Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 1 | 90 | 446.00625 MHz - 464.375 MHz | 1.968 W | 11K0F3E | 1.3000000000
ppm |
Grant NotesOutput Power listed is rated conducted.
Maximum conducted output power is 1.97 Watts as allowed per 47 CFR, 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn operating configuration is limited to the specific belt-clip supplied for use with this product that provides at least 1.5 cm separation between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance.
The highest reported SAR values for this UHF Transmitter are � Held to Face: 1.98 W/kg; Body-worn: 5.57 W/kg accounting for a 50% duty cycle.