Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Aug 29, 2013
Application Purpose
Original Equipment
Date of Application
Aug 29, 2013
Equipment Note
Movement Detector
Frequency Range
315.00000000 - 315.00000000
Company
Smartacc Technology
Country
France

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

C C E E - - M M e e s s u u r r e e s s SAS au capital de 50 000 € / RC Grenoble B534 796 453 / SIRET 534 796 453 00015 / code APE 7490B / n° TVA : FR 59 534 796 453 SMEE ZI des Blanchisseries – Rue de Taille 38500 VOIRON TĂ©l. 04 76 65 76 50 - FAX. 04 76 66 18 30 Email: [email protected] – Web: www.smee.fr FCC Registration Number: 0020356952 (FRN) Test Firm Registration Number: 171131 August 30 th , 2013 CONFIDENTIALITY REQUEST To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046-1609 Curtis-Straus LLC TCB One Distribution Center Circle, #1 Littleton, MA 02702 Re: Confidentiality request for a Low Power Communication Device FCC ID: SVOSA1807 Gentlemen: Smartacc Technology requests, pursuant to 47CFR 0.459, post grant confidentiality for portions of the material contained in this application. The following document regarding this submission for FCC ID: SVOSA1807 shall be kept confidential: 1. Block Diagram description of the ACCBRIDGE315 receiver (file: Block Diagram-SVOSA1807.pdf) 2. Operational description of the ACCBRIDGE315 receiver (file: Oper_Descr-SVOSA1807.pdf) Specifically, these exhibits contain information relating to circuit function and complexity that could be of benefit to competitors. The material contains trade secrets and confidential information that Smartacc Technology does not customarily release to the public and which is otherwise not generally available to the public. Regards, Certified By Laurent CHAPUS (Agent for this device) SMEE – CE Mesures Rue de Taille ZI des Blanchisseries 38500 Voiron - France [email protected] Applicant for this device: SMARTACC TECHNOLOGY Rudi Lenzen 13 rue des Coquelicots 31830 Plaisance Du Touch - France [email protected] Phone: +33 (0) 6 52912923 Fax : +33 (0) 9 72302096 FRN : 0022615892

Cover Letter(s)

July 18 th , 2013 AGENT’S AUTHORIZATION LETTER To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046-1609 Curtis-Straus LLC TCB One Distribution Center Circle, #1 Littleton, MA 02702 Re: Agent’s authorization letter FCC ID: SVOSA1807 I, an officer of SmartAcc Technology, do hereby authorize, until further notice, Laurent CHAPUS of SMEE – CE Mesures, ZI des Blanchisseries, Rue de Taille 38500 VOIRON, France, to act on our behalf in dealings before the Federal Communications Commission with respect to all matters relating to equipment authorizations under 47 CFR. This authorization includes, but is not limited to, the signing of Form 731. I certify that no party (as defined in 47 CFR 1.2002) to this application, including myself, is subject to a denial of federal benefits, that include FCC benefits, pursuant to section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C., 853A. Regards, Certified By: __________________ Rudi LENZEN CEO [email protected] Phone: +33 (0) 6 52 91 29 23 Fax : +33 (0) 9 72 30 20 96 SMARTACC TECHNOLOGY 13 rue des Coquelicots 31830 Plaisance du Touch - France FRN : 0022615892

External Photos

FCC ID: SVOSA1807 Page 1/2 EXTERNAL PHOTOS OF TESTED EUT Upper view Rear view Dimension in cm FCC ID: SVOSA1807 Page 2/2 Side view (connector) Side view (Antenna)

ID Label/Location Info

FCC ID: SVOSA1807 Page 1/1 PRODUCT LABELING FCC ID number label: This is the copy of the label stuck on the product

Internal Photos

FCC ID: SVOSA1807 INTERNAL PHOTOS OF TESTED EUT PCB view, with integral antenna Rear PCB view

Test Report

C C E E - - M M e e s s u u r r e e s s SAS au capital de 50 000 € / RC Grenoble B534 796 453 / SIRET 534 796 453 00015 / code APE 7490B / n° TVA : FR 59 534 796 453 Rapport d’essais / Test Report N° : 20619-FCC-1 Page 1 / 8 SMEE ZI des Blanchisseries – Rue de Taille 38500 VOIRON TĂ©l. 04 76 65 76 50 - FAX. 04 76 66 18 30 Email: [email protected] – Web: www.smee.fr FCC Registration Number: 0020356952 (FRN) Test Firm Registration Number: 171131 MatĂ©riel testĂ© : Equipment under test: AccBridge315 Constructeur: Manufacturer: SmartAcc Technology 13, rue des Coquelicots 31830 Plaisance du Touch -France Rapport dĂ©livrĂ© Ă  : Issued to: SmartAcc Technology (M. Rudi Lenzen) 13, rue des Coquelicots 31830 Plaisance du Touch -France RĂ©fĂ©rence de la proposition : Proposal number: 052013-20619 Date de l’essai : Date of test: June 26 th and 30 th , 2013 August 30 th , 2013 Objectif des essais : Test purpose: Qualification CEM suivant norme CFR FCC Part 15, Subpart B. EMC qualification accordingly to standard CFR FCC Part 15, Subpart B. (Communications Receiver) Lieu du test: Test location: SMEE CE-Mesures 38 VOIRON - France Test rĂ©alisĂ© par : Test realized by: JĂ©rĂ©my BLANCHER / Laurent CHAPUS Conclusion : Conclusion: L’équipement satisfait aux prescriptions des normes citĂ©es en rĂ©fĂ©rence. The appliance complies with requirements of above mentioned standards. Ed. Date Modifications / Pages Written by: Visa Approved by: Visa 1 2 August 8 th , 2013 August 30 th , 2013 Initial Edition Added information JĂ©rĂ©my Blancher Laurent Chapus La copie de ce document n'est permise que sous sa forme intĂ©grale. Ce document est le rĂ©sultat d’essais effectuĂ©s sur un Ă©chantillon. Il ne prĂ©juge pas de la conformitĂ© de l’ensemble des produits fabriquĂ©s Ă  l’objet essayĂ©. This document shall not be reproduced, except in full. This document contains results related only to the item tested. It does not imply the conformity of the whole production to the item tested. Page 2 / 8 Rapport d’essai / Test Report N° : 20619-FCC-1 Sommaire / Contents 1. NORMATIVE REFERENCES ............................................................................................................ 3 2. TEST SYNTHESIS ............................................................................................................................ 3 3. EQUIPMENT UNDER TEST (EUT) ................................................................................................... 4 4. TEST CONDITIONS .......................................................................................................................... 4 5. MODIFICATIONS OF THE EQUIPMENT UNDER TEST .................................................................. 4 6. RADIATED EMISSION MEASUREMENT ......................................................................................... 5 Page 3 / 8 Rapport d’essai / Test Report N° : 20619-FCC-1 1. Normative references Standard : FCC CFR 47, PART 15, Subpart B ANSI C63-4 (2009). Requirements for unintentional radiators, class B digital device. (Communications receiver) 2. Test synthesis ESSAI D’EMISSION / EMISSION TEST LIMITES / LIMITS RESULTATS / RESULTS Emissions conduites sur les bornes d’alimentation / Conducted emissions at power supply ports 150kHz-30MHz Section 15.107 Freq Quasi- Peak(dBÎĽV) Average (dBÎĽV) N/A (1) 150-500kHz 66 \ 56 56 \ 46 0.5-5MHz 56 46 5-30MHz 60 50 Emissions rayonnĂ©es / Radiated emissions 30MHz-2GHz Section 15.109 Measure at 3m PASS Freq Limit (dBÎĽV) 30-88MHz 40.0 (QP) 88-216MHz 43.5 (QP) 216-960MHz 46.0 (QP) 960MHz-1GHz 54.0 (QP) Above 1GHz 54.0 (AV) 74.0 (Pk) (1): EUT not connected to AC main Page 4 / 8 Rapport d’essai / Test Report N° : 20619-FCC-1 3. Equipment Under Test (EUT) Nom / Identification AccBridge315 N°: N.C Alimentation / Power supply 3V from Smartphone Auxiliaires / Auxiliaries Battery pack with 3V voltage regulator, mounted on Smartphone’s connector. EntrĂ©es-Sorties / Input / Output Câbles pour essai / Cables for test BlindĂ© / Shielded PrĂ©vu pour >3m / Intended for >3m DC mains 0.25m, 2wires No No Version programme / Firmware version NC Mode de fonctionnement / Running mode The tested sample is able to receive a modulated carrier at 315MHz from a SENSAL315 Programme de test / Test program NC Accessoire spĂ©cial / Special accessory None FrĂ©quence max interne EST / Max internal EUT frequency 26MHz (clock) 315MHz (Receiver frequency) 4. Test conditions HumiditĂ© relative / Relative Humidity : 55% TempĂ©rature / Temperature : 22°C Tension d’alimentation / Power supply voltage: Equipment sous test / Equipment under test: 3Vdc from external battery 5. Modifications of the equipment under test None Page 5 / 8 Rapport d’essai / Test Report N° : 20619-FCC-1 6. Radiated Emission Measurement (30MHz-2GHz) ANSI C63.4 TEST: Limits for radiated disturbance 30MHz –2GHz Verdict Method: Measurements were made in 3-meter Open Area Test Site (OATS) that complies to CISPR 16 and ANSI C63.4 Preliminary (peak) measurements were performed at an antenna to EUT separation distance of 3 meter. The EUT was rotated 360° about its azimuth with the receive antenna located at various heights in horizontal and vertical polarities. Final measurements (quasi- peak, peak and average) were then performed by rotating the EUT 360° and adjusting the receive antenna height from 1 to 4 m. All frequencies were investigated in both horizontal and vertical antenna polarity, where applicable. A pre-scan frequency identification of the EUT has been performed in a GTEM cell. The measured radiated field of the EUT is correlated to a measurement distance of 3m. (3-axis algorithm) The pre-characterization graphs are obtained in PEAK detection. PASS Laboratory Parameters: Required prior to the test During the test Ambient Temperature 10 to 40 °C 25°C Relative Humidity 10 to 90 % 55% Fully configured sample scanned over the following frequency range Frequency range on each side of line Measurement Point 30MHz – 2GHz 3 m distance Limits – FCC Part 15.109 Frequency…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: SVOSA1807 Page 1/1 MEASUREMENT PHOTO 1.1 Radiated emissions

Contact Information

Applicant

Rudy LENZEN(CEO)
[email protected]+33 (0) 6 52912923Fax: +33 (0) 9 72302096

Test Firm

SMEE-CE MesuresLaurent CHAPUS
[email protected]33476657650Fax: 33 4 76 66 18 30

Technical Specifications

#Rule PartsFrequency RangePower Output
115B315 MHz - 315 MHz-