FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Dynam Industrial & Trading Co., Ltd/
  3. TIVDYNAM-CN002

TIVDYNAM-CN002R/C Transmitter

Shenzhen Dynam Industrial & Trading Co., Ltd
R/C Transmitter - FCC ID TIVDYNAM-CN002 - Shenzhen Dynam Industrial & Trading Co., Ltd
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Feb 20, 2008
Application Purpose
Original Equipment
Date of Application
Feb 20, 2008
Equipment Note
R/C Transmitter
Frequency Range
72.01000000 - 72.99000000
Company
Shenzhen Dynam Industrial & Trading Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗
↗

Schematics

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

RACON 3 FM Digital proportional system Thank you for purchasing Dynam RACON 3-channel digital radio system.It is a high quality radio and can be used in electric park-flying airplane. It is important that you read the manual should carefully before operate your model. Before useing please read the instructions completely 1 ON-OFF SWITCH CH1 CH2 CH3 ON-OFF ELEVON MIXING LED-low(yellow) LED-power(red) Throttle Stick Elevator or Rudder Stick Elevator trim Rudder trim RACON Transmitter RACON Instructions Light : 10V-12V when it light safely Flash light : 9.5V-9V please Notice do not fly long time under 9V please stop use and change the battery Yellow Yellow LED RACON Instructions RACON Instructions Back Cover (welded) When the elevator stick is pulled back, the tail elevator is raised and the tail of the plane is forced down. The air flow applied to the wings is changed. the lifting force is increased, and the plane climbs(up operation) when the elevator stick is pushed forward, the elevator is lowered the tail of the please is forced up. the air flow applied to the wings is changed. The lifting force is do creased and the plane dives (down operation). 2 When the rudder stick is moved to the right, the rudder moves to the right, and the move points to the right, relative to the direction of flight. When the rudder stick is moved to the left, the rudder moves the left and the direction of travel of the plane changes. RACON Instructions RACON Instructions When the throttle stick is pulled back, the engine throttle lever arm moves to the solw side, when the throttle stick is pushed for wrad, the throttle lever arm moves to the high side + - RACON Instructions 3 B RACON Instructions 4 Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment

Block Diagram

11 22 33 44 D D C C B B A A Title Number Revision Size A4 Date: 2007-11-27 Sheet of File: C:\Documents and Settings\..\3ch 方框图 11.Sch Drawn By: Bat Charger 5v Voltage Regulator Signal Creator Power On Indicator Batter Low Indicator I/O Signal Control Power Supply Input Modulation RF Oscillator RF PA 3CH Function Frame

ID Label/Location Info

FCC ID: TIV DYNAM-CN002 This device complies with part 95 of the FCC rules. Proposed Label Location on EUT FCC ID Label Location

Operational Description

RaCON-3 Description 1. Specifications z Frequency coverage 72.010~72.990(MHz); z Type of emission Frequency Modulation; z Radio Frequency Power 20DBm; z Current drain DC12V 300mA; z Signal Pulse width 0.5~2.0ms; 2. Circuit Operation Description The RaCON-3 3-channel radio system circuit is shown as Figure-1. Figure-1 This circuit is consisted of the following parts: z Battery and Power supplier; z I/O controller; z Proportional-Control pulse signal Creator; z FM signal Modulator; z Radio frequency(RF) power amplifier; z Antenna. The microprocessor-based controller receives the operator’s instructions, and generates proportional-control pulse signal. The signal is modulated in FM mode by the voltage-control quartz oscillator, and then transmitted to three grade transformer-coupled amplifier circuits and sent to the aerospace.

Parts List/Tune Up Info

3CH-72MHzBOM SMD: 11C10805 21C5 0805 31 C2 0805 41 C40805 51C3 0805 6 1C70805 81 C10 0805 9 1C120805 101 C130805 11 1C140805 121C240805 13 1C180805 14 1C190805 151C200805 16 2C22/23 0805 171 C26 0805 181 C28 0805 193 C32/33/34 0805 203 R0/1/20805 211R3 1206 22 1R4 0805 231R110805 241 R5 0805 25 2R6/R90805 . 261R70805 271 R120805 28 1 R80805 29 1 R100805 30 1R140805 314 R13 /15/16/23 0805 32 1R170805 33 1R180805 34 1R190805 351R200805 361R21 0805 371R220805 381R240805 391R250805 401R260805 421U1 SOT89 43 1 Q1 SOT89 44 1 Q2 SOT23 45 1 Q3SOT23 46 2 Q4/Q5SOT23 47 1 D1 0805 481D30805 491 502C0 C61 1210 11L1 21L2 31T1 43T2/T3/T4 51L3 61XTAL 71RV 81CV 5P NC TX-72/35 72M C3124 1SV231(1SV302) C1815 22UF/16V AMOUNT 470R 6.8R 1000P 510P 220P 0.01U 47P 8.2P 12P 12P 1.5P 200P 24P 33P DIP: 10P C8/9/11/15/16/17/21/25/27/29/30/31 0R ITEM 12 NOTEPACKAGE 0805 7 72M SPECIFICATION 15P 1N4148 12K 4.7K NC C4269(2735) 12K 33R 30K 330R 820R 2.2K 4.8*7.5T*0.4 7KB*R38K*0.4 7KB*R45K*0.4 10R 2SC4536(C3357) 78L06 0R 10K 560R 7K-72 3.3uH 72MHz 30P 102 3ch-Emitter Board 0.1U 4.7R 3.3K 220R 2.4R 2.4R 47P LOCATION 68P

Parts List/Tune Up Info

ITEMNAMESPECIFICATIONLOCATIONPACKAGE 1 MCUEM78P458U2sop20 2LDO78L05U3sot89 3diodeSS14D5 4diode1N4148D40805 5transistorC1815Q6sot23 6res10k R30 R31 R35 R41 R47 R52 R54 R55 0603 7res5.1kR39 R45 R51 R530603 8res100R R57 R59 R62 R63 R64 R65 0603 9res1kR33 R360603 10res1.2kR32 R37 R660603 11res2.2kR34 R42 0603 12res20kR43 R480603 13res0R R27 R38 R40 R49 R58 R61 0603 14cap103 C35 C38 C40-41 C44- C57 0603 15cap30pfC42 C430603 16cap22uf/16VC371210 17mag. Bead82RL41206 18pcb board3ch-ver-2.0 19crystal osc.4MHzDIP 20potentiometerB5K100deg 21potentiometerB5K100deg 3ch-Signal Board BOM 1 8 4 6 1 1 1 1 2 3 2 2 AMOUNT 1 2 1 1 1 6 19 2 1

Schematics

high frequency emit.sch-1 - Tue Nov 27 08:08:02 2007

Schematics

3CH encode.sch-1 - Tue Nov 27 08:14:31 2007

Test Report

ISO/IEC17025 Accredited Lab. Report No: FCC 0711197 File reference No: 2007-12-19 Applicant: Shenzhen Dynam Industrial&Trading Co.,Ltd Product: RACON Model No: DYCN002 Trademark: DYNAM Test Standards: FCC 47 CFR PART 95 SUBPART C Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 95 Subpart C, regulations for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: Dec 19,2007 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD 5/F,Block 4, Anhua Industrial Zone.,No.8 TaiRan Rd.CheGongMiao,FuTian District, Shenzhen,CHINA. Tel (755) 83448688 Fax (755) 83442996 Report No: 0711197 Page 2 of 23 Date: 2007-12-19 TEST REPORT The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 899988. IC- Registration No.: IC5205A-01 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration IC No.: 5205A-01. Report No: 0711197 Page 3 of 23 Date: 2007-12-19 TEST REPORT The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ............................................................................................... 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT ........................................................................................... 4 1.4 Submitted Sample.............................................................................................. 4 1.5 Test Duration.................................................................................................... 4 1.6 Test Uncertainty................................................................................................ 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 5 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Test Result.......................................................................................................................... 8 5.1 E.U.T. Operation.............................................................................................. 8 5.2 Test Procedure & Measurement Data...................................................................... 8 5.2.1 Flied Strength of Fundamental.............................................................................. 8 5.2.2 Flied Strength of Harmonics or other Frequency...................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Bin Li(High-grade Engineer)
[email protected]86-769-3039575Fax: 86-769-3039577

Test Firm

Shenzhen Timeway Testing LaboratoriesJack Chung
[email protected]0755-83448688Fax: 86-755-83442996

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
195C72.01 MHz - 72.99 MHz2.50 mW5K50F1D0.0020000000 %
Grant Notes
Power output listed is ERP.