FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Cellvine Ltd./
  3. VUV-LTE700UC26

VUV-LTE700UC26LTE 700 Off the Air Repeater

Cellvine Ltd.
LTE 700 Off the Air Repeater - FCC ID VUV-LTE700UC26 - Cellvine Ltd.
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Dec 02, 2010
Application Purpose
Original Equipment
Date of Application
Dec 02, 2010
Equipment Note
LTE 700 Off the Air Repeater
Frequency Range
782.00000000 - 782.00000000
Company
Cellvine Ltd.
Country
Israel

Documents & Files

Select a file to view

Users Manual

β†—
β†—

Cover Letter(s)

β†—
β†—
β†—
β†—

External Photos

β†—
β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—
β†—

Test Report

β†—
β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER MANUAL BDA-700UC-26-52-AA-MBX-VZW LTE 700 MHZ OVER-THE-AIR REPEATER CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 II REVISIONS Rev Description of Change Revision date Revised by IMPORTANT NOTICE This manual contains proprietary information of Cellvine Ltd. No part of this publication may be reproduced in any form whatsoever without prior written approval of Cellvine Ltd. Cellvine and/or its agents and distributors make no claims or warranties concerning the fitness of the products or documentation for any purpose other than what is specifically mentioned in this manual. For more information contact Cellvine at the address below or contact your local distributor. CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 iii YEAR LIMITED HARDWARE AND SOFTWARE WARRANTY Cellvine Ltd. warrants all repeater Products against electrical malfunction for a period of One (1) year from shipment of the product to the purchaser. If Cellvine receives notice of defects during the warranty period, Cellvine will either replace or repair the products. WARRANTY EXCLUSIONS AND LIMITATIONS The warranty shall not apply to defects resulting from improper operation, inadequate maintenance, or unauthorized use or modification by the customer of the repeater products or software. The warranty service and service beyond the warranty period described herein are the customer's sole remedies. OBTAINING SERVICE DURING AND BEYOND WARRANTY PERIOD To obtain warranty service, the customer shall return the repeater product to Cellvine Ltd with date and proof of purchase and an explanation of the problem. The customer shall pay for shipping charges and Cellvine shall pay for return shipping. For service beyond the warranty period, contact Cellvine for details of available service. GETTING HELP The repeaters have undergone extensive testing prior to shipment. All of the functions have been thoroughly tested. However, if there are problems that you discover, please call us. We are here to help. ABOUT THIS MANUAL This user manual is intended for experienced installation technicians and engineers. It contains the following: o A general description of the BDA-700UC-26-52-AA-MBX-VZW repeater system and system components o Installation overview o Repeater system operation CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 iii Contacting Cellvine Headquarter Cellvine Ltd. 8 Moshe Aviv (Ha'amal) st, 60371Or-Yehuda ISRAEL Phone: +972-3634-8881 Fax: +972-3-6348882 [email protected] U.S. Office Cellvine LLC 80 Wesley Street South Hackensack NJ 07606 Phone : 201-531-8600 Fax : 201-531-8606 [email protected] CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 iv Contents 1. INTRODUCTION .......................................................................1 1.1. General Description.................................................................. 1 2. SYSTEM COMPONENTS .........................................................2 2.1. BDA-700UC-26-52-AA-MBX-VZW Repeater Kit ..................... 2 2.2. REPEATER UNIT....................................................................... 2 2.3. Repeater UNIT RF Specifications ............................................ 3 2.4. Repeater Block diagram........................................................... 4 2.5. Dimensions and Weight ........................................................... 5 2.6. Repeater unit Interfaces ........................................................... 6 3. INSTALLATION ........................................................................7 3.1. Unpacking and Inspection ....................................................... 7 3.2. Operating Environment ............................................................ 8 3.3. Pre-Installation Inspection ....................................................... 8 3.4. Antennas Installation................................................................ 8 3.4.1. Coverage (Service) Antennas .................................................. 8 3.4.2. DONOR Antenna ....................................................................... 9 3.5. Repeater unit Mechanical Installation ...................................10 3.5.1. Repeater Installation ..............................................................10 3.5.2. Power supply Installation.......................................................12 3.6. Repeater cable connection ....................................................14 CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 v 3.7. System INDICATIONS.............................................................15 3.8. Tuning Donor antenna............................................................16 3.9. Antenna Isolation....................................................................16 4. REPEATER MONITORING AND CONTROL ..........................17 4.1. preparing the repeater for local connection .........................17 4.1.1. software application ...............................................................17 4.1.2. System Requirements ............................................................17 4.2. Define PC/laptop internet settings.........................................18 5. SOFTWARE OPERATION ......................................................20 5.1. Software Password and unit detailes screen .......................21 5.2. Technician setup screen ........................................................22 5.2.1. maximum gain limit ................................................................24 5.2.2. aGC Power ..............................................................................24 5.2.3. AGC ON/OFF ...........................................................................25 5.2.3.1. Downlink Gain..................................................…

Text truncated - open the document above for the full version.

Users Manual

USER MANUAL BDA-700UC-26-52-AA-MBX-VZW LTE 700 MHZ OVER-THE-AIR REPEATER CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 II REVISIONS Rev Description of Change Revision date Revised by IMPORTANT NOTICE This manual contains proprietary information of Cellvine Ltd. No part of this publication may be reproduced in any form whatsoever without prior written approval of Cellvine Ltd. Cellvine and/or its agents and distributors make no claims or warranties concerning the fitness of the products or documentation for any purpose other than what is specifically mentioned in this manual. For more information contact Cellvine at the address below or contact your local distributor. CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 iii YEAR LIMITED HARDWARE AND SOFTWARE WARRANTY Cellvine Ltd. warrants all repeater Products against electrical malfunction for a period of One (1) year from shipment of the product to the purchaser. If Cellvine receives notice of defects during the warranty period, Cellvine will either replace or repair the products. WARRANTY EXCLUSIONS AND LIMITATIONS The warranty shall not apply to defects resulting from improper operation, inadequate maintenance, or unauthorized use or modification by the customer of the repeater products or software. The warranty service and service beyond the warranty period described herein are the customer's sole remedies. OBTAINING SERVICE DURING AND BEYOND WARRANTY PERIOD To obtain warranty service, the customer shall return the repeater product to Cellvine Ltd with date and proof of purchase and an explanation of the problem. The customer shall pay for shipping charges and Cellvine shall pay for return shipping. For service beyond the warranty period, contact Cellvine for details of available service. GETTING HELP The repeaters have undergone extensive testing prior to shipment. All of the functions have been thoroughly tested. However, if there are problems that you discover, please call us. We are here to help. ABOUT THIS MANUAL This user manual is intended for experienced installation technicians and engineers. It contains the following: o A general description of the BDA-700UC-26-52-AA-MBX-VZW repeater system and system components o Installation overview o Repeater system operation CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 iii Contacting Cellvine Headquarter Cellvine Ltd. 8 Moshe Aviv (Ha'amal) st, 60371Or-Yehuda ISRAEL Phone: +972-3634-8881 Fax: +972-3-6348882 [email protected] U.S. Office Cellvine LLC 80 Wesley Street South Hackensack NJ 07606 Phone : 201-531-8600 Fax : 201-531-8606 [email protected] CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 iv Contents 1. INTRODUCTION .......................................................................1 1.1. General Description.................................................................. 1 2. SYSTEM COMPONENTS .........................................................2 2.1. BDA-700UC-26-52-AA-MBX-VZW Repeater Kit ..................... 2 2.2. REPEATER UNIT....................................................................... 2 2.3. Repeater UNIT RF Specifications ............................................ 3 2.4. Repeater Block diagram........................................................... 4 2.5. Dimensions and Weight ........................................................... 5 2.6. Repeater unit Interfaces ........................................................... 6 3. INSTALLATION ........................................................................7 3.1. Unpacking and Inspection ....................................................... 7 3.2. Operating Environment ............................................................ 8 3.3. Pre-Installation Inspection ....................................................... 8 3.4. Antennas Installation................................................................ 8 3.4.1. Coverage (Service) Antennas .................................................. 8 3.4.2. DONOR Antenna ....................................................................... 9 3.5. Repeater unit Mechanical Installation ...................................10 3.5.1. Repeater Installation ..............................................................10 3.5.2. Power supply Installation.......................................................12 3.6. Repeater cable connection ....................................................14 CELLVINE LTD. BDA-700UC-26-52-AA-MBX-VZW Β© 2010 Cellvine Ltd, all rights reserved Ver.1.3:2010-10 v 3.7. System INDICATIONS.............................................................15 3.8. Tuning Donor antenna............................................................16 3.9. Antenna Isolation....................................................................16 4. REPEATER MONITORING AND CONTROL ..........................17 4.1. preparing the repeater for local connection .........................17 4.1.1. software application ...............................................................17 4.1.2. System Requirements ............................................................17 4.2. Define PC/laptop internet settings.........................................18 5. SOFTWARE OPERATION ......................................................20 5.1. Software Password and unit detailes screen .......................21 5.2. Technician setup screen ........................................................22 5.2.1. maximum gain limit ................................................................24 5.2.2. aGC Power ..............................................................................24 5.2.3. AGC ON/OFF ...........................................................................25 5.2.3.1. Downlink Gain..................................................…

Text truncated - open the document above for the full version.

External Photos

Photograph 1. lte 700 uc Photograph 2. lte 700 uc-1 Photograph 3. lte 700 uc-2 Photograph 4. lte 700 uc-3 Photograph 5. lte 700 uc-4 Photograph 6. lte 700 uc-5 Photograph 7. lte 700 uc-6

External Photos

Photograph 1. lte 700 uc Photograph 2. lte 700 uc-1 Photograph 3. lte 700 uc-2 Photograph 4. lte 700 uc-3 Photograph 5. lte 700 uc-4 Photograph 6. lte 700 uc-5 Photograph 7. lte 700 uc-6

ID Label/Location Info

CELLVINE LTD. P.O.B 575 OR-YEHUDA 60371 ISRAEL TEL: 972-3-6348881 FAX: 972-3-6348882 WWW.Cellvine.com BDA-700UC-26-52-AA-MBX-VZW Repeater FCC label Label position

ID Label/Location Info

CELLVINE LTD. P.O.B 575 OR-YEHUDA 60371 ISRAEL TEL: 972-3-6348881 FAX: 972-3-6348882 WWW.Cellvine.com BDA-700UC-26-52-AA-MBX-VZW Repeater FCC label Label position

Internal Photos

Photograph 1. DC CONVERTER ADJ_PWI0364 Photograph 2. DC CONVERTER ADJ_PWI0364-1 Photograph 3. DC CONVERTER ADJ_PWI0364-2 Photograph 4. HPAC0017 Photograph 5. HPAC0017-1 Photograph 6. lte 15dbm_if_con_emb_22_11_09 PWF0523 Photograph 7. lte 15dbm_if_con_emb_22_11_09 PWF0523-1 Photograph 8. lte 15dbm_if_con_emb_22_11_09 PWF0523-2 Photograph 9. lte 15dbm_if_con_emb_22_11_09 PWF0523-3 Photograph 10. lte 15dbm_if_con_emb_22_11_09 PWF0523-4 Photograph 11. lte 15dbm_if_con_emb_22_11_09 PWF0523-5 Photograph 12. lte 15dbm_if_con_emb_22_11_09 PWF0523-6 Photograph 13. lte 15dbm_if_con_emb_22_11_09 PWF0523-7 Photograph 14. lte 15dbm_if_con_emb_22_11_09 PWF0523-8 Photograph 15. M501 MOTHER BOARD_PWI0510 Photograph 16. M501 MOTHER BOARD_PWI0510-1 Photograph 17. M501 MOTHER BOARD_PWI0510-2 Photograph 18. M501 MOTHER BOARD_PWI0510-3 Photograph 19. Mobile Side Duplexer PWI0531 Photograph 20. Mobile Side Duplexer PWI0531-1 Photograph 21. Pico Booster PWI0530 Photograph 22. Pico Booster PWI0530-1 Photograph 23. Pico Booster PWI0530-2 Photograph 24. Pico Booster PWI0530-3

Internal Photos

Photograph 1. DC CONVERTER ADJ_PWI0364 Photograph 2. DC CONVERTER ADJ_PWI0364-1 Photograph 3. DC CONVERTER ADJ_PWI0364-2 Photograph 4. HPAC0017 Photograph 5. HPAC0017-1 Photograph 6. lte 15dbm_if_con_emb_22_11_09 PWF0523 Photograph 7. lte 15dbm_if_con_emb_22_11_09 PWF0523-1 Photograph 8. lte 15dbm_if_con_emb_22_11_09 PWF0523-2 Photograph 9. lte 15dbm_if_con_emb_22_11_09 PWF0523-3 Photograph 10. lte 15dbm_if_con_emb_22_11_09 PWF0523-4 Photograph 11. lte 15dbm_if_con_emb_22_11_09 PWF0523-5 Photograph 12. lte 15dbm_if_con_emb_22_11_09 PWF0523-6 Photograph 13. lte 15dbm_if_con_emb_22_11_09 PWF0523-7 Photograph 14. lte 15dbm_if_con_emb_22_11_09 PWF0523-8 Photograph 15. M501 MOTHER BOARD_PWI0510 Photograph 16. M501 MOTHER BOARD_PWI0510-1 Photograph 17. M501 MOTHER BOARD_PWI0510-2 Photograph 18. M501 MOTHER BOARD_PWI0510-3 Photograph 19. Mobile Side Duplexer PWI0531 Photograph 20. Mobile Side Duplexer PWI0531-1 Photograph 21. Pico Booster PWI0530 Photograph 22. Pico Booster PWI0530-1 Photograph 23. Pico Booster PWI0530-2 Photograph 24. Pico Booster PWI0530-3

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 The Nation’s First Licensed Nationally Recognized Testing Laboratory November 29, 2010 Cellvine 6 Yoni Netanyahu St POB 575 Yehuda, Israel 60376 Dear Ziv Shani, Enclosed is the EMC test report for compliance testing of the Cellvine, 700LTE Over-The-Air Repeater as tested to the requirements of the FCC Certification rules under Title 47 of the CFR Part 27. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\Cellvine\ EMC82453-FCC27) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. Electromagnetic Compatibility Cellvine Cover Page 700LTE Over-The-Air Repeater CFR Title 47 Part 27 & Part 15 Subpart B MET Report: EMC82453-FCC27 Β© 2010, MET Laboratories, Inc. Page ii of vii Electromagnetic Compatibility Criteria Test Report for the Cellvine 700LTE Over-The-Air Repeater Verified under FCC Certification Rules Title 47 of the CFR, Part 27 12 MET Report: EMC82453-FCC27 November 29, 2010 Prepared For: Cellvine 6 Yoni Netanyahu St POB 575 Yehuda, Israel 60376 Electromagnetic Compatibility Cellvine Cover Page 700LTE Over-The-Air Repeater CFR Title 47 Part 27 & Part 15 Subpart B Electromagnetic Compatibility Criteria Test Report for the Cellvine 700LTE Over-The-Air Repeater Tested Under FCC Certification Rules Title 47 of the CFR, Part 27 Manasi Bhandiwad, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Part 27 and Part 15 Subpart B of the FCC Rules under normal use and maintenance. Shawn McMillen, Wireless Manager Electromagnetic Compatibility Lab MET Report: EMC82453-FCC27 Β© 2010, MET Laboratories, Inc. Page iii of vii Electromagnetic Compatibility Cellvine Report Status 700LTE Over-The-Air Repeater CFR Title 47 Part 27 & Part 15 Subpart B MET Report: EMC82453-FCC27 Β© 2010, MET Laboratories, Inc. Page iv of vii Report Status Sheet Revision Report Date Reason for Revision  November 29, 2010 Initial Issue. Electromagnetic Compatibility Cellvine Table of Contents 700LTE Over-The-Air Repeater CFR Title 47 Part 27 & Part 15 Subpart B MET Report: EMC82453-FCC27 Β© 2010, MET Laboratories, Inc. Page v of vii Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview.............................................................................................................................................................4 B. References...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample.................................................................................................................................5 E. Equipment Configuration..................................................................................................................................10 F. Support Equipment ...........................................................................................................................................10 G. Ports and Cabling Information ..........................................................................................................................10 H. Mode of Operation............................................................................................................................................10 I. Method of Monitoring EUT Operation .............................................................................................................10 J. Modifications ....................................................................................................................................................11 Modifications to EUT ................................................................................................................................11 Modifications to Test Standard..................................................................................................................11 K. Disposition of EUT .......................................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 The Nation’s First Licensed Nationally Recognized Testing Laboratory November 29, 2010 Cellvine 6 Yoni Netanyahu St POB 575 Yehuda, Israel 60376 Dear Ziv Shani, Enclosed is the EMC test report for compliance testing of the Cellvine, 700LTE Over-The-Air Repeater as tested to the requirements of the FCC Certification rules under Title 47 of the CFR Part 27. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\Cellvine\ EMC82453-FCC27) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. Electromagnetic Compatibility Cellvine Cover Page 700LTE Over-The-Air Repeater CFR Title 47 Part 27 & Part 15 Subpart B MET Report: EMC82453-FCC27 Β© 2010, MET Laboratories, Inc. Page ii of vii Electromagnetic Compatibility Criteria Test Report for the Cellvine 700LTE Over-The-Air Repeater Verified under FCC Certification Rules Title 47 of the CFR, Part 27 12 MET Report: EMC82453-FCC27 November 29, 2010 Prepared For: Cellvine 6 Yoni Netanyahu St POB 575 Yehuda, Israel 60376 Electromagnetic Compatibility Cellvine Cover Page 700LTE Over-The-Air Repeater CFR Title 47 Part 27 & Part 15 Subpart B Electromagnetic Compatibility Criteria Test Report for the Cellvine 700LTE Over-The-Air Repeater Tested Under FCC Certification Rules Title 47 of the CFR, Part 27 Manasi Bhandiwad, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Part 27 and Part 15 Subpart B of the FCC Rules under normal use and maintenance. Shawn McMillen, Wireless Manager Electromagnetic Compatibility Lab MET Report: EMC82453-FCC27 Β© 2010, MET Laboratories, Inc. Page iii of vii Electromagnetic Compatibility Cellvine Report Status 700LTE Over-The-Air Repeater CFR Title 47 Part 27 & Part 15 Subpart B MET Report: EMC82453-FCC27 Β© 2010, MET Laboratories, Inc. Page iv of vii Report Status Sheet Revision Report Date Reason for Revision  November 29, 2010 Initial Issue. Electromagnetic Compatibility Cellvine Table of Contents 700LTE Over-The-Air Repeater CFR Title 47 Part 27 & Part 15 Subpart B MET Report: EMC82453-FCC27 Β© 2010, MET Laboratories, Inc. Page v of vii Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview.............................................................................................................................................................4 B. References...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample.................................................................................................................................5 E. Equipment Configuration..................................................................................................................................10 F. Support Equipment ...........................................................................................................................................10 G. Ports and Cabling Information ..........................................................................................................................10 H. Mode of Operation............................................................................................................................................10 I. Method of Monitoring EUT Operation .............................................................................................................10 J. Modifications ....................................................................................................................................................11 Modifications to EUT ................................................................................................................................11 Modifications to Test Standard..................................................................................................................11 K. Disposition of EUT .......................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Photograph 1. Conducted Emissions, Test Setup Photograph 2. Radiated Emission Limits Test Setup

Contact Information

Applicant

Richard Parker(Technical Mktg Director)
[email protected]1-404-478-7201Fax: 1-877-576-6323

Technical Contact

Cellvine LTDZiv Shani
[email protected]+972-3-6348881

8 Moshe Aviv (HaοΏ½amal) St. Β· Or Yehuda Β· Israel

Test Firm

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INCGreg Kovolenko
[email protected]4108444071Fax: 4103543313

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
227782 MHz - 782 MHz50.00 mWF9WAmp
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be professionally installed and must be fixed-mounted on indoor or outdoor permanent structures. RF exposure compliance to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of οΏ½1.1307(b)(3).