Userβs Manual for HDX5GHz-Tx1000 & HDX5GHz-Rx1000 Procedure to turn on HM1000 Transceiver system 1. Check and find a right pair of a transmitter(camera) and a receiver 2. Turn on a receiver first as follows 3. Turn on a transmitter(camera) as follows 4. Special Note (when HM1000 transceiver system used with Black Box) Picture on left is a HM1000 multimedia receiver 1) Install an antenna in a LOS position with respect to that of a transmitter. (LOS: line of sight) 2) Connect NTSC/PAL signal of a bottom right hole on the receiver side to A/V input of Display 3) Apply DC power (9V~24V) to a hole on the top right side of the receiver Picture on left is a HM1000 multimedia transmitter 1) Install an antenna in a LOS position with respect to that of a receiver. (LOS: line of sight) 2) Apply DC power (9V~24V) to a hole on the center [or bottom] connector of the transmitter(camera) After turning on a black box to be connected, go through step 1), 2), 3) above 1) Connect NTSC/PAL signal of a bottom right hole (receiver) to A/V input of a Blackbox 2) Connect Video output of a Blackbox to a Video display 5. Product Specification HDX5GHz- Tx1000 Frequency 5 160 γ ~ 5 240 γ, 5 735 γ ~ 5 815 γ Output Power +14dBm Antenna Gain 3.81 dBi (NII) / 3.238 dBi (DTS) Input Voltage DC 12V Size (mm) 92 x 62 x 42 mm Weight (g) 500g HDX5GHz- Rx1000 Frequency 5 160 γ ~ 5 240 γ, 5 735 γ ~ 5 815 γ Output Power +14dBm Antenna Gain 4.8dBi Input Voltage DC 12V Size (mm) 100 x 50 x 5.7 mm Weight (g) 100g CE European CE notice to users and product statements This product is CE marked according to the provisions of the R&TTE Directive(99/5/EC). Hereby, Harmonix declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. For further information, please contact http://www.hmnix.com Disclaimer Notice The manufacturer shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. This document contains proprietary information, which is protected by international patent applications and copyright. All rights reserved. No part of this document may be copied, reproduced or translated without prior written consent of the manufacturer. The manufacturer reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation to notify any person of such revisions or changes. The manufacturer also reserves the right to chan ge the specifications without notice. Product Warranty * Harmonix warrants this product against all defects in material and workmanship for a period of one year from the date of purchase by end user. The conditions for warranty are as follows: * The warranty is valid only if the original receipt issued to the original purchaser by the dealer is presented with the product to be repaired or replaced. * The warranty is void if the serial number, date of purchase and product label had been removed. * The warranty does not cover any failure or damage of the product due to normal wear and tear, physical abuse, improper installation, misuse, modification or repairs by unauthorized third parties. * Harmonix does not assume responsibility for any loss or damage incurred during shipment and as a result of force majeure. * Harmonix is not liable for any incidental or consequential damages arising from the use or misuse of the product. * All warranty claims are limited to repair or replacement of the defective product at the sole discretion of Harmonix. * If Harmonix repairs or replaces the product, the repaired or replaced product shall be warranted for the remaining time of the original warranty period. Repair or replacement may involve the use of functionally equivalent reconditioned units. Replaced part or product becomes the property of Harmonix.*
Harmonix Co., Ltd. RM T-7004, Techno, Garden 5 Life, 516 Munjeong-dong, Songpa-gu, Seoul, Korea, 138-960 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: SWCHDX5GHZ-RX1000 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commissionβs rules (47 CFR Β§Β§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematics Block Diagram Operation Description Parts List Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely Yours, YoungKeun Kim / Technical Sr. Manager Harmonix Co., Ltd.
External photos of EUT Front view of EUT Rear view of EUT Top view of EUT Bottom view of EUT RP-SMA type connector Side view of EUT Antenna RP-SMA type connector
Label location
Internal photos of EUT Removed Shield RF part Internal photo Top view of Main PCB Bottom view of Main PCB
- 1 - Object Dipole Antenna Page 1 of 7 Customer Date March 30, 2011 System WIFI 2.4/5 GHz Dual-band Ver. IR Model Name W1E β WO β 08 Written by G.. H. KIM Electrical Specifications Frequency Range ( MHz ) 2400 γ 2483.5 5150 γ 5875 Band Width ( MHz ) 83.5 725 V.S.W.R ( Min ) 1.9 : 1 1.9 : 1 Gain ( Max ) 2.5 Β± 1 ( dBi ) 3.5 Β± 1 ( dBi ) Input Impedance 50 ( Ξ© ) Polarization Linear Mechanical Specifications Antenna Size (Length x Diameter) 105 Γ 11 Connector SMA Reverse Polarity (Female) Weight N/A Operation Temperature β 30 γ 70 ( Β°C ) Operation Humidity 10 γ 90 ( % ) Option Remarks WINiZEN Co., Ltd. Specifications Sheet - 2 - Fig 1. Return Loss (Agilent E8358A 300KHzβΌ9GHz PNA Series Network Analyzer) Fig 2. V.S.W.R (Agilent E8358A 300KHzβΌ9GHz PNA Series Network Analyzer) - 3 - Fig 3. Smith Chart (Agilent E8358A 300KHzβΌ9GHz PNA Series Network Analyzer) - 4 - Fig 4. Measurement Configuration Fig 5. Axis Definitions (Antenna Center ) - 5 - Fig 6. Gain Patterns a. Azimuth Pattern ; Co β Pol b. Elevation Pattern ; Co β Pol - 6 - c. Elevation Side Pattern ; Co β Pol - 7 - Fig 7. Drawing
MOVON CORPORATION Report Number: MOV-13-RF-I032(1) Page : (1) of (33) The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test report cannot be reproduced, except in full, without the written approval of MOVON CORPORATION. FCC Part 15 Subpart C Β§15.247 Test Report Equipment Under Test Harmonix Wireless OWL Model Name HDX5GHz-Rx1000 Applicant Harmonix Co., Ltd. FCC ID SWCHDX5GHZ-RX1000 Manufacturer Harmonix Co., Ltd. Date of Test(s) 2013. 10. 08 ~2013. 10. 30 Date of Issue 2013. 11. 18 In the configuration tested, the EUT complied with the standards specified above. Issue to Issue by Harmonix Co., Ltd. RM T-7004, Techno, Garden 5 Life, 516 Munjeong-dong, Songpa-gu SEOUL 138-960 KOREA Tel.: +82-2-585-7360 Fax: +82-2-2157-7362 MOVON CORPORATION 194-1, Geumeo-ri, Pogok-eup, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea, 449-812 Tel.: +82-31-338-8837 Fax: +82-31-338-8847 MOVON CORPORATION Report Number: MOV-13-RF-I032(1) Page : (2) of (33) The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test report cannot be reproduced, except in full, without the written approval of MOVON CORPORATION. Revision history Revision Date of issue Description Revised by -- Oct 17, 2013 Initial -- 1 Nov 18, 2013 Revised Restricted Band & antenna requirement Raymond.kim MOVON CORPORATION Report Number: MOV-13-RF-I032(1) Page : (3) of (33) The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test report cannot be reproduced, except in full, without the written approval of MOVON CORPORATION. Table of contents 1. GENERAL INFORMATION ............................................................................................. 4 2. EUT DESCRIPTION ........................................................................................................ 5 3. MEASUREMENT EQUIPMENT ...................................................................................... 6 4. TRANSMITTER RADIATED SPURIOUS EMISSIONS AND CONDUCTED SPURIOUS EMISSIONS .................................................................................................................. 7 5. 6 γ BANDWIDTH ....................................................................................................... 20 6. MAXIMUM PEAK OUTPUT POWER MEASUREMENT ............................................... 23 7. POWER SPECTRAL DENSITY MEASUREMENT ....................................................... 26 8. ANTENNA REQUIREMENT ......................................................................................... 29 9. RF EXPOSURE EVALUATION .................................................................................... 30 10. TEST SETUP PHOTO OF EUT .................................................................................. 32 MOVON CORPORATION Report Number: MOV-13-RF-I032(1) Page : (5) of (33) The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test report cannot be reproduced, except in full, without the written approval of MOVON CORPORATION. 2. EUT Description Kind of product Harmonix Wireless OWL Model Name HDX5GHz-Rx1000 Serial Number N/A Power supply DC 12 V Frequency range 5 180 γ ~ 5 220 γ, 5 735 γ ~ 5 815 γ Modulation technique DSSS (11Mbps) Number of channels 3 / 5 Antenna gain 3.238γi (Max.) Test Site Registration Number FCC(670686) 2.1. Declarations by the manufacturer None 2.2. Details of modification None MOVON CORPORATION Report Number: MOV-13-RF-I032(1) Page : (6) of (33) The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test report cannot be reproduced, except in full, without the written approval of MOVON CORPORATION. 3. Measurement equipment Equipment Manufacturer Model Serial number Calibration Interval Calibration due. EMI Test Receiver R&S ESIB26 100196/026 1 year 2013-12-14 Signal Generator R&S SMR27 100089 1 year 2013-12-13 Spectrum Analyzer R&S FSV-40 100832 1 year 2014-10-04 Power Meter Agilent E4416A GB41290645 1 year 2014-10-04 Power Sensor Agilent 9327A US40441490 1 year 2014-10-04 Double Redge Horn Antenna R&S HF906 100236 2 year 2015-02-28 Ultra Broadband Antenna R&S HL562 100170 1 year 2013-12-13 Power Amplifier MITEQ AM-1431 1497315 1 year 2014-10-04 Power Amplifier MITEQ AFS43-010026001374382 1 year 2014-10-04 High Pass Filter Wainwright WHK3.0/18G-10SS508 1 year 2014-10-04 DC Power Supply HP 6674A 3637A01351 1 year 2014-10-04 Controller INNCO CO2000 co200/064/6961003/LN/A N/A Antenna Master INNCO MA4000 MA4000/038/6961003/LN/A N/A Loop Antenna ETS LINDGREN 6502 00118166 2 year 2015-09-27 β» Remark; Support equipment Description Manufacturer Model Serial number Notebook computer HP. HP Mini 110-3721TU 5CB1351VK9 MOVON CORPORATION Report Number: MOV-13-RF-I032(1) Page : (7) of (33) The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test report cannot be reproduced, except in full, without the written approval of MOVON CORPORATION. 4. Transmitter radiated spurious emissions and conducted spurious emissions 4.1. Test setup 4.1.1. Transmitter radiated spurious emissions The diagram below shows the test setup that is utilized to make the measurements for emission from 9kHz to 30MHz Emissions. The diagram below shows the test setup that is utilized to make the measurements for emission from 30 γ to 1 γ emissions. MOVON CORPORATION Report Number: MOV-13-RF-I032(1) Page : (8) of (33) The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test report cannot be reproduced, except in full, without the written approval of MOVON CORPORATION. The diagram below shows the test setup that is utilized to make the measurements for emission from 1 γ to 40 γ emissions. 4.2. Limit According to Β§15.247(d), in any 100 γ bandwidth outside the frequency band in which the spread spectrum or digitβ¦
Text truncated - open the document above for the full version.
Test setup photo of EUT A. Setup photo of EUT Photo of radiated spurious emission at below 30 γ Photo of radiated spurious emission at 30 γ ~ 1 000 γ Photo of radiated spurious emission at above 1 000 γ
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 5.74 GHz - 5.82 GHz | 20.00 mW |

HARMONIX WIRELESS OWL