Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 08, 2007
Application Purpose
Original Equipment
Date of Application
Mar 08, 2007
Equipment Note
Remote controller
Frequency Range
433.92000000 - 433.92000000
Company
Babaco Alarm Systems
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER MANUAL Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Feature: Specification: Power: DC 3V CR2032 Battery Frequency: 433.92MHz Control Distance: 30m Operation: The remote has a battery in when you get the products and keep standby mode, when you push the button (refer the figure), the led will turn on and the remote transmitting signal to receiver. The transmitting will stop right now when you release the switch. If the Led is off when you push the button, please change a new battery as below: 1, release the screw on back 2, Open the plastic Cover 3, Take out the old battery, insert new battery 4, Covered and fill the screw 5, normal operation If the product faults, please contact with dealer.

Cover Letter(s)

Confidentiality Request Date: 2007/0 2/10 Federal Communications Commission Authorization and Evaluation Division FCC ID: UNIBBC-LBTX02 Pursuant to sections 0.457 and 0.459 of the Commision’s Rules, the Applicant hereby requests confidential treatment of information accomparting with this Application as outlined below: 1 – Block Diagram 2 – Circuit Diagram 3 – Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that persuant to Rules 0.457, discolsure of this Application and all accompanying documentation will not be made before the date of the grant of this application. Sincerely, Applicant’s company name: BABACO ALARM SYSTEMS Applicant’s company address: 110W Commercial Ave,Moonachine,NJ07074 Signature: Name: Greg Haber

External Photos

APPENDIX III External Photos EUT– Front View EUT – Rear View

ID Label/Location Info

APPENDIX I FCC ID Label

ID Label/Location Info

APPENDIX II FCC ID Label Location FCC ID Label Location

Internal Photos

APPENDIX IV Internal Photos EUT – Uncovered View-1 EUT –PCB View (1) EUT –PCB View (2)

Test Report

Note: This test report is specially limited to the above client company and product model. It may not be duplicated without prior written consent of BEST Test Service (Shenzhen) Co., Ltd. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government FCC PART 15.231 EMI MEASUREMENT AND TEST REPORT FOR BABACO ALARM SYSTEMS 110W Commercial Ave, Moonachine, NJ07074 FCC ID: UNIBBC-LBTX02 Product Name: REMOTE Model No: TX083 Sample Received Date: Feb 09 2007 Test Performed Date : Feb 12-16, 2007 Test Engineer: Paul Tan Reviewed By: Chris Zeng Prepared By: BEST Test Service (Shenzhen) Co., Ltd Flat 11E, Xinhaofang Building, 11018, Shennan Road, Nanshan District, Shenzhen, 518057, China Tel: +86-755-86182350 Fax: +86-755-86182353 BABACO ALARM SYSTEMS Model: TX083 Report # BTR07021201-1 Page 2 of 13 FCC ID: UNIBBC-LBTX02 TABLE OF CONTENTS GENERAL INFORMATION.......................................................................................................................................3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...............................................................................3 OBJECTIVE...................................................................................................................................................................3 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................3 TEST METHODOLOGY..................................................................................................................................................3 TEST FACILITY.............................................................................................................................................................3 SYSTEM TEST CONFIGURATION ..........................................................................................................................4 JUSTIFICATION.............................................................................................................................................................4 EUT EXERCISE SOFTWARE..........................................................................................................................................4 SPECIAL ACCESSORIES.................................................................................................................................................4 BLOCK DIAGRAM.........................................................................................................................................................4 EQUIPMENT MODIFICATIONS.......................................................................................................................................4 TEST SETUP BLOCK DIAGRAM.....................................................................................................................................4 SUMMARY OF TEST RESULTS...............................................................................................................................5 §15.203 – ANTENNA REQUIREMENTS ...................................................................................................................6 §15.207 – CONDUCTED LIMITS ...............................................................................................................................7 §15.231(A) –DEACTIVATE .........................................................................................................................................8 §15.209(A) AND §15.231(B) - RADIATED EMISSION ............................................................................................9 STANDARD APPLICABLE..............................................................................................................................................9 MEASUREMENT UNCERTAINTY..................................................................................................................................10 EUT SETUP................................................................................................................................................................10 TEST APPARATUS.......................................................................................................................................................11 TEST PROCEDURE......................................................................................................................................................11 CORRECTED AMPLITUDE & MARGIN CALCULATION.................................................................................................11 SUMMARY OF TEST RESULTS.....................................................................................................................................11 §15.231(C) – EMISSION BANDWIDTH ..................................................................................................................13 STANDARD APPLICABLE............................................................................................................................................13 TEST APPARATUS.......................................................................................................................................................13 BABACO ALARM SYSTEMS Model: TX083 Report # BTR07021201-1 Page 3 of 13 FCC ID: UNIBBC-LBTX02 GENERAL INFORMATION 1.1 Product Description for Equipment Under Test (EUT) The BABACO ALARM SYSTEMS.’s Model: TX083or the “EUT” as referred to in this report is a REMOTE which measures approximately 30mmL x 59mmW x9mmH, powered by DC 3V CR2032 battery, operation frequency is 433.92MHz *The test data gathered are from production sample serial number 0701146 provided by the manufacturer. Objective This document is a test report based on the Electromagnetic Interference (EMI) tests performed on the EUT. The EMI measurements were performed according to …

Text truncated - open the document above for the full version.

Test Setup Photos

APPENDIX V Test Setup Photos Test Setup – Front View Test Setup – Nearby View

Contact Information

Applicant

Greg Haber(Manager)
[email protected]800-283-2222Fax: 201-804-8717

Test Firm

Shenzhen Huatongwei International Insp. Co., LtdMoffy Yu
[email protected]86-755-26748078Fax: 86-755-26748089

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality