Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
NCHH User Guide Novacore Hand Held Transmitter 2 NCHH UHF Digital Handheld Transmitter 1 Microphone Capsule 2 Upper Housing 3 LCD Screen 4 Power Switch 5 Mute Button 6 Multifunction Locking Slider 7 SET Button 8 MODE Button 9 Battery Holder 10 Battery Charging Contacts 11 USB Type-C Charging Port 12 Charging Indicator 13 Sync Window 14 Rear Cap 15 Lower Housing Features 3 NCHH UHF Digital Handheld Transmitter Battery Insertion • Rotate and detach the lower housing. • Ensure the power switch is off. Insert one battery with the negative (-) pole facing upward into the right slot, then insert another battery with the positive (+) pole facing upward into the left slot, following the polarity marks. 1. Do not use AA-sized 14500 lithium batteries (voltage exceeding 1.8V) or mix disposable batteries with 14500 lithium batteries. 2. Using incorrect batteries may cause malfunction or damage, which is not covered under warranty. Caution Installing AA Batteries 4 NCHH UHF Digital Handheld Transmitter • Rotate and detach the lower housing. • Ensure the power switch is off. Insert the lithium battery with the positive (+) pole facing upward into the left slot, following the polarity marks. 1. Use only an 18500 lithium-ion battery and confirm the polarity is correct before charging. 2. Turn off the transmitter before charging. 3. Do not remove the battery during charging. Disconnect the cable or dock first if removal is necessary. 4. If the charging indicator does not light up, check the battery installation. 5. If the transmitter fails to power on, recheck the polarity or charge level of the battery. Caution 18500 Rechargeable Lithium Battery Installation 5 NCHH UHF Digital Handheld Transmitter 1. Connect the USB Type-C cable to the charging port. 2. Observe the charging indicator: 1. Connect the charging dock (e.g., NCC1 or NCC2) to a power source and confirm that the power indicator lights up. 2. Place the transmitter into the charging dock and check the status: • Using USB Type-C Cable Charging • Using Charging Dock (Optional) • Orange light: Charging in progress. • Green light: Fully charged. • Red light: Charging in progress. • Green light: Fully charged. USB Type C Charing Port Battery Charging Contacts NCC2NCC1 Charging Methods 6 NCHH UHF Digital Handheld Transmitter Operating Instructions • Push the power switch upward to turn on the transmitter. The LCD screen will light up. • Push the power switch downward to turn off the transmitter. • Note: The LCD screen will display “OFF...” and automatically dim when turned off. • Press the SET button. The parameter on the LCD screen will blink, indicating that the parameter is ready to be adjusted. • Press SET again to confirm and apply the desired change. Press the MODE button to toggle through available functions displayed on the LCD screen. Power On/Off Lock Parameter Setting Mode Selection NCHH Lock Display • Enable the lock function to prevent accidental operation. All functions except MUTE will be locked. • To lock: Push the locking slider to the right. • To unlock: Push the locking slider to the left. 7 NCHH UHF Digital Handheld Transmitter NCHH LCD Display Settings • The battery level indicator displays the remaining battery level in six stages: 100%, 80%, 60%, 40%, 20%, and 10%. • When the battery level drops to 10%, recharge immediately. If the level is too low, the LCD screen will display “OFF” and the transmitter will automatically power off. • Group (GRP), Channel (CH), and Frequency (FREQ) Battery Level Display LCD Display Functions LCD Display Overview 17 Function Area 18 Parameter Area 19 Battery Level Indicator 20 Audio Input Level 1. Group, channel, and frequency settings are for display only and cannot be changed directly. 2. To change group, channel, or frequency settings, scan for available frequencies on the receiver. Then use the SYNC function to synchronize the settings with the transmitter. 8 NCHH UHF Digital Handheld Transmitter • AF GAIN (Audio Gain Adjustment) • AF L-CUT (Low-Cut Filter) • AF LIMIT (Audio Limiter) • ENCRYPTION (Encryption Function) 1. Adjustable from 0 dB to 6 dB in 3 dB increments. 2. Increasing the AF GAIN narrows the dynamic range of the input signal and increases the risk of system noise and feedback. 1. Options: L-CUT (Low Cut) or F L AT. 2. When set to L-CUT, the frequency response at 100 Hz is reduced by approximately 3 dB. 1. Options: YES or NO. 2. When set to YES, the maximum output of the receiver is limited. 1. This is a display-only function; it cannot be set on the transmitter. 2. To enable encryption, configure it on the receiver in encryption mode and synchronize using the SYNC function. 3. Refer to the receiver’s encryption settings for more details. 3. The specific group and channel set via PC software will be displayed as “GRP - CH” with asterisks (**) replacing the numbers. 9 NCHH UHF Digital Handheld Transmitter • RF POWER (RF Output Power) Options: HIGH or LOW to adjust RF transmission power. • Mute Mode (Mute Settings) 4. DIS (Disabled) The mute function is turned off and cannot be enabled in this mode. 1. Select between MAN (Manual), AUTO, or DIS (Disabled). 2. MAN (Manual Mute) 3. AUTO (Automatic Mute) • Press the mute button to enter mute mode. The AF MUTE indicator blinks. Press again to unmute. • The mute function is automatically disabled when the transmitter powers off. • When you power the transmitter back on mute will not be engaged. • The transmitter automatically enters mute mode under specific conditions, and the mute button is disabled. • Pointing the microphone head downward mutes the transmitter, while pointing it upward restores audio. • Remaining stationary for over 4 seconds automatically mutes the transmitter. Light movement or usage will unmute. 10 NCHH UHF Digital Handheld Transmitter • Error Codes 1. ROM-ER: Channel not programmed or internal data error. 2. ERROR1: RF frequency targeting circuitry failure. 3. NO-03: The set frequency exceeds the upper limit. Verif…
Text truncated - open the document above for the full version.
Covered list attestation FCC application letter Kiwa RF 755 03 Ce闊前回ItionADDlication Attestation Statements Audix LLC FRN 0015168750 9400 SW Barber Street 97070 Wilsonville , Oregon United States Su同ect:FCC 10: < UC7-NCHH > To Whom It May Concern: Statement for 47 CFR section 2.911 (d )(Sl(i) Page 1 of 2 06-06-2024 1. [Audix LLC] certifies that as of the date of the application the equipment for which authorization is sought is not "covered" equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered" equipment. 2 . [Audix LLC] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab , Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab , Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Additional Explanation: <N/A> Statement for 47 CFR section 2.911 (d)(S)(ii) [Audix LLC] (“the applicant") certifies that, as of the date of the filing of this application, the applicant 口-is I因-is not (3) identified on the Covered List a5 an entity producing“covered" equipment. Date: 2026-04-15 City : Wilsonville Name(2 ) : Chris Pagella Function: Vice President Telephone number: 503-857-9843 Email address: Chris.p a [email protected] Signature: 以心F句d 1 The Commission's Covered List is published by the Public Safety and Homeland Secu討tyBureau and posted on the Commission's website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes "covered" equipment‘httDs:/Iwww.fcc.aov/suDDlvchainlcoveredlist . (2): For FCC it must be the Grantee Code“owner" or the authorized agent. {苟;也ubleclick on the a呻昀priatebox and select "checked"的en"OK"
RF 160 06 Declaration of Authorisalion Iwa (On manufacturer's company letter heading) Declaration of Authorization We Name: Address: City: Country: Declare tha t: Audix LLC 9400 SW Barber Street Wilsonvil悟,Oregon 97070 United States Name Representative of agent: Penny Lin (1) Date of issue 13-08-2025 Agent Company name: Address: City: Worldwide Testing Services (Taiwan) Co. , Ltd. 6F. , No. 58, Ln. 188, Ruey-Kuang Rd., Neihu, Taipei City, Country Taiwan (R.O.C.) is authorized to apply for Certification of the following product(s): Product description: Handheld Transmitter Type designation: NCHH T悶demark:AUDIX Validity/ expi叩date on our behalf. Date: 2026/04/15 City: Wilsonville Name: Chris Pagella Function: Gul470 Signature: Notes: (1): Required for FCC app /ication (勾:For FCC it must be the Grantee Code "owner" or the authorized agent.
FCC, Request for non-disclosure RF _501, Issue 12 kiwa Company Name: Audix LLC Address: 9400 SW Ba巾erStreet Date: 18-08-2025 Page 1 of 2 City: WlIsonville, Oregon 97070 Country: United States To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands 5ubject: Request for confidentiality FCC ID: UC7 -NCHH Reference number: NCHH Dear FCC TCB , 1. Long-Term Con罰dentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in suppo付ofFCC certification application: 口Bill(s)of Material 國BlockDiagrams 國OperationalDescription國SchematicDiagrams 口Tune-upProcedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under47 CFR, section 0.457個)(2).Disclosure or publication or any portion ofthis company confidential material to other pa此iescould cause substantial competitive harm and provide u吋ustified benefits for competitors. 2. 5hort-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission's policy, in order to comply with the marketing regulations in 47 CFR ~2.803 and the importation rules in 47 CFR 32.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): 口InternalPhotos口User'sManual 口TestSet-up Photos 口ExternalPhotos Justi自cation: Date: 2026/04月5Chris Pagella C泛;什Jfæ_ Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Shαt-Term confidentiality is in principle for 45 days from date of grant: it臼nbe extended max 3 times (total time 180 days max.)! The planned date should state的theRF731 application form. 3) FCC must be inforrned when marketing個ginsearlier. 4) Release takes plaωautomatically thus extension must be requested的t州e.Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B. V. at least 7 days before date of actual marketing or before expiration of the STC period ######
Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 24 External Photos Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 8 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 9 of 24
HQ 52 7KLV&RQILGHQWLDOGRFXPHQWLVIRUWKHSXUSRVHVRIUHSDLULQJ0,352SURGXFWVRQO\,WLVIRUELGGHQWRPRGLI \ DGGVHOOSULQWFRS \ LPSURSHUO \ XVHRURIIHUWRWKLUGSDUWLHV2WKHUZLVH0,352ZLOOUHVHUYHWKHUL J KWWRSURFHHGZLWKOH J DODFWLRQ l
Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 10 of 24 Internal Photos Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 11 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 12 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 13 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 14 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 15 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 16 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 17 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 18 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 19 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 20 of 24
of Applicant: Audix LLC Address: 9400 SW Barber Street Wilsonville, Oregon 97070 United States Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 5107A Report No.: W6M22602-24991-EE 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] FCC RF Exposure Exemption report for Handheld Transmitter Model No.: NCHH FCC ID: UC7-NCHH Registration number: W6M22602-24991-EE FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 6 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 NOTES .......................................................................................................................................... 2 1.2 TESTING LABORATORY ................................................................................................................ 3 1.2.1 Location .................................................................................................................................. 3 1.2.2 Details of accreditation status ................................................................................................ 3 1.3 A PPLICATION DETAILS ................................................................................................................. 3 1.4 G ENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.5 T EST STANDARDS ......................................................................................................................... 4 2 TEST CONFIGURATION .............................................................................................................. 5 2.1 T EST ENVIRONMENT .................................................................................................................... 5 2.2 MEASUREMENT UNCERTAINTY .................................................................................................... 5 2.3 T EST EQUIPMENT LIST ................................................................................................................. 5 3 EQUIVALENT ISOTROPIC RADIATED POWER (EIRP)....................................................... 6 3.1 EXEMPTION LIMITS FOR ROUTINE EVALUATION ACCORDING TO FCC KDB PUBLICATION ......... 6 Registration number: W6M22602-24991-EE FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 6 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: June 08, 2026 Sora Kuo Date WTS-Lab. Name Signature Technical responsibility for area of testing: June 08, 2026 Kevin Wang Date WTS Name Signature Registration number: W6M22602-24991-EE FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 6 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) 3 meter semi-anechoic chamber No. 99, Sec. 1, Balian Rd., Xizhi Dist., New Taipei City 221032, Taiwan (R.O.C.) Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. : Name: ./. Accredited no.: ./. Street: ./. Town: ./. Country: ./. 1.3 Application details Approval holder Name: Audix LLC Street: 9400 SW Barber Street City: Wilsonville, Oregon 97070 Country: United States Manufacturer: (if applicable) Name: MIPRO ELECTRONICS CO., LTD. Street: 814, Beigang Rd., City: Chiayi City 600079, Country: Taiwan, R.O.C Date of receipt of test item: February 10, 2026 Date of test: from February 11, 2026 to February 13, 2026 Registration number: W6M22602-24991-EE FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Page 4 of 6 1.4 General information of Test item Type of test item: Handheld Transmitter Model number: NCHH Brand name: AUDIX Multi-listing model number: ./. Sample no.: #01 Technical data Frequency band : 494-608 MHz Frequency (ch A): 494.1 MHz Frequency (ch B): 551 MHz Frequency (ch C): 607.9 MHz Antenna type: Integral Antenna Antenna gain: -0.01dBi Power supply: Battery 3.7Vd.c., 1400mAh, 5.18Wh Operation modes: Simplex Classification: Fixed Device Mobile Device (Human Body distance > 20cm) Portable Device (Human Body distance < 20cm) Modular Radio Device 1.5 Test standards 47 CFR FCC Part 2 Subpart J, section 2.1093 FCC KDB Publication 44…
Text truncated - open the document above for the full version.
QQ IIII LLLL GGGG HQWLDO GGGGG RRRRRRRRR FFFFFF XPHQW L VVVVVVV I RRRRRRRRRRRRR UUUUUUUUUU WWWWW KKKKKK H FFFFFFFFFFFFF HHHHH UUUU WWWW LL II L FFFF DDDDD WLRQ GGGGGGG RRRRRRR F XXXXX PPPPPPP HHHHHHHH QQQQQQQQQQ WWWWWWWWWW V 0,3 5555555 222222222 RRRRRRRR QQQQQQ OOOO \\\\ 1 22222222 7KLV &RQIL GGGGGG HHHHHHHH QWLDO GGGGGGGGG RRRRRRRRRRRRRRRRRRRRRRR FFFFFFFFFFFFFFFFFFFFFFF XX PPPPPPP HHHHHHHHHH QQQQQQQ WWWWWWW LV IR UU WW KK HHHHHHH FFFFFFFFFF H UUU WWWWWWWW LLLLLLL IIIIII L FFFFF DDDDD WL RRRRRR QQQQ GGGGGGGGGGGGGGGGGGGGGGGGGGGGGG RRRRRRRRRRRRRRRRRRRRRRRRRRRRRR FFFFFFFFFFFF XXXXXXXXXXX PPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPP HHHHHHHHHHHHHHHHHHHH QQQQQQQQQQQQQQQQQQ WWWWWWWWWWWWWWWWW VVVVVVVVVVVVVVV 000000000000000000000000000000000 ,,,,,,, 333333333 5555 2 RRRRRRR QO\ 111111 22222222 7KLV &RQ IIII LLLLLL GGGG HQWL DD OOOOO G RRRRRRRRRRRRR FFFFFFFFFFFFFFFFFF XX PPPPPPP HQW LV IIIIIIII RRRRRRR UUUUUU WWWWWW KKKKKKKK HHHHHHHH FFFFFFFF HU WW LL II LL FFFF DDDDDDDDD WWWWW LL RR Q GGGGGGG RRRRRRR FFFFFFFF XXXXXXXX PPPPPPP HHHHHH QQQQQQ WV 0, 3333333 555 2 RRRRRRRRRRRRRRRRRRRR QQQQQQQQ OOOOOOO \\\ 1 22222 777777 KKK LL VVV &&&&&&&& RRRRRRRRR QQQQQQ IIIII LGH QQQQQQQ WWWWWW L DDDDDDDD OOOOO GGGGGGG R F XXXXXXXX PPPP HQW LL VVV IIIIIII RRRRRR U WWWWWWWWWWWWWWWWWWW KKKKKKKKKKKKKKKKKKKKKKKKKKK HH F HHHHHH UUUUUUUU WWWWWW LIL FFFFF DDDDD WLR QQQQQQQQ GR FFFFFF XXXXXX P HHHHHHH QQQQQQ WW VV 0,3 55555555555555555555555555555 2222222222222222222222222 R QQQQQQQQ OOOOOOO \\\\\\\\ 1111111 2 7KLV&RQILGHQWLDOGRFXPHQWLVIRUWKHSXUSRVHVRIUHSDLULQJ0,3 52SURGXFWVRQO\ ,WLVIRUELGGHQWRPRGLI \ DGGVHOOSULQWFRS \ LPSURSHUO \ XVHRURIIHUWRWKLUGSDUWLHV2WKHUZLVH0,352ZLOOUHVHUYHW KHUL J KWWRSURFHHGZLWKOH J DODFWLRQ 1&++$QWHQQD3DWWHUQ0HDVXUHPHQW 1&++$QWHQQD3DWWHUQ0HDVXUHPHQW
of Applicant: Audix LLC Address: 9400 SW Barber Street Wilsonville, Oregon 97070 United States Tested and Prepared By Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22602-24991-C-1 6F., No. 58, Ln. 188, Rueiguang Rd., Neihu Dist., Taipei City , Taiwan (R.O.C.) TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] 47 CFR PART 15 SUBPART C TEST REPORT for Handheld Transmitter Model No.: NCHH FCC ID: UC7-NCHH Registration number: W6M22602-24991-C-1 FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. page 1 of 30 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 N OTES .......................................................................................................................................... 2 1.2 TESTING LABORATORY ................................................................................................................ 3 1.3 D ETAILS OF APPROVAL HOLDER ................................................................................................... 3 1.4 A PPLICATION DETAILS ................................................................................................................. 3 1.5 GENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.6 T EST STANDARDS ......................................................................................................................... 4 2 TECHNICAL TEST ......................................................................................................................... 5 2.1 S UMMARY OF TEST RESULTS ........................................................................................................ 5 2.2 TEST ENVIRONMENT .................................................................................................................... 5 2.3 TEST EQUIPMENT LIST ................................................................................................................. 6 2.4 G ENERAL TEST PROCEDURE ........................................................................................................ 7 3 TEST RESULTS (ENCLOSURE) .................................................................................................. 8 4 RF POWER OUTPUT, FCC15.236 (D) .......................................................................................... 9 4.1 T EST PROCEDURE ......................................................................................................................... 9 4.2 TEST RESULTS ........................................................................................................................... 10 5 OCCUPIED BANDWIDTH, FCC15.236 (F) / EMISSION MASK, FCC15.236 (G) .............. 16 5.1 T EST PROCEDURE ...................................................................................................................... 16 5.2 T EST RESULTS ............................................................................................................................ 16 6 RADIATED SPURIOUS EMISSION, FCC 15.236(G) ........................................................... 21 6.1 T EST PROCEDURE ....................................................................................................................... 21 6.2 T EST RESULTS ............................................................................................................................ 21 7 FREQUENCY STABILITY, FCC 15.236(F)(3) .......................................................................... 22 7.1 T EST PROCEDURE ....................................................................................................................... 22 7.2 T EST RESULTS ............................................................................................................................ 22 8 POWER LINE CONDUCTED EMISSION, FCC 15.207 ........................................................... 24 8.1 T EST PROCEDURE ....................................................................................................................... 24 8.2 T EST RESULTS ........................................................................................................................... 24 Registration number: W6M22602-24991-C-1 FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. page 2 of 30 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: June 08, 2026 Sora Kuo Date WTS-Lab. Name Signature Technical responsibility for area of testing: June 08, 2026 Kevin Wang Date WTS-Lab. Name Signature Registration number: W6M22602-24991-C-1 FCC ID: UC7-NCHH W…
Text truncated - open the document above for the full version.
Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 21 of 24 Set Up Photo of Radiated Emission Below 1GHz Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 22 of 24 Above 1GHz Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 23 of 24 Registration number: W6M22602-24991-FCC FCC ID: UC7-NCHH Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 24 of 24 Set Up Photo of Conducted Emission
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 15C | 494.1 MHz - 607.9 MHz | 8.60 mW | 194KD1D | 6.5900000000Hz |