Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FIXED RFID READER FR900 QUICK GUIDE This user manual is protected by copyright. Copyright © 2020 Bluebird Inc. All rights reserved. Bluebird Inc. is the designer and manufacturer of Bluebird handheld mobiles. This manual and the programs in this device are protected under international copyright laws, and may not be copied, distributed, translated, or r emoved by any means. Registered Trademark BLUEBIRD is an emerging global brand, striving to lead the market in performance and mobility. Their products represent reliability, innovation, and innovative technology. Bluebird is a registered trademark from the global brand of Bluebird Inc. and is copyright protected. • Bluebird and stylized Bluebird Logo are registered trademarks and symbols of Bluebird Inc. • Adobe ® is a registered trademark of Adobe Systems Inc. • All other trademarks and copyrights are the property of their respective owners. 1 Safety Information 1 Safety Information 1.1 Symbols This manual uses the following symbols to indicate hazards and additional information. SymbolNameDescription WarningIndicates situations that could cause injury to yourself or others. CautionIndicates situations that could cause damage to your device or other equipment. NoteIndicates additional information that can help you get the most out of the device. Please read this safety precaution information carefully. Failure to follow the information provided may result in fire, electric shock, or other property damage or bodily injuries. 1.2 Device • Do not press the Power button on the device if the device is wet or do not touch adapter or power cord with wet hands. There is risk of electric shock. • Do not use your device in an explosive danger zone. • If your device becomes wet, do not put your device in heaters, microwaves, etc. to dry it. There is a risk of explosion or malfunction. • Although this device is very sturdy, do not drop, hit, bend, or sit on it on purpose. It can be broken. • Do not modify, take apart, or repair the device. Contact to your customer service center. Failure to do so will void your warranty. • Do not attempt to modify your hardware or software. It may cause device malfunction and void your warranty. • Backup the data and information from your device. Your data may be erased during repairs or upgrades. • Do not paint your device. It can damage your device’s exterior. • Avoid using or storing this device at extreme temperatures. This device is designed to work at temperatures between -10°C and 55°C (14°F and 131°F), and humidity level between 5% and 95%. Safety Information 2 1.3 Environment •Do not use the device while driving or operating heavy machinery. Doing so may result in death or serious injury. • Do not use the device in locations with combustible goods. Doing so may result in an explosion. •Do not use the device in dusty or hot locations. Doing so may damage the device. • Do not expose your device to direct sunlight such as on the dashboard of a car for extended periods of time. • Do not use the device in humid locations. Doing so may damage the device and void the warranty. • Do not keep the device close to air conditioner vents. Corrosion within the device may occur due to condensation from changes in temperature. • Do not allow children to play with the device. 1.4 Frequency Interference • The device emits an electromagnetic fields. It may interfere with your medical devices. • Do not place credit cards, phone cards, bankbook, and tickets next to the device. The magnetic field of the device can damage their magnetic strips. 3 2.1 Package Contents The package includes: Power adaptor FR90 0 device Overview 2 Overview Power Cable Overview 4 2.2 Your Device 2.2.1 Front 2.2.2 Back LED Overview 5 2.2.3 Bottom of Front GPIO 24 VDC Antenna Ports Ethernet USB Host Reset Function Serial USB Device (management) (management) 3 Installing and Connecting This section provides details about FR900 I/O ports and status LEDs. It also explains how to install the Reader and connect it to your network 3.1 FR900 LED Status Boot C omplete Status When t he FR900 has finished booting, the ACTV-STAT-ERR LED will turn on three times in green. LLRP Server Status : Status ACTV STAT ERR Normal (not RFID Tagging) - GREEN - Initialize fail - RED RED Blink Connection or disconnection with client - GREEN Blink (2 times) - RFID Tagging GREEN Blink GREEN - Table 3.1 LLRP Server Status LED Image Upgrad e Status : Status ACTV STAT ERR Image upgrade GREEN GREEN - Factory Reset GREEN RED - Table 3.2 Image upgade Status LED 3.2 Installing and Connecting the Reader The p rimary installation and connection steps for FR900 are: 1.Position the Reader appropriately for your environment. 2.Connect the antenna (s) to the appropriate ports on the Reader. 3.Connect power to the Reader. 4.Connect the Reader to the network. 5.Configure region setting on the Reader. 6.Test the Reader installation by reading tags. 3.3 Detailed Installation Procedures Thi s section provides the details for each installation and connection step. 3.3.1 Step 1: Position the FR900 Reader and install the Reader. Cho ose a suitable location for your Reader. The device should be placed away from direct sunlight, high humidity, extreme temperatures and sources of electromagnetic interference. To power the reader using an external universal power supply, make sure the outlet is nearby. 6 Installing and Connecting 3.3.2 S tep 2: Connect the Antenna(s) to the FR900 Reader FR900 Read er has eight antenna ports. Each port is independent, bidirectional, and half duplex TX/ RX (monostatic). To connect the antenna(s) to the Reader: 1 . Position each Reader antenna, keeping the following points in mind: • Position the antenna(s) to achieve the most effective and efficient tag reads. • Position the antenna(s) to maximize operator safety. 2. Mount the antenna(s) according to the instructions provided by the antenna manufacturer. 3. Attach the antenna cable(s) to the antenna port(s) on the Reader. …
Text truncated - open the document above for the full version.
BLUEBIRD INC. (Dogok-dong, SEI Tower 13,14)39, Eonjuro30-gil, Gangnam-gu, Seoul, South Korea February 20, 2020 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 In re : BLUEBIRD INC. FCC Application for FCC ID : SS4FR900 To whom it may concern: We, the undersigned, hereby attest to the fact that we will apply the Supplier’s Declaration of Conformity procedure to the class A computer peripheral portion of this composite filing. Regards, Sincerely, Yong Sik, Jang /QA Senior Manager BLUEBIRD INC.
BLUEBIRD INC. (Dogok-dong, SEI Tower 13,14)39, Eonjuro30-gil, Gangnam-gu, Seoul, South Korea February 20, 2020 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 LETTER OF AUTHORIZATION To whom it may concern: We, the undersigned, hereby authorize LTA Co., Ltd., to act on our behalf in all manners relating to application for equipment authorization for FCC ID: SS4FR900 including signing of all documents relating to these matters. Any and all acts carried out by LTA Co., Ltd., on our behalf shall have the same affect as acts of our own. This authorization is valid until further written notice from BLUEBIRD INC. LTA Co.,LTD. (Contact Person) Contact name: Ja-Beom Koo Position: Manager Phone:(82)31-323-6008 E-mail: [email protected] Sincerely, Yong Sik, Jang / QA Senior Manager BLUEBIRD INC.
BLUEBIRD INC. (Dogok-dong, SEI Tower 13,14)39, Eonjuro30-gil, Gangnam-gu, Seoul, South Korea February 20, 2020 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 In re : BLUEBIRD INC. FCC ID : SS4FR900 Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), BLUEBIRD INC. hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give BLUEBIRD INC. temporary confidentiality of commercially sensitive information prior to product release. The requested Confidential and Temporary Confidential exhibits are listed as follows: Exhibit Type File Name CONFIDENTIAL Schematics CONF APPENDIX SS4FR900 SCH DIA.pdf Parts list CONF APPENDIX SS4FR900 PL.pdf Block diagram CONF APPENDIX SS4FR900 BLK DIA.pdf Operational description CONF APPENDIX SS4FR900 OpDes.pdf SHORT-TERM CONFIDENTIAL External Photos SHORT-TERM CONF SS4FR900 EXT Photo.pdf Internal Photos SHORT-TERM CONF SS4FR900 INT Photo.pdf Te s t-Setup Photos SHORT-TERM CONF SS4FR900 Test Photo.pdf User’s Manual SHORT-TERM CONF SS4FR900 Manual.pdf The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Sincerely, Yong Sik, Jang / QA Senior Manager BLUEBIRD INC.
February 20, 2020 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Cover letter FCC ID : SS4FR900 Gentlemen: 1. This device is fixed, so This device does not require a SAR test. 2. This product operates on DC 24 V and PoE 54 V. Sincerely, Yong Sik, Jang / QA Senior Manager BLUEBIRD INC. BLUEBIRD INC. (Dogok-dong, SEI Tower 13,14)39, Eonjuro30-gil, Gangnam-gu, Seoul, South Korea
FCC ID: SS4FR900 Front Rear Copyright ○ c 2020, LTA Co., Ltd .Page 1 of 4 FCC ID: SS4FR900 To p Bottom Copyright ○ c 2020, LTA Co., Ltd .Page 2 of 4 FCC ID: SS4FR900 Left Right Copyright ○ c 2020, LTA Co., Ltd .Page 3 of 4 FCC ID: SS4FR900 ANTENNA : AN970 ANTENNA : ANS970 Copyright ○ c 2020, LTA Co., Ltd .Page 4 of 4
FCC ID: SS4FR900 SA MPLE LABEL & LOCATION Rear BLUEBIRD INC. Model : FR900 Rated Voltage : 24 V(PoE 54 V) FCC ID : SS4FR900 Made in Korea Copyright Ⓒ 2020, LTA Co., Ltd.
FCC ID: SS4FR900 MainBoard–Front MainBoard–Rear Copyright ○ c 2020, LTA Co., Ltd. Page 1 of 4 FCC ID: SS4FR900 Sub Board–Front Sub Board–Rear Copyright ○ c 2020, LTA Co., Ltd. Page 2 of 4 FCC ID: SS4FR900 Sub Board–Front Sub Board–Rear Copyright ○ c 2020, LTA Co., Ltd. Page 3 of 4 FCC ID: SS4FR900 Total internal Copyright ○ c 2020, LTA Co., Ltd. Page 4 of 4
FCC ID: SS4FR900 ATTACHMENT RF EXPOSURE EVULATION 1.1 Limit According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength Magnetic field Strength Power density (mW/cm²) Averaging time 1.34 - 30....................................... 824/f 2.19/f *(180/ f²) 30 30 - 300....................................... 27.5 0.073 0.2 30 300 - 1500.................................... ............... ............... f/1500 30 1500 - 100.000................................. ............... ............... 1.0 30 F = frequency in MHz * = Plane-wave equivalent power density 1.2 MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance Power density at the specific separation: S = PG/(4R 2 π) Where, S = Maximum power density (mW/cm 2 ) P = Power input to the antenna (mW) G = Numeric power gain of the antenna R = Distance to the center of the radiation of the antenna (20 cm = limit for MPE) S = (851.14 * 3.98) / (4 * 20 2 * π) S = 0.674 mW/cm 2 FCC ID: SS4FR900 ATTACHMENT 1.3 MAXIMUM PERMISSIBLE EXPOSURE Prediction - Calculated under the worst-case conditions of each mode. (Measured power 29.30 dBm ± 0.5dB) 900 MHz RFID Mode For 100 MHz to 6 GHz and test separation distances > 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B) [(Power allowed at numeric threshold for 50mm in step a)] + [(test separation distance – 50mm) * (f(MHz)/150] mW = [ 998 ] + [140] * [902.75 / 150 ] = 1840.56 mW Thus, SAR for this device is not required. Max Peak output Power at antenna input terminal 29.30 dBm Max Peak output Power at antenna input terminal 851.14 mW Prediction distance 20 cm Prediction frequency 915.25 MHz Antenna Gain(typical) 6 dBi Antenna Gain(numeric) 3.98 -
Test Report No. : LR500112004A TEST REPORT Test Report No. : LR500112004A Issue Date : April 01, 2020 Applied Standard : FCC Part 15, Subpart B Trade Name : BLUEBIRD INC. Equipment Name : Fixed RFID Reader Model Name : FR900 Serial Number : Identification This test result only responds to the tested sample. It is not allowed to copy this report even partly without the allowance of the test laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This laboratory is accredited by National Radio Research Agency Laboratory and National Voluntary Laboratory Accreditation Program. The tests reported herein have been performed in accordance with its terms of accreditation. Copyright © 2020, LTA CO., LTD. Page 1 of 25 Test Report No. : LR500112004A Revision history Revision Date of issue Test report No. Description 0 01.04.2020 LR500112004A Initial Copyright © 2020, LTA CO., LTD. Page 2 of 25 Test Report No. : LR500112004A >>TABLE OF CONTENTS<< LTA Certification ............................................................................................................... 4 General information’s ......................................................................................................... 6 1- Brief Information ........................................................................................................... 7 2- Test Site Description ..................................................................................................... 11 3- Test Procedure ............................................................................................................. 13 4- List of Equipment Used For the Tests .............................................................................. 16 5- EMISSION ................................................................................................................. 17 5- 1 Conducted Emissions ...................................................................................... 17 5- 2 Radiated Emissions ......................................................................................... 19 Conclusions .................................................................................................................... 25 Copyright © 2020, LTA CO., LTD. Page 3 of 25 Test Report No. : LR500112004A LTA Certification Applicant / Manufacture Company name : BLUEBIRD INC. Address : 3F, 115, Irwon-ro, Gangnam-gu, Seoul, Republic of Korea Telephone / Facsimile : +82-2-2258-9209 Factory Company name : BLUEBIRD INC. Address : 3F, 115, Irwon-ro, Gangnam-gu, Seoul, Republic of Korea Equipment Under Test (EUT) Equipment Name : Fixed RFID Reader Model name : FR900 Serial number : Identification Intended environment : Industrial area Date of receipt : December 20, 2019 EUT condition : Pre-production, not damaged Test Mode : Operating mode Interface ports : DC IN, Ethernet, GPIO, USB Host, Antenna Port #1 ~ #8 Power rating : DC 24 V, PoE/PoE+ Test Voltage : AC 120 V, 60 Hz Model Description - NONE Model Specification - NONE *** To be continued next page *** Copyright © 2020, LTA CO., LTD. Page 4 of 25 Test Report No. : LR500112004A LTA Certification –cont.- Test Performed Test started & completed : March 27 - 28, 2020 Location : LTA Co., Ltd. Test Specification Purpose of the test : Compliance test to the following standard Applied standard : FCC Part 15, Subpart B Classification : Class A Deviations from Standard Test Method : N/A Test Results Measurement Results* Test method Conducted Emissions Complies ANSI C 63.4-2014 Radiated Emissions Complies ANSI C 63.4-2014 * : The compliance statement is based on nominal value only. Modification performed by the lab.; - N.A -We were performed the test according to LTA procedure LTA-QI-04. Laboratory’s Certificate Report number : LR500112004A Issue date : April 01, 2020 This test report is issued under the authority of: The test was supervised by: Young Kyu Shin, Technical Manager Jae Gyu Kang, Test Engineer The results in this report apply only to the sample(s) tested. It is not allowed to copy this report even partly without the allowance of the test laboratory. Copyright © 2020, LTA CO., LTD. Page 5 of 25 Test Report No. : LR500112004A General information’s Purpose This document is based on the Electromagnetic Interference (EMI) tests performed on the “FR900”. The measurements were performed according to the measurement procedure described in ANSI C 63.4-2014.The tests were carried out in order to confirm whether the electromagnetic emissions from the EUT( Equipment Under Test), are within the Class A limits defined in FCC Part 15, Subpart B- “Section 15.107- Conducted limits” and “Section 15.109-Radiated emission limits”. Test Performed Company name : LTA Co., Ltd. Address : 34, Songju-ro 236Beon-gil, Yangji-myeon, Cheoin-gu Yongin-si, Gyeonggi-do 449-822, Korea Telephone : +82-31-323-6008 Facsimile +82-31-323-6010 Measurement uncertainty Conducted Emissions (0.15 to 30 MHz) : ±2.80 [dB] (k=2) Radiated Emissions (30 to 1,000 MHz) : H : ±4.84 [dB] (k=2) V : ±4.92 [dB] (k=2) (1 GHz to 6 GHz) : H : ±5.97 [dB] (k=2) V : ±5.96 [dB] (k=2) (6 GHz to 18 GHz) : H : ±6.20 [dB] (k=2) V : ±6.20 [dB] (k=2) The coverage factor k=2 yields approx. a 95% level of confidence for near-normal distribution typical of most measurement results. Accredited agencies LTA Co., Ltd. Is approved to perform EMC testing by the following agencies: Agency Country Accreditation No. Validity Reference NVLAP U.S.A 200723-0 2020-09-30 ECT accredited Lab. RRA KOREA U.S.A CANADA VIETNAM KR0049 - 2021-04-11 2021-06-16 2021-04-12 RRA accredited Lab. VCCI J APA N C-4948 T-2416 R-4483(10 m) G-10847 2020-09-10 2020-09-10 2020-10-15 2022-06-13 VCCI registration KOLAS KOREA KT551 2021-08-20 KOLAS accredited Lab. Copyright © 2020, LTA CO., LTD. Page 6 of 25 Test Report No. : LR500112004A 1- Brief Information 1-1 Test Summary Parameter …
Text truncated - open the document above for the full version.
Ref. No.: LR500112005A 243 Jubug-Ri,Yangji-Myeon, Yongin-Si, Gyeonggi-Do, Korea 17159 Tel: +82-31-323-6008 Fax: +82-31-323-6010 http://www.ltalab.com Dates of Tests: Dec 20, 2019 ~ April 29, 2020 Test Report S/N: LR500112005A Test Site : LTA CO., LTD. CERTIFICATION OF COMPLIANCE FCC ID APPLICANT Equipment Class : Part 15 Spread Spectrum Transmitter Manufacturing Description : RFID Reader Manufacturer : BLUEBIRD INC. Model name : FR900 Test Device Serial No.: : Identical prototype Rule Part(s) : FCC Part 15.247 Subpart C ; ANSI C-63.4-2014 / ANSI C-63.10-2013 Frequency Range : 902.75 ~ 927.25 MHz RF power : Max 29.30 dBm – Conducted Data of issue : May 6, 2020 This test report is issued under the authority of: The test was supervised by: Ja -Beom Koo, Manager Jae-Hum Yun, Test Engineer This test result only responds to the tested sample. It is not allowed to copy this report even partly without the allowance of the test laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. NVLAP LAB Code.: 200723-0 SS4FR900 BLUEBIRD INC. Copyright ○ c 2018, LTA Co., Ltd. Page 1 of 47 Ref. No.: LR500112005A TABLE OF CONTENTS 1. GENERAL INFORMATION ---------------------------------------------------------------------------- 2. INFORMATION ABOUT TEST ITEM --------------------------------------------------------------- 3. TEST REPORT --------------------------------------------------------------------------------------------- 3.1 SUMMARY OF TESTS ------------------------------------------------------------------------------ 3.2 FREQUENCY HOPPING SYSTEM REQUIREMENTS-------------------------------------------- 3.3 TECHNICAL CHARACTERISTICS TEST ------------------------------------------------------- 3.3.1 CARRIER FREQUENCY SEPARATION ---------------------------------------------------- 3.3.2 NUMBER OF HOPPING FREQUENCIES -------------------------------------------------- 3.3.3 20 dB BANDWIDTH ---------------------------------------------------------------------------- 3.3.4 TIME OF OCCUPANCY (Dwell Time) ------------------------------------------------------- 3.3.5 TRANSMITTER OUTPUT POWER ---------------------------------------------------------- 3.3.6 BAND EDGE ------------------------------------------------------------------------------------- 3.3.7 CONDUCTED SPURIOUS E MISSIONS ----------------------------------------------------- 3.3.8 RADIATED SPURIOUS EMISSIONS ------------------------------------------------------- 3.3.9 AC Conducted Emissions ------------------------------------------------------------------------ APPENDIX APPENDIX TEST EQUIPMENT USED FOR TESTS -------------------------------------------- 3 4 5 5 6 7 7 9 11 15 18 21 23 26 40 47 Copyright ○ c 2018, LTA Co., Ltd. Page 2 of 47 Ref. No.: LR500112005A 1. General information 1-1 Test Performed Company name : LTA Co., Ltd. Address : 243, Jubug-ri,Yangji-Myeon,Youngin-Si, Kyunggi-Do, Korea. 449-822 Web site : http://www.ltalab.com E-mail : [email protected] Telephone : +82-31-323-6008 Facsimile : +82-31-323-6010 Quality control in the testing laboratory is implemented as per ISO/IEC 17025 which is the “General requirements for the competents of calibration and testing laboratory”. 1-2 Accredited agencies LTA Co., Ltd. is approved to perform EMC testing by the following agencies: Agency Country Accreditation No. Validity Reference NVLAP U.S.A 200723-0 2020-09-30 ECT accredited Lab. RRA KOREA KR0049 - EMC accredited Lab. FCC U.S.A 649054 2021-04-11 FCC CAB VCCI J APA N C-4948, 2020-09-10 VCCI registration VCCI J APA N T-2416, 2020-09-10 VCCI registration VCCI J APA N R-4483(10 m), 2020-10-15 VCCI registration VCCI J APA N G-847 2021-12-13 VCCI registration IC CANADA 5799A-1 updating IC filing KOLAS KOREA NO.551 2021-08-20 KOLAS accredited Lab. Copyright ○ c 2018, LTA Co., Ltd. Page 3 of 47 Ref. No.: LR500112005A 2. Information about test item 2-1 Client & Manufacturer Client Company name : BLUEBIRD INC. Address : 3F, 115, Irwon-ro, Gangnam-gu, Seoul, South Korea (SSang-young IT Twin tower-B 7~8F), 531, Dunchon-daero, Jungwon- gu, Seongnam-si, Gyeonggi-do, South Korea Tel / Fax : +82-02-2258-9209 / - 2- 2 Equipment Under Test (EUT) Model name : FR900 Serial number : Identical prototype Date of receipt : Dec 20, 2019 EUT condition : Pre-production, not damaged Antenna type : Dipole Antenna (Max Gain : 6 dBi) Frequency Range : 902.75 ~ 927.25 MHz RF output power : Max 29.30 dBm – Conducted Type of Modulation : FSK Power Source : 24 Vdc 2-3 Tested frequency Bluetooth LOW MID HIGH Frequency (MHz) – 900 MHz RFID 902.75 915.25 927.25 2-4 Ancillary Equipment Equipment Model No. Serial No. Manufacturer Notebook - MS-1736 MSI Copyright ○ c 2018, LTA Co., Ltd. Page 4 of 47 Ref. No.: LR500112005A 3. Test Report 3.1 Summary of tests FCC Part Section(s) Parameter Limit Test Condition Status (note 1) 15.247(a) Carrier Frequency Separation ≥ 2/3 of 20dB BW Conducted C 15.247(a) Number of Hopping Frequencies ≥ 15 channels C 15.247(a) 20 dB Bandwidth 99% Bandwidth − C 15.247(a) Dwell Time ≤ 0.4 seconds C 15.247(b) Transmitter Output Power ≤ 1W for 1Mbps ≤ 125mW for 2,3Mbps C 15.247(d) Conducted Spurious emission > 20 dBc C 15.247(d) Band Edge > 20 dBc C 15.249 / 15.209 Field Strength of Harmonics < 54 dBuV (at 3m) Radiated C 15.109 Field Strength − C 15.207 /15.107 AC Conducted Emissions EN 55022 Line Conducted C 15.203 Antenna requirement − − C Note 1: C=Complies NC=Not Complies NT=Not Tested NA=Not Applicable Note 1: Antenna Requirement The BLUEBIRD INC. FCC ID: SS4FR900 unit complies with the requirement of §15.203. The antenna type is PCB Pattern antenna. The sample was tested according to the following specification: *FCC Parts 15.247; ANSI C-63.4-2014;ANSI C-63.10-2013 *FCC KDB Publication No. 558074 D01 v03r05 *FCC TCB Workshop 2012, April Copyright ○ c 2018, LTA Co., Ltd. Page 5 of 47 Ref. No.: LR500112005A 3.2 Frequency Hopping System Requi…
Text truncated - open the document above for the full version.
FCC ID: SS4FR900 Radiate Emission Copyright ○ c 2019, LTA Co., Ltd. Page 1 of 4 FCC ID: SS4FR900 Copyright ○ c 2019, LTA Co., Ltd. Page 2 of 4 FCC ID: SS4FR900 Copyright ○ c 2019, LTA Co., Ltd. Page 3 of 4 FCC ID: SS4FR900 Conducted Emission Copyright ○ c 2019, LTA Co., Ltd. Page 4 of 4
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.75 MHz - 927.25 MHz | 851.14 mW |
Handheld Managed RFID Computer
Equipment Class
NII - Unlicensed National Information Infrastructure TXKiosk
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Fixed RFID Reader
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Hyebrid Full-Touch Handheld Computer
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Enterprise-Value Full Touch Handheld Computer
Equipment Class
NII - Unlicensed National Information Infrastructure TX