Test report no. 19011904 Page 1 of 17 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s, smart microwave sensors GmbH UMRR-12 Type 48 Annex no. 5 User Manual Functional Description Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators ANSI C63.4-2014 ANSI C63.10-2013 Test report no. 19011904 Page 2 of 17 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 User Manual / Functional Description of the test equipment (EUT) CONFIDENTIAL AND PROPRIETARY The Information contained in this document shall remain the sole exclusive property of s.m.s, smart microwave sensors GmbH and shall not be disclosed by the recipient to third parties without prior consent of s.m.s, smart microwave sensors GmbH in writing. UMRR-12 Type 48 User Manual USA CAN 100MHz.docx Version 1 I Page 1 of 15 I June 27, 2019 Project Documentation | UMRR-12 Type 48 User Manual Project Number: ... SMS Project Number: Project Title: UMRR-12 Type 48 User Manual Keyword(s): UMRR-12 Type 48 radar sensor Date: June 27, 2019 Document: UMRR-12 Type 48 User Manual USA CAN 100MHz.docx Version: 1 CONFIDENTIAL AND PROPRIETARY The Information contained in this document shall remain the sole exclusive property of s.m.s, smart microwave sensors GmbH and shall not be disclosed by the recipient to third parties without prior consent of s.m.s, smart microwave sensors GmbH in writing. UMRR-12 Type 48 User Manual USA CAN 100MHz.docx Version 1 I Page 2 of 15 I June 27, 2019 1 Contents 1 Contents .................................................................................................................... 2 2 Abbreviations ............................................................................................................. 3 3 Introduction ............................................................................................................... 4 4 General description .................................................................................................... 5 4.1 Sensor description ................................................................................................ 5 4.2 Transmit Signal .................................................................................................... 5 4.3 General Performance Data .................................................................................... 5 4.4 Software and Firmware Version ............................................................................ 6 5 Hardware .................................................................................................................. 7 5.1 UMRR sensor ....................................................................................................... 7 5.2 Sensor Dimensions ............................................................................................... 8 6 Cables and Connectors ............................................................................................. 10 6.1 Sensor connector ............................................................................................... 10 6.2 CAN data interface ............................................................................................. 11 6.3 CAN-Settings ..................................................................................................... 11 6.4 RS485 data interface .......................................................................................... 12 7 Designated Use ........................................................................................................ 13 8 Compliance for USA and Canada ............................................................................... 14 8.1 Declaration of Conformity for USA ....................................................................... 14 8.1.1 FCC Label .................................................................................................... 14 8.2 Declaration of Conformity for Canada .................................................................. 15 8.2.1 Declaration of Conformity in English .............................................................. 15 8.2.2 Déclaration de conformité en francais ........................................................... 15 8.2.3 Industry Canada (IC) Label ........................................................................... 15 CONFIDENTIAL AND PROPRIETARY The Information contained in this document shall remain the sole exclusive property of s.m.s, smart microwave sensors GmbH and shall not be disclosed by the recipient to third parties without prior consent of s.m.s, smart microwave sensors GmbH in writing. UMRR-12 Type 48 User Manual USA CAN 100MHz.docx Version 1 I Page 3 of 15 I June 27, 2019 2 Abbreviations ADC Analog-to-Digital Converter AFE Analog Front-End CAN Controller Area Network DSP Digital Signal Processing; Digital Signal Processor EEPROM Electrically Erasable Programmable Read-only Memory FMCW Frequency Modulated Continuous Wave GPIO General Purpose Input Output MMIC Monolithic Microwave Integrated Circuit RAM Random Access Memory RS485 Physical communication layer standard EIA RS-485 SPI Serial Peripheral Interface SOC System on Chip UMRR Universal Medium-Range Radar CONFIDENTIAL AND PROPRIETARY The Information contained in this document shall remain the sole exclusive property of s.m.s, smart microwave sensors GmbH and shall not be disclosed by t…
Text truncated - open the document above for the full version.
Page 1 of 7 2014-05-23 Smartmicro Standard Mutual NDA_JBE.doc Non-Disclosure Agreement between „Partner“ and s.m.s. smart microwave sensors GmbH, In den Waashainen 1, 38108 Braunschweig (Germany) „SMS“ Partner and SMS may be referred herein collectively as “Parties” and each may be referred to as “Party”. Preamble (1) The Partner and SMS intend to enter into [discussions about or a project related to Radar Technology] (together the „Project“). (2) During the course of the Project the Parties may exchange information, documents, drawings and other materials which contain trade and business secrets and other Confidential Information. In this context the “Disclosing Party” shall mean the Party disclosing such Confidential Information and “Interested Party” shall mean the Party receiving such Confidential Information. (3) This Agreement sets out the conditions under which the Disclosing Party shall make Confidential Information available to the Interested Party and in particular how Confidential Information should be treated by the Interested Party, its managing directors, employees, staff, authorized persons, advisors and affiliates of Interested Party („Representatives“). Page 2 of 7 2014-05-23 Smartmicro Standard Mutual NDA_JBE.doc Now therefore, the parties agree as follows: § 1 Confidentiality of the Project Until not expressly agreed on a publishing of the Project both Parties agree to keep strictly confidential not only the fact that the Project is existing but also the details of the Project. § 2 Confidential Information Confidential Information for the purposes of this Agreement shall mean all information which is made available to the Interested Party or its Representatives by Disclosing Party verbally, in writing or in any other form, to the extent such information: (1) is clearly marked as Confidential Information, is described as such or is otherwise recognizable as such; (2) is to be regarded as confidential because of its contents; or (3) is derived from Confidential Information which has been provided by Disclosing Party. Confidential Information comprises in particular – but not limited to - any and all IP rights, know-how, computer programs (in source and object code form), data, lab books, designs, devices, processes, and records provided by the Disclosing Party. § 3 Exceptions The term „Confidential Information“ does not include such information which: (1) is or becomes in the public domain or generally available at the time the Interested Party was provided with such information (except by reason of any breach of this Agreement by the Interested Party or its Representatives); (2) was already legitimately in the possession of the Interested Party and not subject to a duty of confidentiality, before the Interested Party received the information from Disclosing Party; or (3) the Interested Party had received from a third party who was entitled to disclose this information without restriction. Page 3 of 7 2014-05-23 Smartmicro Standard Mutual NDA_JBE.doc § 4 Duty of Confidentiality The Parties agree: (1) to keep all Confidential Information strictly confidential; (2) not to use any Confidential Information for purposes other than for the Project; (3) not to disclose any Confidential Information to third parties, with the exception of such of its Representatives who need this information in order to carry on with the Project (need-to-know basis only); and (4) to inform the Disclosing Party whenever § 3 (2) or (3) apply without delay and in writing, stating its sources, that this information was already in its possession. § 5 Protective Measures In order to ensure that the Confidential Information is kept confidential, the Interested Party agrees: (1) to take all reasonable safeguards to prevent disclosure of the Confidential Information; (2) to only make copies of Confidential Information to the extent necessary in order to carry on with the Project; (3) not to use the Confidential Information to compete in any regard with the business of the Disclosing Party; (4) to notify Disclosing Party without delay after becoming aware of an actual or imminent unauthorized use or an actual or imminent unauthorized disclosure of Confidential Information and to take all reasonable measures in order to prevent or terminate any such use or any such disclosure, if necessary with the assistance of Disclosing Party; (5) to have the Representatives execute a NDA that contains confidentiality obligations at least as strict as set forth herein; the Interested Party shall be liable and indemnify Disclosing Party for any unauthorized disclosures by Representatives; Page 4 of 7 2014-05-23 Smartmicro Standard Mutual NDA_JBE.doc (6) to make available at the request of Disclosing Party a list with a) the names and addresses of the persons to whom the Confidential Information has been disclosed and their relationship to the Interested Party; b) the locations in which the Confidential Information is kept; and c) the other protective measures taken by the Interested Party; as well as to grant Disclosing Party a reasonable opportunity during usual business hours to check that the measures and locations set out in the list are complied with. § 6 Disclosure Requirements In the event that the Interested Party or any of its Representatives is subject to a statutory obligation or a legitimate court or official order to disclose Disclosing Party’s Confidential Information, the Interested Party shall: (1) immediately notify Disclosing Party in writing by fax or by e-mail of this obligation and on request assist Disclosing Party as far as possible in protecting the Confidential Information or having it protected through the courts; (2) to the extent that no other protective measures are taken, disclose only such Confidential Information which must be disclosed by reason of the statutory obligation or order and use its best endeavors to ensure that the Confidential Information disclosed is treated as far as possibl…
Text truncated - open the document above for the full version.
Test report no. 19011904 Page 1 of 7 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s, smart microwave sensors GmbH UMRR-12 Type 48 Annex no. 1 External Photographs Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators ANSI C63.4-2014 ANSI C63.10-2013 Test report no. 19011904 Page 2 of 7 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Photographs of the test equipment (EUT) – Front side of unit Test report no. 19011904 Page 3 of 7 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Photographs of the test equipment (EUT) – Rear side of unit Test report no. 19011904 Page 4 of 7 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Photographs of the test equipment (EUT) –Side of unit 1 Test report no. 19011904 Page 5 of 7 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Photographs of the test equipment (EUT) –Side of unit 2 Test report no. 19011904 Page 6 of 7 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Photographs of the test equipment (EUT) –Side of unit 3 Test report no. 19011904 Page 7 of 7 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Photographs of the test equipment (EUT) –Side of unit 4
Test report no. 19011904 Page 1 of 3 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s, smart microwave sensors GmbH UMRR-12 Type 48 Annex no. 4 Label Sample Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators ANSI C63.4-2014 ANSI C63.10-2013 Test report no. 19011904 Page 2 of 3 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Photo of the test equipment (EUT) – Label Location Label Variants UMRR-12 Type 48_100MHz.docx Overview Label Variants UMRR-12 Type 48 FCC ID: W34UMRR1230 IC: 10652A- UMRR1230 Product Label HVIN: UMRR-12 Type 48 PMN: Demo FVN: 006 HVIN: UMRR-12 Type 48 PMN: Stop+Advance FVN: 006 HVIN: UMRR-12 Type 48 PMN: Red Light Enforcement FVN: 006 HVIN: UMRR-12 Type 48 PMN: Forward+ FVN: 006 HVIN: UMRR-12 Type 48 PMN: Enforcement FVN: 006 HVIN: UMRR-12 Type 48 PMN: Generic A FVN: 006
Test report no. 19011904 Page 1 of 3 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s, smart microwave sensors GmbH UMRR-12 Type 48 Annex no. 3 Occupied Bandwidth Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators ANSI C63.4-2014 ANSI C63.10-2013 Test report no. 19011904 Page 2 of 3 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots for the test equipment (EUT) – Measured 20 dB Bandwidth Test report no. 19011904 Page 3 of 3 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots for the test equipment (EUT) – Measured 99 % Bandwidth
Test report no. 19011904 Page 1 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s, smart microwave sensors GmbH UMRR-12 Type 48 Annex no. 11 Spurious emissions Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators ANSI C63.4-2014 ANSI C63.10-2013 Test report no. 19011904 Page 2 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots of the test equipment (EUT) – Spurious emissions 9 kHz – 30 MHz at 3 meter (without correction) 9 kHz – 150 kHz (Antenna 0°) 150 kHz – 30 MHz (Antenna 0°) 9 kHz – 150 kHz (Antenna 90°) 150 kHz – 30 MHz (Antenna 90°) field strength = receiver reading +cable + antenna factor – distance factor Worst case emission below 150 kHz: at 42.35 kHz field strength = 32.95 dBμV + 0.2 dB + 19.1 dB/m -80 dB = -27.75 dBμV/m @ 300 meter Worst case emission above 150 kHz and below 30 MHz: at 7.09 MHz field strength = 20.46 dBμV + 0.3 dB + 19.1 dB/m -40 dB = -0.14 dBμV/m @ 30 meter Test report no. 19011904 Page 3 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots of the test equipment (EUT) – Spurious emissions 30 MHz – 1 GHz at 3 meter Vertical (Peak) Horizontal (Peak) field strength = receiver reading +cable + antenna factor – amplifier gain Worst case emission above 30 MHz and below 1 GHz: at 36.8 MHz field strength = 49.57 dBμV + 0.39 dB + 12.98 dB/m -21.0 dB = 41.94 dBμV/m @ 3 meter Peak Test report no. 19011904 Page 4 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots of the test equipment (EUT) – Spurious emissions 1 GHz – 18 GHz at 3 meter (without correction) Vertical (Peak) Horizontal (Peak) field strength = receiver reading +cable + antenna factor – amplifier gain Worst case emission above 30 MHz and below 1 GHz: at 12.961078 GHz field strength = 34.40 dBμV + 10.11 dB + 43.62 dB/m -36.3 dB = 51.83 dBμV/m @ 3 meter Peak Test report no. 19011904 Page 5 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots of the test equipment (EUT) – Spurious emissions 18 GHz – 24.05 GHz at 3 meter (with all corrections) Vertical Horizontal Test report no. 19011904 Page 6 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots of the test equipment (EUT) – Spurious emissions 24.25 GHz – 26.5 GHz at 3 meter (with all corrections) Vertical Horizontal Test report no. 19011904 Page 7 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots of the test equipment (EUT) – Spurious emissions 26.5 GHz – 30 GHz at 3 meter (with all corrections) Vertical Horizontal Test report no. 19011904 Page 8 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots of the test equipment (EUT) – Spurious emissions 30 GHz – 40 GHz at 3 meter (with all corrections) Vertical Horizontal Test report no. 19011904 Page 9 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots of the test equipment (EUT) – Spurious emissions 40 GHz – 60 GHz at 1 meter (with all corrections) Vertical Horizontal Test report no. 19011904 Page 10 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 3.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Plots of the test equipment (EUT) – Spurious emissions 60 GHz – 90 GHz at 1 meter (with all corrections) Vertical Horizontal Test report no. 19011904 Page 11 of 12 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 Date of issue: 2019-12-03 Date: 2019-11-20 Created: Trepper Re…
Text truncated - open the document above for the full version.
Test report no. 20012094 Page 1 of 39 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 C Date of issue: 2020-09-23 Date: 2019-09-23 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 2.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Test Report acc. to FCC Title 47 CFR Part 15 relating to sms, smart microwave sensors GmbH UMRR-12 Type 48 Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.10-2013 Test report no. 20012094 Page 2 of 39 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 C Date of issue: 2020-09-23 Date: 2019-09-23 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 2.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 MANUFACTURER Manufacturer name sms, smart microwave sensors GmbH Manufacturer’s grantee code W34 Manufacturer’s address In den Waashainen 1 38108 Braunschweig, Germany Phone +49 (0) 531 390 23 0 Fax +49 (0) 531 390 23 599 Email [email protected] TESTING LABORATORY Test engineer Mr. Ralf Trepper Testing laboratory name TÜV NORD Hochfrequenztechnik GmbH & Co. KG Testing laboratory address LESKANPARK, Gebäude 10 Waltherstr. 49-51 51069 Köln, Germany Phone +49 221 8888 950 Email [email protected] RELEVANT STANDARD Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart Subpart C – Intentional Radiators – Section 15.245 Measurement procedure ANSI C63.10-2013 EQUIPMENT UNDER TEST (EUT) Equipment category Field Disturbance Sensor Trade name smartmicro Type designation UMRR-12 Type 48 Serial no. 0x0002FBAF Variants --- Test report no. 20012094 Page 3 of 39 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 C Date of issue: 2020-09-23 Date: 2019-09-23 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 2.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 1. Test results Clause Requirements headline FCC Rule Test result 8.1 Antenna requirement §15.203 Pass Fail N.t. * 8.2 Restricted bands of operation §15.205 Pass Fail N.t. * 8.3 Conducted limits §15.207 Pass Fail N.t. * 8.4 Radiated emission limits, general requirements §15.209 Pass Fail N.t. * 8.5 Field strength of fundamental and harmonics §15.245 Pass Fail N.t. * 8.6 Bandwidth §15.245 Pass Fail N.t. * 8.7 Band edge measurement §15.245 Pass Fail N.t. * * Not tested The equipment passed all the conducted tests Yes No Signature Name Mr. Ralf Trepper Mr. Abdelouahid Ftouhi Designation RF Test Engineer Laboratory-Manager Date of issue 2020-09-23 2020-09-23 Test report no. 20012094 Page 4 of 39 EUT: UMRR-12 Type 48 FCC ID: W34UMRR1230 FCC Title 47 CFR Part 15 C Date of issue: 2020-09-23 Date: 2019-09-23 Created: Trepper Reviewed: Ftouhi Released: Hittig-Rademacher Vers. No. 2.19 TÜV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebäude 10, Waltherstr. 49-51, 51069 Köln, Germany Tel.: +49 221 8888950 Table of contents 1. Test results ........................................................................................................................................................ 3 2. Introduction ...................................................................................................................................................... 5 3. Testing laboratory ............................................................................................................................................ 5 4. Applicant .......................................................................................................................................................... 6 5. Product and product documentation ................................................................................................................. 6 6. Conclusions, observations and comments........................................................................................................ 7 7. Operational description ..................................................................................................................................... 8 8. Compliance assessment ..................................................................................................................................... 9 8.1 Antenna requirement ....................................................................................................................................... 9 8.1.2 Result .................................................................................................................................................... 9 8.2 Restricted bands of operation........................................................................................................................... 10 8.2.1 Regulation ............................................................................................................................................. 10 8.2.2 Result .................................................................................................................................................... 11 8.3 Conducted limits ............................................................................................................................................ 12 8.3.1 Regulation ............................................................................................................................................. 12 8.3.2 Test procedures ..................................................................................................................................... 12 8.3.3 Result .................................................................................................................................................... 13 8.4 Radiated emission limits, general require…
Text truncated - open the document above for the full version.
Test report no. 19011904 Page 1 of 10 EUT: UMRR-12 Type 48 …
Text truncated - open the document above for the full version.
In den Waashainen 1 Braunschweig · Germany
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.245 | 24.07 GHz - 24.18 GHz | - |

UMRR-12 Type 48 B
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Automotive radar sensor DRVEGRD 169
Equipment Class
VRD - Part 95 Vehicular Radar Systems
TRUGRD Stream
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
UMRR-12 Type 48
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
UMRR-96 Type 153
Equipment Class
VRD - Part 95 Vehicular Radar Systems