FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Centrak, Inc./
  3. ST2-IT373A

ST2-IT373AHYGIENE MONITOR IT-373A

Centrak, Inc.
HYGIENE MONITOR IT-373A - FCC ID ST2-IT373A - Centrak, Inc.
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Jan 03, 2013
Application Purpose
Original Equipment
Date of Application
Jan 03, 2013
Equipment Note
HYGIENE MONITOR IT-373A
Frequency Range
904.00000000 - 926.00000000
Company
Centrak, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—
β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Β© CenTrak 2012. All Rights Reserved. Proprietary and Confidential. 12/12 CenTrak, Inc. 5 Caufield Place, Suite 102 Newtown, PA 18940 t: 215‐860‐2928 e: [email protected] www.centrak.com CenTrak Hygiene Monitor IT‐373A* β€’Automatically tracks hand hygiene compliance at the caregiver level β€’Collects data on all events at hand washing stations β€’Mounts to any alcohol or soap dispenser β€’Multiple mechanisms to activate the dispenser including trigger (level switch), proximity and motion sensor β€’Works in conjunction with CenTrak’s full RTLS and with CenTrak’s Hand Hygiene Badges. The CenTrak Hygiene Compliance System leverages the Hygiene Monitor to automatically monitor usage by caregivers along with their entry and exit to patient care areas. It eliminates costly manual monitoring and identified and proactively alerts caregivers who enter patient care environments without proper hand hygiene, to assist in compliance and behavior modification. The battery powered IT‐373A Hygiene Monitors can be mounted to any dispenser, canister, or pump to track their usage. It automatically communicates a specific caregiver’s badge ID and entry to an exit from patient care areas along with hand hygiene events, based upon hospital determined compliance business rules. The Hygiene Monitor communicates each event to the network which records each caregiver’s compliance performance. All of the recorded data is stored on CenTrak’s local or hosted server and can be accessed by third party compliance management and reporting solutions. The Red and Green LED indicators work by flashing a red light when the dispenser is activated and then by flashing a green light to indicate the monitor and Tag have interacted and the Tag ID has been received. There is also a tamper proof button on the back of the Hygiene Monitor, that if removed from a dispenser sends an alert to the system. The IT‐373A captures all hand hygiene events whether or not a caregiver is in direct line of sight of the Hygiene Monitor using a combination of technologies. Unlike other solutions hand hygiene compliance solutions, CenTrak is able to capture 100% of clinical hand washing events without errors. The battery operation and the simple mounting mechanism allows for quick and low cost installation of the device at hand hygiene stations. *IT‐373A is for use with the CenTrak 2.0 system. Order IT‐371 for use with the 1.0 system. IT‐373A CenTrak Hygiene Monitor shown attached to a dispenser IT‐373A CenTrak Hygiene Monitor Β© CenTrak 2012. All Rights Reserved. Proprietary and Confidential. 12/12 CenTrak, Inc. 5 Caufield Place, Suite 102 Newtown, PA 18940 t: 215‐860‐2928 e: [email protected] www.centrak.com CenTrak Hygiene Monitor IT‐373A* Technical Specifications Operation FCC Operating Frequency Range902‐928 MHz (Model #IT‐373A)* CE Operating Frequency Range868‐870 MHz (Model #ITEU‐373A)* Maximum transmission power1 mW peak Low Frequency YES, 125 KHz Indicators LED IndicatorsGreen LED, Red LED Enclosure Case width2.37 in (60.25mm) Case height4.1 in (104 mm) Case depth0.75 in (19 mm) ConstructionABS Plastic Environmental Operating Temperature0 C to +50 C Storage temperature‐30 C to +70 C Operating Humidity10% to 90% non‐condensing Power Battery type2 x CR123A (Part # ITA‐368) Note: Must use CenTrak Disinfection procedure. Other methods may void product warranty. *IT‐373A is for use with the CenTrak 2.0 system. Order IT‐371 for use with the 1.0 system. Activation Sensors Proximity and/or MotionOptional configurations Low Frequency RangeUp to 4 feet IT‐373A CenTrak Hygiene Monitor IT‐373A CenTrak Hygiene Monitor shown attached to a dispenser This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Modifying or tampering with the transceiver’s or receiver’s internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to use these products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964, 7,619,532. L β€˜ utilisation de ce dispositif est autorisΓ©e seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit Γ©tre prΓͺt Γ  accepter tout brouillage radioΓ©lectrique reΓ§u, mΓͺme si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.

Cover Letter(s)

Date: 6/27/2012 To whom it may concern: We, the undersigned, hereby authorize Wei Li, Advanced Compliance Laboratory, Inc., to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Advanced Compliance Laboratory, Inc. on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing Advanced Compliance Laboratory, Inc. as our agent, we still recognize that we are responsibl e to: β€’ comply with the relevant provisions of the certification program; β€’ make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; β€’ make claims regarding certification only in respect of the scope for which certification has been granted; β€’ do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; β€’ upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; use certification only to indicate the products are certified as being in conformity with specified standards; β€’ endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; β€’ ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; β€’ keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; β€’ take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; 5 Caufield Place Ste 102, Newtown PA 18940 i Tel 215.860.2928 i Fax 215.359.0659 i www.centrak.com β€’ document the actions taken This authorization is valid until further written notice from the a pplicant. Sincerely Yours, Printed Name: Israel Amir Title: CTO Company: CenTrak, Inc. z Page 2

Cover Letter(s)

Date: December 26, 2012 FCC and IC Confidentiality Request In accordance with 0.459 & 0.457 of CFR 47, please, accept this letter as an official request to have the following kept as confidential for the reference IDs: IC: 6012A-IT373A Model number: IT-373A And: FCC: ST 2-IT373A The information provided is for the sole purpose of inclusion as exhibits in the Application for Certificate of the FCC & IC IDs stated above: We ask to keep confidential the following Tag (model# IT-373A) documents: ο‚· Schematics ο‚· Block Diagram ο‚· Operational description Sincerely, Israel Amir, CTO CenTrak, Inc. 5 Caufield Place, Ste 102 Newtown, PA 18940 215.860.2928

External Photos

FCC ID: ST2-IT373A EUT Side Photos: Small PCB:

External Photos

FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 21 7.1 Front View FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 22 7.2 Back View

ID Label/Location Info

FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 8 2. PRODUCT LABELING Figure 2.1 FCC ID Label Figure 2.2 Location of Label on the Side of EUT FCC ID: ST2-IT373A This device complies with part 15 of the FCC Rules. Operating is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Figure 2.2 Location of the Label FCC Label Figuare 2.1 FCC ID Label (Only FCC ID show on EUT)

Internal Photos

FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 23 7.3 Inside View FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 24 7.4 125KHz Antenna and PCB Component Side View FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 25 7.5 PCB Foil Side View

Test Report

ELECTROMAGNETIC EMISSION COMPLIANCE REPORT of Hygiene Monitor (LF DIM) MODEL: IT-373A FCC ID: ST2-IT373A December 04, 2012 This report concerns (check one): Original grant x Class II change Equipment type: Low Power Intentional Radiator Deferred grant requested per 47 CF 0.457(d)(1)(ii)? yes no x If yes, defer until: (date) Company agrees to notify the Commission by (date) of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? yes no x If no, assumed Part 15, Subpart B for unintentional radiators - the new 47 CFR [10-1-90 Edition] provision. Report prepared for: CENTRAK, INC. Report prepared by: Advanced Compliance Lab Report number: 0048-121203-01-FCC Lab Code: 200101 The test result in this report IS supported and covered by the NVLAP accreditation 6 Randolph Way Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 Advanced Compliance Laboratory FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 2 Table of Contents Report Cover Page .................................................................................................... 1 Table of Contents ...................................................................................................... 2 Figures ....................................................................................................................... 3 1. GENERAL INFORMATION ........................................................................................ 4 1.1 Verification of Compliance .............................................................................................. 4 1.2 Equipment Modifications ................................................................................................. 5 1.4 Test Methodology ............................................................................................................ 6 1.5 Test Facility ..................................................................................................................... 6 1.6 Test Equipment................................................................................................................ 6 1.7 Statement for the Document Use ...................................................................................... 7 2. PRODUCT LABELING .................................................................................................................. 8 3. SYSTEM TEST CONFIGURATION ....................................................................... 9 3.1 Justification ..................................................................................................................... 9 3.2 Special Accessories .......................................................................................................... 9 3.3 Configuration of Tested System ....................................................................................... 9 4. SYSTEM SCHEMATICS ............................................................................................... 12 5. RADIATED EMISSION DATA ................................................................................. 13 5.1 Field Strength Calculation ............................................................................................... 13 5.2 Test Methods and Conditions ........................................................................................... 13 5.3 Test Data ......................................................................................................................... 13 5.4 125KHz Transmission Radiated Test Data ....................................................................... 17 6. EUT RECEIVING MODE VERIFICATION ....................................................... 19 7. PHOTOS OF TESTED EUT ......................................................................................... 20 FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 3 Figures Figure 2.1 FCC ID Label ........................................................................................... 8 Figure 2.2 Location of Label on Back of the EUT.................................................... 8 Figure 3.1 Radiated Test Setup ................................................................................. 10 Figure 4.1 EUT Schematics ....................................................................................... 12 Figure 7.1 Front View ............................................................................................... 19 Figure 7.2 Back View ................................................................................................ 20 Figure 7.3 Inside View ............................................................................................... 21 Figure 7.4 125KHz Antenna and PCB Component Side View ................................ 22 Figure 7.5 PCB Foil Side View .................................................................................. 23 FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 4 1. GENERAL INFORMATION 1.1 Verification of Compliance EUT: Hygiene Monitor (LF DIM) Model: IT-373A Applicant: CENTRAK, INC. Test Type: FCC Part 15C CERTIFICATION Result: PASS Tested by: ADVANCED COMPLIANCE LABORATORY Test Date: December 04, 2012 Report Number: 0048-121203-01-FCC The above equipment was tested by Compliance Laboratory, Advanced Technologies, Inc. for compliance with the requirement set forth in the FCC rules and regulations Part 15 subpart C. This said equipment in the configuration described in the report, shows the maximum emission levels emanating from equipment are within the compliance requir…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 10 FCC ID: ST2-IT373A β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€”β€” Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927-0728 11 Figure 3.1 Radiated Test Setup

Contact Information

Applicant

Sherre Staves(VP)
[email protected]215-860-2928Fax: 215-860-2928

Test Firm

Advanced Compliance LaboratoryWei Li
[email protected]908-927-9288Fax: 908-927-0728

Technical Specifications

#Rule PartsFrequency RangePower Output
115C904 MHz - 926 MHz-
Confidentiality
Long Term

Other Applications from Centrak, Inc.

ST2-IT7210

Safety 2.0 Bracelet

Feb 13, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
BLE MultiMode Badge - FCC ID ST2-CTHSB760 - Centrak, Inc.
ST2-CTHSB760

BLE MultiMode Badge

Mar 17, 2024

Equipment Class

DTS - Digital Transmission System
Man Down - FCC ID ST2-5MDT000371 - Centrak, Inc.
ST2-5MDT000371

Man Down

Apr 06, 2022

Equipment Class

DTS - Digital Transmission System
Hand Hygiene Sensor - FCC ID ST2-IT376B - Centrak, Inc.
ST2-IT376B

Hand Hygiene Sensor

Mar 11, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Mini MM Patient/Asset Tag ITD/U-766E/H, -7622E/H,-7623E/H - FCC ID ST2-ITD766 - Centrak, Inc.
ST2-ITD766

Mini MM Patient/Asset Tag ITD/U-766E/H, -7622E/H,-7623E/H

Jun 29, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter