Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
NOTIFEX ~ Transmitter Control Unit FCC Required Notices, Other Notices, Safety Instructions The NOTIFEX TCU does its job using radio waves. Thus it is subject to government rules that regulate who uses what radio frequencies and when and how they are used. The Federal Com-munications Commission (FCC) provides this regulation The FCC requires the following notices: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product: Notifex Beeper Transmitter - TCU FCC Grantee Code: UAT Equipment Product Code: N4TCU6 Responsible Party: Notifex; Putney Landing Enterprises Inc.; 61 Putney Landing, Putney, Vermont 05346 Phone: 802 387-4278 FCC Notices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be deter-mined by turning the equipment off and on, the user is encouraged to try to correct the interfere-ence by one or more of the following measures: Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Consult an experienced radio -TV technician for help. If you cannot eliminate the interference, the FCC requires that you stop using the unit. Do not change or modify the unit in any way. Applications, changes, or modifications not expres-sly approved by the manufacturer may cause interference, changes in operation which bring the unit out of compliance with FCC rules, and void the user's authority to operate the equipment. It in not permitted to connect this equipment to any kind of amplifying device. Pursuant to Part 95.1309 of the FCC Rules, use of this MURS unit within the United States does not require an FCC license to be obtained by the user. You are permitted to operate this unit if you cooperate in the selection and use of channels in order to reduce interference to others, and if you are not a representative of a foreign government. NOTIFEX ~ Transmitter Control Unit Important Safety Instructions Read these Instructions! They are for your benefit and protection. Save them for future reference. All safety and operating instructions should be read and understood before the TCU is operated. Pay attention to – and follow - any warnings you read in this document or see on the NOTIFEX TCU case. Use and follow these instructions. Doing so will help you get the most out of your NOTIFEX system, and will protect the safety of both people using the TCU and the device itself. Cleaning Disconnecting the TCU from wall power before you clean it is a good safety precaution. It should clean easily with a damp cloth; if necessary use a touch of soap or dish detergent. Do not use stronger household cleaners, aerosol or spray cleaners or waxes. Placement The NOTIFEX TCU should be placed where it will be out of the way and will not get knocked around. Avoid locating it where it might fall or be crashed into (by, for example, a vacuum or a chair). It should be located close enough to a 120V household wall outlet that it can be easily plugged in. All wires connected to the TCU should have a little slack in them to prevent “cord strain” at the points(s) of connection. Avoid running wires where they will be damaged by foot traffic or vacuum cleaners and the like, or where furniture or other objects may pinch or damage them. Do not locate the TCU near heat sources like heaters, radiators, heat registers, or fireplaces; on heat-producing devices like computers, amplifiers, TVs, toaster ovens, or the like; or on or near a stove. The NOTIFEX TCU can be mounted on a wall or can sit flat. Attachments Use only manufacturer supplied or authorized attachments, and use them only in the manner specified by NOTIFEX. Attachment of the wrong device to this unit could be hazardous to people and/or could harm the unit. Never put any foreign objects – or anything not supplied and/or approved by NOTIFEX into any of the openings on the unit. Water and Damp Water is an enemy to most electrical and electronic devices, and this TCU is no exception. This unit is not designed to get wet or be exposed to the elements. Keep it away from water including: swimming and kiddy pools, sinks or wash tubs, showers or bath tubs, washing machine, outdoor sprinklers, wet basements, or any other location where it may get wet. Never put anything wet into any of the openings on the unit. When to Seek Service Get the TCU serviced: if the unit has been harmed or damaged (physically or electrically); if any wires are frayed or damaged; if the unit has gotten wet; if the “power cube” (which plugs into a regular wall socket) gets unusually warm or hot (it is usually a little warm when it is plugged in); if there is a noticeable change in performance or if the unit doesn’t function properly. In the event of a malfunction in the unit, try the troubleshooting steps in these instructions first. Servicing There are no user-serviceable parts inside the case of the NOTIFEX TCU. Opening or removing the cover may expose you to electrical hazards, and will void the warrantee. If you decide to get the unit serviced (for example, after the warrantee period runs out), refer any servicing to qualified service personnel only,…
Text truncated - open the document above for the full version.
PUTNEY LANDING ENTERPRISES 61 Putney Landing Road Putney Vermont 05346 August 2 nd 2006 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: UATN4TCU6 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Schematic diagrams Detailed block diagrams All operational descriptions Parts list Tune up procedures. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Thomas Ehrenberg (signed) Thomas Ehrenberg President
TEST REPORT THE ELECTROMAGNETIC EMISSIONS ACCORDING TO FCC PARTS 2, 15, 95 (all 2005) OF THE NOTIFLEX TRANSMISSION CONTROL UNIT (TCU) PREPARED FOR S. BROWN PULLIAM, CONSULTANT 26 CONCORD ROAD BEDFORD MA 01730 PREPARED BY GLOBAL CERTIFICATION LABORATORIES, LTD. 4 MATTHEWS DRIVE EAST HADDAM CT 06423 DATE RELEASED July 31, 2006 FILE REF: BRN0601 Global Certification Laboratories, Ltd. 4 Matthews Drive East Haddam CT 06423 860 873-1451 voice 860 873-1947 fax S. BROWN PULLIAM, CONSULTANT NOTIFLEX TCU July 31, 2006 BRN0601 FCC Page ii of iii SIGNATURE PAGE THIS REPORT WAS PREPARED BY: ________________________________ JAMES COSTELLO TESTING WAS PERFORMED BY: ________________________________ STEPHEN M. PETIX THIS REPORT WAS REVIEWED BY: ________________________________ STEPHEN M. PETIX Global Certification Laboratories, Ltd. 4 Matthews Drive East Haddam CT 06423 860 873-1451 voice 860 873-1947 fax S. BROWN PULLIAM, CONSULTANT NOTIFLEX TCU July 31, 2006 BRN0601 FCC Page iii of iii TABLE OF CONTENTS Title Page......................................................................................................................................i Signature Page .............................................................................................................................ii Table of Contents ...................................................................................................................... iii Introduction .................................................................................................................................1 Product Identification ..................................................................................................................2 Technical Description..................................................................................................................3 Test Instrumentation....................................................................................................................4 Test Procedures, Part 15 Conducted Emissions Measurement....................................................5 Block Diagram, Part 15 Conducted Emissions Measurement.....................................................6 Test Data Explanation (Conducted) ............................................................................................7 Conducted Emissions Test Data .................................................................................................8 Test Procedures, Part 15 Radiated Emissions Measurement.....................................................10 Block Diagram, Part 15 Radiated Emissions Measurement ......................................................11 Test Data Explanation (Radiated) .............................................................................................12 Radiated Emissions Test Data ..................................................................................................13 Power Output Measurement ......................................................................................................16 Modulation Bandwidth Measurement .......................................................................................17 Spurious Emissions Measurement.............................................................................................18 Frequency Stability Measurement .............................................................................................20 Test Summary............................................................................................................................22 Global Certification Laboratories, Ltd. 4 Matthews Drive East Haddam CT 06423 860 873-1451 voice 860 873-1947 fax S. BROWN PULLIAM, CONSULTANT NOTIFLEX TCU July 31, 2006 BRN0601 FCC Page 1 of 22 INTRODUCTION This report describes the results of electromagnetic emissions testing of the: NOTIFLEX TRANSMISSION CONTROL UNIT, the E quipment Under Test. The EUT was subjected to the following tests: FCC Part 15 CONDUCTED EMISSIONS, FCC Part 15 RADIATED EMISSIONS, FCC Part 95 POWER OUTPUT, FCC Part 95 MODULATION BANDWIDTH, FCC Part 95 SPURIOUS EMISSIONS, FCC Part 95 FREQUENCY STABILITY. The results reported in this document relate only to the unit tested. All testing was performed at the facilities of Global Certification Laboratories, Ltd. East Haddam CT. All test equipment calibration is N.I.S.T. traceable. Global’s FCC registration number is 90615. This report contains detailed descriptions of the test procedures, test data, and a written summary of the results. The report may not be reproduced, except in its entirety, without the permission of Global Certification Laboratories. This report contains 22 numbered pages, plus Title, Signature, and Table of Contents Pages. Global Certification Laboratories, Ltd. 4 Matthews Drive East Haddam CT 06423 860 873-1451 voice 860 873-1947 fax S. BROWN PULLIAM, CONSULTANT NOTIFLEX TCU July 31, 2006 BRN0601 FCC Page 2 of 22 PRODUCT IDENTIFICATION EQUIPMENT UNDER TEST (EUT): MURS Radio MODEL: NOTIFLEX TCU SERIAL: NONE EUT SUPPORT EQUIPMENT: NONE Global Certification Laboratories, Ltd. 4 Matthews Drive East Haddam CT 06423 860 873-1451 voice 860 873-1947 fax S. BROWN PULLIAM, CONSULTANT NOTIFLEX TCU July 31, 2006 BRN0601 FCC Page 3 of 22 TECHNICAL DESCRIPTION NOTIFLEX TCU The Notiflex Transmitter Control Unit provides the central control for a paging system that would normally consist of a single small portable VHF Paging Receiver, this Transmitter Control Unit (TCU) and external sensors wired directly to the TCU. These sensors would be either dry switch or 5 Volt CMOS logic. The TCU has two wired sensor inputs, one for a Normally Open (NO) switch that would respond as an Active LOW logic input, and the other Normally Closed (NC) that has Active HIGH logic input. There is also a slide switch in parallel with the NC input to maintain closure if a sensor is not connected. The sensor input jacks are the small (sub RM45) modul…
Text truncated - open the document above for the full version.
TEST REPORT PHOTOS THE ELECTROMAGNETIC EMISSIONS ACCORDING TO FCC PARTS 2, 15, 95 (all 2005) OF THE NOTIFLEX TRANSMISSION CONTROL UNIT (TCU) PREPARED FOR S. BROWN PULLIAM, CONSULTANT 26 CONCORD ROAD BEDFORD MA 01730 PREPARED BY GLOBAL CERTIFICATION LABORATORIES, LTD. 4 MATTHEWS DRIVE EAST HADDAM CT 06423 DATE RELEASED July 31, 2006 FILE REF: BRN0601 Global Certification Laboratories, Ltd. 4 Matthews Drive East Haddam CT 06423 860 873-1451 voice 860 873-1947 fax S. BROWN PULLIAM, CONSULTANT NOTIFLEX TCU July 31, 2006 BRN0601 FCC Page 1 of 4 50 Ohm EUT (EXCEPT WHERE EUT SIZE PROHIBITS, TESTING IS DONE IN A SHIELDED ROOM) LINE IMPEDANCE STABILIZATION NETWORK GLOBAL CERTIFICATION LABORATORIES, LTD RECEIVER CONDUCTED EMISSIONS MEASUREMENTS AMN 120 VAC / 60 Hz 120 VAC / 60 Hz Global Certification Laboratories, Ltd. 4 Matthews Drive East Haddam CT 06423 860 873-1451 voice 860 873-1947 fax S. BROWN PULLIAM, CONSULTANT NOTIFLEX TCU July 31, 2006 BRN0601 FCC Page 2 of 4 GLOBAL CERTIFICATION LABORATORIES, LTD. RADIATED EMISSIONS TEST SET-UP POWER OUTLETS TURNTABLE TO SPECTRUM ANALYZER AND RFI RECEIVER LOG PERIODIC OR BICON ANTENNA TURNTABLE AND ANTENNA ARE LOCATED IN A POST-AND-BEAM WOODEN "BARN" IN ADJACENT TEST LAB EUT 3 METERS Global Certification Laboratories, Ltd. 4 Matthews Drive East Haddam CT 06423 860 873-1451 voice 860 873-1947 fax S. BROWN PULLIAM, CONSULTANT NOTIFLEX TCU July 31, 2006 BRN0601 FCC Page 3 of 4 POWER OUTPUT MODULATION BANDWIDTH Global Certification Laboratories, Ltd. 4 Matthews Drive East Haddam CT 06423 860 873-1451 voice 860 873-1947 fax S. BROWN PULLIAM, CONSULTANT NOTIFLEX TCU July 31, 2006 BRN0601 FCC Page 4 of 4 FREQUENCY STABILITY, TEMPERATURE VARIATION Heat chamber Freezer FREQUENCY STABILITY, INPUT VOLTAGE VARIATION
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 95J | 154.57 MHz - 154.57 MHz | 1.8 W | 11K0F2D | 5.0000000000 ppm |