READ BEFORE INSTALLATION SAVE THESE INSTRUCTIONS Model #S13CWPK/MM/BZ OUTDOOR COMMERCIAL WALL LIGHT WARNING: RISK OF SHOCK. House electric current can cause painful shock or serious injury unless handled properly. WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. WARNING: RISK OF CUTS. Some metal parts in the fixture may have sharp edges. To prevent cuts and scrapes, wear gloves when handling the parts. Limited Warranty CAUTION: Turn off the main power at the circuit breaker before installing the fixture, in order to prevent possible shock. Product Specifications: • 120/277 VAC, 50/60Hz, 125W max • Dimmable with 0-10V dimmer only • Suitable for wet locations NOTE: Hardware not shown to actual size. PartDescriptionQuantity AAWall Light1 BBFront Cover Screws2 CCWall Mounting Screws4 DDJ-Box Mounting Screws3 EEPlastic Anchors4 FFWire Connectors5 GGSensor Cover1 Level Level AA BB Center Knock Ou Level t Supply Line (Black) Supply Neutral (White) J-Box Grounding (Green) Neutral (White) Line (Black) LED DRIVER Twist-on wire connector Connector to LED Supply Line (Black) Supply Neutral (White) Neutral (White) Line (Black) LED DRIVER Twist-on wire connector Connector to LED J-Box Grounding (Green) NOTE: A Dust-To-Dawn Sensor Cover is provided to block out light and bypass the sensor. This will keep the light on continuously and the fixture can be controlled through the wall switch or a master photocell. NOTE: The 180-degree coverage of the motion sensor is measured side-to-side. The sensor will detect motion across the field of view (see below image). The motion sensor maximum detection range is up to 60 ft. NOTE: There will be a warmup time for about 10 seconds when first powered up. Brightness will be at 100% and will then drop to 30% after the warmup time. Brightness will go to 100% once motion is detected. 180º 8 FT Motion Sensor Motion Detection Area Motion Detection Area Mounting Height CCT - - 3K - - - 3.5K - 4K - 5K - 6.5K 4000 - - LUMEN ProblemPossible CauseSolution The light will not illuminate. The power is off. Make sure the power supply is on. There is a faulty wire connection. Check the wiring. Contact a qualified and licensed electrician if you are not comfortable troubleshooting wiring problems. There is a faulty wire switch.Test or replace the switch. The light does not automatically turn off during daylight hours. The photocell is covered. 1. Remove any debris and clean the photosensor. 2. Remove sensor cover Security light cycles ON and OFF continuously Dusk-to-Dawn sensor is sensing reflected light from the security light or other surrounding light source. 1. Ensure no reflective materials are near to the wall pack. 2. Relocate the LED Wall Pack to a different location where it no longer causes reflected light. Light will not dim to 30% Switch is positioned in the D2D mode. Position switch to the MOT mode
1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: Feit Electric company Inc. Contact Name: Aaron Feit FRN: 0024691990 Address: 4901 Gregg Road Pico Rivera,Ca 90660 Telephone No: (562) 463-2852 Email: [email protected] Applicant: Company name: Feit Electric company Inc. Product Description: Wall light Grantee code: SYW FCC ID: SYW-S13CWPKMM FRN: 0024691990 Contact Name: Aaron Feit Address: 4901 Gregg Road Pico Rivera,Ca 90660 Telephone No: (562) 463-2852 Email: [email protected] [Feit Electric company Inc.] certifies that, as of the date of this filing of the application with the TCB, [Feit Electric company Inc.] is our designated US agent for service of process for the above referenced FCC ID. [Feit Electric company Inc.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [Feit Electric company Inc.] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2024/6/20 Applicant’s Name: Aaron Feit US Agent’s Name: Aaron Feit Title: President Title: President Signature Signature
C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Feit Electric company Inc. Applicant’s FRN:0024691990 Product Description: Wall light Grantee code: SYW FCC ID: SYW-S13CWPKMM Contact Name: Aaron Feit Address: 4901 Gregg Road Pico Rivera,Ca 90660 Telephone No: (562) 463-2852 Fax No: (562) 908-6360 Email: [email protected] i. [Feit Electric company Inc. ] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Feit Electric company Inc. ] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Feit Electric company Inc. ] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: 2024/6/20 Applicant’s Name: Aaron Feit Title: President Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
Feit Electric company Inc. Product Similarity Declaration Product name: Wall light Model name: S13CWPK/MM/BZ, TWL213/12000DM/83065LEDC/P180MW/5WY-DTZ FCC ID: SYW-S13CWPKMM We (Feit Electric company Inc.) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only difference is the model name. Signature: Name: Aaron Feit Address: 4901 Gregg Road Pico Rivera,Ca 90660 Province
C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Feit Electric company Inc. Address: 4901 Gregg Road Pico Rivera,Ca 90660 Product Name: W all light Model Number: S13CWPK/MM/BZ, TWL213/12000DM/83065LEDC/P180MW/5WY-DTZ FCC Identifier: SYW-S13CWPKMM We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Aaron Feit 2024-6-20 Title: President Signature of applicant:
C5266091_X10_Ed.2 1/1 Feit Electric company Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024-6-20 Subject: Request for Confidentiality FCC ID: SYW-S13CWPKMM To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Aaron Feit Title: President
Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Product Name: Wall light Test Model No.: S13CWPK/MM/BZ EUT Constructional Details Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Shenzhen QC Testing Laboratory Co., Ltd. Page 3 of3 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn ------End------
25# 1.1A, 125W 146-24-WW This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CONFORMS TO UL STD. 1598 CERTIFIED TO CSA STD. C22.2 No. 250.0 5014385
Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of7 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Product Name: Wall light Test Model No.: S13CWPK/MM/BZ EUT Constructional Details Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of7 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Shenzhen QC Testing Laboratory Co., Ltd. Page 3 of7 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Shenzhen QC Testing Laboratory Co., Ltd. Page 4 of7 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Antenna Shenzhen QC Testing Laboratory Co., Ltd. Page 5 of7 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn - Shenzhen QC Testing Laboratory Co., Ltd. Page 6 of7 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Shenzhen QC Testing Laboratory Co., Ltd. Page 7 of7 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn -----End------
Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn FCC ID: SYW-S13CWPKMM RF Exposure Evaluation FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, and highest channel individually. Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Test Result of RF Exposure Evaluation Antenna gain=5.22dBi Test Frequency (MHz) Minimum Separation Distance (cm) Output Power (dBm) Target power (dBm) Target power (mW) Antenna Gain (Numeric) Power Density Limit (mW/cm 2 ) Power Density At 20 cm (mW/cm 2 ) Test Results 5761 20.00 -2.44 -2±1 0.79 3.33 1 0.0005 Pass Note: 1. use the maximum E-field strength(92.76dBuV/m) for the RF exposure evaluation 2. E(dBuV/m)=EIRP(dBm)-95.2 for distance 3m so the EIRP=92.76dBuV/m-95.2=-2.44dBm The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure.
Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT24DR-1441E-01 Page 1 of 20 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn FCC PART 15.249 TEST REPORT On Behalf of Feit Electric company Inc. 4901 Gregg Road Pico Rivera,Ca 90660 FCC ID: SYW-S13CWPKMM Model: S13CWPK/MM/BZ, TWL213/12000DM/83065LEDC/P180MW/5WY-DTZ April 11, 2024 T his Repo rt Co nc erns: Original Report Equip men t T ype: Wall light Test Engineer: LBi Li / Report Number: QCT24DR-1441E-01 Test Date: April 7~9, 2024 Reviewed By: Gordon Tan/ Approved By: Kendy Wang / Prepared By: Shenzhen QC Testing Laboratory Co., Ltd. East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT24DR-1441E-01 Page 2 of 20 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Table of Contents 1. GENERAL INFORMATION ................................................................................................. 4 1.1 Product Description for Equipment under Test (EUT) ............................................................4 1.2 System Test Configuration .....................................................................................................4 1.3 Test Facility ............................................................................................................................5 1.4 Measurement Uncertainty ......................................................................................................5 2. SUMMARY OF TEST RESULTS ........................................................................................ 6 3. LIST OF TEST AND MEASUREMENT INSTRUMENTS .................................................... 7 3.1 Conducted Emission Test ......................................................................................................7 3.2 Radiated Emission Test .........................................................................................................7 3.3 RF Conducted test .................................................................................................................8 4. ANTENNA REQUIREMENT ................................................................................................ 9 5. CONDUCTED EMISSIONS ............................................................................................... 10 5.1 Applicable Standard ............................................................................................................. 10 5.2 Limit ..................................................................................................................................... 10 5.3 Test setup ............................................................................................................................ 10 5.4 EMI Test Receiver Setup ..................................................................................................... 10 5.5 Test procedure ..................................................................................................................... 10 5.6 Test Data ............................................................................................................................. 10 6. RADIATED EMISSION METHOD ..................................................................................... 13 6.1 Applicable Standard ............................................................................................................. 13 6.2 Limit ..................................................................................................................................... 13 6.3 Receiver setup ..................................................................................................................... 13 6.4 Test setup ............................................................................................................................ 13 6.5 Test Procedure .................................................................................................................... 14 6.6 Test Data ............................................................................................................................. 15 7. 20DB OCCUPY BANDWIDTH .......................................................................................... 19 7.1 Applicable Standard ............................................................................................................. 19 7.2 Limit ..................................................................................................................................... 19 7.3 Test setup ............................................................................................................................ 19 7.4 Test Data ............................................................................................................................. 19 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT24DR-1441E-01 Page 3 of 20 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Revision History of This Test Report Report Number Description Issued Date QCT24DR-1441E-01 Initial Issue 2024-4-11 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT24DR-1441E-01 Page 4 of 20 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn 1. GENERAL INFORMATION 1.1 Product D…
Text truncated - open the document above for the full version.
Antenna Specification ITEM ANT SPEC Model Name 5.8G ANT Center Frequency 5.8GHz Operating Frequency 5.725 GHz-5.875GHz OCW N/A Operating Temperature Range 25T85 Number of channels N/A Antenna Assembly Type Microwave antenna Gain 5.22dBi Output power 0dBm Modulation Type N/A Adaptivity N/A Polarization Linear Polarization Azimuth Beam Pattern Directional Impedance 50 Ohm Antenna Size 12.4mm*12.4mm Manufacture Shenzhen Merrytek Technology Co.,Ltd add Rm 101-1101, 17th Building, Dianda Guyuan Industrial Park, Mashantou Community, Matian Street, Guangming District, Shenzhen, China, 518106 Trademark Radiation Pattern Power (dB) Max: 10 Min: -30 Scale: 5/div 3D Polar Plot
Shenzhen QC Testing Laboratory Co., Ltd. Page 1 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Product Name: Wall light Test Model No.: S13CWPK/MM/BZ Photograph of Test Setup Conducted Emissions Radiated Emissions (30 MHz - 1 GHz) Shenzhen QC Testing Laboratory Co., Ltd. Page 2 of 2 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Radiated Emissions (Above 1 GHz)
Pico Rivera, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 5.76 GHz - 5.76 GHz | - |

Remote controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Smart TV Backlight
Equipment Class
DTS - Digital Transmission System
Tape Light
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterLED WALL MOUNT PACK
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter