
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Date: 03.26.2012 Federal Communications Commission Authorization and Evaluation Division FCC ID: VLE15034-PPL-1 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this application as outlined below: 1. Block diagram 2. Schematics 3. Operation Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might to harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the grant for this application. Sincerely, Name:Bob Cheng Company name: Asian Express Holdings Limited Tel.:0755-85235694 Fax:0755-85235743
AGENCY AUTHORIZATION LETTER FCC ID: VLE15034-PPL-1 Date: 03.26.2012 To whom it may concern: We, the undersigned, hereby authorize Bureau Veritas Shenzhen Co. Ltd Dongguan Branch., to act on our behalf, as our agent, in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification. Any act carried out by BVDG within the scope of this authorization shall have the same effects as our own. This authorization shall expire 6 months form original date. If you have any Questions regarding the authorization, please don’t hesitate to contact us. Thank you. Sincerely, Name:Bob Cheng Company name: Asian Express Holdings Limited Tel.:0755-85235694 Fax:0755-85235743
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Reference No.: 120312N043 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Reference No.: 120312N043 ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Reference No.: 120312N043 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Reference No.: 120312N043
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 on 21 Report Version 1 Test Report No.:FC120312N043 TEST REPORT To: Asian Express Holdings Ltd. Address: 4F, -4, No.669 Jingping Rd., Zhonghe City, Taipei Country 235, Taiwan R.O.C Manufacturer or Supplier Asian Express Holdings Ltd. Address 4F, -4, No.669 Jingping Rd., Zhonghe City, Taipei Country 235, Taiwan R.O.C Product: SPEED STAR Brand Name: N/A Model: 15034-PPL-BK Date of tests: March. 13 ~ May 10, 2012 the tests have been carried out according to the requirements of the following standards: FCC Part 15, Subpart C (Section 15.249) CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared by Glyn He Project Engineer / EMC Department Approved by Sam Tung Manager / EMC Department Date: May 10, 2012 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 on 21 Report Version 1 Test Report No.:FC120312N043 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 3 1 SUMMARY OF TEST RESULTS.................................................................................................... 4 2 MEASUREMENT UNCERTAINTY................................................................................................. 4 3 GENERAL INFORMATION ............................................................................................................5 3.1 GENERAL DESCRIPTION OF EUT ........................................................................................... 5 3.2 DESCRIPTION OF TEST MODES ............................................................................................. 6 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 6 3.4 DESCRIPTION OF SUPPORT UNITS ....................................................................................... 6 4. TEST TYPES AND RESULTS........................................................................................................ 7 4.1 RADIATED EMISSION MEASUREMENT .................................................................................. 7 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT ...................................................... 7 4.1.2 TEST INSTRUMENTS....................................................................................................... 8 4.1.3 TEST PROCEDURES ....................................................................................................... 9 4.1.4 DEVIATION FROM TEST STANDARD ............................................................................. 9 4.1.5 TEST SETUP................................................................................................................... 10 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 10 4.1.7 TEST RESULTS ...............................................................................................................11 4.2 20 DB BANDWIDTH MEASUREMENT...................................................................................... 15 4.2.1 LIMITS OF 20dB BANDWIDTH MEASUREMENT.......................................................... 15 4.2.2 TEST INSTRUMENTS..................................................................................................... 15 4.2.3 TEST PROCEDURE........................................................................................................ 16 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 16 4.2.5 TEST SETUP................................................................................................................... 17 4.2.6 EUT OPERATING CONDITIONS .................................................................................... 17 4.2.7 TEST RESULTS .............................................................................................................. 18 5 PHOTOGRAPHS OF THE TEST CONFIGURATION .................................................................. 20 6 APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB ................................................................................................................................ 21 Bureau Veritas Shenzhen Co., Ltd. Don…
Text truncated - open the document above for the full version.
1 Set-up for radiated emission test <Frequency Range 30MHz~1GHz> <Frequency Range above1GHz>
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Cloud Rider Drone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Air Micro Drone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
ZIP Micro Drone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Air Micro Drone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Zip Micro Drone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter