Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RF Remote Control User Manual FCC NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1. Press the left key on remote control to execute a βonβ command meanwhile the LED indicator will light up. 2. Press the right key on remote control to execute a βoff β command meanwhile the LED indicator will light up. Replace battery: 1. Open the back cover of remote control with screwdriver, take out the used battery. 2. Install the new battery, make sure of β+β, β-β position in battery chamber. 3. Close the cover of remote control, tighten it with screws.
1 2 34 ABCD 4 3 2 1 D CBA Title Number Revision Size A4 Date: 28-Nov-2006 Sheet of File: E:\kaifa\PCB\LY-T-NEW-V7[2].DDB Drawn By: KEYS ENCODE GENERATOR RF OSCILLATOR OOK MODULATION ANTENNA WITH 433.92MHz SAW
EUTβExternal Photo View 1. EUT- Front View 2. EUT- Back View
Remote Light Transmitter FCC ID LABEL Remote Light Transmitter Model: WZ-Light FCC ID: UTXWZLIGHT This device compliance with part 15 of the FCC rules ,See instruction manual Rating: 12V DC MADE IN CHINA
FCC ID LABEL Location This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The label must not be a stick-on paper. The label on these products must be permanently affixed to the product and readily visible at the time of Purchase and must last the expected lifetime of the equipment not be readily detachable. Proposed Label Location on EUT EUT Bottom View/proposed FCC Mark Location
RF Remote Control Operation Description This is a short distance RF remote control with 433.92MHz, there are two buttons on it. The different command signal are transmitted when pressing the different buttons, at the same time the red LED will light up. The remote control powered by one 12V alkali battery, its standby current is less than 5uA , and operating current is less than 15mA when in operation. When operating remote control, its LED light become weaker and remote distance become short obviously , its time to change used battery with new one. Open the cover of remote control with screwdriver , replace the used battery with the same type battery.
SHENZHEN EMTEK Co., Ltd. REPORT NO:E0610123F FCC ID: UTXWZLIGHT DATE: 12/11/2006 Page 1 of 23 Rev. 00 ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C REQUIREMENT OF Remote Light Transmitter MODEL No.: WZ-Light FCC ID: UTXWZLIGHT REPORT NO: E0610123F ISSUE DATE: December 11, 2006 Prepared for Elgin molded plastic, Inc 909 Grace Street Elgin, IL60120, Chicago Prepared by SHENZHEN EMTEK Co., Ltd. Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China TEL: 86-755-26954280 FAX: 86-755-26954282 SHENZHEN EMTEK Co., Ltd. REPORT NO:E0610123F FCC ID: UTXWZLIGHT DATE: 12/11/2006 Page 2 Rev. 00 VERIFICATION OF COMPLIANCE Applicant: Elgin molded plastic, Inc 909 Grace Street Elgin, IL60120, Chicago Product Description: Remote Light Transmitter Model Number: WZ-Light Serial Number: N/A File Number: E0610123F Date of Test: December 04, 2006 to December 10, 2006 We hereby certify that: The above equipment was tested by SHENZHEN EMTEK Co., Ltd. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 (2003) and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC 15 Paragraph 15.205, Paragraph 15.209, Paragraph 15.231,Paragraph 15.31, Paragraph 15.33, Paragraph 15.35. The test results of this report relate only to the tested sample identified in this report. Approved By David Lee/ Q.A. Manager SHENZHEN EMTEK Co., Ltd. SHENZHEN EMTEK Co., Ltd. REPORT NO:E0610123F FCC ID: UTXWZLIGHT DATE: 12/11/2006 Page 3 Rev. 00 Table of Contents 1. GENERAL INFORMATION ................................................................................................. 5 1.1 P RODUCT D ESCRIPTION ........................................................................................................................... 5 1.2 R ELATED S UBMITTAL ( S ) / G RANT ( S ) ..................................................................................................... 5 1.3 T EST M ETHODOLOGY .............................................................................................................................. 5 1.4 S PECIAL A CCESSORIES ............................................................................................................................ 5 1.5 E QUIPMENT M ODIFICATIONS .................................................................................................................. 5 1.6 T EST F ACILITY ........................................................................................................................................ 6 2. SYSTEM TEST CONFIGURATION .................................................................................... 7 2.1 EUT C ONFIGURATION ............................................................................................................................. 7 2.2 EUT E XERCISE ........................................................................................................................................ 7 2.3 T EST P ROCEDURE .................................................................................................................................... 7 2.4 L IMITATION ............................................................................................................................................. 8 2.5 C ONFIGURATION OF T ESTED S YSTEM ..................................................................................................... 9 3. SUMMARY OF TEST RESULTS ....................................................................................... 10 4. DESCRIPTION OF TEST MODES .................................................................................... 10 5. CONDUCTED EMISSIONS TEST (NOT APPLICABLE IN THIS REPORT).......... 11 5.1 MEASUREMENT PROCEDURE:................................................................................................................ 11 5.2 T EST SET-UP (B LOCK D IAGRAM OF C ONFIGURATION ) ....................................................................... 11 5.3 M EASUREMENT E QUIPMENT U SED : ...................................................................................................... 11 5.4 MEASUREMENT RESULT:....................................................................................................................... 11 5.5 C ONDUCTED M EASUREMENT P HOTOS :...................................................................................................... 11 6. RADIATED EMISSION TEST ............................................................................................ 12 6.1 M EASUREMENT P ROCEDURE ................................................................................................................. 12 6.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ....................................................................... 13 6.3 M EASUREMENT E QUIPMENT U SED : ...................................................................................................... 13 6.4 M EASUREMENT R ESULT ........................................................................................................................ 14 7. DEACTIVATION TESTING ............................................................................................... 16 7.1 REQUIREMENT....................................................................................................................................... 16 7.2 T EST SET-UP ......................................................................................................................................... 16 7.3 M EASUREMENT E QUIPMENT U SED : ...................................................................................................... 16 7.4 TEST PROCEDURE......................................................................................β¦
Text truncated - open the document above for the full version.
SHENZHEN EMTEK Co., Ltd. REPORT NO:E0610123F FCC ID: UTXWZLIGHT DATE: 12/11/2006 Page 1 of 23 Rev. 00 ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C REQUIREMENT OF Remote Light Transmitter MODEL No.: WZ-Light FCC ID: UTXWZLIGHT REPORT NO: E0610123F ISSUE DATE: December 11, 2006 Prepared for Elgin molded plastic, Inc 909 Grace Street Elgin, IL60120, Chicago Prepared by SHENZHEN EMTEK Co., Ltd. Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China TEL: 86-755-26954280 FAX: 86-755-26954282 SHENZHEN EMTEK Co., Ltd. REPORT NO:E0610123F FCC ID: UTXWZLIGHT DATE: 12/11/2006 Page 2 Rev. 00 VERIFICATION OF COMPLIANCE Applicant: Elgin molded plastic, Inc 909 Grace Street Elgin, IL60120, Chicago Product Description: Remote Light Transmitter Model Number: WZ-Light Serial Number: N/A File Number: E0610123F Date of Test: December 04, 2006 to December 10, 2006 We hereby certify that: The above equipment was tested by SHENZHEN EMTEK Co., Ltd. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 (2003) and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC 15 Paragraph 15.205, Paragraph 15.209, Paragraph 15.231,Paragraph 15.31, Paragraph 15.33, Paragraph 15.35. The test results of this report relate only to the tested sample identified in this report. Approved By David Lee/ Q.A. Manager SHENZHEN EMTEK Co., Ltd. SHENZHEN EMTEK Co., Ltd. REPORT NO:E0610123F FCC ID: UTXWZLIGHT DATE: 12/11/2006 Page 3 Rev. 00 Table of Contents 1. GENERAL INFORMATION ................................................................................................. 5 1.1 P RODUCT D ESCRIPTION ........................................................................................................................... 5 1.2 R ELATED S UBMITTAL ( S ) / G RANT ( S ) ..................................................................................................... 5 1.3 T EST M ETHODOLOGY .............................................................................................................................. 5 1.4 S PECIAL A CCESSORIES ............................................................................................................................ 5 1.5 E QUIPMENT M ODIFICATIONS .................................................................................................................. 5 1.6 T EST F ACILITY ........................................................................................................................................ 6 2. SYSTEM TEST CONFIGURATION .................................................................................... 7 2.1 EUT C ONFIGURATION ............................................................................................................................. 7 2.2 EUT E XERCISE ........................................................................................................................................ 7 2.3 T EST P ROCEDURE .................................................................................................................................... 7 2.4 L IMITATION ............................................................................................................................................. 8 2.5 C ONFIGURATION OF T ESTED S YSTEM ..................................................................................................... 9 3. SUMMARY OF TEST RESULTS ....................................................................................... 10 4. DESCRIPTION OF TEST MODES .................................................................................... 10 5. CONDUCTED EMISSIONS TEST (NOT APPLICABLE IN THIS REPORT).......... 11 5.1 MEASUREMENT PROCEDURE:................................................................................................................ 11 5.2 T EST SET-UP (B LOCK D IAGRAM OF C ONFIGURATION ) ....................................................................... 11 5.3 M EASUREMENT E QUIPMENT U SED : ...................................................................................................... 11 5.4 MEASUREMENT RESULT:....................................................................................................................... 11 5.5 C ONDUCTED M EASUREMENT P HOTOS :...................................................................................................... 11 6. RADIATED EMISSION TEST ............................................................................................ 12 6.1 M EASUREMENT P ROCEDURE ................................................................................................................. 12 6.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ....................................................................... 13 6.3 M EASUREMENT E QUIPMENT U SED : ...................................................................................................... 13 6.4 M EASUREMENT R ESULT ........................................................................................................................ 14 7. DEACTIVATION TESTING ............................................................................................... 16 7.1 REQUIREMENT....................................................................................................................................... 16 7.2 T EST SET-UP ......................................................................................................................................... 16 7.3 M EASUREMENT E QUIPMENT U SED : ...................................................................................................... 16 7.4 TEST PROCEDURE......................................................................................β¦
Text truncated - open the document above for the full version.
Test Setup Photo
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |