Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Invengo Information Technology Co., Ltd. Software User’s Manual 800&500 Series Reader Demo (.NET) Version:V1.83 Preface This demo is applicable to the Invengo product models including, but not limited to: XC-RF861 Reader This manual provides the information on the software installation, operation and other features. This manual’s version number is V1.83, printed on 2013-01-16 and logos are owned by Invengo Information Technology Co., Ltd. Content 1 Overview........................................................................................1 1.1 About Demo Software ......................................................................1 1.2 System Requirements ......................................................................1 1.3 Technical Terms ................................................................................1 2 Installing demo software .............................................................2 3 XCRF-800 Series Reader Demo User Manual ............................9 3.1 Running the read demo ...................................................................9 3.2 Connecting/disconnecting XCRF-800 Series reader ..................10 3.3 Read and write operation ..............................................................14 3.4 Configuration menu .......................................................................21 3.5 Function Menu ................................................................................30 4 Troubleshooting .........................................................................36 Appendix ........................................................................................38 Safety Instructions Your safety is extremely important. Read and follow all warnings and cautions in this document before handling and operating Invengo equipment. You can be seriously injured, and equipment and data can be damaged if you do not follow the cautions. Warning A warning alerts you of an operating procedure, practice, condition, or statement that must be strictly observed to avoid death or serious injury to the persons operating on the equipment. Notice A Note either provides: extra information about a topic or alerts to an operating procedure, practice, condition, or statement or corruption or loss of data, or contains special instructions for handling a particular condition or set of circumstances. Software User’s Manual 800 & 500 Series Reader Demo (.NET) 1 1 Overview 1 Overview 1.1 About Demo Software The Demo software is used to set system parameters and perform write/read operation on Invengo XCRF-800 series and XCRF-500 series reader and ISO compliant transponders 1.2 System Requirements ●Supported Operating Systems Windows 2000 Service Pack 3; Windows Server 2003; Windows XP Service Pack 2; Windows Vista; Windows 7 These systems are 32-bit operating system. The USB driver does not support 64- bit OS for the time being.. ●Required Software Windows Installer 3.0 is required. Windows Installer 3.1 or later is recommended. IE 5.01 or later is required: for installing the .NET Framework. ●Recommended hardware requirements CPU: Pentium 4 at 1.7 GHz or above Memory: min. 512MB 1.3 Technical Terms TID: Tag identifier EPC: Electronic product code RSSI: Received signal strength indicator LBT: Listen before Talk DRM: Dense reader mode Q: Slot count parameters EAS: Electronic Article Surveillance QT: innovative privacy features of Impinj Monza 4 tag chip Software User’s Manual 800 & 500 Series Reader Demo (.NET) 2 2 Installing demo software 2 Installing demo software Click’setup.exe’ Choose English and click OK button. Installation window will pop up if .NET Framework 2.0 is not installed. Click ‘Yes’. Software User’s Manual 800 & 500 Series Reader Demo (.NET) 3 2 Installing demo software Click ‘Next’. Please refer to the following picture: Accept and click ‘Install’ to continue setup. Software User’s Manual 800 & 500 Series Reader Demo (.NET) 4 2 Installing demo software Program will display the following screen directly if .NET Framework 2.0 has been installed. Click ‘Finish’. Software User’s Manual 800 & 500 Series Reader Demo (.NET) 5 2 Installing demo software Click ‘Next’. Please enter your information and click ‘Next’. Software User’s Manual 800 & 500 Series Reader Demo (.NET) 6 2 Installing demo software Select installation directory, click ‘Next’ Click ‘Install’ Software User’s Manual 800 & 500 Series Reader Demo (.NET) 7 2 Installing demo software Click ‘Finish’ to close installation. After successful installation, the desktop shortcut " "will appear Software User’s Manual 800 & 500 Series Reader Demo (.NET) 8 3 XCRF-800 Series Reader Demo User Manual The appropriate Start menu shortcuts will appear, as shown: Software User’s Manual 800 & 500 Series Reader Demo (.NET) 9 3 XCRF-800 Series Reader Demo User Manual 3 XCRF-800 Series Reader Demo User Manual 3.1 Running the read demo Click [Start]—[Programs], select Invengo Demo v1.83 program group, and click ‘XCRF-800(500) Demo v1.7’ to run the XCRF-800(500) Series reader Demo. Or double click ‘XCRF-800(500) Demo v1.83’ on the desktop run the XCRF- 800(500) Series reader Demo. Click ‘Start 800 Series Reader Demo’: The screen appears: Software User’s Manual 800 & 500 Series Reader Demo (.NET) 10 3 XCRF-800 Series Reader Demo User Manual 3.2 Connecting/disconnecting XCRF-800 Series reader 1. Selecting communication mode Three communication modes, including TCP/IP, COM (RS232) and USB, are available. Click ‘Comm. Port’ to select the desired communication mode. Notice: USB option will be available when USB device and the driver are installed: Install the USB driver as follows: Connect the reader with a USB cable, and apply power to the reader, the screen of ‘new hardware found’ appears. Click ‘Next’ Software User’s Manual 800 & 500 Series Reader Demo (.NET) 11 3 XCRF-800 Series Reader Demo User Manual Click ‘Next’ Click ‘Next’ Software User’s Manual 800 & 500 Series Reader Demo (.NET) 12 3 XCRF-800 …
Text truncated - open the document above for the full version.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (current) 2.0 3.0 Jan-31-2012 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 3.0 Invengo Information Technology co., Ltd. 2014-5-4 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, Invengo Information Technology Co., Ltd. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): FCC ID: TQ4XC-RF861 (Reader, XC-RF861) We affirm that between SIEMIC and Invengo Information Technology co., Ltd., any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Signature Shuangliang Yi/Quality manager E-mail: : [email protected] Phone: +86-0755-26525035 Fax: +86-0755-26525035 Address : 3/F,No.T2-B,High-tech industrial Park South, Shenzhen 518057,china
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 Invengo Information Technology co., Ltd. 2014-5-4 To: Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Permanent Confidentiality Request for FCC ID: TQ4XC-RF861 We hereby request confidential treatment of information accompanying this application as outlined below: - Block diagram - Operation description - Schematic The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Signature Shuangliang yi/Quality manager E-mail: : [email protected] Phone: +86-0755-26525035 Fax: +86-0755-26525035 Address : 3/F,No.T2-B,High-tech industrial Park South, Shenzhen 518057,china
Invengo Information Technology co., Ltd. Date: 2014-05-04 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD FCC ID: TQ4XC-RF861 To Whom It May Concern: This letter is to ascertain that Invengo Information Technology co., Ltd., Reader XC-RF861 has been the units used for conducting FCC compliance testing, the DoC part will be tested by FCC recognized test lab. If you have any question or concerns, pls. contact us. Sincerely, Signature Shuangliang yi/Quality manager E-mail: : [email protected] Phone: +86-0755-26525035 Fax: +86-0755-26525035 Address : 3/F,No.T2-B, High-tech industrial Park South, Shenzhen 518057, China
Label Location Proposed Label Location on EUT
RFID Module Antenna
FCC ID : TQ4XC-RF861 RF EXPOSURE EVALUATION According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure(MPE) Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density(mW/cm 2 ) Average Time (A) Limits for Occupational/Control Exposures 300-1500 -- -- F/300 6 1500-100000 -- -- 5 6 (B) Limits for General Population/Uncontrol Exposures 300-1500 -- -- F/1500 6 1500-100000 -- -- 1 30 11.1 Friis transmission formula: Pd=(Pout*G)\(4*pi*R 2 ) Where Pd= Power density in mW/cm 2 Pout=output power to antenna in mW G= Numeric gain of the antenna relative to isotropic antenna Pi=3.1416 R= distance between observation point and center of the radiator in cm Pd the limit of MPE, 1mW/cm 2 . If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. 11.2 Measurement Result Power density limited: Pd= f(MHz)/1500=900/1500=0.6mW/ cm 2 Antenna gain: 7.15 dBi Channel Channel Frequency (MHz) Output Peak power (dBm) Output Peak power (mW) Antenna Gain (dBi) Numeric Power density at 20cm (mW/ cm 2 ) Power density Limits (mW/cm 2 ) 1 902.75 27.27 533.33 5.19 0.550 0.6 25 915.25 27.34 542.00 5.19 0.559 0.6 50 927.25 27.13 516.42 5.19 0.533 0.6
TRF No.: FCC 15.247/A Page 1 of 43 Report No.: ES140324216E Shenzhen EMTEK Co.,Ltd. Building 69, Majialong Industry Zone, Nanshan District, Shenzhen,Guangdong,China www.emtek.com.cn Tel: +86-755-2695 4280 Fax: +86-755-2695 4282 Access to the World ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPARTC REQUIREMENT OF Reader MODEL No.: XC-RF861 FCC ID: TQ4XC-RF861 Trademark: Invengo REPORT NO: ES140324216E ISSUE DATE: April 30, 2014 Prepared for INVENGO INFORMATION TECHNOLOGY CO., LTD. 3/F, No.T2-B, High-tech industrial Park South, Shenzhen 518057, china Prepared by SHENZHEN EMTEK CO., LTD Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China TEL: 86-755-26954280 FAX: 86-755-26954282 TRF No:FCC 15.247/A Page 2 of 43 Report No: ES140324216E Shenzhen EMTEK Co.,Ltd. Building 69, Majialong Industry Zone, Nanshan District, Shenzhen,Guangdong,China www.emtek.com.cn Tel: +86-755-2695 4280 Fax: +86-755-2695 4282 Access to the World VERIFICATION OF COMPLIANCE Applicant: INVENGO INFORMATION TECHNOLOGY CO., LTD. 3/F, No.T2-B, High-tech industrial Park South, Shenzhen 518057, china Manufacturer: INVENGO INFORMATION TECHNOLOGY CO., LTD. 3/F, No.T2-B, High-tech industrial Park South, Shenzhen 518057, china Product Description: Reader Model Number: XC-RF861 Serial Number: N/A File Number: ES140324216E We hereby certify that: The above equipment was tested by SHENZHEN EMTEK CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 (2009) and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC Rules Part 15.247. The test results of this report relate only to the tested sample identified in this report. Date of Test : February 27, 2014 to April 20, 2014 Prepared by : Joe Xia/Editor Reviewer : June Xie/Supervisor Approve & Authorized Signer : Lisa Wang/Manager TRF No:FCC 15.247/A Page 3 of 43 Report No: ES140324216E Shenzhen EMTEK Co.,Ltd. Building 69, Majialong Industry Zone, Nanshan District, Shenzhen,Guangdong,China www.emtek.com.cn Tel: +86-755-2695 4280 Fax: +86-755-2695 4282 Access to the World Ta b l e o f C o n t e n t s 1. GENERAL INFORMATION ................................................................................................. 5 1.1 PRODUCT DESCRIPTION........................................................................................................................... 5 1.2 RELATED SUBMITTAL(S) / GRANT (S) ..................................................................................................... 5 1.3 TEST METHODOLOGY.............................................................................................................................. 5 1.4 SPECIAL ACCESSORIES............................................................................................................................ 5 1.5 EQUIPMENT MODIFICATIONS.................................................................................................................. 5 1.6 TEST FACILITY........................................................................................................................................ 6 2. SYSTEM TEST CONFIGURATION .................................................................................... 7 2.1 EUT CONFIGURATION............................................................................................................................. 7 2.2 EUT EXERCISE........................................................................................................................................ 7 2.3 TEST PROCEDURE.................................................................................................................................... 7 2.4 LIMITATION............................................................................................................................................. 7 2.5 CONFIGURATION OF TESTED SYSTEM................................................................................................... 10 2.6 EQUIPMENT USED IN TESTED SYSTEM.................................................................................................. 11 2.7 DESCRIPTION OF TEST MODES............................................................................................................... 12 3. SUMMARY OF TEST RESULTS ....................................................................................... 13 4. CONDUCTED EMISSIONS TEST ..................................................................................... 14 4.1 MEASUREMENT PROCEDURE:................................................................................................................ 14 4.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ....................................................................... 14 4.3 MEASUREMENT EQUIPMENT USED: ...................................................................................................... 14 4.4 CONDUCTED EMISSION LIMIT.................................................................................................................... 14 4.5 MEASUREMENT RESULT:....................................................................................................................... 15 5. RADIATED EMISSION TEST ............................................................................................ 17 5.1 MEASUREMENT PROCEDURE................................................................................................................. 17 5.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ....................................................................... 18 5.3 MEASUREMENT EQUIPMENT USED: ...................................................................................................... 19 5.4 MEASUREMENT RESULT......................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.75 MHz - 927.25 MHz | 542.00 mW |

Reader
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Reader
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterReader
Equipment Class
DTS - Digital Transmission System
Portable reader
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
reader-writer
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter