FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhan Xiang Technology (Hui Zhou) CO., LTD/
  3. V26PX-T70331

V26PX-T70331Flat Panel Bracket R/C Transmitter

Zhan Xiang Technology (Hui Zhou) CO., LTD
Flat Panel Bracket R/C Transmitter - FCC ID V26PX-T70331 - Zhan Xiang Technology (Hui Zhou) CO., LTD
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 17, 2008
Application Purpose
Original Equipment
Date of Application
Mar 17, 2008
Equipment Note
Flat Panel Bracket R/C Transmitter
Frequency Range
433.92000000 - 433.92000000
Company
Zhan Xiang Technology (Hui Zhou) CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER GUIDE Model:ZX-A04A Length:706 mm Width:232 mm Height:1042 mm 1.Specification 1-1.Dimensions 1-2.Installation Parts: Remote Sensor Pencil Cross screwdriver Wrench Hammer Pecussion borer 11MM 14MM 1-3.Assembly tool(Not included): 70 m m 6 3 2 2 m m 1 0 4 2 m m 2pcs 2pcs 2pcs 2pcs 5 2pcs Pad 3 4 2 1 Do not touch or push the product by hand or other object when it is working . Check carefully to make sure every parts are fastened tightly before use. X , 4. Temperature and humility condition: -20°C ~ +50°C , 80%HR 3-5.Maintenance Do not use corrosive agent or alcohol or chemical cloth to clean! 1.Do not disassemble the product to repair by yourself . Warranty for electricity is void after disassembled! 2.After you installed the apparatus,please check the exp- ansion screws and all fastening devices every 3months, and please do not use it and contact the local dealer if it gets loose,rusty or lost. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference,and (2) this device must accept any interference received,including interference that may cause undesired operation. 1.Do not disassemble the product to repair by yourself . Warranty for electricity is void after disassembled 2.After you installed the apparatus,please check the exp- ansionscrews and allfastening devices every 3months, and please do not use it and contactthelocal dealer if it gets loose,rusty or lost. ! This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference,and (2) this device must accept any interference received,including interference that may cause undesired operation. Warning:Warning: Http://www.xyz888.com.cn Mail : [email protected] M5/M6/M8(mm) Round head screw M5*23/M6*25/M8*30 (mm) Sink head screw M5*25/M6*30/M8*35 (mm) 16*6.2*T1.5/ 16*8.4*T1.6(mm) Washer Tab M5/M6/M8(mm) Expansion screw 6 8pcs Round head screw Remote sensor 7 5pcs 8 1pcs M8*70mm M6*18mm 3.Installation Instruction 3-1.Installation method: 1.Make the mark at the place of ceiling that you want to mount the TV.Use percussion borer to drill 8 holes on the mark,at Φ10mm and 70 depth .Take out 8 pcs 6 expansion screws from the fitting bag,insert them throngh the holes of cart into the hole of ceiling by hammer and fasten them by wrench.(see the diagram) Note:After fasten the cart,connect power,press” lower”key on the remote sensor to extend the cart and take away silicon rubber cushion.Do not press”raise” key before take away the silicon rubber,or the inside parts will be damaged. After fasten the cart, please take away the rubber cushion. Correct installation is extremely essential and falls outside the scope of responsibility of manufacturer,Theuser must pay attention to the weight of TV and TV mount,and only solid wall can support the weight.Please complied with the installation instruction of LCD/PDP to install them. Correct installation is extremely essential and falls outside the scope of responsibility of manufacturer,Theusermust pay attention to the weight of TV and TV mount,and only solid wall can support the weight.Please complied with theinstallation instruction of LCD/PDP to install them. 3-4.NOTICE: Do not connect before fasten the product. Make sure wire and plug are good before connecting. X X 2-2.Motor 2.Electric Specification III.Caution: 3-3.Technical Paramters: Warning:This ceiling mount’s load-bearing weight must be at the range of the indicated max load-bearing weight,Use with heavier than the maximum weights indicated may result in instability causing possible injury! Warning:This ceiling mount’s load-bearing weight must be at the range of the indicated max load-bearing weight,Use with heavier than the maximum weights indicated may result in instability causing possible injury! If any remote control of our product was lost or damaged , you canbuy a new remote control with the same frequency which produce by our company and do following operation: 1. Memory cleaning: press coding key about 10 seconds ,the memory will cleaned after the indicator closed.(The memor is the coding memory of the previous remote control). 2. Use new remote control:press any key of remote control and the coding key1-2seconds at the same time ,loosen remote control firstly ,then loosen the coding key ,finally , you can operate the product with new remote control . (Coding key , Indicator,please see diagram). Item Rated Voltage Current (No load) Current (Rated load) Operation temperature DN3435-3825E DC24V ≦0.7A ≦1.8A -20°C~50°C DN3435-3046E DC24V ≦0.5A ≦1.5A -20°C~50°C Motor PR545AG-16190-RB35C-1000 DC24V ≦0.3A ≦0.5A -20°C~50°C mm m m Φ Notice: Screw the nut into the expansion bushing about 1mm before fix it to the wall (see below diagram) 6 40 2-1.Input Voltage/Current/Frequency: 100-240VAC,< 1.2A,50/60Hz Output Current: DC24V ,3A II.Operation instruction 1.Aim the LED indicator on remote sensor at TV. The remote range is 3-10m. 2.When you press one of the function key on remote sensor straightly(raise,lower,left,right,up,down),the mount will move to the direction you expected.Loosening,the mount will stop. 3.Insert one 23A,12Vbattery in the remote sensor. If the battery ran out,please open the back cover of the sensor and put in the new one. 2.Take out the power plyg from carton.Insert one end to TV cart and other end to power supply. 3. Connect power and press”Down”key on the remote sensor to let the cart pitch to horizontal position.Insert square tube into conjunctive bracket and fasten them by round head screw and M6*15mm half round head screw.Hang TV bracket on square tube and fasten by round head screw.(see the diagram) 7 7 Note: Please fasten the power plug or placed it to appropriate place B.Remote sensor: (Horizontal position) 7.V.p.:one push to extend cart to the programmed operating position automaticall(vertical position0)。 8.H.P.:one push to back …

Text truncated - open the document above for the full version.

External Photos

Page 6 Zhan Xiang Technology (Hui Zhou) CO., LTDFlat Panel TV Bracket FCC ID:V26PX-T70331 Photographs Figure 1 General Appearance Figure 2 General Appearance Label Location

ID Label/Location Info

Page 6 Zhan Xiang Technology (Hui Zhou) CO., LTDFlat Panel TV Bracket FCC ID:V26PX-T70331 Photographs Figure 1 General Appearance Figure 2 General Appearance Label Location

Internal Photos

Page 7 Zhan Xiang Technology (Hui Zhou) CO., LTDFlat Panel TV Bracket FCC ID:V26PX-T70331 Figure 3 Inside of the EUT Figure 4 Inside of the EUT Page 8 Zhan Xiang Technology (Hui Zhou) CO., LTDFlat Panel TV Bracket FCC ID:V26PX-T70331 Figure 5 Inside of the EUT

Test Report

FCC ID:V26PX-T70331 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F08111 APPLICATION FOR CERTIFICATION On Behalf of Zhan Xiang Technology (Hui Zhou) CO., LTD Flat Panel TV Bracket Model Number: PX-T70331 Prepared for : Zhan Xiang Technology (Hui Zhou) CO., LTD Xianiao Village, Longqiao Road, Longxi Town, Boluo Country, Huizhou City Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park, Nantou, Shenzhen, Guangdong, China Tel: (0755) 26639496 Report Number : ACS-F08111 Date of Test : Jan.21~23, 2008 Date of Report : Mar.05, 2008 FCC ID:V26PX-T70331 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F08111 TABLE OF CONTENTS Description Page Test Report Declaration 1. SUMMARY OF STANDARDS AND RESULTS .................................................................. 1-1 1.1. Description of Standards and Results.............................................................................................1-1 2. GENERAL INFORMATION .................................................................................................. 2-1 2.1. Description of Device (EUT) .........................................................................................................2-1 2.2. Test Facility....................................................................................................................................2-2 2.3. Measurement Uncertainty ..............................................................................................................2-2 3. POWER LINE CONDUCTED EMISSION TEST................................................................ 3-1 4. RADIATED EMISSION TEST ............................................................................................... 4-1 4.1. Test Equipment ..............................................................................................................................4-1 4.2. Block Diagram of Test Setup .........................................................................................................4-1 4.3. Radiated Emission Limit (Standard: FCC Part 15) ........................................................................4-2 4.4. EUT Configuration on Test............................................................................................................4-2 4.5. Operating Condition of EUT..........................................................................................................4-3 4.6. Test Procedure................................................................................................................................4-3 4.7. Radiated Emission Test Results .....................................................................................................4-3 5. STOP TRANSMITTING TIME TEST .................................................................................. 5-1 5.1. Test Equipment ..............................................................................................................................5-1 5.2. Test Information .............................................................................................................................5-1 5.3. Test Results ....................................................................................................................................5-1 6. 20 DB BANDWITH TEST ....................................................................................................... 6-1 6.1. Test Equipment ..............................................................................................................................6-1 6.2. Test Information .............................................................................................................................6-1 6.3. Test Results ....................................................................................................................................6-1 7. PULSE DESENSITIZATION CORRECTION FACTOR ................................................... 7-1 8. DEVIATION TO TEST SPECIFICATIONS ........................................................................ 8-1 9. PHOTOGRAPH........................................................................................................................ 9-1 9.1. Photos of Radiated Emission Test (In Anechoic Chamber) ...........................................................9-1 FCC ID:V26PX-T70331 Page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F08111 1-1 1. SUMMARY OF STANDARDS AND RESULTS 1.1. Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below. EMISSION Description of Test Item Standard Results Radiated Emission Test FCC Part 15C: 15.231 ANSI C63.4: 2003 PASS Stop Transmitting Time Test FCC Part 15C: 15.231 PASS 20 dB Bandwidth Test FCC Part 15C: 15.231 PASS FCC ID:V26PX-T70331 Page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F08111 2-1 2. GENERAL INFORMATION 2.1. Description of Device (EUT) Description : Flat Panel TV Bracket Model Number : PX-T70331 Operation frequency : 433.92MHz Modulation : ASK Applicant : Zhan Xiang Technology (Hui Zhou) CO., LTD Xianiao Village, Longqiao Road, Longxi Town, Boluo Country, Huizhou City Manufacturer : Zhan Xiang Technology (Hui Zhou) CO., LTD Xianiao Village, Longqiao Road, Longxi Town, Boluo Country, Huizhou City Date of Test : Jan.21~33, 2008 Date of Receipt : Jan.15, 2008 Sample Type : Prototype production FCC ID:V26PX-T70331 Page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F08111 2-2 2.2. Test Facility Site Description Name of Firm : Audix Technology (Shenzhen) Co., Ltd. No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park,Nantou, Shenzhen, Guangdong, China 3m Anechoic Chamber : Jun. 13, 2006 File on Federal Communication Commission Registration Number: 90454 3m & 10m Anechoic Chamber : Jan. 31, 2007 File on Federal Communication Commission Registration Number: 794232 EMC Lab. : Accred…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID:V26PX-T70331 Page 9-1 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F08111 9. PHOTOGRAPH 9.1. Photos of Radiated Emission Test (In Anechoic Chamber) 30-1000MHz FCC ID:V26PX-T70331 Page 9-2 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F08111 Above 1000MHz

Contact Information

Applicant

Shengde Que(Vice general manager)
[email protected]86-752-6158333Fax: 86-752-6158339

Technical Contact

Audix Technology (Shenzhen) Co., Ltd.Ken Lu
[email protected]86-755-2663-9497

52 Block Shenzhen Science & Industry · Shenzhen · China

Non-Technical Contact

Audix Technology (Shenzhen) Co., Ltd.Kris Zheng
[email protected]86-755-2663-9497

Test Firm

Audix Technology (Shenzhen) Co.Smart Tsai
[email protected]86-755-663-9495Fax: 86-755-663-2877

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Zhan Xiang Technology (Hui Zhou) CO., LTD

Flat Panel Bracket R/C Transmitter - FCC ID V26PX-T0904 - Zhan Xiang Technology (Hui Zhou) CO., LTD
V26PX-T0904

Flat Panel Bracket R/C Transmitter

Mar 15, 2008

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter