Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Custom Name: Huang yin Antenna Peak Gain:-1.24 dBi
Compliance Certification Services (Kunshan) Inc. Report No.: KS070119A01-RP FCC ID:UYV-KINGSOUNDIND Date of Issue: March 21, 2007 EXTERNAL PHOTOGRAPHS OF EUT Compliance Certification Services (Kunshan) Inc. Report No.: KS070119A01-RP FCC ID:UYV-KINGSOUNDIND Date of Issue: March 21, 2007
LABEL LOCATION
Compliance Certification Services (Kunshan) Inc. Report No.: KS070119A01-RP FCC ID:UYV-KINGSOUNDIND Date of Issue: March 21, 2007 INTERNAL PHOTOGRAPHS OF EUT Compliance Certification Services (Kunshan) Inc. Report No.: KS070119A01-RP FCC ID:UYV-KINGSOUNDIND Date of Issue: March 21, 2007 Antenna Connected Point
Compliance Certification Services Inc. Report No.: KS070119A01-RP FCC ID:UYV-KINGSOUNDIND Date of Issue: April 25, 2007 Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 Total Page: 25 Rev. 00 FCC 47 CFR PART 15 SUBPART C TEST REPORT For Switch Model: KS-080 Trade Name: HandySwitch Prepared for KING SOUND ENTERPRISE CO.οΌLT D NO. 93 WU SONG SOUTH ROAD LUZHI TOWN WU ZHONG DISTRICT SU ZHOU CITY JIANG SU PROVINCE CHINA Issued by COMPLIANCE CERTIFICATION SERVICES (KUNSHAN) INC. 10#Weiye Rd, Innovation Park Eco. & Tec. Development Zone Kunshan city JiangSu, (215300) CHINA TEL: 86-512-57355888 FAX: 86-512-57370818 Lab. Code: 200581-0 Compliance Certification Services Inc. Report No.: KS070119A01-RP FCC ID:UYV-KINGSOUNDIND Date of Issue: April 25, 2007 Page 2 Rev. 00 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION............................................................................................. 3 2. COMPLIANCE CERTIFICATION SERVICES INC. ................................................ 4 3. TEST METHODOLOGY ............................................................................................................. 5 EUT CONFIGURATION...............................................................................................................................5 EUT EXERCISE...................................................................................................................................... 5 GENERAL TEST PROCEDURES...................................................................................................................5 MODIFICATION 5 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS...............................................................6 DESCRIPTION OF TEST MODES..................................................................................................................6 4. INSTRUMENT CALIBRATION................................................................................................. 7 5. FACILITIES AND ACCREDITATIONS ................................................................................... 8 FACILITIES...............................................................................................................................................8 EQUIPMENT.......................................................................................................................................... 8 LABORATORY ACCREDITATIONS AND LISTING........................................................................................8 TABLE OF ACCREDITATIONS AND LISTINGS.............................................................................................9 6. SETUP OF EQUIPMENT UNDER TEST ................................................................................ 10 SETUP CONFIGURATION OF EUT.............................................................................................................10 SUPPORT EQUIPMENT .....................................................................................................................10 7. FCC PART 15.231EQUIREMENTS ......................................................................................... 11 20DB BANDWIDTH.................................................................................................................................11 LIMIT OF TRANSMISSION TIME...............................................................................................................13 DUTY CYCLE 15 POWERLINE CONDUCTED EMISSIONS.....................................................................................................23 APPENDIX 1 PHOTOGRAPHS OF TEST SETUP ....................................................................... 25 Compliance Certification Services Inc. Report No.: KS070119A01-RP FCC ID:UYV-KINGSOUNDIND Date of Issue: April 25, 2007 Page 4 Rev. 00 2. COMPLIANCE CERTIFICATION SERVICES INC. EUT DESCRIPTION Product Switch Trade Name HandySwitch Model Number KS-080 Model Discrepancy All the above models are identical except the model designation. Power Supply Powered by Alkaline battery(Rating:12Vdc) Frequency Range 315 MHz Modulation Technique ASK Antenna Specification PCB Antenna / Gain: -1.24 dBi Remark: This submittal(s) (test report) is intended for FCC ID: UYV-KINGSOUNDIND filing to comply with Section 15.207, 15.209 and 15.231 of the FCC Part 15, Subpart C Rules. Compliance Certification Services Inc. Report No.: KS070119A01-RP FCC ID:UYV-KINGSOUNDIND Date of Issue: April 25, 2007 Page 5 Rev. 00 3. TEST METHODOLOGY The tests documented in this report were performed in accordance with ANSI C63.4 and FCC CFR 47 2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055, 2.1057, 15.207, 15.209 and 15.231. EUT CONFIGURATION The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. EUT EXERCISE The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the measurements. According to its specifications, the EUT must comply with the requirements of the Section 15.231under the FCC Rules Part 15 Subpart C. GENERAL TEST PROCEDURES Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in Section 13.1.4.1 of ANSI C63.4 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak and average detector modes. Radiated Emissions The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiviβ¦
Text truncated - open the document above for the full version.
Compliance Certification Services (Kunshan) Inc. Report No.: KS070119A01-RP FCC ID:UYV-KINGSOUNDIND Date of Issue: March 21, 2007 TEST SETUP PHOTOGRAPHS OF EUT RADIATED EMISSION TEST Front of view Back of view
No. 10 Weiye Rd., Innovation Park Β· KunShan, JuangSu Β· China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |