Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 16, 2015
Application Purpose
Original Equipment
Date of Application
Jul 13, 2015
Equipment Note
Touchstone Data Gateway
Frequency Range
5745.00000000 - 5825.00000000
Company
ARRIS
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Touchstone ® DG1660 Data Gateway User’s Guide Get ready to experience the Internet’s express lane! Whether you’re checking out streaming media, downloading new software, checking your email, or talking with friends on the phone, the Touchstone DG1660 Data Gateway brings it all to you faster and more reliably with both wired and wireless connectivity. The Touchstone Data Gateway provides four Ethernet connections for use as the hub of your home/office Local Area Network (LAN). The Data Gateway also pro- vides 802.11b/g/n wireless connectivity for enhanced mobility and versatility. Installation is simple and your cable company will provide assistance to you for any special requirements. The links below provide more detailed instructions. Safety Requirements Getting Started Installing and Connecting Your Data Gateway Configuring Your Ethernet Connection Using the Data Gateway Troubleshooting Glossary Export Regulations This product may not be exported outside the U.S. and Canada without U.S. Department of Commerce, Bureau of Export Admin istration au- thorization. Any export or re-export by the purchaser, directly or indirectly, in contravention of U.S. Export Adminis tration Regulation is prohib- ited. ©ARRIS Enterprises, Inc. 2013 All rights reserved. No part of this publication may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from ARRIS Enterprises, Inc. (“ARRIS”). ARRIS reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of ARRIS to provide notification of such revision or change. ARRIS provides this guide without warranty of any kind, implied or expressed, including, but not limited to, the implied warranties of mer- chantability and fitness for a particular purpose. ARRIS may make improvements or changes in the product(s) described in this manual at any time. The capabilities, system requirements and/or compatibility with third-party products described herein are subject to change without no- tice. ARRIS and the ARRIS logo are all trademarks of ARRIS Enterprises, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and the names of their products. ARRIS disclaims proprietary interest in the marks and names of others. Protected under one or more of the following U.S. patents: 7,031,435; 7,916,744. Other patents pending. Release 16 Draft 1.0 June 2013 Safety Requirements ARRIS Data Gateways comply with the applicable requirements for performance, construction, labeling, and information when used as outlined below: CAUTION Risk of shock Mains voltages inside this unit. No user serviceable parts inside. Refer service to qualified personnel only! • Do not use product near water (i.e. wet basement, bathtub, sink or near a swimming pool, etc.), to avoid risk of electrocu tion. • The product shall be cleaned using only a damp, lint-free, cloth. No sol- vents or cleaning agents shall be used. • Do not use spray cleaners or aerosols on the gateway. • Avoid using and/or connecting the equipment during an electri cal storm, to avoid risk of electrocution. • Do not locate the equipment within 6 feet (1.9 m) of a flame or ignition source (i.e. heat registers, space heaters, fireplaces, etc.). • Use only power supply and power cord included with the equip ment. • Equipment should be installed near the power outlet and should be easily accessible. • The shield of the coaxial cable must be connected to earth (grounded) at the entrance to the building in accordance with applicable national electrical in- stallation codes. In the U.S., this is required by NFPA 70 (National Electrical Code) Article 820. In the European Union and in certain other countries, CATV instal lation equipotential bonding requirements are specified in IEC 60728-11, Cable networks for television signals, sound signals and interac- tive services, Part 11: Safety. This equipment is in tended to be installed in accordance with the requirements of IEC 60728-11 for safe operation. Touchstone DG1660 Data Gateway User’s Guide Safety Getting Started Installation Ethernet Configuration UsageTroubleshootingGlossary 3 If the equipment is to be installed in an area serviced by an IT power line network, as is found in many areas of Norway, spe cial attention should be given that the installation is in accor dance with IEC 60728-11, in particular Annex B and Figure B.4. • In areas of high surge events or poor grounding situations and areas prone to lightning strikes, additional surge protection may be required (i.e. PF11VNT3 from American Power Conver sion) on the AC, RF, Ethernet and Phone lines. • When the Data Gateway is connected to a local computer through Ethernet cables, the computer must be proper ly grounded to the building/residence AC ground network. All plug-in cards within the computer must be properly installed and grounded to the computer frame per the manufacturer’s spec- ifications. • Ensure proper ventillation. Position the Data Gateway so that air flows freely around it and the ventillation holes on the unit are not blocked. • Do not mount the Data Gateway on surfaces that are sensitive to heat and/or which may be damaged by the heat generated by the modem, its power supply, or other accessories. Touchstone DG1660 Data Gateway User’s Guide Safety Getting Started Installation Ethernet Configuration UsageTroubleshootingGlossary 4 FCC Part 15 This equipment has been tested and found to comply with the requirements for a Class B digital device under Part 15 of the Federal Communications Commission (FCC) rules. These requirements are intended to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in ac- cordance with the instructions, may cause ha…

Text truncated - open the document above for the full version.

Users Manual

Touchstone ® DG1670 Data Gateway User’s Guide Get ready to experience the Internet’s express lane! Whether you’re checking out streaming media, downloading new software, checking your email, or talking with friends on the phone, the Touchstone DG1670 Data Gateway brings it all to you faster and more reliably with both wired and wireless connectivity. The Touchstone Data Gateway provides four Ethernet connections for use as the hub of your home/office Local Area Network (LAN). The Data Gateway also pro- vides 802.11b/g/n wireless connectivity for enhanced mobility and versatility. The Data Gateway also offers integrated MoCA 1.1 home networking providing Internet access and transfer of multimedia content between devices over coaxial cable in the home. Installation is simple and your cable company will provide assistance to you for any special requirements. The links below provide more detailed instructions. Safety Requirements Getting Started Installing and Connecting Your Data Gateway Configuring Your Ethernet Connection Using the Data Gateway Troubleshooting Glossary Export Regulations This product may not be exported outside the U.S. and Canada without U.S. Department of Commerce, Bureau of Export Admin istration au- thorization. Any export or re-export by the purchaser, directly or indirectly, in contravention of U.S. Export Adminis tration Regulation is prohib- ited. ©ARRIS Enterprises, Inc. 2013 All rights reserved. No part of this publication may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from ARRIS Enterprises, Inc. (“ARRIS”). ARRIS reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of ARRIS to provide notification of such revision or change. ARRIS provides this guide without warranty of any kind, implied or expressed, including, but not limited to, the implied warranties of mer- chantability and fitness for a particular purpose. ARRIS may make improvements or changes in the product(s) described in this manual at any time. The capabilities, system requirements and/or compatibility with third-party products described herein are subject to change without no- tice. ARRIS and the ARRIS logo are all trademarks of ARRIS Enterprises, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and the names of their products. ARRIS disclaims proprietary interest in the marks and names of others. Protected under one or more of the following U.S. patents: 7,031,435; 7,916,744. Other patents pending. Release 16 Draft 1.0b July 2013 Safety Requirements ARRIS Data Gateways comply with the applicable requirements for performance, construction, labeling, and information when used as outlined below: CAUTION Risk of shock Mains voltages inside this unit. No user serviceable parts inside. Refer service to qualified personnel only! • Do not use product near water (i.e. wet basement, bathtub, sink or near a swimming pool, etc.), to avoid risk of electrocu tion. • The product shall be cleaned using only a damp, lint-free, cloth. No sol- vents or cleaning agents shall be used. • Do not use spray cleaners or aerosols on the gateway. • Avoid using and/or connecting the equipment during an electri cal storm, to avoid risk of electrocution. • Do not locate the equipment within 6 feet (1.9 m) of a flame or ignition source (i.e. heat registers, space heaters, fireplaces, etc.). • Use only power supply and power cord included with the equip ment. • Equipment should be installed near the power outlet and should be easily accessible. • The shield of the coaxial cable must be connected to earth (grounded) at the entrance to the building in accordance with applicable national electrical in- stallation codes. In the U.S., this is required by NFPA 70 (National Electrical Code) Article 820. In the European Union and in certain other countries, CATV instal lation equipotential bonding requirements are specified in IEC 60728-11, Cable networks for television signals, sound signals and interac- tive services, Part 11: Safety. This equipment is in tended to be installed in accordance with the requirements of IEC 60728-11 for safe operation. Touchstone DG1670 Data Gateway User’s Guide Safety Getting Started Installation Ethernet Configuration UsageTroubleshootingGlossary 3 If the equipment is to be installed in an area serviced by an IT power line network, as is found in many areas of Norway, spe cial attention should be given that the installation is in accor dance with IEC 60728-11, in particular Annex B and Figure B.4. • In areas of high surge events or poor grounding situations and areas prone to lightning strikes, additional surge protection may be required (i.e. PF11VNT3 from American Power Conver sion) on the AC, RF, Ethernet and Phone lines. • When the Data Gateway is connected to a local computer through Ethernet cables, the computer must be proper ly grounded to the building/residence AC ground network. All plug-in cards within the computer must be properly installed and grounded to the computer frame per the manufacturer’s spec- ifications. • Ensure proper ventillation. Position the Data Gateway so that air flows freely around it and the ventillation holes on the unit are not blocked. • Do not mount the Data Gateway on surfaces that are sensitive to heat and/or which may be damaged by the heat generated by the modem, its power supply, or other accessories. Touchstone DG1670 Data Gateway User’s Guide Safety Getting Started Installation Ethernet Configuration UsageTroubleshootingGlossary 4 FCC Part 15 This equipment has been tested and found to comply with the requirements for a Class B digital device under Part 15 of the Federal Communications Commission (FCC) rules. These requirements are intended to provide reasonable protection against harmful interference in a res…

Text truncated - open the document above for the full version.

Cover Letter(s)

3871 Lakefield Drive • Suwanee, GA 30024 • phone: 678-473-8400 www.arrisi.com July 22, 20113 Federal Communications Commission Date: Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: ARRIS International, Inc. respectfully requests confidentiality of certain materials provided with the submission of the DG1670A, DG1660A under FCC ID: UIDDG1670 in accordance with 47 CFR 0.457(d) and 47 CFR 0.459. The confidentiality request applies to the (1) schematic diagrams, (2) detailed block diagrams, and (3) detailed operational descriptions contained in this filing and included in the following files: 12-0356 – System Block Diagram.pdf 12-0356 – DG1670A Schematics Part 1 of 2.pdf 12-0356 – DG1670A Schematics Part 2 of 2.pdf 12-0356 – DG1660A Schematics Part 1 of 2.pdf 12-0356 – DG1660A Schematics Part 2 of 2.pdf 12-0356 – Theory of Operation.pdf The DG1670A, DG1660A has been developed at considerable effort and expense by ARRIS International, Inc.. These items are considered as Trade Secrets and therefore public access to the proprietary material could possibly result in duplication of equipment that could severely damage the company's business advantage. I appreciate your assistance in this matter. Sincerely, Name: Edward R. Champion, Jr.Signature: Title: Manager, Regulatory/ComplianceDate: 07/22/2013

External Photos

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: UIDDG1670 IC: 6670A-DG1670 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0356 Manufacturer: Arris International, Inc. Model: DG1670A, DG1660A External Photos Models: DG1670A, DG1660AFCC ID: UIDDG1670IC: 6670A-DG1670 ACS Project: 12-0356Advanced Compliance SolutionsPage 2 Figure 1: External Photo Models: DG1670A, DG1660AFCC ID: UIDDG1670IC: 6670A-DG1670 ACS Project: 12-0356Advanced Compliance SolutionsPage 3 Figure 2: External Photo Models: DG1670A, DG1660AFCC ID: UIDDG1670IC: 6670A-DG1670 ACS Project: 12-0356Advanced Compliance SolutionsPage 4 Figure 3: External Photo

ID Label/Location Info

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: UIDDG1670 IC: 6670A-DG1670 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0356 Manufacturer: Arris International, Inc. Model: DG1670A, DG1660A Label Information Models: DG1670A, DG1660AFCC ID: UIDDG1670IC: 6670A-DG1670 ACS Project: 12-0355Advanced Compliance SolutionsPage 2 Figure 1: Label Placement Label Placement .#$'.4')7.#614; &)# % ARRIS LOGO TYPE SHOWN IS FOR POSITION ONLY USE ARRIS APPROVED CAMERAREADY ART PER QMS0075/7.1 NOTES: 1. MATERIAL: SEE BOM FOR MATERIAL APPLICATION. 2. ALL LABEL CORNERS: 0.8mm RADIUS. 3. PRE-PRINTED COLORS: BACKGROUND: ARRIS CHARCOAL GRAY; TEXT AND GRAPHICS: WHITE AS NOTED WITH CROSS HATCHING 4. FACTORY PRINTING: BACKGROUND: WHITE; TEXT AND BARCODE: BLACK 5. TYPE: ARIAL REGULAR; TEXT HEIGHT: 6 POINT MINIMUM. 6. ALL LABEL MARKINGS MUST COMPLY WITH ARDO00454 - MARKING REQUIREMENTS FOR ARRIS BROADBAND PRODUCTS. 7. BARCODE SYMBOLOGY TO BE CODE 128 FORMAT AND SHOULD BE A MINIMUM HEIGHT OF 3.7MMM. # 4'.'#5'2'4'$Ä 59 %4 MILLIMETERS TM 1(  %459 BACKGROUND COLOR: ARRIS CHARCOAL GRAY TEXT AND GRAPHICS: WHITE BACKGROUND COLOR: WHITE PRE-PRINTED LABEL FACTORY PRINTED LABEL REGULATORY MARKS ARE FOR REFERENCE ONLY USE AGENCY APPROVED CAMERAREADY ART 116.9 [4.60] 50.0 [1.97] WPS PIN:XXXXXXXX SN:A4TBPN323100537 CM MAC:0015D13A9D2C WAN MAC:0015D13A9D2E Network Name (SSID) 2.4GHz: ARRIS - XXXX 5GHz: ARRIS - XXXX-5G Preshared Key: Security Mode:WPA2-PSK (AES) 1 C THE CONTENTS OF THIS MATERIAL ARE CONFIDENTIAL AND PROPRIETARY TO ARRIS AND SHOULD NOT BE USED,REPRODUCED, PUBLISHED OR DISCLOSED TO OTHERS WITHOUT LABEL INFORMATION Model 2.4G Field 5G Field 2.4/5G WiFi Radio Decorder Security Mode Field Network or Pre-Shared Key Fields 1 2 3 4 Time Warner "DG1670AXX" "DG1670AXX-5G" "XX" ("XX" = LAST 2 CHARACTERS OF CMAC ADDRESS). Use for 2.4G and 5G field descriptions "WPA2-PSK (AES)" "DG1670AXXXXXX"( "XXXXXX")= last six digits of CMAC address). Use field description "Pre-Shared Key" ARRIS "ARRIS-XXXX" "ARRIS-XXXX-5G" "XXXX" ("XXXX" = LAST 4 CHARACTERS OF CMAC ADDRESS). Use for 2.4G and 5G field descriptions "WPA2-PSK (AES)" "XXXXXXXXXXXX"( "XXXXXXXXXXXX")= last 12 digits of S/N). Use field description "Pre-Shared Key" SEE TABLE, COLUMN 1 SEE TABLE, COLUMN 2 SEE TABLE, COLUMN 4 SEE TABLE, COLUMN 3 WPS PIN - 8 RANDOM GENERATED NUMBERS $ 4'.'#5'2'4'$Ä ,(0 %4 CM 4( +6' RoHS 2002/95/EC DANGER Mains voltages inside this unit. No user serviceable parts inside. Refer service to qualified personnel only Š FCC ID: UIDDG1670 IC: 6670A-DG1670 This device complies with Part 15 of the FCC Rules and Industry Canada requirements. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. &HWDSSDUHLOQXPpULTXHGHODFODVVH%HVWFRQIRUPHjODQRUPH NMB-003 du Canada. 115-240 VAC,50/60 Hz,0.7 A MAX US Pat. 7,695,853; 7,031,435; 7,024,185;7,916,744; 2WKHUSDWHQWVSHQGLQJ‹$55,6 All rights reserved. Made in China. Model: DG1670A P/N: DG00DLQ1670 CM 4( +6' RoHS 2002/95/EC DANGER Mains voltages inside this unit. No user serviceable parts inside. Refer service to qualified personnel only Š FCC ID: UIDDG1670 IC: 6670A-DG1670 This device complies with Part 15 of the FCC Rules and Industry Canada requirements. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. &HWDSSDUHLOQXPpULTXHGHODFODVVH%HVWFRQIRUPHjODQRUPH NMB-003 du Canada. 115-240 VAC,50/60 Hz,0.7 A MAX US Pat. 7,695,853; 7,031,435; 7,024,185;7,916,744; 2WKHUSDWHQWVSHQGLQJ‹$55,6 All rights reserved. Made in China. Model: DG1670A P/N: DG00DLQ1670 % 4'.'#5'2'4'$Ä ,(0 %4 .#$'.4')7.#614; &)# % ARRIS LOGO TYPE SHOWN IS FOR POSITION ONLY USE ARRIS APPROVED CAMERAREADY ART PER QMS0075/7.1 NOTES: 1. MATERIAL: SEE BOM FOR MATERIAL APPLICATION. 2. ALL LABEL CORNERS: 0.8mm RADIUS. 3. PRE-PRINTED COLORS: BACKGROUND: ARRIS CHARCOAL GRAY; TEXT AND GRAPHICS: WHITE AS NOTED WITH CROSS HATCHING 4. FACTORY PRINTING: BACKGROUND: WHITE; TEXT AND BARCODE: BLACK 5. TYPE: ARIAL REGULAR; TEXT HEIGHT: 6 POINT MINIMUM. 6. ALL LABEL MARKINGS MUST COMPLY WITH ARDO00454 - MARKING REQUIREMENTS FOR ARRIS BROADBAND PRODUC 7. BARCODE SYMBOLOGY TO BE CODE 128 FORMAT AND SHOULD BE A MINIMUM HEIGHT OF 3.7MMM. # 4'.'#5'2'4'$Ä Ä %4 MILLIMETERS TM 1(  %4,(0 BACKGROUND COLOR: ARRIS CHARCOAL GRAY TEXT AND GRAPHICS: WHITE BACKGROUND COLOR: WHITE PRE-PRINTED LABEL FACTORY PRINTED LABEL REGULATORY MARKS ARE FOR REFERENCE ONLY USE AGENCY APPROVED CAMERAREADY ART 116.9 [4.60] 50.0 [1.97] WPS PIN:XXXXXXXX SN:A4TBPN323100537 CM MAC:0015D13A9D2C WAN MAC:0015D13A9D2E Network Name (SSID) 2.4GHz: ARRIS - XXXX 5GHz: ARRIS - XXXX-5G Preshared Key: Security Mode: WPA2-PSK (AES) 1 C THE CONTENTS OF THIS MATERIAL ARE CONFIDENTIAL AND PROPRIETARY TO ARRIS AND SHOULD NOT BE USED,REPRODUCED, PUBLISHED OR DISCLOSED TO OTHERS WITHOUT LABEL INFORMATION Model 2.4G Field 5G Field 2.4/5G WiFi Radio Decorder Security Mode Field Network or Pre-Shared Key Fields 1 2 3 4 ARRIS "ARRIS-XXXX" "ARRIS-XXXX-5G" "XXXX" ("XXXX" = LAST 4 CHARACTERS OF CMAC ADDRESS). Use for 2.4G and 5G field descriptions "WPA2-PSK (AES)" "XXXXXXXXXXXX"( "XXXXXXXXXXXX")= last 12 digits of S/N). Use field description "Pre-Shared Key" SEE TABLE, COLUMN 1 SEE TABLE, COLUMN 2 SEE TABLE, COLUMN 4 SEE TABLE, COLUMN 3 WPS PIN - 8 RANDOM GENERATED NUMBERS $ 4'.'#5'2'4'$Ä ,(0 %4 CM 4( +6' RoHS 2002/95/EC DANGER Main…

Text truncated - open the document above for the full version.

Internal Photos

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: UIDDG1670 IC: 6670A-DG1670 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0356 Manufacturer: Arris International, Inc. Model: DG1670A, DG1660A Internal Photos Models: DG1670A, DG1660AFCC ID: UIDDG1670IC: 6670A-DG1670 ACS Project: 12-0356Advanced Compliance SolutionsPage 2 Figure 1: Internal Photo Figure 2: Internal Photo Models: DG1670A, DG1660AFCC ID: UIDDG1670IC: 6670A-DG1670 ACS Project: 12-0356Advanced Compliance SolutionsPage 3 Figure 3: Internal Photo – DG1670A – Shields Removed Figure 4: Internal Photo – DG1660A –Shields Removed

RF Exposure Info

§ 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5150-5250 MHz; Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4πR2 or R = √PG / 4πS where, S = Power Density P = Power Input to antenna=20.79 dBm (119.94 mW) G = Antenna Gain 3 dBi, 1.99 linear) R = Minimum Distance between User and Antenna (20cm) S = (1.99*119.94 )/(4*3.14*400 ) = 0.05 mW/cm2 Since S < 1 mW/cm2, the minimum distance (R) is 20cm

RF Exposure Info

§ 15.407(f) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5745-5825 MHz; Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4πR2 or R = √PG / 4πS where, S = Power Density P = Power Input to antenna =22.53 dBm = 179.06 mW G = Antenna Gain 3 dBi (1.99 inear) R = Minimum Distance between User and Antenna (20 cm) S = (179.06*1.99)/(4*3.14*400 ) = 0.07 mW/cm2 Therefore the uncontrolled exposure limit is achieved at 20 cm.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408) 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory July 14, 2015 ARRIS Group, Inc. 3871 Lakefield Drive, Suite 300 Suwanee, Georgia 30024 Dear Tony Figueiredo, Enclosed is the EMC Wireless test report for Class II Permissive Change compliance testing of the ARRIS Group, Inc., DG1660/DG1670 as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Title 47 of the CFR, Part 15.407, Subpart E (UNII 1) for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Amy Graziano Documentation Department Reference: (\ARRIS Group, Inc.\ EMC85688-FCC407 UNII 1 Rev. 3) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408) 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 MET Report: EMC85243-FCC407 UNII 1 © 2015, MET Laboratories, Inc. Page i of viii Electromagnetic Compatibility Criteria Class II Permissive Change Test Report for the ARRIS Group, Inc. Model DG1660/DG1670 Tested under The FCC Certification Rules contained in Title 47 of the CFR, Part 15.407 for Intentional Radiators MET Report: EMC85688-FCC407 UNII 1 Rev. 3 July 14, 2015 Prepared For: ARRIS Group, Inc. 3871 Lakefield Drive, Suite 300 Suwanee, Georgia 30024 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave. Baltimore, MD 21230 Electromagnetic Compatibility ARRIS Group, Inc. Introduction DG1660/DG1670 CFR Title 47, Part 15.407 Subpart E (UNII 1) MET Report: EMC85688-FCC407 UNII 1 Rev. 3 © 2015, MET Laboratoires, Inc. Page ii of viii Electromagnetic Compatibility Criteria Class II Permissive Change Test Report for the ARRIS Group, Inc. Model DG1660/DG1670 Tested under The FCC Certification Rules contained in Title 47 of the CFR, Part 15.407 for Intentional Radiators Benjamin Taylor, Project Engineer Amy Graziano Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Parts 15B, 15.407, of the FCC Rules under normal use and maintenance. Asad Bajwa, Director, Electromagnetic Compatibility Lab Electromagnetic Compatibility ARRIS Group, Inc. Introduction DG1660/DG1670 CFR Title 47, Part 15.407 Subpart E (UNII 1) MET Report: EMC85688-FCC407 UNII 1 Rev. 3 © 2015, MET Laboratoires, Inc. Page iii of viii Report Status Sheet Revision Report Date Reason for Revision  May 29, 2015 Initial Issue. 1 June 18, 2015 Editorial corrections. 2 July 7, 2015 Updated to reflect new power measurement values. 3 July 14, 2015 Updated to reflect revised MPE calculation. Electromagnetic Compatibility ARRIS Group, Inc. Table of Contents DG1660/DG1670 CFR Title 47, Part 15.407 Subpart E (UNII 1) MET Report: EMC85688-FCC407 UNII 1 Rev. 3 © 2015, MET Laboratoires, Inc. Page iv of viii Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview .............................................................................................................................................................4 B. References ...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample .................................................................................................................................5 E. Equipment Configuration ....................................................................................................................................5 F. Support Equipment .............................................................................................................................................5 G. Modifications ...............................................................................…

Text truncated - open the document above for the full version.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ● BALTIMORE, MARYLAND 21230-3432 ● PHONE (410) 354-3300 ● FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408) 748-3585 ● FAX (510) 489-6372 13501 MCCALLEN PASS ● AUSTIN, TX 78753 ● PHONE (512) 287-2500 ● FAX (512) 287-2513 The Nation’s First Licensed Nationally Recognized Testing Laboratory July 14, 2015 ARRIS Group, Inc. 3871 Lakefield Drive, Suite 300 Suwanee, Georgia 30024 Dear Tony Figueiredo, Enclosed is the EMC Wireless test report for Class II Permissive Change compliance testing of the ARRIS Group, Inc., DG1660/DG1670 as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Title 47 of the CFR, Part 15.407, Subpart E (UNII 3) for Intentional Radiators. Thank you for using the services of MET Laboratories,…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Antonio A Figueiredo(Manager -Regulatory/Compliance)
[email protected]678-473-5067Fax: 678-473-8712

Technical Contact

ARRIS Group, Inc.Antonio A. Figueiredo
[email protected]678-473-5067

3871 Lakefield Drive · Suwanee, Georgia · United States

Test Firm

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INCGreg Kovolenko
[email protected]4108444071Fax: 4103543313

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz180.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is the combined maximum conducted output power. This device is equipped with specific antennas operating in a 3x3 MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except as described in this filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has a 20 MHz and 40 MHz bandwidth modes.

Other Applications from ARRIS

Cable Modem - FCC ID UIDG54 - ARRIS
UIDG54

Cable Modem

Jul 02, 2023

Equipment Class

6ID - 15E 6 GHz Low Power Indoor Access Point
11ax Tri-band Extender - FCC ID UIDX6 - ARRIS
UIDX6

11ax Tri-band Extender

May 02, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
XGS-PON GATEWAY - FCC ID UIDNVG678XY - ARRIS
UIDNVG678XY

XGS-PON GATEWAY

Mar 22, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Wireless Router - FCC ID UIDW61 - ARRIS
UIDW61

Wireless Router

Aug 15, 2022

Equipment Class

6PP - 15E 6 GHz Subordinate Indoor Device
Wireless Router - FCC ID UIDW6 - ARRIS
UIDW6

Wireless Router

Jun 10, 2022

Equipment Class

6ID - 15E 6 GHz Low Power Indoor Access Point