T98SUNWAYELECTRICAL BALLAST

HID HUT, Inc.

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Jun 19, 2006
Application Purpose
Original Equipment
Date of Application
Jun 19, 2006
Equipment Note
ELECTRICAL BALLAST
Frequency Range
0.03000000 - 0.04000000
Company
HID HUT, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

ID Label/Location Info

↗
↗

Internal Photos

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

600W High Pressure Sodium User’s Manual- HID HUT Features: 1. This 600 Watt HPS ballast is capable of operating a 600 Watt High Pressure Sodium Bulbs. 2. The Digital Circuitry replaces the inefficient magnetic ballasts, and can reduce power consumption (current) up to 30% 3. The Digital Circuitry is designed to operate under unstable power conditions with an operating range from -25% power to +15% power, and the output wattage does not change! This means more protection from power outages or fluctuations. 4. The output voltage is regulated and stable, and the luminescence of the bulb is steady without “flames”. This extends the life of your bulbs, and increases the performance. 5. The Digital Circuitry also has safety features. It can prevent accidents from open circuits- if there is an open circuit the ballast does not turn on. It goes into a standby mode for 10 minutes, at which point it checks for a closed circuit and tries again. 6. If the lamp does not fire- the ballast discontinues power, and attempts to fire the bulb only once every 10 minutes. Magnetic ballasts continue supplying full power to a bulb which is off- reducing the life of the bulb. Ballast Installation and Usage: 1. The ballast must be equipped with a 600W bulb- High Pressure Sodium only. 2. Ensure all connections between ballast and bulb are securely wired and insulated. 3. Plug ballast into any 120V wall outlet. It is a good idea to use a surge suppressor. 4. There are no on switches. When the ballast is plugged in it should be on. Precautions: 1. There is over 3KV voltage on the output wires, so the power must be off when installing ballast, repairing connections, plugging in bulbs or any maintenance. 2. If it is subjected to voltage outside it’s suggested operating range it can become damaged. 3. It’s normal operating temperatures are between -40 and +122 degrees Fahrenheit. If you exceed these temperatures in the vicinity of the ballast, the life of the ballast will be diminished. 4. Because of the character of gas lamps, they should only be restarted after having been given sufficient time to cool. The ballast automatically regulates this to ten minutes. 5. Ballast should not be exposed to water. 6. The ballast should not be used in the vicinity of any combustible or volatile materials. Warning: Disconnect line voltage before installing or replacing. Ballast case must be grounded. FCC Warning Statement The manufacturer is not responsible for any radio or TV interference caused by unauthorized modification to this equipment. Such modification could void the user’s authority to operate the equipment. This product many cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment between 0.150 – 30 MHz

Block Diagram

600W HPS EB

ID Label/Location Info

FCC ID Label FCC ID: T98SUNWAY

ID Label/Location Info

Proposed FCC ID Label Location:

Operational Description

Installing and Using Details of HID electronic ballast 1It should be equipped with the specified lamp, otherwise it will result in flick or damage the bulb. Please do not use MH bulbs to test HPS electronic ballast, or use HPS bulbs to test MH electronic ballast. 2There is exceeding 3KV voltage at output terminal of the electronic ballast, so the power must be shut off while installing, repairing and testing. 3It can work stably for lon g time in its specified voltage and be sure not to exceed this range. 4Its operate circumstance is –40 to +50.If you exceed the temperature the life-span of the product will be shorted. 5Because of the character of the metal halide lamp, you should restart the lamp after it is cooled down enough if it is shut off, you should wait for about 10 minutes. Ballast can control this process automatically.(When the lamps are shut off, the ballast will go into protection condition, and will not work even the user ne glects to restart the bulbs which have a high temperature, and the ballast will restart to work until the bulbs cool down enough. 6Please put the ends without wires of the electronic ballast upward when the ballast installed outdoor , this ballast has the waterproof design, but still cannot be used in water for a long time. 8Try to avoid the ballast being used in high temperature for a long time, and try to make it far away from the high temperature when installing.

Test Report

FCC PART 18 INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT TEST REPORT APPLICANT HID HUT INC. ADDRESS 27 SYCAMORE CIRCLE ORMOND BEACH, FL 32174 USA FCC ID T98SUNWAY MODEL NUMBER SUNWAY PRODUCT DESCRIPTION ELECTRONIC HID BALLAST DATE SAMPLE RECEIVED MAY 23, 2006 DATE TESTED JUNE 14, 2006 TESTED BY Nam Nguyen APPROVED BY Mario de Aranzeta TIMCO REPORT NO. 1053UT6 TOTAL PAGES 8 TEST RESULTS PASS FAIL THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC. 849 NW STATE ROAD 45 NEWBERRY, FL 32669 USA PH: 888.472.2424 OR 352.472.5500 FAX: 352.472.2030 EMAIL: [email protected] HTTP://WWW.TIMCOENGR.COM Certificate # 0955-01 Certificate # 0955-01 Applicant: HID HUT, INC. FCC ID: T98SUNWAY Report: V:\H\HIDHUT\1053UT6\1053UT6TestReport.doc Page 2 of 8 TABLE OF CONTENTS STATEMENT OF COMPLIANCE.................................................................................. 3 GENERAL INFORMATION .......................................................................................... 4 EMC EQUIPMENT LIST ............................................................................................. 5 TEST PROCEDURE ................................................................................................... 6 POWER LINE CONDUCTED INTERFERENCE............................................................. 7 Certificate # 0955-01 Applicant: HID HUT, INC. FCC ID: T98SUNWAY Report: V:\H\HIDHUT\1053UT6\1053UT6TestReport.doc Page 3 of 8 STATEMENT OF COMPLIANCE This equipment has been tested in accordance with the standards identified in the referenced test report. To the best of my knowledge and belief, these tests were performed using the measurement procedures described in this report and demonstrate that the equipment complies with the appropriate standards. No modifications were made to the equipment during testing in order to demonstrate compliance with these standards. I attest that the necessary measurements were made by me or under my supervision, at Timco Engineering, Inc. located at 849 N.W. State Road 45, Newberry, Florida 32669 USA. Authorized by: Mario de Aranzeta Signature: Function: Engineer Date: June 15, 2006 Tested by: Nam Nguyen Signature: on file Date: June 14, 2006 Certificate # 0955-01 Applicant: HID HUT, INC. FCC ID: T98SUNWAY Report: V:\H\HIDHUT\1053UT6\1053UT6TestReport.doc Page 4 of 8 GENERAL INFORMATION DUT Specification The test results relate only to the items tested. DUT Description Electrical Ballast FCC ID T98SUNWAY Model Number EBX-YYY X stands for number from 1 to 9. YYY stands for number from 001 to 999 All models are electrically identical except the cosmetic design and power level for marketing purpose. The model with highest power level was tested to represent worst case scenario. Serial Number N/A Operating Frequency Modulation N/A Emission N/A No. of Channels N/A 110–120Vac/50– 60Hz DC Power DUT Power Source Battery Operated Exclusively Test Item Prototype Pre-Production Production Type of Equipment Fixed Mobile Portable Antenna N/A Antenna Connector N/A Test Facility: The test sites used by Timco Engineering Inc. for radiated and conducted emission data is located at 849 NW State Road 45 Newberry, FL 32669 USA. Test Condition: The DUT was tested in the laboratory in an environment with normal temperature and humidity. The temperature was 26ºC with a relative humidity of 50%. Modification to the DUT: No modification was made to the DUT during testing. Test Exercise (e.g software description, test signal, etc.): The DUT was placed in continuous transmit mode of operation. Applicable Standards: ANSI Standard C63.4: 2003 FCC CFR 47 Part 18 FCC/OET MP5 Certificate # 0955-01 Applicant: HID HUT, INC. FCC ID: T98SUNWAY Report: V:\H\HIDHUT\1053UT6\1053UT6TestReport.doc Page 5 of 8 EMC EQUIPMENT LIST Device Manufacturer Model Serial Number Cal/Char Date Due Date 3/10-Meter OATS TEI N/A N/A Listed 3/27/04 3/26/07 3-Meter OATS TEI N/A N/A Listed 1/11/06 1/10/09 Biconnical Antenna Eaton 94455-1 1057 CAL 12/12/05 12/12/07 Biconnical Antenna Eaton 94455-1 1096 CAL 8/17/04 8/17/06 Biconnical Antenna Electro-Metrics BIA-25 1171 CAL 4/29/05 4/29/07 Blue Tower Quasi-Peak Adapter HP 85650A 2811A01279 CAL 4/13/05 4/13/07 Blue Tower RF Preselector HP 85685A 2926A00983 CAL 9/5/05 9/5/07 Blue Tower Spectrum Analyzer HP 8568B 2928A04729 2848A18049 CAL 4/13/05 4/13/07 LISN Electro-Metrics ANS-25/2 2604 CAL 8/27/04 8/27/06 LISN Electro-Metrics EM-7820 2682 CAL 4/28/05 4/28/07 Log-Periodic Antenna Eaton 96005 1243 CAL 12/14/05 12/14/07 Certificate # 0955-01 Applicant: HID HUT, INC. FCC ID: T98SUNWAY Report: V:\H\HIDHUT\1053UT6\1053UT6TestReport.doc Page 6 of 8 TEST PROCEDURE Radiation Interference: The test procedure used was ANSI STANDARD C63.4- 2003 using a HEWLETT PACKARD spectrum analyzer with a pre-selector. The bandwidth of the spectrum analyzer was 100 kHz with an appropriate sweep speed. The analyzer was calibrated in dB above a microvolt at the output of the antenna. The resolution bandwidth was 100KHz and the video bandwidth was 300kHz. The ambient temperature of the UUT was 86oF with a humidity of 56%. Formula Of Conversion Factors: The field strength at 3m was established by adding the meter reading of the spectrum analyzer (which is set to read in units of dBuV) to the antenna correction factor supplied by the antenna manufacturer. The antenna correction factors are stated in terms of dB/m. The gain of the Pre-selector was accounted for in the Spectrum Analyzer Meter Reading. Example: Freq (MHz) Meter Reading + ACF +coax loss = FS 33 20 dBuV + 10.36 dB+3.10 = 46.66 dBuV/m @ 3m Power Line Conducted Interference: The procedure used was ANSI Standard C63.4- 2003 using a 50uH LISN. Both lines were observed. The bandwidth of the spectrum analyzer was 10kHz with an appropriate sweep speed. ANSI Standard C63.4-2003 10.1.7 Measurement Procedures: The unit under test was placed on a table 80 cm high and with dimensions of 1m by…

Text truncated - open the document above for the full version.

Test Setup Photos

Power Line Conducted Emission Setup Photo Radiated Emission Setup Photo

Contact Information

Applicant

Justin Robinson(Manager)
[email protected]352-258-5829Fax: 352-258-5829

Test Firm

Timco Engineering, Inc.Bruno Clavier
[email protected]352-472-5500Fax: 352 472 2030

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.03 MHz - 0.04 MHz-