Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TRIGNO Wireless System User’s Guide September 2012 Edition PM-W01 Copyright © 2012 by Delsys Incorporated Specifications and procedures outlined in this document are subject to change without notice. Delsys Logo, EMGworks, and Myomonitor are Registered Trademarks of Delsys Incorporated. MAN-012-2-4 TM Table of Contents Table of Contents ....................................................................... 3 Important Information ................................................................. 5 Intended Use........................................................................ 5 Contraindications ................................................................. 5 Technical Service and Support ............................................ 5 Warnings and Precautions ................................................... 6 Device Information ............................................................... 7 Disclaimer ............................................................................ 9 Limited Warranty .................................................................. 9 System Requirements.......................................................... 9 TrignoTM Wireless EMG System Overview ............................. 10 Wireless EMG Sensor........................................................ 10 Sensor LED Indicator Status ....................................... 11 Base Station....................................................................... 11 Power Supply ..................................................................... 12 Getting Started with the TrignoTM System............................... 13 Software Installation........................................................... 13 Powering the Base Station................................................. 13 Connecting the Base Station ............................................. 13 Charging the Sensors ........................................................ 14 Acquiring Data in EMGworks Acquisition........................... 15 Sampling the Analog Outputs ............................................ 15 Digital Outputs (Trigno SDK) ............................................. 15 Using the Wireless EMG Sensors ............................................ 16 Orienting the EMG Sensors on the Skin ............................ 16 Cleaning the Sensor Site ................................................... 16 Applying the Trigno Adhesive Skin Interfaces ................... 16 Turning the Sensors ON .................................................... 17 Trigno Sensor Status Console........................................... 17 Turning the Sensors Off ..................................................... 18 Using the Analog Outputs......................................................... 19 Analog Output Connectors................................................. 19 Channels 1-16, EMG Signals ...................................... 19 Channels 1-64, all Signals ........................................... 19 Screw Terminal Connections....................................... 20 Trigno Control Utility Software ........................................... 21 Installing the Software ................................................. 21 Launching the Software ............................................... 21 Configuration Options for Trigno System ................................. 23 Accessing Configuration Options ....................................... 23 Trigno System Information ................................................. 24 Trigno System Settings ...................................................... 25 Mode Control (Analog Output Software Only) ................... 26 Test Panel .......................................................................... 26 Additional Sensor Information .................................................. 28 Sensor Pairing ................................................................... 28 Sensor Factory Calibration ................................................ 29 Smart Sensors ................................................................... 30 Sensor Modes in EMGworks ............................................. 30 Using Tandem Trigno Systems ................................................ 31 Initial Connectivity........................................................ 31 Communication Frequencies ....................................... 31 Synchronization ........................................................... 31 User Interface .............................................................. 32 Maintenance and Care ............................................................. 33 Trigno Sensors................................................................... 33 Trigno Base Station ........................................................... 33 Specifications ........................................................................... 35 Trigno Sensors................................................................... 35 Trigno Recharging Base Station ........................................ 37 Appendix I................................................................................. 39 Mains Isolation ................................................................... 39 Appendix II................................................................................ 40 DC-A22 Unterminated Output Cable ................................. 40 Installation .......................................................................... 40 DC-A22 Conductor Assignments ....................................... 41 5 Important Information Intended Use The Trigno TM Wireless EMG Systems are battery-powered biofeed- back devices intended for research, investigational and scholarship purposes only. Delsys ® products are not intended for measurement purposes or for use in the treatment and diagnosis of disease. Inter- pretation of the EMG signal by a qualified professional is required. Rx ONLY Contraindicatio…
Text truncated - open the document above for the full version.
P.O. Box 15734 | Boston, MA 02215 USA | phone: 617-236-0599 | fax: 617-236-0549 | email: [email protected] | www.delsys.com August 29, 2012 RE: FCC Authorization FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization We, Delsys Inc., the undersigned, Hereby authorize Bay Area Compliance Laboratory Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratory Corporation on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This authorization is valid until further written notice from the applicant. Sincerely, Gianluca De Luca Vice President of Product Development Delsys Inc. 650 Beacon St., Floor 6 Boston MA 02215
P.O. Box 15734 | Boston, MA 02215 USA | phone: 617-236-0599 | fax: 617-236-0549 | email: [email protected] | www.delsys.com Manufacturer’s Declaration and Request for Permanent Confidentiality August 29, 2012 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: W4P-SP-W05 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Delsys Inc. hereby requests long-term confidential treatment of information accompanying this application as outlined below: (1) Circuit Schematics of the EUT (2) All Internal EUT Photographs (3) Block Diagrams (4) EUT Operation Description The above materials contain proprietary and confidential information not customarily released nor readily available to the public. This is particularly true for the circuit schematics, the block diagrams and the internal photographs of the EUT since the device is hermetically sealed and cannot be disassembled by non-destructive means. In addition, the EUT Operation Description provides details of our products’ communication strategy, which we consider to be highly confidential. The public disclosure of these materials provides unjustified benefits to our competitors in the marketplace, and no IP protection from any party wishing to do us harm. Sincerely, Vice President of Product Development [email protected] 617 236 0599 Delsys Inc. 650 Beacon St., Floor 6 Boston MA 02215
Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] External EUT Photographs Top of EUT Bottom View: Side Views:
PROPRIETARY & CONFIDENTIAL INFORMATION DELSYS INC 1/1 Sensor FCC-IC Label Location Document Information Filename: Sensor FCC-IC Label Location.docx 10/31/2012 Drawing of Label This is a plastic label with permanent adhesive. 0.63” 16mm 0.26” 6.6mm
Radiometrics Midwest Corporation (815) 293-0772 – www.radiomet.com Page 1 of 18 Electromagnetic Compatibility Test Report Tests Performed on a Delsys, Inc. Trigno Wireless Sensor, Model SP-W05 Radiometrics Document RP-7251 Product Detail: FCC ID: W4P-SP-W05 IC: 8138A-SPW05 Equipment type: 2.4 GHz Transmitter Test Standards: US CFR Title 47, Chapter I, FCC Part 15 Subpart C FCC Part 15 CFR Title 47: 2012 Industry Canada RSS-210, Issue 7: 2007 as required for Category I Equipment This report concerns: Original Grant for Certification FCC Part 15.249 Tests Performed For: Test Facility: Delsys, Incorporated Street Address: 650 Beacon St., Floor 6 Boston, MA 02215 Mailing Address: PO Box 15734 Boston, Massachusetts 02215 United States Radiometrics Midwest Corporation 12 East Devonwood Romeoville, IL 60446 Test Date(s): (Month-Day-Year) April 13 thru 20, 2012 Document RP-7251 Revisions Rev. Issue Date Affected Pages Revised By 0 September 6, 2012 1 September 26, 2012 All Joseph Strzelecki RADIOMETRICS MIDWEST CORPORATION - EMC Test Report Testing of the Delsys, Inc., Model SP-W05, Trigno Wireless Sensor RP-7251 Rev. 1 Page 2 of 18 Table of Contents 1 ADMINISTRATIVE DATA ....................................................................................................................3 2 TEST SUMMARY AND RESULTS ......................................................................................................3 2.1 RF Exposure Compliance Requirements ......................................................................................3 3 EQUIPMENT UNDER TEST (EUT) DETAILS .....................................................................................4 3.1 EUT Description ............................................................................................................................4 3.1.1 FCC Section 15.203 & RSS-GEN Antenna Requirements.....................................................4 3.2 Related Submittals ........................................................................................................................4 4 TESTED SYSTEM DETAILS ...............................................................................................................4 4.1 Tested System Configuration........................................................................................................4 4.2 Special Accessories ......................................................................................................................4 4.3 Equipment Modifications ...............................................................................................................4 5 TEST SPECIFICATIONS AND RELATED DOCUMENTS ..................................................................5 6 RADIOMETRICS’ TEST FACILITIES ..................................................................................................5 7 DEVIATIONS AND EXCLUSIONS FROM THE TEST SPECIFICATIONS .........................................6 8 CERTIFICATION .................................................................................................................................6 9 TEST EQUIPMENT TABLE .................................................................................................................6 10 TEST SECTIONS ..............................................................................................................................6 10.1 Time of Occupancy (Dwell Time) ................................................................................................6 10.2 Occupied Bandwidth ...................................................................................................................7 10.2.1 Bandwidth Plots ....................................................................................................................8 10.3 Band-edge Compliance of RF Conducted Emissions ...............................................................11 10.4 Average & Peak RF Power .......................................................................................................13 10.5 RF Radiated Emissions.............................................................................................................14 10.5.1 Radiated Emissions Field Strength Sample Calculation ....................................................14 10.5.2 Spurious Radiated Emissions Test Results........................................................................15 10.6 Unintentional Emissions (Receive Mode) .................................................................................18 Notice: This report must not be reproduced (except in full) without the written approval of Radiometrics Midwest Corporation. RADIOMETRICS MIDWEST CORPORATION - EMC Test Report Testing of the Delsys, Inc., Model SP-W05, Trigno Wireless Sensor RP-7251 Rev. 1 Page 3 of 18 1 ADMINISTRATIVE DATA Equipment Under Test: A Delsys, Inc., Trigno Wireless Sensor Model: SP-W05, Serial Number: none This will be referred to as the EUT in this Report Date EUT Received at Radiometrics: (Month-Day-Year) Test Date(s): (Month-Day-Year) April 13, 2012 April 13 thru 20, 2012 Test Report Written By: The Test Witnessed by: Joseph Strzelecki Senior EMC Engineer The Test was not Witnessed by Personnel from Delsys, Inc. Radiometrics’ Personnel Responsible for Test: Test Report Approved By Joseph Strzelecki Senior EMC Engineer NARTE EMC-000877-NE Chris W. Carlson Director of Engineering NARTE EMC-000921-NE 2 TEST SUMMARY AND RESULTS The EUT (Equipment Under Test) is a Trigno Wireless Sensor, Model Trigno Wireless EMG System, manufactured by Delsys, Inc. The detailed test results are presented in a separate section. The following is a summary of the test results. Emissions Tests Results Environmental Phenomena Frequency Range FCC Section RSS-210 Section Test Result 20 dB Bandwidth Test 2400 to 2483 MHz 15.249 A2.9 Pass Radiated Emissions 30 MHz to 25 GHz 15.249 A2.9 Pass No Conducted emissions were performed since …
Text truncated - open the document above for the full version.
Authorized Agent: Radiometrics Midwest Corporation (815) 293-0772 – [email protected] Test Setup Photographs Photographs of Radiated Emissions Test Setup Photograph of Antenna Conducted Emissions Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.47 GHz | - |

Wireless EMG Hip Module
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter