FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Maiwei Broadcast Equipment Co., Ltd./
  3. TN326733836

TN326733836Digital Satellite Receiver

Shenzhen Maiwei Broadcast Equipment Co., Ltd.
Digital Satellite Receiver - FCC ID TN326733836 - Shenzhen Maiwei Broadcast Equipment Co., Ltd.
Click to zoom

Application Details

Equipment Class
HID - Part 15 TV Interface Device
Date of Grant
Dec 05, 2005
Application Purpose
Original Equipment
Date of Application
Dec 05, 2005
Equipment Note
Digital Satellite Receiver
Frequency Range
67.25000000 - 71.75000000
Company
Shenzhen Maiwei Broadcast Equipment Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Block Diagram

CPU CX24142 LNB 11.111MHz POWER SUPPLY AC 90~265V,50/60Hz SMPS SDRAM FLASH RS-232 SERIAL PORT Video & Audio RF MODULATOR S-VIDEO OUTPUT SCART OUTPUT RCA OUTPUT BLOCK DIAGRAM

ID Label/Location Info

FCC ID: TN326733836 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Proposed Label Location on EUT FCC ID Label Location

Test Report

LABORATORIES Report No: FCC 0509076 File reference No: 2005-11-30 Applicant: Shenzhen Maiwei Broadcast Equipment Co., Ltd Product: Digital Satellite Receiver Model No: FS 4000 Trademark: Mvidea Test Standards: FCC Part 15 Subpart B: 2004 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 regulations for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: Nov 30, 2005 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD East 5/Block 4, Anhua Industrial Zone, No.8,Tairan Rd. CheGongMiao, FuTian District, Shenzhen, CHINA. Tel (755) 83448688 Fax (755) 83442996 Report No: 0509076 Page 2 of 25 Date: 2005-10-10 TEST REPORT The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 3 1.1 Test Lab Details................................................................................................ 3 1.2 Applicant Details.............................................................................................. 3 1.3 Description of EUT ............................................................................................3 1.4 Test Uncertainty................................................................................................ 3 1.5 Submitted Sample............................................................................................. 3 1.6 Test Duration.................................................................................................. 3 2.0 List of Measurement Equipment........................................................................ 4 2.1 Conducted Emission Test..................................................................................... 4 2.5 Radiated electromagnetic disturbance test................................................................. 4 3.0 Technical Details............................................................................................. 5 3.1 Investigations Requested..................................................................................... 5 3.2 Test Standards.................................................................................................. 5 4.0 Power line Conducted Emission Test..................................................................... 6 5.0 Radiated Disturbance Test................................................................................... 9 6.0 Antnna Power Conducted Measurement............................................................... 12 7.0 Output Signal Level Measurement. ..................................................................... 13 8.0 Output Terminal Conducted Spurious Emission Measurement................................... 15 9.0 Transfer Switch Measurement............................................................................ 16 10.0 FCC Label........................................................................................................ 18 11.0 Photo of testing........................................................................................................................... 19 Report No: 0509076 Page 3 of 25 Date: 2005-10-10 TEST REPORT The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 1.0 General Details 1.1 Test Lab Details Name : SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD Address: East 5/Block 4, Anhua Industrial Zone, No.8,Tairan Rd. CheGongMiao, FuTian District, Shenzhen, CHINA. Telephone: (755) 83448688 Fax: (755) 83442996 1.2 Applicant Details Applicant: Shenzhen Maiwei Broadcast Equipment Co., Ltd Address: 13/F, Fiyta Hi-tech Building, Gaoxinnanyi Avenue, Southern District of Hi-tech Park, Nanshan District, Shenzhen, China Telephone: 86-755-26733836/86018900 Fax: 86-755-26520637/26634876 1.3 Description of EUT Product: Digital Satellite Receiver Manufacturer: Shenzhen Maiwei Broadcast Equipment Co., Ltd Address: 1-3/F, Bldg. #11, Second Industrial Park, Guanlong, Xili, Shenzhen, China Brand Name: Mv


Text truncated - open the document above for the full version.

Contact Information

Applicant

Xing Cao(Supervisor)
[email protected]+86-755-26018345Fax: +86-755-26518342

Test Firm

Shenzhen Timeway Testing LaboratoriesJack Chung
[email protected]0755-83448688Fax: 86-755-83442996

Technical Specifications

#Rule PartsFrequency RangePower Output
215B67.25 MHz - 71.75 MHz-