Β© CenTrak 2014. All Rights Reserved. Proprietary and Confidential. IT-725 Single-Use Patient Tag β’Practical patient tracking solution with low cost, fully waterproof tags which may either be discarded or recycled β’Gen2IRβ’ Technology for Clinical-Grade Locatingβ’ applications β’Thin, small size, lightweight β’Designed to integrate with existing hospital ID bracelets β’Operates for 30 days β perfect more most patient flow applications Healthcare facilities have a critical need for the wireless monitoring of patients to ensure safety and improve workflow. CenTrakβs Clinical-Grade Locatingβ’ technology was developed to meet these needs when used with automated workflow and bed management applications. The CenTrak Tag is securely associated with a patient wearing the tag to help with identification before medication is administered or a medical procedure is performed, to confirm identity and reduce errors. The tags enable patients to have increased mobility while improving their safety by quickly alerting staff if patients enter or leave restricted areas. Patients enjoy having the freedom and flexibility to move as supported by their care plan. The IT-725 tag utilizes CenTrakβs Gen2IRβ’ to support Clinical-Grade Locatingβ’ applications. Gen2IRβ’ enables certainty-based accuracy at the bed-, bay- and chair-level. This empowers hospitals and healthcare administrators to make decisions based on facts about where and when their people and resources are located. The IT-725 tag provides the ability to monitor patients at any time anywhere in a facility. This single tag can be used to track, locate, protect and identify a patient in seconds. Tags may be worn on standard issued medical ID bracelets. With a modular design and low price, tags provide an economical solution to a wide variety of patient management challenges. IT-725 Single-Use Patient Tag CenTrak, Inc. 125 Pheasant Run Newtown, PA 18940 t: 215-860-2928 e: [email protected] www.centrak.com IT-725 in use Β© CenTrak 2014. All Rights Reserved. Proprietary and Confidential. IT-725, IT-725P,IT725S Single-Use Patient Tag Technical Specifications Operation FCC Operating Frequency Range 902-928 MHz (Model #IT-725) CE Operating Frequency Range 868-870 MHz (Model #ITEU-725) Group code & tag ID codes 8M code5 Outdoor transmission range > 300 feet Average transmission power 2 uW (average) Gen2IR sensor YES Motion Sensor YES Tag Dimensions Case width 1.5 in (38.1 mm) Case height 1.98 in (50.3 mm) Case width 0.6 in (15 mm) Case weight (with battery) 0.77 oz (21.8 g) Construction Soft PVC Environmental/Cleaning Operating Temperature 0 C to +70 C Storage temperature -25 C to +80 C Sealing Splash & Water resistant Power Battery type Lithium CR2032 Smart tag feature Low battery indication This component complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Modifying or tampering with the transceiverβs or receiverβs internal components can cause a malfunction, invalidate the warranty, and will void FCC authorization to use these products. This product or its systems are covered by one or more of the following U.S. patents: 5,917,425, 7,061,428, 7,378,964, 7,619,532. L β utilisation de ce dispositif est autorisΓ©e seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) lβ utilisateur du dispositif doit Γ©tre prΓͺt Γ accepter tout brouillage radioΓ©lectrique reΓ§u, mΓͺme si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. CenTrak, Inc. 125 Pheasant Run Newtown, PA 18940 t: 215-860-2928 e: [email protected] www.centrak.com IT-725 Single-Use Patient Tag IT-725 in use IC Statement: Le prΓ©sent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisΓ©e aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioΓ©lectrique subi, mΓͺme si le brouillage est susceptible d'en compromettre le fonctionnement.
Date: June 27, 2012 FCC and IC Confidentiality Request In accordance with 0.459 & 0.457 of CFR 47, please, accept this letter as an official request to have the following kept as confidential for the reference IDs: IC: 6012A-IT725 Model numbers: IT-725, IT-275P, IT-725S And: FCC: ST2-IT725 The information provided is for the sole purpose of inclusion as exhibits in the Application for Certificate of the FCC & IC IDs stated above: We ask to keep confidential the following Tag (model# IT-725) documents: ο· Schematics ο· Block Diagram ο· Operational description Sincerely, Israel Amir, CTO CenTrak, Inc. 125 Pheasant Run Newtown, PA 18940 215.860.2928
Date: 5/27/2014 To whom it may concern: We, the undersigned, hereby authorize Wei Li, Advanced Compliance Labo ratory, Inc., to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Advanced Compliance Laboratory, Inc. on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are no t subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). I n authorizing Advanced Compliance Laboratory, Inc. as our agent, we still recognize that we are responsibl e to: β’ comply with the relevant provisions of the certification program; β’ make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; β’ make claims regarding certification only in respect of the scope for which certification has been granted; β’ do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; β’ upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; use certification only to indicate the products are certified as being in conformity with specified standards; β’ endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; β’ ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; β’ keep a record of all complaints made known to the us relating to the productβs compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; β’ take appropriate action with respect to such complaints and any deficiencies found in products or se rvices that affect compliance with the requirements for certification; 5 Caufield Place Ste 102, Newtown PA 189 40 i Tel 215.860.2928 i Fax 215.359.0659 i www.centrak.com β’ document the actions taken This authorization is valid until further written notice from the a pplicant. Sincerely Yours, Printed Name: Israel Amir Title: CTO Company: CenTrak, Inc. z Page 2
SINGLE USE PATIENT TAG Model No. IT-725 FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 23 7.1 Front View SINGLE USE PATIENT TAG Model No. IT-725 FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 24 7.2 Back View
SINGLE USE PATIENT TAG Model No. IT-725 FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 8 2. PRODUCT LABELING Figure 2.1 FCC ID Label Figure 2.2 Location of Label on the Side of EUT Centrak SINGLE USE PATIENT TAG Model No.: IT-725 FCC ID: ST2-IT725 IC: 6012A-IT725 This device complies with part 15 of the FCC Rules and IC RSS-210 & RSS-Gen Rules.. Operating is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Figure 2.2 Location of the Label ID Label Figuare 2.1 FCC/IC ID Label (Only ID show on the EUT)
SINGLE USE PATIENT TAG Model No. IT-725 FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 25 7.3 PCB Component Side View SINGLE USE PATIENT TAG Model No. IT-725 FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 26 7.4 PCB Foil Side View
ELECTROMAGNETIC EMISSION COMPLIANCE REPORT of SINGLE USE PATIENT TAG MODEL: IT-725/IT-725P/IT-725S FCC ID: ST2-IT725 IC:6012A-IT725 May 14, 2014 This report concerns (check one): Original grant x Class II change Equipment type: Low Power Intentional Radiator Test Specifications: ____FCC Part 15C Sec. 15.249 ____Industry Canada RSS-210 (Issue 8) & RSS-Gen (Issue 3) Deferred grant requested per 47 CF 0.457(d)(1)(ii)? yes no x If yes, defer until: (date) Company agrees to notify the Commission by (date) of the intended date of announcement of the product so that the grant can be issued on that date. Report prepared for: CENTRAK, INC. Report prepared by: Advanced Compliance Lab Report number: 0048-140502-02 Lab Code: 200101 The test result in this report IS supported and covered by the NVLAP accreditation 6 Randolph Way Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 Advanced Compliance Laboratory SINGLE USE PATIENT TAG Model No. IT-725/IT-725P/IT-725S FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 2 Table of Contents Report Cover Page .................................................................................................... 1 Table of Contents ...................................................................................................... 2 Figures ....................................................................................................................... 3 1. GENERAL INFORMATION .................................................................................. 4 1.1 Verification of Compliance ......................................................................... 4 1.2 Equipment Modifications ............................................................................ 5 1.3 Product Information ................................................................................... 6 1.4 Test Methodology ...................................................................................... 6 1.5 Test Facility ............................................................................................... 6 1.6 Test Equipment .......................................................................................... 6 1.7 Statement for the Document Use ................................................................ 7 2. PRODUCT LABELING .......................................................................................... 8 3. SYSTEM TEST CONFIGURATION ...................................................................... 9 3.1 Justification ................................................................................................ 9 3.2 Special Accessories .................................................................................... 9 3.3 Configuration of Tested System.................................................................. 9 4. SYSTEM SCHEMATICS ....................................................................................... 13 5. RADIATED EMISSION DATA ............................................................................. 14 5.1 Field Strength Calculation .......................................................................... 14 5.2 Test Methods and Conditions ..................................................................... 14 5.3 Test Data ................................................................................................... 14 6. EUT RECEIVING MODE VERIFICATION .......................................................... 20 7. PHOTOS OF TESTED EUT ................................................................................... 22 SINGLE USE PATIENT TAG Model No. IT-725/IT-725P/IT-725S FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 3 Figures Figure 2.1 FCC/IC ID Label ..................................................................................... 8 Figure 2.2 Location of Label ..................................................................................... 8 Figure 3.1 Radiated Test Setup ................................................................................. 10 Figure 4.1 EUT Schematics ....................................................................................... 12 Figure 7.1 Front View ............................................................................................... 21 Figure 7.2 Back View ................................................................................................ 22 Figure 7.3 PCB Component Side View ..................................................................... 24 Figure 7.4 PCB Foil Side View .................................................................................. 25 SINGLE USE PATIENT TAG Model No. IT-725/IT-725P/IT-725S FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 4 1. GENERAL INFORMATION 1.1 Verification of Compliance EUT: SINGLE USE PATIENT TAG Model: IT-725/IT-725P/IT-725S ( all models are electrical identical ) Applicant: CENTRAK, INC. Test Type: FCC Part 15.249 & IC RSS-210 (Issue 8) A2.9 & RSS-Gen (Issue 3) Result: PASS Tested by: ADVANCED COMPLIANCE LABORATORY Test Date: May 14, 2014 Report Number: 0048-140502-02 The above equipment was tested by Compliance Laboratory, Advanced Technologies, Inc. for compliance with the requirement set forth in the FCC rules and regulations Part 15 subpart C. This said equipment in the configuration described in the report, shows the maximum emission levels emanating from equipment are within the compliance requirements. The estimated uncertainty of the test result is given as following. The method of uncertainty calculation is provided in Advanced β¦
Text truncated - open the document above for the full version.
SINGLE USE PATIENT TAG Model No. IT-725 FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 11 SINGLE USE PATIENT TAG Model No. IT-725 FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 12 SINGLE USE PATIENT TAG Model No. IT-725 FCC ID: ST2-IT725 IC:6012A-IT725 βββββββββββββββββββββββββββββββββββββββββββββββ Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844 Tel: (908) 927-9288 Fax: (908) 927- 0728 13 Figure 3.1 Radiated Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 904 MHz - 926 MHz | - |
Safety 2.0 Bracelet
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
BLE MultiMode Badge
Equipment Class
DTS - Digital Transmission System
Man Down
Equipment Class
DTS - Digital Transmission System
Hand Hygiene Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Mini MM Patient/Asset Tag ITD/U-766E/H, -7622E/H,-7623E/H
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter