Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Series 9000 SDK Getting Started Document No.: 9000SDK-DOC-001 Revision: A5 Travis Gray Mobile Knowledge Corp 308 Legget Drive, Kanata, Ontario, Canada, K2K 1Y6 T: (613) 287-5020, F: (613) 287-5021 E: [email protected] , W: www.mobile-knowledge.com Series 9000 SDK Getting Started Manual REVISION HISTORY Date Revision Description 22 April 2005 A0 Initial Draft – Travis Gray 28 April 2005 A1 Updates with Cable Specifics 14 November 2006 A2 Notes Related to Limites of Intel Strata Flash Component 2 April 2007 A3 GPRS References Added as Section 4. 28 June 2007 A4 Updated GPRS Safety Notification. 9 July 2007 A5 Added additional statement to GPRS Safety Notification. Copyright Copyright © 2005 Mobile Knowledge Corp All Rights Reserved. This document and the subject matter contained herein are proprietary items to which Mobile Knowledge Corp. retains exclusive rights to reproduction, manufacture, and sale. This proposal is submitted in confidence, for the use of the recipient alone, or in conjunction with Mobile Knowledge Corp. and its licensees, and for no other purpose whatsoever unless permission for further disclosure is expressly granted in writing. Information in this document is subject to change. For additional copies of this document, please contact: Mobile Knowledge Corp 308 Legget Drive Kanata, Ontario, Canada, K2K 1Y6 Phone: 1-613-287-5020 Fax: 1-613-287-5021 e-mail: [email protected] web: www.mobile-knowledge.com 9000 SDK Getting Started - A5.doc © Mobile Knowledge Corp. Page 2 of 17 Series 9000 SDK Getting Started Manual 9000 SDK Getting Started - A5.doc © Mobile Knowledge Corp. Page 3 of 17 Series 9000 SDK Getting Started Manual TABLE OF CONTENTS Revision History..........................................................................................................................................2 Table of Contents........................................................................................................................................4 1. Introduction......................................................................................................................................5 1.1 What’s Included..............................................................................................................................5 1.2 What’s in this Document.................................................................................................................6 2. System Description..........................................................................................................................7 2.1 Series 9000 MDT Hardware...........................................................................................................7 2.2 Series 9000 MDT Software............................................................................................................8 2.3 The Series 9000 SDK Software...................................................................................................... 9 3. Working with the Series 9000 MDT...............................................................................................10 3.1 Powering the Series 9000............................................................................................................10 3.2 Initial Hardware Setup (RS-232 Serial)........................................................................................10 3.3 Subsequent Hardware Setup (Ethernet)......................................................................................11 3.4 Software Setup.............................................................................................................................11 3.5 Development PC Setup................................................................................................................12 3.6 The Series 9000 SDK API Library and Online Help File..............................................................13 4. Optional Public Data Radio Modem.............................................................................................15 4.1 Safety Notification:........................................................................................................................15 5. Additional Resources....................................................................................................................16 6. Series 9000 Cabling.......................................................................................................................17 6.1 Cable - Series 9000 Power (PN 850-0231-000)...........................................................................17 6.2 Cable – Series 9000 COM/IO (PN 850-0230-000).......................................................................17 6.3 Cable – Series 9000 COM Extender (PN 850-0233-000)............................................................17 9000 SDK Getting Started - A5.doc © Mobile Knowledge Corp. Page 4 of 17 Series 9000 SDK Getting Started Manual 1. INTRODUCTION The Mobile Knowledge Inc. Series 9000 Software Development Kit (SDK) includes everything you need to develop applications on the Series 9000 Mobile Data Terminal (MDT). The MDT and development environment are described in Section 2 – System Description. 1.1 What’s Included The Series 9000 SDK ships with the following hardware and software: Hardware Part Number Series 9000 MDT 960-2470-xxx Series 9000 Accessories Kit 360-2437-000 GPS Antenna (Magnetic Mount) 360-0004-SMA Cable - Series 9000 Power 850-0231-000 Cable – Series 9000 COM/IO 850-0230-000 Cable – Series 9000 COM Extender 850-0233-000 Power Switch 650-0074-000 Emergency Switch 550-0111-000 Emergency Switch Collar 550-0112-000 Wire, Terminal Lugs, Mounting Screws, Fuse, Tie Wraps Various Compact Flash Ethernet Card (Socket Communications) 383-0003-000 Patch Cable (7ft, Black, Cat 5, RJ45-RJ 45) 550-0153-000 Cross-Over Cable (8ft, Cat 5, RJ45-RJ45) 850-0189-000 Null Modem Adapter (10ft, F-F) 850-0227-000 Mounting Bracket – HIN…
Text truncated - open the document above for the full version.
FCC-ID VBG-MKC900XY2Z PREDICTION OF MPE AT A GIVEN DISTANCE Calculations can be made to predict RF field strength and power density levels around typical RF sources using the general equations (3) and (4) on page 19 of the following FCC document: “OET Bulletin 65, Edition 97-01 - Evaluating Compliance with FCC Guidelines for Human Exposure to Radio frequency Electromagnetic Fields”. These equations are generally accurate in the far field of an antenna but will over predict power density in the near field, where they could be used for making a “worst case” prediction. S = PG/4πR 2 (3) Where S = power density (in appropriate units, e.g. mW/cm 2 ) P = power input to the antenna (in appropriate units e.g. mW) G = power gain of the antenna in the direction of interest relative to the isotropic radiator R = distance to the center of radiation of the antenna (appropriate units e.g. cm) or, S = EIRP/4πR 2 (4) Where EIRP = Equivalent Isotropically radiated power General Limits: §1.1307 Cellular Radiotelephone Service (subpart H of part 22) Non-building-mounted antennas: height above ground level to lowest point of antenna < 10 m and total power of all channels > 1000 W ERP (1640 W EIRP) §1.1307 Personal Communications Services (part 24) Broadband PCS (subpart E): non-building-mounted antennas: height above ground level to lowest point of antenna < 10 m and total power of all channels > 2000 W ERP (3280 W EIRP) §1.1310 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) (B) Limits for General Population/Uncontrolled Exposure 300–1500 MHz: f/1500 mW/cm² 1500–100,000 MHz: 1.0 mW/cm² §2.1091 No routine evaluation required when the device ...operate at frequencies of 1.5 GHz or below and their effective radiated power (ERP) is 1.5 watts or more, or if they operate at frequencies above 1.5 GHz and their ERP is 3 watts or more. FCC-ID VBG-MKC900XY2Z §24.232 (a) Base stations are limited to 1640 watts peak equivalent isotropically radiated power (e.i.r.p.) with an antenna height up to 300 meters HAAT. b) Mobile/portable stations are limited to 2 watts e.i.r.p. peak power, ... §22.913 (a) Maximum ERP. The effective radiated power (ERP) of base transmitters and cellular repeaters must not exceed 500 Watts. The ERP of mobile transmitters and auxiliary test transmitters must not exceed 7 Watts. The table below is excerpted from Table 1B of 47 CFR 1.1310 titled “Limits for Maximum Permissible Exposure (MPE), Limits for General Population/Uncontrolled Exposure” Frequency Range (MHz) Power Density (mW/cm 2 ) 300 -1500 f/1500 1500 - 100000 1.0 FCC-ID VBG-MKC900XY2Z Prediction for Part 22 Maximum radiated power EIRP: 33.06dBm (2.02W) @ 848.8MHz, ERP: 30.92dBm, 1.236W Lowest limit for 850 MHz fixed operations (@20cm) where no routine evaluation is required is § 1.1310: (f/1500)mW/cm 2 =0.5659 mW/cm 2 Calculated at distance of 20cm for reference antenna Radial Larsen MMCP3ESMA Power density = 2020 / (4 x pi x 20 2 ) = 0.4019 mW/cm 2 Lowest limit for 850 MHz mobile operations (@20cm) where no routine evaluation is required is § 2.1091 : 1.5W ERP Result: Configuration complies with rules as power density is below MPE limit. Prediction for Part 24 Maximum radiated power EIRP: 28.79dBm (0.757W) @1880MHz Lowest limit for 1900 MHz fixed operations (@20cm) where no routine evaluation is required is § 1.1310: 1 mW/cm 2 Calculated at distance of 20cm for reference antenna Option J: Power density = 757 / (4 x pi x 20 2 ) = 0.1506mW/cm 2 Lowest limit for 1900 MHz mobile operations (@20cm) where no routine evaluation is required is § 2.1091 : 3W ERP but §24.232 : 2W EIRP Result: Configuration complies with rules as power density is below MPE limit. Date: 2007-6-29 Name: Peter Mu Title: Project Engineer Company: Cetecom Inc. Address: 411 Dixon Landing Rd, Milpitas, CA 95035, USA Phone: +1 408 586 6221 Email: [email protected]
ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH TEST - REPORT FCC RULES PARTS 22 and 24 FCC ID: O9EQ2426-SK Test report no.: G0M20304-7780-T-47 FCC ELECTRONIC TECHNOLOGY SYSTEMSSTORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBHPHONE +49-33631-888 00 FAX +49-33631-888 66 ETS Dr. Genz GmbH, GermanyRegistration number: G0M20304-7780-T-47Page 1 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1General information 1.1Notes 1.2Testing laboratory 1.3Details of approval holder 1.4Application details 1.5Test item 1.6Test standards 2Technical test 2.1Summary of test results 2.2Test environment 2.3Test equipment utilized 2.4Test Procedure 3 Test Results 4 RF Power Output, FCC 2.1046 4.1 Test Procedure 4.2 Test Results 5 Radiated Power FCC 22.913, FCC 24.232 5.1 Test Procedure 5.2 Test Results 6 Modulation Deviation Limiting, FCC 2.1047, 22.915(b)(c) 6.1 Test Procedure 6.2 Test Results 7 Audio Filter Characteristics, FCC 22.915(d) 7.1 Test Procedure 7.2 Test Results 8 Emission Limitations, , FCC 2.1049 8.1 Test Procedure 8.2 Test Results 9 Occupied Bandwidth FCC 22.917(b)(d); FCC 2.1049 9.1 Test Procedure 9.2 Test Results 10 Emission in Receiver Critical Band FCC 22.917(f) 10.1Test Procedure 10.2Test results 11 Out of Band Emissions at Antenna Terminals , FCC 2.1051, FCC 22.917(e), FCC 22.917(f), 24.238(a) 11.1. Test Procedure 11.2. Test Results ETS Dr. Genz GmbH, GermanyRegistration number: G0M20304-7780-T-47Page 2 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 12 Field Strength of Spurious Radiation, FCC 2.1053, 24.236 13.1 Test Procedure 12.2 Test Results 13 Line Conducted Emissions, FCC 15.207 13.1 Test Procedure 13.2 Test Results 14 Frequency Stability vs Temperature, FCC 2.1055, 22.355, 24.235 14.1 Test Procedure 14.2 Test Equipment 15 Frequency Stability vs Voltage, FCC 2.1055, 22.355, 24.235 15.1 Test Procedure 15.2 Test Equipment ETS Dr. Genz GmbH, GermanyRegistration number: G0M20304-7780-T-47Page 3 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1General Information 1.1Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extractes from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Tester: 15.04.2003F. Schulz DateETS-Lab.NameSignature Technical responsibility for area of testing: 15.04.2003Dr. Genz DateETSNameSignature ETS Dr. Genz GmbH, GermanyRegistration number: G0M20304-7780-T-47Page 4 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telefon : +49 33631 888 00 Telefax : +49 33631 888 66 1.2.2Details of accreditation status A CCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: TTI-P-G 126/96 ACCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96 FCC FILED TEST LABORATORY REG. NO. 96970 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY: BLUETOOTH QUALIFICATION REVIEW BOARD (BQRF) I NDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 A2LA A CCREDITEDCertificate Number: 1983-01 1.3Details of approval holder Name: Wavecom S.A. Street: 12 Boulevard Garibaldi Town: 92442 Issy Les Moulineaux Cedex Country: France Telephone: +33 1 4629 0800 Fax: +33 1 4629 9357 Contact: Mr. Dan Venturini Telephone: +33 1 4629 0800 ETS Dr. Genz GmbH, GermanyRegistration number: G0M20304-7780-T-47Page 5 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4Application details Date of receipt of application: 14.04.2003 Date of receipt of test item: 14.04.2003 Date of test: 14.04.2003 1.5Test item Description of test item: GSM/GPRS Module Type identification: Q2426Version: 4.0 Serial number: Test model without serial number. Photos: See annex Technical data Frequency range Tx – GSM 850: 824.2 – 848.80 MHz Frequency range Tx – PCS: 1850.2 – 1909.8 MHz Frequency range Rx - GSM 850: 869.2 – 893.8 MHz Frequency range Rx - PCS: 1930.2 – 1989.8 MHz Antenna Gain: -1 dBi Power supply : 3,7 V DC Operating mode: duplex Type of modulation: GMSK (GSM modulation) Emission: GXW Manufacturer: (if applicable) Name: Street: Town: Country: ETS Dr. Genz GmbH, GermanyRegistration number: G0M20304-7780-T-47Page 6 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.6Test standards Technical standard : FCC Parts 22, 24, 2, 15 Additional information: Because of using the GSM 850 as an alternative technology in 850 MHz band, not all test cases of FCC Part 22 are required. For testing, the GSM/GPRS Module Q2426 was tested in the Starter Kit as test environment. The .Allgon antenna was used for test purposes only. 2Technical test 2.1Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests performed. or The deviations as specified in 2.5 were ascertained in the course of the tests performed. 2.2Test environment Temperature: 23 o C Relative humidity content: 20 ...75 % Air pressure: 86 ...103 kPa ETS Dr. Genz GmbH, GermanyRegistration number: G0M20304-7780-T-47Page 7 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 2.3Test equipment utilized No.Test equipmen…
Text truncated - open the document above for the full version.
FCC Test Report FCC Part 22, 24 / RSS 132,133 FOR: Mobile Data Terminal with integrated Wavecom Q2426-amr GSM/GPRS module. MODEL #: S9000 Mobile Knowledge Corp. 308 Legget Drive Kanata, Ontario, K2K 1Y6 Canada FCC ID: VBG-MKC900XY2Z TEST REPORT #: EMC_ MOBL2_001_07002_FCC22_24 DATE: 2007-6-29 Bluetooth Qualification Test Facility (BQTF) FCC listed: A2LA accredited IC recognized # 3925 CETECOM Inc. 411 Dixon Landing Road Milpitas, CA 95035 U.S.A. Phone: + 1 (408) 586 6200 Fax: + 1 (408) 586 6299 E-mail: [email protected] http://www.cetecom.com CETECOM Inc. is a Delaware Corporation with Corporation number: 2113686 Board of Directors: Dr. Harald Ansorge, Dr. Klaus Matkey, Hans Peter May © Copyright by CETECOM Test Report #: EMC_ MOBL2_001_07002_FCC22_24 Date of Report: 2007-6-29 Page 2 of 53 This report shall not be reproduced except in full without the written approval of: CETECOM, Inc. Table of Contents .....................................................................................................................................4 1ASSESSMENT .........................................................................................................................................4 EMC & Radio .........................................................................................................................................4 EMC & Radio ................................................................................................................5 2ADMINISTRATIVE DATA 2.1 ......................5 IDENTIFICATION OF THE TESTING LABORATORY ISSUING THE EMC TEST REPORT 2.2 ....................................................................................................5 IDENTIFICATION OF THE CLIENT 2.3 .....................................................................................5 IDENTIFICATION OF THE MANUFACTURER .................................................................................................6 3EQUIPMENT UNDER TEST (EUT) 3.1 SPECIFICATION OF THE EQUIPMENT UNDER TEST..........................................................................6 T 3.2 ............................................................6 IDENTIFICATION OF THE EQUIPMENT UNDER TEST (EUT) 3.3 ................................................................................6 IDENTIFICATION OF ACCESSORY EQUIPMENT ......................................................................................................7 4SUBJECT OF INVESTIGATION ..............................................................................................................................8 5MEASUREMENTS 5.1 ........................................................................................................................8 RF POWER OUTPUT 5.1.1 .......................................................8 FCC 2.1046 Measurements required: RF power output. 5.1.2 ....................................................................................................................................8 Limits: 5.1.2.1 ...............................................................8 FCC 22.913 (a) Effective radiated power limits. 5.1.2.2 ........................................................................................8 FCC 24.232 (b)(c) Power limits. 5.1.3 ..............................................................8 Conducted Output Power Measurement procedure: 5.1.4 .................................................................9 Radiated Output Power Measurement procedure: 5.1.5 ................................................................................................10 ERP Results 850 MHz band: 5.1.6 .............................................................................................10 EIRP Results 1900 MHz band: 5.2 .........................................................................17 OCCUPIED BANDWIDTH/EMISSION BANDWIDTH 5.2.1 ................................................17 FCC 2.1049 Measurements required: Occupied bandwidth 5.2.2 ...................................................17 Occupied / emission bandwidth measurement procedure: 5.2.3 .....................................................18 Occupied / Emission bandwidth results 850 MHz band: 5.3 ................................................................................................................19 FREQUENCY STABILITY 5.3.1 .....................................................................................................................................19 Limit 5.3.2 ................................................................................20 FREQUENCY STABILITY (GSM-850) 5.3.3 ...............................................................................20 FREQUENCY STABILITY (PCS-1900) 5.4 ..............................................................................................21 SPURIOUS EMISSIONS CONDUCTED 5.4.1 ...............21 FCC 2.1051 Measurements required: Spurious emissions at antenna terminals. 5.4.2 ..................................................................................................................................21 Limits: 5.4.2.1 ..............................................21 FCC 22.917 Emission limitations for cellular equipment. 5.4.2.2 ................................21 FCC 24.238 Emission limitations for Broadband PCS equipment. 5.4.3 ................................................22 Conducted out of band emissions measurement procedure: 5.5 .................................................................................................23 SPURIOUS EMISSIONS RADIATED 5.5.1 .......................23 FCC 2.1053 Measurements required: Field strength of spurious radiation. 5.5.2 ..................................................................................................................................23 Limits: 5.5.2.1 ..............................................23 FCC 22.917 Emission limitations for cellular equipment. 5.5.2.2 .............................…
Text truncated - open the document above for the full version.
PAGE 1 OF 7 Test Setup Photos FOR: Mobile Data Terminal with integrated Wavecom Q2426-amr GSM/GPRS module. MODEL #: S9000 Mobile Knowledge Corp. 308 Legget Drive Kanata, Ontario, K2K 1Y6 Canada FCC ID: VBG-MKC900XY2Z TEST REPORT #: EMC_ MOBL2_001_07002_FCC22_24 DATE: 2007-6-29 Bluetooth Qualification Test Facility (BQTF) FCC listed: A2LA accredited IC recognized # 3925 CETECOM Inc. 411 Dixon Landing Road Milpitas, CA 95035 U.S.A. Phone: + 1 (408) 586 6200 Fax: + 1 (408) 586 6299 E-mail: [email protected] http://www.cetecom.com CETECOM Inc. is a Delaware Corporation with Corporation number: 2113686 Board of Directors: Dr. Harald Ansorge, Dr. Klaus Matkey, Hans Peter May © Copyright by CETECOM PAGE 2 OF 7 Table of Contents .................................................................................................................................... 3 1ASSESSMENT ..................................................................................................................... 4 2TEST SETUP PHOTOS 2.1 ...................................................................................... 4 RADIATED SPURIOUS EMISSIONS FRONT 2.2 ........................................................................................ 5 RADIATED SPURIOUS EMISSIONS BACK 2.3 ..................................................................................... 6 AC LINE CONDUCTED EMISSIONS FRONT 2.4 ........................................................................................ 7 AC LINE CONDUCTED EMISSIONS SIDE This report shall not be reproduced except in full without the written approval of: CETECOM, Inc. PAGE 3 OF 7 1 Assessment The following is in compliance with the applicable criteria specified in FCC rules Parts 2, 22 and 24 of Title 47 of the Code of Federal Regulations and in compliance with the applicable criteria specified in Industry Canada rules RSS132 and RSS133. Company Description Model # Mobile Knowledge Corp. Mobile Data Terminal S9000 Date:2007/7/2 Name: Peter Mu Title: Project Engineer Company: Cetecom Inc. Address: 411 Dixon Landing Rd, Milpitas, CA 95035, USA Phone: +1 408 586 6221 Email: [email protected] This report shall not be reproduced except in full without the written approval of: CETECOM, Inc. PAGE 4 OF 7 2 TEST SETUP PHOTOS 2.1 Radiated Spurious Emissions Front This report shall not be reproduced except in full without the written approval of: CETECOM, Inc. PAGE 5 OF 7 2.2 Radiated Spurious Emissions Back This report shall not be reproduced except in full without the written approval of: CETECOM, Inc. PAGE 6 OF 7 2.3 AC Line Conducted Emissions Front This report shall not be reproduced except in full without the written approval of: CETECOM, Inc. PAGE 7 OF 7 2.4 AC Line Conducted Emissions Side This report shall not be reproduced except in full without the written approval of: CETECOM, Inc.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 22H | 824.2 MHz - 848.8 MHz | 1.3335 W | 300KGXW | 0.055 ppm |