Β© CenTrak 2013. All Rights Reserved. Proprietary and Confidential. CenTrak, Inc. 125 Pheasant Run Newtown, PA 18940 t: 215β860β2928 e: [email protected] www.centrak.com ITβ723E Patient Ta g β’Gen2IRβ’ Technology for ClinicalβGrade Locatingβ’ applications β’Customizable button β’LED remote activation β’Small size, lightweight, and low cost β’Water resistant and easy to clean β’Low power consumption for long lasting battery life β’Attaches with most standard patient wristbands β’Low Frequency (LF) sensor β’Compatible with CenTrakβs Low Frequency Exciters to create choke points. Healthcare facilities have a critical need for the wireless monitoring of patients to ensure safety and improve workflow. CenTrakβs ClinicalβGrade Locatingβ’ technology was developed to meet these needs when used with automated workflow and bed management applications. The CenTrak Tag is securely associated with a patient wearing the tag to help with identification before medication is administered or a medical procedure is performed, to confirm identity and reduce errors. The tags enable patients to have increased mobility while improving their safety by quickly alerting staff if patients enter or leave restricted areas. Patients enjoy having the freedom and flexibility to move as supported by their care plan. The ITβ723E tag utilizes CenTrakβs Gen2IRβ’ and Low Frequency RF to support ClinicalβGrade Locatingβ’ applications. Gen2IRβ’ enables certaintyβbased accuracy at the bedβ, bayβand chairβlevel, rapid location update speeds and extreme battery life. Low Frequency RF supports patient egress and wander prevention while reducing tag loss. This enables hospitals and healthcare administrators to make decisions based on facts about where and when their people and resources are located. The ITβ723E tag provides the ability to monitor patients at any time anywhere in a facility. This single tag can be used to track, locate, protect and identify a patient in seconds. The ITβ723E is a battery powered RF/IR Tag that attaches to patients who need to be tracked, located, and identified. Tags may be worn on standard issued medical ID bracelets. With a modular design and low price, tags provide an economical solution to a wide variety of patient management challenges. ITβ723E Patient Tag ITβ723E Patient Tag shown with attachment accessory Β© CenTrak 2013. All Rights Reserved. Proprietary and Confidential. CenTrak, Inc. 125 Pheasant Run Newtown, PA 18940 t: 215β860β2928 e: [email protected] www.centrak.com ITβ723E Patient Ta g Technical Specifications Operation FCC Operating Frequency Range902β928 MHz (Model #ITβ723E) CE Operating Frequency Range868β870 MHz (Model #ITEUβ723E) Group code & tag ID codes8M codes Outdoor transmission range> 300 feet Average transmission power2 uW (average) Gen2IR sensorYES Low Frequency sensorYES, 125 KHz Smart tag features1 button, LED, low battery indicator Motion SensorYES Attachment Options Wrist StrapModel # ITAβ754 Tag Dimensions Case width1.5 in (38.1 mm) Case height1.98 in (50.3 mm) Case width0.6 in (15 mm) Case weight (with battery) 0.77 oz (21.8 g) ConstructionABS & Poly Carbonate mixture Environmental/Cleaning Operating Temperature0 C to +70 C Storage temperatureβ25 C to +80 C SealingSplash & Water resistant Tag cleaning methodWipe cleaning method only. See CenTrak Tag Disinfection Guide for Instructions. Power Battery typeLithium CR2430 Smart tag featureLow battery indication ITAβ754 Wrist Strap This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Modifying or tampering with the transceiverβs or receiverβs internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to use these products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964, 7,619,532. L β utilisation de ce dispositif est autorisΓ©e seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) lβ utilisateur du dispositif doit Γ©tre prΓͺt Γ accepter tout brouillage radioΓ©lectrique reΓ§u, mΓͺme si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. ITβ723E Patient Tag
Date: 6/27/2013 To whom it may concern: We, the undersigned, hereby authorize Wei Li, Advanced Compliance Labo ratory, Inc., to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Advanced Compliance Laboratory, Inc. on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are no t subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). I n authorizing Advanced Compliance Laboratory, Inc. as our agent, we still recognize that we are responsibl e to: β’ comply with the relevant provisions of the certification program; β’ make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; β’ make claims regarding certification only in respect of the scope for which certification has been granted; β’ do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; β’ upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; use certification only to indicate the products are certified as being in conformity with specified standards; β’ endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; β’ ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; β’ keep a record of all complaints made known to the us relating to the productβs compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; β’ take appropriate action with respect to such complaints and any deficiencies found in products or se rvices that affect compliance with the requirements for certification; 5 Caufield Place Ste 102, Newtown PA 189 40 i Tel 215.860.2928 i Fax 215.359.0659 i www.centrak.com β’ document the actions taken This authorization is valid until further written notice from the a pplicant. Sincerely Yours, Printed Name: Israel Amir Title: CTO Company: CenTrak, Inc. z Page 2
Date: June 27, 2013 FCC and IC Confidentiality Request In accordance with 0.459 & 0.457 of CFR 47, please, accept this letter as an official request to have the following kept as confidential for the reference IDs: IC: 6012A-IT723E Model numbers: IT-723E And: FCC: ST2-IT723E The information provided is for the sole purpose of inclusion as exhibits in the Application for Certificate of the FCC & IC IDs stated above: We ask to keep confidential the following Tag (model# IT-723E) documents: ο· Schematics ο· Block Diagram ο· Operational description Sincerely, Israel Amir, CTO CenTrak, Inc. 125 Pheasant Run Newtown, PA 18940 215.860.2928
PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 24 7.1 Front View PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 25 7.2 Back View
PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 8 2. PRODUCT LABELING Figure 2.1 FCC ID Label Figure 2.2 Location of Label on the Side of EUT Centrak PATIENT TAG Model No.: IT-723E FCC ID: ST2-IT723E IC: 6012A-IT723E This device complies with part 15 of the FCC Rules and IC RSS-210 & RSS-Gen Rules.. Operating is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Figure 2.2 Location of the Label ID Label Figuare 2.1 FCC/IC ID Label (Only ID show on the EUT)
PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 26 7.3 Inside View PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 27 7.4 PCB Component Side View PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 28 7.5 PCB Foil Side View
ELECTROMAGNETIC EMISSION COMPLIANCE REPORT of PATIENT TAG MODEL: IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E August 06, 2013 This report concerns (check one): Original grant Class II change Equipment type: Low Power Intentional Radiator Test Specifications: ____FCC Part 15C Sec. 15.249 ____Industry Canada RSS-210 (Issue 8) & RSS-Gen (Issue 3) Deferred grant requested per 47 CF 0.457(d)(1)(ii)? yes no x If yes, defer until: (date) Company agrees to notify the Commission by (date) of the intended date of announcement of the product so that the grant can be issued on that date. Report prepared for: CENTRAK, INC. Report prepared by: Advanced Compliance Lab Report number: 0048-130729-01 Lab Code: 200101 The test result in this report IS supported and covered by the NVLAP accreditation 6 Randolph Way Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 Advanced Compliance Laboratory PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 2 Table of Contents Report Cover Page .................................................................................................... 1 Table of Contents ...................................................................................................... 2 Figures ....................................................................................................................... 3 1. GENERAL INFORMATION .................................................................................. 4 1.1 Verification of Compliance ......................................................................... 4 1.2 Equipment Modifications ............................................................................ 5 1.3 Product Information ................................................................................... 6 1.4 Test Methodology ...................................................................................... 6 1.5 Test Facility ............................................................................................... 6 1.6 Test Equipment .......................................................................................... 6 1.7 Statement for the Document Use ................................................................ 7 2. PRODUCT LABELING .......................................................................................... 8 3. SYSTEM TEST CONFIGURATION ...................................................................... 9 3.1 Justification ................................................................................................ 9 3.2 Special Accessories .................................................................................... 9 3.3 Configuration of Tested System.................................................................. 9 4. SYSTEM SCHEMATICS ....................................................................................... 15 5. RADIATED EMISSION DATA ............................................................................. 16 5.1 Field Strength Calculation .......................................................................... 16 5.2 Test Methods and Conditions ..................................................................... 16 5.3 Test Data ................................................................................................... 16 6. EUT RECEIVING MODE VERIFICATION .......................................................... 22 7. PHOTOS OF TESTED EUT ................................................................................... 22 PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 3 Figures Figure 2.1 FCC/IC ID Label ..................................................................................... 8 Figure 2.2 Location of Label ..................................................................................... 8 Figure 3.1 Radiated Test Setup ................................................................................. 10 Figure 4.1 EUT Schematics ....................................................................................... 12 Figure 7.1 Front View ............................................................................................... 21 Figure 7.2 Back View ................................................................................................ 22 Figure 7.3 Inside View ............................................................................................... 23 Figure 7.4 PCB Component Side View ..................................................................... 24 Figure 7.5 PCB Foil Side View .................................................................................. 25 PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 4 1. GENERAL INFORMATION 1.1 Verification of Compliance EUT: PATIENT TAG Model: IT-723E Applicant: CENTRAK, INC. Test Type: FCC Part 15.249 & IC RSS-210 (Issue 8) A2.9 & RSS-Gen (Issue 3) Result: PASS Tested by: ADVANCED COMPLIANCE LABORATORY Test Date: August 06, 2013 Report Number: 0048-130729-01 The above equipment was tested by Compliance Laboratory, Advanced Technologies, Inc. for compliance with the requirement set forth in the FCC rules and regulations Part 15 subpart C. This said equipment in the configuration described in the report, shows the maximum emission levels emanating from equipment are within the compliance requirements. The estimated uncertainty of the test result is given as following. The method of uncertainty calculation is provided in Advanced Compliance Lab. Doc. No. 0048-01-01.β¦
Text truncated - open the document above for the full version.
PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 11 PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 12 PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 13 PATIENT TAG Model No. IT-723E FCC ID: ST2-IT723E IC:6012A-IT723E βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 14 Figure 3.1 Radiated Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 904 MHz - 926 MHz | - |
Safety 2.0 Bracelet
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
BLE MultiMode Badge
Equipment Class
DTS - Digital Transmission System
Man Down
Equipment Class
DTS - Digital Transmission System
Hand Hygiene Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Mini MM Patient/Asset Tag ITD/U-766E/H, -7622E/H,-7623E/H
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter