ST2-2X74YStaff Tag IT-740/743/744/745

Centrak, Inc.
Staff Tag IT-740/743/744/745 - FCC ID ST2-2X74Y - Centrak, Inc.
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Oct 18, 2010
Application Purpose
Original Equipment
Date of Application
Oct 18, 2010
Equipment Note
Staff Tag IT-740/743/744/745
Frequency Range
904.00000000 - 926.00000000
Company
Centrak, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CENTRAKSTAFFBADGE– IT-743 (FCC*) Today’s hospitals have a critical need to locate personnel throughout their facilities. They require a reliable RTLS to optimize patient care and provide alerting capabilities to ensure the safety of its personnel. CenTrak’s IT-743 staff badge was developed to meet this need. It was designed using feedback from hospital personnel and includes several unique features that improve upon legacy staff locating technology. The CenTrak Staff Badge, or IT-743 Tag, can be mounted onto the loop used to hold a standard hospital issued employee badge. The Staff Badge is designed to stay with the caregiver, thus eliminating the need for separate processes that require daily tagging of personnel. The Staff Badge is water resistant and can be easily cleaned. Each Staff Badge has three customizable buttons that can be assigned based upon the RTLS use case. About CenTrak DualTrakβ„’ Technology CenTrak’s core RTLS differs from legacy technologies in its combined use of a patented combination of second-generation infrared (Gen2IRβ„’) and active RFID technology called DualTrak. Battery powered Monitors transmit a unique room number using Gen2IR which is received by any tag in that room. The tag communicates the room number and its own unique ID via RF to the CenTrak Location Server using a hospital’s existing wired or Wi-Fi network, where it can be accessed in real- time by hospital personnel and integrated with third party solution providers. Like light, Gen2IR will not pass through walls and does not suffer from traditional infrared line-of- sight limitations. Therefore, when a tag reads a room number, there are no errors. This is certainty- based RTLS. Unlike estimation-based information, certainty-based location data can be used by hospitals to make important improvements to process flow and automate decision making. Most healthcare workflow improvements can only be realized when the location data is certainty-based. DualTrakβ„’ Technology for room and bed level accuracy Three customizable buttons System controlled LED Ultra thin (only 3 mm thin) and light weight Shape and size of a standard hospital issued badge Hole mounts for portrait or landscape to wear behind a standard badge Water resistant and easy to clean Long battery life *See Technical Specs on back for other frequency ranges CenTrak, Inc. 207 Penns Trail Newtown, PA 18940 t: 215-860-2928 e: [email protected] www.centrak.com Β© CenTrak 2010. All Rights Reserved β€’ DualTrak and CenTrak is a trademark of CenTrak, Inc. β€’ Proprietary and Confidential Information Caution: Any changes or modifications not expressly approved by the party responsible for product compliance could void the user's authority to operate the equipment. 902-928 MHz Model #IT-740* 4M codes > 300 feet 2 uW (Average) 3 buttons, LED, low battery YES Operating temperature Storage temperature Sealing -20 C to +70 C -25 C to +80 C Splash resistant Battery type Smart tag featureLow battery indication Lithium CR2325x2 replaceable pack Environmental Power FCC Operating Frequency Range 868-870 MHz Model #ITEU-740 CE Operating Frequency Range Operation Group code & tag ID codes Typical transmission range Field strength Smart Tag features Motion Sensor Loop (portrait or landscape) Lanyard (retractable) Fits standard employment badge mounting (optional) Mounting / Attachment Options Case length Case height Case width 3.40 in (86 mm) 2.125in (55 mm) 0.125 in (3 mm) Case weight Construction (with battery) 1.10 oz (34.02 g) ABS & Poly Carbonate mixture Tag Dimensions Tag cleaning method Warning: Must use CenTrak Disinfection procedure. Other methods may void product warranty. Wipe Cleaning Method Only. See CenTrak Tag Disinfection Guide for Instructions Cleaning CenTrak, Inc. 207 Penns Trail Newtown, PA 18940 t: 215-860-2928 e: [email protected] www.centrak.com CENTRAKSTAFFBADGEIT-743 (FCC*) TECHNICALSPECIFICATIONS This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Modifying or tampering with the transceiver’s or receiver’s internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to use these products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425 , 7,061,428 , 7,378,964 Β© CenTrak 2010. All Rights Reserved β€’ DualTrak and CenTrak is a trademark of CenTrak, Inc. β€’ Proprietary and Confidential Information β€’ 7/10 WARNING:This guide is in draft form and can be changed without notice at any time by CenTrak. Please contact CenTrak prior to commercial use to receive all the necessary latest information about the system.

Cover Letter(s)

207 Penns Trail, Newtown PA 18940 i Tel 215.860.2928 i Fax 215.359.0659 i www.centrak.com Date: 9/16/2010 Compliance Certification Services Certification Division 561F Monterey Road Morgan Hill, CA 95037 To whom it may concern: We, the undersigned, hereby authorize Advanced Compliance Laboratory, Inc., to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Advanced Compliance Laboratory, Inc. on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing Advanced Compliance Laboratory, Inc. as our agent, we still recognize that we are responsible to: β€’ comply with the relevant provisions of the certification program; β€’ make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; β€’ make claims regarding certification only in respect of the scope for which certification has been granted; β€’ do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; β€’ upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; use certification only to indicate the products are certified as being in conformity with specified standards; β€’ endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; β€’ ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; β€’ keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; β€’ take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; September 16, 2010 z Page 2 β€’ document the actions taken This authorization is valid until further written notice from the applicant. Sincerely Yours, Printed Name: Israel Amir Title: CTO Company: Remote Play, Inc.

Cover Letter(s)

207 Penns Trail, Newtown PA 18940 i Tel 215.860.2928 i Fax 215.359.0659 i www.centrak.com Date: September 16, 2010 FCC and IC Confidentiality Request In accordance with 0.459 & 0.457 of CFR 47, please, accept this letter as an official request to have the following kept as confidential for the reference IC IDs IC:6012A-2X74Y, IC:6012A-2X37Y, FCC ID:ST2-2X74Y and FCC ID:ST2-2X37Y. The information provided is for the sole purpose of inclusion as exhibits in the Application for Certificate of the IC IDs stated above: We ask to keep confidential the following Saff Tag (model # IT-740,IT-743), and Hygiene Monitor (model # IT-370, IT-373) documents: y Schematics y Block diagram y Operational description Sincerely, Israel Amir, CTO CenTrak, Inc. 207 Penns Trail Newtown, PA 18940 Tel 215-860-2928

External Photos

FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 21 7.1 Front View FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 22 7.2 Back View

ID Label/Location Info

FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 8 2. PRODUCT LABELING Figure 2.1 FCC ID Label Figure 2.2 Location of Label on the Side of EUT FCC ID: ST2-2X74Y This device complies with part 15 of the FCC Rules. Operating is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Figure 2.1 FCC ID Label (Only FCC ID shown on EUT) FCC Label

Internal Photos

FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 23 7.3 Inside View FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 24 7.4 PCB Component View FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 25 7.5 PCB Foil View

Test Report

ELECTROMAGNETIC EMISSION COMPLIANCE REPORT of STAFF TAG MODEL: IT-740, IT-743, IT-744, IT-745 FCC ID: ST2-2X74Y September 10, 2010 This report concerns (check one): Original grant x Class II change Equipment type: Low Power Intentional Radiator Deferred grant requested per 47 CF 0.457(d)(1)(ii)? yes no x If yes, defer until: (date) Company agrees to notify the Commission by (date) of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? yes no x If no, assumed Part 15, Subpart B for unintentional radiators - the new 47 CFR [10-1-90 Edition] provision. Report prepared for: REMOTE PLAY, INC. Report prepared by: Advanced Compliance Lab Report number: 0048-100812-02-FCC Lab Code: 200101 The test result in this report IS supported and covered by the NVLAP accreditation 6 Randolph Way Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 Advanced Compliance Laboratory FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 2 Table of Contents Report Cover Page .................................................................................................... 1 Table of Contents ...................................................................................................... 2 Figures ....................................................................................................................... 3 1. GENERAL INFORMATION ............................................................................... 4 1.1 Verification of Compliance ...................................................................... 4 1.2 Equipment Modifications ........................................................................ 5 1.3 Product Information ................................................................................ 6 1.4 Test Methodology..................................................................................... 6 1.5 Test Facility .............................................................................................. 6 1.6 Test Equipment ........................................................................................ 6 1.7 Statement of the Document Use............................................................... 7 2. PRODUCT LABELING........................................................................................ 8 3. SYSTEM TEST CONFIGURATION................................................................... 9 3.1 Justification .............................................................................................. 9 3.2 Special Accessories ................................................................................... 9 3.3 Configuration of Tested System .............................................................. 9 4. SYSTEM SCHEMATICS ..................................................................................... 12 5. RADIATED EMISSION DATA........................................................................... 13 5.1 Field Strength Calculation....................................................................... 13 5.2 Test Methods and Conditions.................................................................. 13 5.3 Test Data .................................................................................................. 13 6. EUT RECEIVING MODE VERIFICATION ...................................................... 18 7. PHOTOS OF TESTED EUT................................................................................. 19 FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 3 Figures Figure 2.1 FCC ID Label........................................................................................... 8 Figure 2.2 Location of Label on Back of the EUT.................................................... 8 Figure 3.1 Radiated Test Setup, Position 1 .............................................................. 10 Figure 3.2 Radiated Test Setup, Position 2 .............................................................. 10 Figure 3.3 Radiated Test Setup, Position 3 .............................................................. 11 Figure 4.1 EUT Schematics ....................................................................................... 12 Figure 7.1 Front View ............................................................................................... 20 Figure 7.2 Back View ................................................................................................ 21 Figure 7.3 Inside View............................................................................................... 22 Figure 7.4 PCB Component View............................................................................. 23 Figure 7.5 PCB Foil View......................................................................................... 24 FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 4 1. GENERAL INFORMATION 1.1 Verification of Compliance EUT: STAFF TAG Model: IT-740, IT-743, IT-744, IT-745 Applicant: REMOTE PLAY, INC. Test Type: FCC Part 15C CERTIFICATION Result: PASS Tested by: ADVANCED COMPLIANCE LABORATORY Test Date: August 12-September 10, 2010 Report Number: 0048-100812-02-FCC The above equipment was tested by Compliance Laboratory, Advanced Technologies, Inc. for compliance with the requirement set forth in the FCC rules and regulations Part 15 subpart C. This said equipment in the configuration described in the report, shows the maximum emission levels emanating from equipment are within the compliance requirements. The estimated uncertainty of the test result is given as following. The method of uncertainty c…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 11 Figure 3.1 Radiated Test Setup, position 1 Figure 3.2 Radiated Test Setup, position 2 FCC ID: ST2-2X74Y β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 12 Figure 3.3 Radiated Test Setup, position 3

Contact Information

Applicant

Sherre Staves(VP)
[email protected]215-860-2928Fax: 215-860-2928

Technical Contact

Advanced Compliance Laboratory, Inc.Wei Li
[email protected]9089279288

6 Randolph Way Β· Hillsborough, New Jersey Β· United States

Test Firm

Advanced Compliance LaboratoryWei Li
[email protected]908-927-9288Fax: 908-927-0728

Technical Specifications

#Rule PartsFrequency RangePower Output
115C904 MHz - 926 MHz-
Confidentiality
Long Term

Other Applications from Centrak, Inc.

ST2-IT7210

Safety 2.0 Bracelet

Feb 13, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
BLE MultiMode Badge - FCC ID ST2-CTHSB760 - Centrak, Inc.
ST2-CTHSB760

BLE MultiMode Badge

Mar 17, 2024

Equipment Class

DTS - Digital Transmission System
Man Down - FCC ID ST2-5MDT000371 - Centrak, Inc.
ST2-5MDT000371

Man Down

Apr 06, 2022

Equipment Class

DTS - Digital Transmission System
Hand Hygiene Sensor - FCC ID ST2-IT376B - Centrak, Inc.
ST2-IT376B

Hand Hygiene Sensor

Mar 11, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Mini MM Patient/Asset Tag ITD/U-766E/H, -7622E/H,-7623E/H - FCC ID ST2-ITD766 - Centrak, Inc.
ST2-ITD766

Mini MM Patient/Asset Tag ITD/U-766E/H, -7622E/H,-7623E/H

Jun 29, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter