FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Kaicom CO, LTD/
  3. UGN-KPI-2210

UGN-KPI-2210FD- Repeater

Kaicom CO, LTD
FD- Repeater - FCC ID UGN-KPI-2210 - Kaicom CO, LTD
Click to zoom

Application Details

Equipment Class
BPL - Access Broadband Over Powerline System
Date of Grant
Mar 07, 2007
Application Purpose
Original Equipment
Date of Application
Jan 08, 2007
Equipment Note
FD- Repeater
Frequency Range
2.00000000 - 29.50000000
Company
Kaicom CO, LTD
Country
South Korea

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

attestation letter.doc 1 of 1 December 14, 2006 Test Report Attestation According to the testing performed by Product Safety Engineering, the Kaicom CO. Ltd. model 2210 is in compliance with the electromagnetic compatibility requirements in FCC rules, Part 15, Subpart G. Details are shown in the accompanying test report.

Attestation Statements

attestation letter.doc 1 of 1 December 14, 2006 Test Report Attestation According to the testing performed by Product Safety Engineering, the Kaicom CO. Ltd. model 2210 is in compliance with the electromagnetic compatibility requirements in FCC rules, Part 15, Subpart G. Details are shown in the accompanying test report.

Cover Letter(s)

www.kaicom.co.kr Page 1/1 Kaicom Co., Ltd. 109, Gayang Techno Town 1487, Gayang-3Dong, Kangseo-Gu, Seoul, 157-810, Korea Tel : 82 2 6734 6777, Fax : 82 2 6734 6776 4 December 2006 Federal Communication Commission 7435 Oakland Mills Road Columbia, MD 21046 Attn: All persons in charge Re: Request for confidentiality per Section 0.457 and 0.459 of FCC Rules Applicant: Kaicom Co., Ltd. FCC ID: UGN-KPI-2210 Gentlemen, The materials submitted by Kaicom Co., Ltd. for FCC exhibitions for FCC certification of access BPL equipments are containing lots of confidential contents to maintain a competitive position in the arena. Therefore, according to the Section 0.457 and 0.459 of the FCC rules, here we Kaicom Co., Ltd. wishes that the following documents regarding the submission of FCC ID: UGN-KPI-2210 are to be kept with confidentiality. z Schematics z Block diagrams z Operational/Functional Descriptions z User Manuals (not accessible to end users) z Internal Photos of equipment For further information or any questions, please contact referring to the signed information below. Sincerely, ---------------------------------- Y. C. Kim Director / Kaicom Research & Development Laboratory Phone: +82-2-6734-6777 Fax: +82-2-6734-6776 E-mail: [email protected]

Cover Letter(s)

www.kaicom.co.kr Page 1/1 Kaicom Co., Ltd. 109, Gayang Techno Town 1487, Gayang-3Dong, Kangseo-Gu, Seoul, 157-810, Korea Tel : 82 2 6734 6777, Fax : 82 2 6734 6776 4 December 2006 Federal Communication Commission 7435 Oakland Mills Road Columbia, MD 21046 Attn: All persons in charge Re: Request for confidentiality per Section 0.457 and 0.459 of FCC Rules Applicant: Kaicom Co., Ltd. FCC ID: UGN-KPI-2210 Gentlemen, The materials submitted by Kaicom Co., Ltd. for FCC exhibitions for FCC certification of access BPL equipments are containing lots of confidential contents to maintain a competitive position in the arena. Therefore, according to the Section 0.457 and 0.459 of the FCC rules, here we Kaicom Co., Ltd. wishes that the following documents regarding the submission of FCC ID: UGN-KPI-2210 are to be kept with confidentiality. z Schematics z Block diagrams z Operational/Functional Descriptions z User Manuals (not accessible to end users) z Internal Photos of equipment For further information or any questions, please contact referring to the signed information below. Sincerely, ---------------------------------- Y. C. Kim Director / Kaicom Research & Development Laboratory Phone: +82-2-6734-6777 Fax: +82-2-6734-6776 E-mail: [email protected]

Cover Letter(s)

Correspondence Reference Number: 32554 1) Upload coupler photos to the external photos exhibit. Please see uploaded file named UGN-KPI-2210 Coupler photos.pdf. 2) Is this device used for common mode injection, differential mode injection, or both? Which mode of injection was tested? The device operates in common mode and was tested in common mode. 3) The User's Manual indicates that there is a master mode and a slave mode. How do these modes differ and what mode(s) were tested? In order to establish communications between any two units, one unit must be set as master and the other unit must be set as slave. The master / slave modes are merely protocols used for data synchronization. The transmission levels are identical in either mode. 4) This device has two connections, I assume for couplers. Explain how these ports were configured for testing. The device was tested first in mode (10) while port (a) was connected to a dedicated coupler. The device was then set for mode (11) while port (b) was connected to a second dedicated coupler. This was how the MV lines were tested. During the LV line testing, the MV couplers were disconnected from both ports and a coaxial cable was connected between port (a) and port (L) while running in mode (10) and then again with the coaxial cable connected between port (b) and port (L) while running in mode (11). Port (L) routes the BPL signals back inside the unit, through the internal power supply and then back to the (220) VAC input lines. 5) The Test Report states that the power setting was set to the maximum. Was this for both overhead and underground configurations? The device was 0.1 dB from the limit. Please explain the power settings available and how they are to be used. The power level setting used during testing are described at the end of the previously uploaded attachment – UGN-KPI-2210 Circuit Description.pdf. 6) The User's Manual is not clear how the utility would set the notch is there was a complaint on a specific frequency. Please clarify how this would be done. Please see uploaded file named UGN-KPI-2210 Mitigation Methodology.pdf.

Test Report

Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Test Report Number 06F2718B3 Page 1 of 10 Certification # 1367-01 TEST REPORT Laboratory IDSubmitter ID PRODUCT SAFETY ENGINEERING, INC.Kaicom CO., Ltd 109, Gayang Techno Town 1487 12955 Bellamy Brothers BoulevardGayang-dong, Kangso-Gu Dade City, Florida 33525 USASeoul PH (352) 588-2209 FX (352) 588-2544South Korea Report Issue Date: 08 Jan 2007 Test Report Number:06F271B3 Sample S/N: NA Model Designation: 2210 Sample Receipt Date: 07/27/06 Product Description: Access BPL Sample Test Date: 08/15/06 -12/03/06 Marketing Approval Description of non-standard test method or test practice: None Estimated Measurement Uncertainty: Not Applicable Special limitations of use: None Traceability: reference standards of measurement have been calibrated by a competent body using standards traceable to the NIST. According to testing performed at Product Safety Engineering, Inc., the above-mentioned unit is in compliance with the electromagnetic compatibility requirements defined in regulations indicated on page (3) of the test report. The test results contained herein relate only to the model(s) identified above. It is the manufacturer’s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical characteristics. As the responsible EMC Project Engineer, I hereby declare that the equipment tested as specified above conforms to the requirements indicated on page (3) of the test report. Signature Name David Foerstner Title Engineering Group Leader Date 08 Jan 2007 Reviewed by: Approved Signatory Date 08 Jan 2007 This report may only be reproduced in full without written permission from Product Safety Engineering, Inc. Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Test Report Number 06F2718B3 Page 2 of 10 D I R E C T O R Y - EMISSIONS Page(s) A)Documentation Test report1 - 10 Directory2 Test Regulations3 General Remarks10 B)Test data Conducted emissions10/150 kHz - 30 MHz5, 9 Radiated emissions10 kHz - 30 MHz5, 9 Radiated emissions30 MHz - 1000 MHz6, 9 Interference Mitigation / Excluded BandsAs Required6, 9 Equivalent Radiated emissions1 GHz - 18 GHz7, 9 Antenna Disturbance Voltage30 MHz - 1,000 MHz7,9 C)Appendix A Test Equipment Calibration Information Description of Testing Test Data Sheets A2 A3 - A10 A11 -A23 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Test Report Number 06F2718B3 Page 3 of 10 EMISSIONS TEST REGULATIONS : The emissions tests were performed according to following regulations: 9 - EN 61000-6-3:2001 9 - EN 61000-6-4:2001 9 - EN 55011 : 1998 / A1:19999 - Group 19 - Group 2 9 - Class A9 - Class B 9 - EN 55013 : 1990 / A12:1994 / A13:1996 / A14:1999 9 - EN 55014 -1: 20019 - Household appliances and similar 9 - Portable tools 9 - Semiconductor devices 9 - EN 55022 (1998) /A1:2001 /A2:20039 - Class A9 - Class B 9 -AS/NZS 3548:19959 - Class A9 - Class B 9 - ICES-0039 - Class A9 - Class B 9 - CNS 134389 - Class A9 - Class B 9 - VCCI : 19999 - Class A9 - Class B # - FCC Part 15 Sub Part G9 - Class A9 - Class B “General Technical Requirements” # - Certification 9 - Verification 9 - Declaration of Conformity 9 - FCC Part 18 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Test Report Number 06F2718B3 Page 4 of 10 Environmental conditions during testing: LAB OATS Temperature: * _________: ________ Relative Humidity: ** _________: ________ * The ambient temperature during the testing was within the range of (50 - 104 F) unless indicted above. oo ** The humidity levels during the testing was within the range of (10% - 90%) relative humidity unless indicated above. Power supply system: 110 Volts 60 Hz SINGLE phase Sign Explanations: 9 - not applicable # - applicable Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Test Report Number 06F2718B3 Page 5 of 10 Emissions Test Conditions: CONDUCTED EMISSIONS (Interference Voltage) The CONDUCTED EMISSIONS (INTERFERENCE VOLTAGE) measurements were performed at the following test location: # - Test not applicable 9 - Darby Test Site (Open Area Test Site) 9 - Darby Laboratory Test equipment used : Model NumberManufacturerDescriptionSerial Number 9 -8028-50Solar50 S LISN829012, 829022 9 -3825/2Solar50 S LISN924840 9 -EMC-30Electro-MetricsEMI Receiver191 9 -8566BHewlett-PackardSpectrum Analyzer2421A00526 9 -85650AHewlett-PackardQuasi-Peak Adapter2043A00209 9 -85662AHewlett Packard Analyzer Display2403A07352 9 -8028-50Solar50 S LISN903725, 903726 9 -FCC-TLISN-T4Fisher Custom Com.Telecom ISN20072 Emissions Test Conditions: RADIATED EMISSIONS (Magnetic Field) The RADIATED EMISSIONS (MAGNETIC FIELD) measurements were performed at the following test location: 9 - Darby Test Site (Open Area Test Site) # - In-Situ Testing (Vernon, NY & Valrico, FL) 9 - at a test distance of : 9 - 3 meters # - 10 meters 9 - Test not applicable Test equipment used : Model NumberManufacturerDescriptionSerial Number 9 -96005EatonLog Periodic Antenna1099 9 -BIA-25Electro-MetricsBiconical Antenna4283 9 -8566BHewlett-PackardSpectrum Analyzer2421A00526 9 -85662AHewlett-PackardAnalyzer Display2403A07352 9 -85650AHewlett-PackardQuasi-Peak Adapter2043A00209 # -ALR-30MElectro-MetricsLoop Antenna824 # -E7402AHewlett PackardSpectrum AnalyzerUS39150137 9 - 9 - EMC-30 ALA-130/A Electro-Metrics Antenna Research EMI Receiver Loop Antenna 191 106 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Test Report Number 06F2718B3 Page 6 of 10 Emissions Test Conditions: RADIATED EMISSIONS (Electric Field) The RADIATED EMISSIONS (ELECTRIC FIELD) measurements, in the frequency range…

Text truncated - open the document above for the full version.

Test Report

EXCLUDED BANDS Band 1 (2,850-3,025) kHz Band 2 (3,400-3,500) kHz Band 3 (4,650-4,700) kHz Band 4 (5,450-5,680) kHz Band 5 (6,525-6,685) kHz Band 6 (8,815-8,965) kHz Band 7 (10,005-10,100) kHz Band 8 (11,275-11,400) kHz Band 9 (13,260-13,360) kHz Band 10 (17,900-17,970) kHz Band 11 (21,924-22,000) kHz Band 12 (74.8-75.2) MHz

Contact Information

Applicant

Byung H Yang(General Manager)
[email protected]+82-16-843-6487Fax: none

Technical Contact

Product Safety EngineeringSteven E Hoke
[email protected]352-588-2209

12955 Bellamy Bros. Blvd · Dade City, Florida · United States

Non-Technical Contact

Product Safety EngieeringSteven E Hoke
[email protected]352-588-2209

Test Firm

TUV SUD America Inc.William Elliott
[email protected]813-284-2736Fax: 888 413 3813

Technical Specifications

#Rule PartsFrequency RangePower Output
115G2 MHz - 29.5 MHz-
Confidentiality
Long Term

Other Applications from Kaicom CO, LTD

Gateway - FCC ID UGN-KPI-2330 - Kaicom CO, LTD
UGN-KPI-2330

Gateway

Mar 08, 2007

Equipment Class

BPL - Access Broadband Over Powerline System
FD-Repeater - FCC ID UGN-KPI-2220E - Kaicom CO, LTD
UGN-KPI-2220E

FD-Repeater

Jan 11, 2007

Equipment Class

BPL - Access Broadband Over Powerline System