Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Aug 01, 2007
Application Purpose
Original Equipment
Date of Application
Aug 01, 2007
Equipment Note
Tag Reader Module
Frequency Range
13.56000000 - 13.56000000
Company
BTG Mütek Gmbh
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DOSINGMODULE Page 1 BTG Instruments GmbH Arzbergerstraße 10, D-8211 Herrsching, Phone 49 (0)8152 9312 0, Fax +49 (0)8152 9312 900, Email: [email protected], www.btg.com BTG Instruments GmbH MANUAL DOSINGMODULE DOSINGMODULE Page 2 BTG Instruments GmbH Arzbergerstraße 10, D-8211 Herrsching, Phone 49 (0)8152 9312 0, Fax +49 (0)8152 9312 900, Email: [email protected], www.btg.com BTG Instruments GmbH Arzbergerstr. 10 D-82211 Herrsching Emai: [email protected] www.btg.com Copyright © 2007 by BTG Instruments GmbH. All rights reserved. All information in the following document is protected by copyright law. No part of this document may be reproduced without the written consent of BTG Instruments GmbH. BTG Instruments GmbH reserves the right to make any changes of specification and other information in this document without further notice. Please note During the compilation of this technical documentation, great care has been taken to ensure the accuracy of the information contained in it. However, despite our constant effort to ensure the highest degree of accuracy and comprehensiveness possible, the information provided cannot be guaranteed to be absolutely error- free. Trademarks This documentation may contain representations of registered product or service trademarks owned by BTG Instruments GmbH or third parties, as well as references to proprietary know-how protected by copyright laws or other legal provisions. In any case the intellectual property rights remain exclusively with their respective owners. DOSINGMODULE Page 3 BTG Instruments GmbH Arzbergerstraße 10, D-8211 Herrsching, Phone 49 (0)8152 9312 0, Fax +49 (0)8152 9312 900, Email: [email protected], www.btg.com FCC 15.225: IMPORTANT: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment The final product should contain labelling according to FCC requirements. For example: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device contains FCC ID UV6DOSINGMODULE00. This label will be placed on the final product, clearly visible to all persons exposed to the transmitter. DOSINGMODULE Page 4 BTG Instruments GmbH Arzbergerstraße 10, D-8211 Herrsching, Phone 49 (0)8152 9312 0, Fax +49 (0)8152 9312 900, Email: [email protected], www.btg.com General DOSINGMODULE is a RFID module which is designed for installation in BTG devices by BTG Instruments GmbH only. The module is not to be sold as an individual product. DOSINGMODULE Page 5 BTG Instruments GmbH Arzbergerstraße 10, D-8211 Herrsching, Phone 49 (0)8152 9312 0, Fax +49 (0)8152 9312 900, Email: [email protected], www.btg.com DOSINGMODULE / front view DOSINGMODULE Page 6 BTG Instruments GmbH Arzbergerstraße 10, D-8211 Herrsching, Phone 49 (0)8152 9312 0, Fax +49 (0)8152 9312 900, Email: [email protected], www.btg.com DOSINGMODULE / rear view with antenna

Cover Letter(s)

BTG Mütek GmbH Arzbergerstraße 10 82211 Herrsching Germany PHOENIX TEST-LAB GmbH Product Certification Königswinkel 10 D 32825 Blomberg FCC Certification / FCC ID: UV6DOSINGMODULE00 To Whom It May Concern: Please be advised that BTG Mütek GmbH authorizes Senton GmbH to act on our behalf, until otherwise notified, for applications submitted to PHOENIX TEST-LAB GmbH (PTL). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C.862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter.

Cover Letter(s)

EMV-Prüfzentrum EMI/EMC-Testcenter Coordinates: Äussere Frühlingstrasse 45 y D-94315 Straubing Telefon (0 94 21) 55 22-0 Telefax (0 94 21) 55 22-99 [email protected] y http://www.senton.de Senton GmbH y Äussere Frühlingstrasse 45 y D-94315 Straubing PHOENIX TEST-LAB GmbH Koenigswinkel 10 D-32825 Blomberg Germany August 2, 2007 In reference to FCC ID UV6DOSINGMODULE00 Justification for Part 15 Unlicensed Modular Transmitter Approval according to DA 00-1407 1. Own RF Shielding Not complied, but subject to limited modular approval. The Grantee can demonstrate that it will retain control over the final installation of the device, such that compliance of the end product is assured. In such a case, an operating condition on the grant of equipment authorization for the module would state that the module is only approved for use when installed in devices produced by a specific manufacturer, typically the Grantee. 2. Buffered Modulation inputs Complied, no direct modulation input. Modulated signals will be buffered by microcontroller IC2 3. Own power supply regulation Not complied, but subject to limited modular approval. The Grantee can demonstrate that it will retain control over the final installation of the device, such that compliance of the end product is assured. In such a case, an operating condition on the grant of equipment authorization for the module would state that the module is only approved for use when installed in devices produced by a specific manufacturer, typically the Grantee. 4. Antenna requirements Complied, integrated antenna 5. Test in stand-alone configuration Complied, see test report for details. The tested equipment only was mechanical mounted to the plastic housing of the final application, without any electrical connection to the base equipment. The tested equipment was external powered. The open casing only was used as mounting for the tested equipment. 6. Own FCC ID Complied, the exterior label will be "Contains FCC ID UV6DOSINGMODULE00" Subject to limited modular approval 7. The Modular Transmitter must comply with any specific rule and the manufacturer must provide adequate instructions The EUT is compliant with all applicable FCC rules. Detail instructions are given in the user guide. 8. RF Exposure requirements Not applicable since the unit operates under section 15.225 of the FCC rules. The reference guide contains general installation and operation instructions. MPE evaluation not required Johann Roidt Senton GmbH

Cover Letter(s)

Ersteller: U. Rodemeier Revision: 03 Erstelldatum: 03.08.01 Datum: 4.10.2006 Seite 1 von 1 Request for Confidentiality PHOENIX TESTLAB GmbH Date: August 1, 2007 Product Certification Königswinkel 10 D 32825 Blomberg RE: Certification Application FCC ID: UV6DOSINGMODULE00 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: • Schematics • Block Diagram • Technical Description • Parts List The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : Senton GmbH address : Auessere Fruehlingstrasse 45, D-94315 Straubing Signature : Johann Roidt Job Title and Dept. : Technical Director

External Photos

FCC ID UV6DOSINGMODULE00 FCC ID: UV6DOSINGMODULE00 FCC ID: UV6DOSINGMODULE00

ID Label/Location Info

FCC ID UV6DOSINGMODULE00

Internal Photos

FCC ID UV6DOSINGMODULE00 FCC ID: UV6DOSINGMODULE00 FCC ID: UV6DOSINGMODULE00

Test Report

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 1 of 52 Page(s) Straubing, März 29, 2007 T E S T - R E P O R T No. 50531-070020 (Edition 1) for DOSINGMODULE Tag Reader Module Applicant: BTG Mütek GmbH Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205, 15.207, 15.215 and 15.225 Industry Canada Radio Standards Specifications RSS-Gen Issue 1, Section 7.2.2 and RSS-210 Issue 6, Sections 2.2, 2.6, A2.6 (Category I Equipment) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 2 of 52 Page(s) Table of Contents 1 Description of the Equipment Under Test (EUT)......................................................... 3 2 Administrative Data ..................................................................................................... 4 3 Identification of the Test Laboratory............................................................................ 5 4 Summary..................................................................................................................... 6 5 Operation Mode and Configuration of EUT ................................................................. 7 6 Measurement Procedures........................................................................................... 8 6.1 Bandwidth Measurements .................................................................................... 8 6.2 Conducted AC Powerline Emission ...................................................................... 9 6.3 Radiated Emission Measurement 9 kHz to 30 MHz ........................................... 11 6.4 Radiated Emission in Fully or Semi Anechoic Room .......................................... 13 6.5 Radiated Emission at Open Field Test Site ........................................................ 15 6.6 Carrier Frequency Stability ................................................................................. 17 7 Photographs Taken During Testing .......................................................................... 19 8 Test Results .............................................................................................................. 25 8.1 Occupied Bandwidth ........................................................................................... 27 8.2 Bandwidth of the Emission ................................................................................. 31 8.3 Designation of Emissions ................................................................................... 33 8.4 Conducted Powerline Emission Measurement 150 kHz to 30 MHz................... 34 8.5 Spectrum Mask................................................................................................... 38 8.6 Radiated Emission Measurement 9 kHz to 30 MHz .......................................... 40 8.7 Radiated Emission Measurement 30 MHz to 1 GHz ......................................... 43 8.8 Carrier Frequency Stability ................................................................................. 45 8.9 Exposure of Humans to RF Fields ...................................................................... 48 9 Referenced Regulations............................................................................................ 50 10 Revision History ........................................................................................................ 51 11 Charts taken during testing ....................................................................................... 52 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 3 of 52 Page(s) 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : DOSINGMODULE Parts 2 : Serial number(s): 110-Po14-0010 Manufacturer: BTG Mütek GmbH Type of equipment: Tag Reader Module Version: FCC ID: UV6 Additional parts/accessories: Technical data of EUT Application frequency range: 13.11 MHz - 14.01 MHz Frequency range: 13.56 MHz Operating frequency: 13.56 MHz Type of modulation: 10K0A1D Pulse train: --- Pulse width: --- Number of RF-channels: 1 Channel spacing: --- Designation of emissions 3 : ASK Type of antenna: Loop on printed board Size/length of antenna: 40 x 58 mm Connection of antenna: detachable not detachable Type of power supply: DC supply Specifications for power supply: nominal voltage: 5.00 V minimum voltage: 4.25 V maximum voltage: 5.75 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 4 of 52 Page(s) 2 Administrative Data Application details Applicant (full address): BTG Mütek GmbH Arzbergerstraße 10 82211 Herrsching Germany Receipt of EUT: 14 March 2007 Date(s) of test: March 2007 Note(s): Report details Report number: 50531-070020 Edition: 1 Issue date: März 29, 2007 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 5 of 52 Page(s) 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory accreditation: DAR-Registration No. DAT-P-171/94-02 FCC test site registration number 90926 Industry Canada test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 6 of 52 Page(s) 4 Summary Summary of test results The tested sample complies with the requirements set forth in the Code of Federal Regulations CFR 47, Part 15, Sections 15.205, 15.207, 15.215 and 15.225 of the Federal Communication Commission (FCC) and the Radio Standards Specific…

Text truncated - open the document above for the full version.

Test Setup Photos

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 20 of 52 Page(s) Test setup for conducted AC powerline emission measurement Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 21 of 52 Page(s) Test setup for radiated emission measurement 9 kHz – 30 MHz Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 22 of 52 Page(s) Test setup for radiated emission measurement (fully anechoic room) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 23 of 52 Page(s) Test setup for radiated emission measurement (fully anechoic room) - continued - Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50531-070020 (Edition 1) Page 24 of 52 Page(s) Test setup for radiated emission measurement (open field test site)

Contact Information

Applicant

Markus Mornhinweg(Dipl. Ing.)
[email protected]+49 81529312Fax: +49 81529312912

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115C13.56 MHz - 13.56 MHz-0.0100000000 %
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
Limited Modular Approval. Approval of this transmitting device with the antenna shown in this filing is only allowed to the manufacturer's integration into host products. Compliance of this device in any final configuration is the responsibility of the Grantee. End-users may not be provided with the module integration instructions.