Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Document # GUD20101010-03 CenTrak Inc. ο§ Phone 215.860.2928 ο§ www.centrak.com 03/17/2013 Β© CenTrak 2013. All Rights Reserved.. Proprietary and Confidential Information Drop Box Monitor Part #IT β 317 (2.0 system) rak.com www.centr The CenTrak Drop Box Monitor is designed to support the management of patient tags that are ready to be cleared from the CenTrak System. It can be utilized at nurseβs stations or in discharge areas to indicate that a patient has left the facility and that a tag can be re β assigned. This automa ted disassociation feature is an important component of the system. When a patient leaves the facility, the tag is removed and dropped into the box. The tag drop is automatically detected by the system and can be translated into a discharge event. The number of tags in the box can be queried at any time. Alerts can be generated when the number of tags approaches a predetermined maximum and sent to the individuals responsible for putting tags back into service. Included in box: ο· Mini monitor assembly ο· 4 screws How it works ο· The monitor should be treated just like other monitors except it does not require profile setting. The IT β 317 can accept all profiles that do not require noise setting (0 β 9). ο· The monitor will start emitting signal whe n drop box bin is inserted. The monitor comes in an assembly with dry contacts to connect to the drop box switch. Technical Specifications ο· Operating Temperature β 10 C to +50C ο· FCC ID: ST2 β IT317 , IC: 601 2A β IT317 , ο· FCC Operati n g Frequency Range 902 β 928 MHz ο· Battery life exp ectancy is 2.5 years* *Battery expectancy is only an estimate and can vary based on operating conditions, type of batteries used and method of operation (estimate assumes operating temperature of 25C and CenTrak supplied batteries). Physical Installation Step 1 β Cut and remove fuse. The wires from the switch must be cut to length sufficient to reach the dry contact junction (about 6 inches). Step 2 β Attach monitor assembly with 4 provided screws. Attach switch wires to dry contact junction. FCC and IC Statements: THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES AND INDUSTRY CANADA LICENSE-EXEMPT RSS STANDARD(S). OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Modifying or tampering with the transceiverβs or receiverβs internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to use these products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964, 7,619,532. L β utilisation de ce dispositif est autorisΓ©e seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) lβ utilisateur du dispositif doit Γ©tre prΓͺt Γ accepter tout brouillage radioΓ©lectrique reΓ§u, mΓͺme si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.
Date: April 10, 2013 FCC and IC Confidentiality Request In accordance with 0.459 & 0.457 of CFR 47, please, accept this letter as an official request to have the following kept as confidential for the reference IDs: IC: 6012A-IT317 Model number: IT-317 And: FCC: ST2-IT317 The information provided is for the sole purpose of inclusion as exhibits in the Application for Certificate of the FCC & IC IDs stated above: We ask to keep confidential the following DIM (model# IT-317) documents: x Schematics and Parts List x Block Diagram x Operational description Sincerely, Israel Amir, CTO CenTrak, Inc. 5 Caufield Place, Ste 102 Newtown, PA 18940 215.860.2928
Date: 6/27/2012 To whom it may concern: We, the undersigned, hereby authorize Wei Li, Advanced Compliance Laboratory, Inc., to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Advanced Compliance Laboratory, Inc. on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing Advanced Compliance Laboratory, Inc. as our agent, we still recognize that we are responsibl e to: β’ comply with the relevant provisions of the certification program; β’ make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; β’ make claims regarding certification only in respect of the scope for which certification has been granted; β’ do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; β’ upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; use certification only to indicate the products are certified as being in conformity with specified standards; β’ endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; β’ ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; β’ keep a record of all complaints made known to the us relating to the productβs compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; β’ take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; 5 Caufield Place Ste 102, Newtown PA 18940 i Tel 215.860.2928 i Fax 215.359.0659 i www.centrak.com β’ document the actions taken This authorization is valid until further written notice from the a pplicant. Sincerely Yours, Printed Name: Israel Amir Title: CTO Company: CenTrak, Inc. z Page 2
Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 21 7.1 Front View Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 22 7.2 Back View
Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 8 2. PRODUCT LABELING Figure 2.1 FCC ID Label Figure 2.2 Location of Label on the Side of EUT Centrak Drop Box Monitor Model No.: IT-317 FCC ID: ST2-IT317 IC: 6012A-IT317 This device complies with part 15 of the FCC Rules and IC RSS-210 & RSS-Gen Rules.. Operating is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Figure 2.2 Location of the Label ID Label Figuare 2.1 FCC/IC ID Label (Only ID show on the EUT)
Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 23 7.3 Inside View Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 24 7.4 PCB Component Side View Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 25 7.5 PCB Foil Side View
ELECTROMAGNETIC EMISSION COMPLIANCE REPORT of DROP BOX MONITOR MODEL: IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 April 2, 2013 This report concerns (check one): Original grant Class II change Equipment type: Low Power Intentional Radiator Test Specifications: ____FCC Part 15C Sec. 15.249 ____Industry Canada RSS-210 (Issue 8) & RSS-Gen (Issue 3) Deferred grant requested per 47 CF 0.457(d)(1)(ii)? yes no x If yes, defer until: (date) Company agrees to notify the Commission by (date) of the intended date of announcement of the product so that the grant can be issued on that date. Report prepared for: CENTRAK, INC. Report prepared by: Advanced Compliance Lab Report number: 0048-130227-01 Lab Code: 200101 The test result in this report IS supported and covered by the NVLAP accreditation 6 Randolph Way Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 Advanced Compliance Laboratory Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 2 Table of Contents Report Cover Page .................................................................................................... 1 Table of Contents ...................................................................................................... 2 Figures ....................................................................................................................... 3 1. GENERAL INFORMATION .................................................................................. 4 1.1 Verification of Compliance ......................................................................... 4 1.2 Equipment Modifications ............................................................................ 5 1.3 Product Information ................................................................................... 6 1.4 Test Methodology ...................................................................................... 6 1.5 Test Facility ............................................................................................... 6 1.6 Test Equipment .......................................................................................... 6 1.7 Statement for the Document Use ................................................................ 7 2. PRODUCT LABELING .......................................................................................... 8 3. SYSTEM TEST CONFIGURATION ...................................................................... 9 3.1 Justification ................................................................................................ 9 3.2 Special Accessories .................................................................................... 9 3.3 Configuration of Tested System.................................................................. 9 4. SYSTEM SCHEMATICS ....................................................................................... 13 5. RADIATED EMISSION DATA ............................................................................. 14 5.1 Field Strength Calculation .......................................................................... 14 5.2 Test Methods and Conditions ..................................................................... 14 5.3 Test Data ................................................................................................... 14 6. EUT RECEIVING MODE VERIFICATION .......................................................... 19 7. PHOTOS OF TESTED EUT ................................................................................... 20 Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 3 Figures Figure 2.1 FCC/IC ID Label ..................................................................................... 8 Figure 2.2 Location of Label ..................................................................................... 8 Figure 3.1 Radiated Test Setup ................................................................................. 10 Figure 4.1 EUT Schematics ....................................................................................... 12 Figure 7.1 Front View ............................................................................................... 21 Figure 7.2 Back View ................................................................................................ 22 Figure 7.3 Inside View ............................................................................................... 23 Figure 7.4 PCB Component Side View ..................................................................... 24 Figure 7.5 PCB Foil Side View .................................................................................. 25 Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 4 1. GENERAL INFORMATION 1.1 Verification of Compliance EUT: DROP BOX MONITOR Model: IT-317 Applicant: CENTRAK, INC. Test Type: FCC Part 15.249 & IC RSS-210 (Issue 8) A2.9 & RSS-Gen (Issue 3) Result: PASS Tested by: ADVANCED COMPLIANCE LABORATORY Test Date: April 2, 2013 Report Number: 0048-130227-01 The above equipment was tested by Compliance Laboratory, Advanced Technologies, Inc. for compliance with the requirement set forth in the FCC rules and regulations Part 15 subpart C. This said equipment in the configuration described in the report, shows the maximum emission levels emanating from equipment are within the compliance requirements. The estimated uncertainty of the test result is given as following. The method of uncertainty calculation is provided in Advanced Compliance Lab. Doc. No. 004β¦
Text truncated - open the document above for the full version.
Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 10 Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 11 Drop Box Monitor Model No. IT-317 FCC ID: ST2-IT317 IC:6012A-IT317 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 12 Figure 3.1 Radiated Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 904 MHz - 926 MHz | - |
Safety 2.0 Bracelet
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
BLE MultiMode Badge
Equipment Class
DTS - Digital Transmission System
Man Down
Equipment Class
DTS - Digital Transmission System
Hand Hygiene Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Mini MM Patient/Asset Tag ITD/U-766E/H, -7622E/H,-7623E/H
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter