Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Table of Content ColumbaTD – Utilization Guide 1. Device components 2. Subscription and activation of the ColumbaTD ser vice 3. Installation of the ColumbaTD system 3.1. Choice and installation of the bracelet 3.2. Installation of the charger and load of the Ba ttery- block 3.2.1. Installation and positioning of the charger 3.2.2. Load of the Battery-block 3.3. Load of the ColumbaTD 4. Operating modes 4.1. RF mode 4.2. Regular mode 4.3. Leaving secured zone mode 4.4. Emergency mode 5. Utilization of the ColumbaTD 5.1. Geo-localization 5.1.1. Leaving secured zone 5.1.2. Localize the ColumbaTD 5.2. In case of Emergency – alert button 5.3. Hands free telephony 5.3.1. Functioning 5.3.2. Contact the ColumbaTD wearer 5.4. Automated alerts 5.4.1. Low battery 5.4.2. Leaving protected zone 6. Conditions and usage environment 6.1. General instruction 6.2. Wet environment 6.3. Particular conditions 6.3.1. Pacemaker 6.3.2. Acoustic apparatuses 6.3.3. Medical apparatuses 6.3.4. Security onboard a plane 6.3.5. Magnetism 7. Internet website www.medicalmobile.com 8. After-sales service 9. Recycling of the ColumbaTD and its components 10. Specifications 10.1. Specifications 10.2. Network services 10.3. Positioning services 10.4. GPS positioning service 10.5. Autonomy 10.5.1. RF mode autonomy 10.5.2. Regular mode autonomy 10.5.3. Leaving protected zone mode autonomy 10.6. Data related to the specific absorption rate 11. Legal advice 11.1. Intellectual ownership 11.1.1. Patents and Copyrights 11.1.2. Trademark 11.2. FCC Statement 11.3. Conformity declaration – CE marking 11.4. Limited warranty 11.5. About this utilization guide Utilization Guide In order to assure the optimal functioning of the C olumbaTD system, entire reading of this guide must be completed prior usage. The reading of this guide must be completed with th e reading of the General Condition and Subscription Formulary of the ColumbaTD service, include in the box containing th e ColumbaTD system, which also contains important d ocuments and legal advices that must be understood and accepted before activating the ColumbaTD. 1. System Components A. Electrical plug allowing recharge with the Batte ry-block B. Speaker/ Microphone. C. Luminous signs: a. Blue: its regular flashes indicates that the Col umbaTD is functioning b. Red: Its flashes indicate low level of the batte ry and that a recharge is necessary. The red light constantly remains lit when the alert button is act ivated or if the ColumbaTD tries to establish a dis tant contact with informatics server. D. Alert Button. E. Notch allowing to maintain the Battery-block in place on the ColumbaTD during recharge F. Bracelets. G. Lock: the unbolting key must be inserted in the appropriate hole to unbolt the lock. 1. System Components Charger A. Electrical plug allowing reloading the Battery-b lock. B. Battery-block base. B. Notch allowing to maintain the Battery-block in place on charger’s base. D. Luminous signs: a. Red: Indicates that the battery block is chargin g. The light goes off when the charge is completed. b. Blue: Indicates that the charger is functional. E. Plug for the electrical supply wire. F. Base for the unbolting key. G. Radio antenna (RF). Battery-block A. Lock: Drive in the mechanism to maintain the ba ttery-block on the charger or on the ColumbaTD. B. Holes to insert the unbolting key to liberate th e battery-block of the charger’s notch or of the Co lumbaTD. C. Luminous signs: a. Yellow: Indicates the ColumbaTD is charging. The light goes off when the charge is completed. Unbolting Key A. Unbolting key with two rods. 2. Subscription and activation of the ColumbaTD ser vice The ColumbaTD must be activated in order to be oper ational. This activation requires a subscription to the medical tele-security service offered in France by Medical Mobile. The subscription general conditions and the tele-se curity medical service subscription formulary are i nside this box. Those documents must be fully read, understood, and compl eted before being returned to the address indicated on the documents. On the days following the reception of the formular y, a representative will contact the subscriber to complete the activation of the ColumbaTD system. BEFORE THE REPRESENTATIVE CALLS, THE COLUMBATD SYSTEM MUST HAVE BEING PUT IN PLACE AND CHARGE ACCORDING TO THE INSTRUCTION IN THE FOLL OWING SECTION. During the call of a Medical Mobile representative, if the tests executed by the representative are co ncluding, the representative will confirm the activation of the ColumbaTD service. It is only at the moment of this confirmation by a Me dical Mobile representative, that the ColumbaTD is operational and the ColumbaTD service is activated. 3. Installation of the ColumbaTD system 3.1. Choice and installation of the bracelet The ColumbaTD system contains two bracelets of diff erent size, allowing better adaption to different w rist circumferences. Moreover, each bracelet has many possible adjustments, to pro cure superior comfort and maximum security to the w earer. To select the best suited bracelet, wrap each aroun d the wearer’s wrist. Choose the bracelet which rod (extremity of the bracelet that goes in the lock) is near the holes on the other ex tremity of the bracelet. Once the appropriate bracelet is chosen, it must be inserted in the slits under the ColumbaTD. It is p referable to place the ColumbaTD in the middle of the bracelet. This step completed, then the lock must installed i n the perforated extremity of the bracelet, using t he screwdriver include in the package. The lock must be screwed near the holes pr eviously identified. 3. Installation of the ColumbaTD System Then, install the bracelet with the ColumbaTD aroun d the wrist of the wearer, and identify the bracele t openings in which the lock must be screwed. The openings must be chosen in ord er to prevent the wearer from taking the bracelet o ff without unbolting the lock. Be sure the wearer is comfortable enough and tha…
Text truncated - open the document above for the full version.
MOD: CLM-CHG-001 06-16-01-03-xxxxxxxx Fabriqué au/made in Canada IC: 6387A-CLMCHG01 FCC ID: TV9-MICLM-B001
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful inteference, and (2) This device must accept any interference received, including interference that may cause undesired operation
FCC Part 15 Subpart C, §15.249: June 2006 Test Report: 5W57079.2 Applicant: Medical Intelligence 1170, Chemin Saint-Louis, Sillery (Québec) G1S 1E5, CANADA Apparatus: Columba Charger and Base Station FCC ID: TV9-MICLM-B001 In Accordance With: FCC Part 15 Subpart C, §15.249 Operation within the bands 902–928 MHz, 2400 – 2483.5 MHz, 5725 – 5875 MHZ, and 24.0 – 24.25 GHz Tested By: Nemko Canada Inc. 303 River Road Ottawa, Ontario K1V 1H2 Authorized By: Xu Jin, Wireless Specialist Date: August 1, 2006 Total Number of Pages: 26 Nemko Canada Inc. REPORT SUMMARY Report Number: 5W57079.2 FCC ID: TV9-MICLM-B001 Specification: FCC Part 15 Subpart C, 15.249 Page 2 of 26 Report Summary These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15, Subpart C. Radiated tests were conducted in accordance with ANSI C63.4-2003. Radiated emissions are made on an open area test site. A description of the test facility is on file with the FCC. The assessment summary is as follows: Apparatus Assessed: Columba Charger and Base Station Specification: FCC Part 15 Subpart C, §15.249 Compliance Status: Complies Exclusions: None Non-compliances: None Report Release History: Original Release Author: Roman Kuleba, EMC/Wireless Specialist Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. Nemko Canada Inc. REPORT SUMMARY Report Number: 5W57079.2 FCC ID: TV9-MICLM-B001 Specification: FCC Part 15 Subpart C, 15.249 Page 3 of 26 TABLE OF CONTENTS Report Summary......................................................................................................................................... 2 Section 1: Equipment Under Test.............................................................................................................. 4 1.1 Product Identification .................................................................................................................................4 1.2 Samples Submitted for Assessment............................................................................................................4 1.3 Theory of Operation ...................................................................................................................................4 1.4 Technical Specifications of the EUT ..........................................................................................................5 1.5 Block Diagram of the EUT.........................................................................................................................5 Section 2: Test Conditions.......................................................................................................................... 6 2.1 Specifications .............................................................................................................................................6 2.2 Deviations From Laboratory Test Procedures ............................................................................................6 2.3 Test Environment .......................................................................................................................................6 2.4 Test Equipment...........................................................................................................................................6 Section 3: Observations .............................................................................................................................. 7 3.1 Modifications Performed During Assessment ............................................................................................7 3.2 Record Of Technical Judgements ...............................................................................................................7 3.3 EUT Parameters Affecting Compliance .....................................................................................................7 3.4 Test Deleted................................................................................................................................................7 3.5 Additional Observations .............................................................................................................................7 Section 4: Results Summary ...................................................................................................................... 8 4.1 FCC Part 15 Subpart C: Test Results .........................................................................................................9 Appendix A: Test Results ......................................................................................................................... 10 Clause 15.207(a) Power Line Conducted Emissions ...........................................................................................10 Clause 15.209(a) Radiated Emissions within Restricted Bands ..........................................................................13 Clause 15.215(c) 20dB Bandwidth ......................................................................................................................18 Clause 15.249(a) Radiated emissions not in Restricted Bands ............................................................................19 Clause 15.249(d) Spurious emissions (except Harmonics)...............…
Text truncated - open the document above for the full version.
1170 Grande-Alle Quest · Quebec · Canada
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.40 GHz | - |

Wrist Worn Personal Location Device
Equipment Class
PCT - PCS Licensed Transmitter worn on body