 7.3. Test Results of SRD 2.4GHz.......................................................................................................... 16 7.4. Test Results of SRD 5GHz ............................................................................................................ 17 7.5. Duty Cycle ..................................................................................................................................... 20 8. Test Configuration ..................................................................................................................... 24 8.1. Wi-Fi Test Configuration ................................................................................................................ 24 8.1.1. Initial Test Position Procedure .................................................................................................... 24 8.1.2. Initial Test Configuration Procedure ............................................................................................ 24 8.1.3. Sub Test Configuration Procedure.............................................................................................. 24 8.1.4. 2.4GHz Wi-Fi SAR Test Procedures ........................................................................................... 24 8.1.5. 5GHz Wi-Fi SAR Test Procedures .............................................................................................. 26 8.1.6. OFDM Transmission Mode and SAR Test Channel Selection .................................................... 26 9. Antenna location diagram ......................................................................................................... 27 10. RF Exposure Conditions ........................................................................................................... 28 11. Dielectric Property Measurements & System Check ............................................................... 29 11.1. Dielectric Property Measurements ................................................................................................. 29 11.2. System Check ................................................................................................................................ 31 12. Measured and Reported (Scaled) SAR Results ................…
Text truncated - open the document above for the full version.
1 DJI Antenna Datasheet ___RC701 antenna____ __ 2024-04-15 Model number :RC701 antenna 4/5 Revision history Version Change notes Modificator Date V1.0 First draft. Stephen.Wan 2024.04.15 1 DJI Antenna Datasheet 1、 Basic Specifications No. Specification Descriptions Notes 1 Antenna Name RC701 Ant 2 Brand DJI 3 Operation Frequency 2.4~2.483GHz; 5.15~5.25GHz 5.725~5.85GHz 4 Connector Type Ipex-1 5 Impedance 50ohm 6 Gain 2.5 [email protected]~2.483GHz sdr [email protected]~5.25GHz sdr 3.5 [email protected]~5.875GHz sdr 7 Efficiency ≥50% SDR 8 VSWR ≤2 9 Polarization type Linear 10 3dB Beamwidth Omnidirectional horizon 11 Weight 12 Antenna type Dipole 2、 Antenna Return Loss/VSWR 2.1 SDR antenna return loss Freq/GHz 2.4 2.48 5.2 5.725 5.85 S11/dB -8.5-10.3-8.3-15.3-16 3、 Antenna Gain 校准日期:2024/04/11 测试方法:近场转台测试 测试暗室型号:Satimo SG24 天线摆放位置参考坐标系: 3.1 sdr Frequency E Total. dB(dB) Efficiency( ) 2400MHz 2.5 5.74E- 01 2440MHz 2.4 5.60E- 01 2480MHz 2.4 5. 59E- 01 5130MHz 1.5 3.00E- 01 5205MHz 1.5 3.23E- 01 5250MHz 1.4 3.10E- 01 5730MHz 3.4 4.41E-01 5800MHz 3.5 4.52E- 01 5850MHz 3.3 4.71E- 01 4、 Radiation Pattern 4.1 sdr antenna 2.4G radiation pattern 5、 Structure drawing 5.1 SDR antenna Name of the antenna manufacturer:INPAQ Technology Suzhou CO.Ltd Address of the antenna manufacturer:No.5 Chunqiu Road, Xiangcheng Dsitrict,Suzhou, Jiangsu Province Website of the antenna manufacturer:www.inpaq.com
1 DJI Antenna Datasheet ___RC701 antenna____ __ 2024-04-15 Model number :RC701 antenna 0/1 Revision history Version Change notes Modificator Date V1.0 First draft. Stephen.Wan 2024.04.15 1 DJI Antenna Datasheet 1、 Basic Specifications No. Specification Descriptions Notes 1 Antenna Name RC701 Ant 2 Brand DJI 3 Operation Frequency 2.4~2.483GHz; 5.15~5.25GHz 5.725~5.85GHz 4 Connector Type Ipex-1 5 Impedance 50ohm 6 Gain [email protected]~2.483GHz sdr [email protected]~5.25GHz sdr [email protected]~5.875GHz sdr 7 Efficiency ≥50% SDR 8 VSWR ≤2 9 Polarization type Linear 10 3dB Beamwidth Omnidirectional horizon 11 Weight 12 Antenna type Dipole 2、 Antenna Return Loss/VSWR 2.1 SDR antenna return loss 3、 Antenna Gain 校准日期:2023/09/1…
Text truncated - open the document above for the full version.
Building 10, Innovation Technology Park, Song Shan · Dongguan · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 18 | 15E | 5.72 GHz - 5.85 GHz | 104.00 mW |
DJI AGRAS T55
Equipment Class
NII - Unlicensed National Information Infrastructure TXDJI AGRAS T100S, DJI AGRAS T70S
Equipment Class
NII - Unlicensed National Information Infrastructure TXDJI RC Mini
Equipment Class
DTS - Digital Transmission SystemFixed Millimeter Wave Radar
Equipment Class
FDS - Part 15 Field Disturbance SensorRotational Active Phased Array Radar
Equipment Class
FDS - Part 15 Field Disturbance Sensor