
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Confidential & Proprietary 1/27 SMDR-NH124(Remote Unit) User Manual Confidential & Proprietary 2/27 REVISION HISTORY Version Issue Date No. of Pages Initials Details of Revision Changes V 1.0 July. 14, 2015 Original Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD Tehcnology, Inc. website at www.st.co.kr or send email at [email protected] This manual is produced by Global Business Division Business Team 1. Printed in Korea. Confidential & Proprietary 3/27 Contents Section1 Safety & Certification Notice ................................................................... 5 Section2 System Overview ..................................................................................... 9 2.1 Purpose ......................................................................................................... 10 2.2 SMDR-NH124 ................................................................................................ 11 2.3 Dimension ..................................................................................................... 12 Section3 System Installation ................................................................................ 13 3.1 ROU Installation ........................................................................................... 13 3.1.1 ROU Enclosure installation ................................................................... 13 3.1.2 ROU Power Cabling ............................................................................... 17 3.1.3 Optical Cabling ...................................................................................... 18 3.1.4 GND Terminal Connection .................................................................... 19 3.1.5 Coaxial cable and Antenna Connection .............................................. 20 3.1.6 Insertion of RDU..................................................................................... 20 3.1.7 RDU Specifications Per band ............................................................... 21 Confidential & Proprietary 4/27 Contents of Figure Figure 3.1 – ROU Outer Look ........................................................................ 12 Figure 3.2 – How to install ROU ..................................................................... 14 Figure 3.3 – Dimension used to install ROU on the WALL ............................. 14 Confidential & Proprietary 5/27 Section1 Safety & Certification Notice Confidential & Proprietary 6/27 “Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.” - Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. - The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters. - When working with units outdoors, make sure to securely fasten the door or cover in an open position to prevent the door from slamming shut in windy conditions.. - Use this unit only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. - Any DAS system or Fiber BDA will generate radio (RF) signals and continuously emit RF energy. Avoid prolonged exposure to the antennas. SOLiD recommends maintaining a 200cm minimum clearance from the antenna while the system is operating. - Do not operate this unit on or close to flammable materials, as the unit may reach high temperatures due to power dissipation. - Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives on the DAS equipment. Alcohol may be used to clean fiber optic cabling ends and connectors. - To prevent electrical shock, switch the main power supply off prior to working with the DAS System or Fiber BDA. Never install or use electrical equipment in a wet location or during a lightning storm. - Do not look into the ends of any optical fiber or directly into the optical transceiver of any digital unit. Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating transceiver or optical fiber connector to avoid the potential of radiation exposure. - Allow sufficient fiber length to permit routing without severe bends. - For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily accessible. - A readily accessible disconnect device shall be incorporated external to the equipment. Confidential & Proprietary 7/27 - This power of this system shall be supplied through wiring installed in a normal building. If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device - Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote. Any equipment attached to this device not meeting this standard may cause degradation and unwanted signals in the bi-directional system. All components connected to this device must operate in the frequency range of this device. - Only 50 ohm rated antennas, cables and passive components operating from 150 - 3 GHz shall be used with this device. - The following notice: "The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 d…
Text truncated - open the document above for the full version.
SOLiD, Inc. 10,9th Floor, SOLiD Space 220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 463-400 Tel : +82-31-627-6290 Fax : +82-31-627-6209 ____________________________________________________________________________ Date: July 10, 2015 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 Subject: Letter for Warning Label Message FCC ID: W6U25TDD To Whom It May Concern: Warning label messages will be also shown in online and point-of-sale marketing materials and on outside packaging of device per KDB 935210 D02 in Section IV clause (d). Best Regards
SOLiD, Inc. 10,9th Floor, SOLiD Space 220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 463-400 Tel : +82-31-627-6290 Fax : +82-31-627-6209 ____________________________________________________________________________ Date: July 10, 2015 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 RE: Request of Confidentiality for FCC ID: W6U25TDD To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), and Section 552 (b) (4) of the Freedom of Information Act, SOLiD, Inc. hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give SOLiD, Inc. temporary confidentiality of commercially sensitive information prior to product release. The requested Confidential and Temporary Confidential exhibits are listed as follows: CONFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description CONFIDENTIAL 1 Block Diagram 2 Operational Descriptions 3 Parts Lists and Tune-Up Procedure 4 Schematics SHORT-TERM CONFIDENTIAL 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 User’s Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. SOLiD, Inc.
FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/ 8 EXTERNAL PHOTOGRAPHS FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/ 8 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/ 8 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/ 8 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/ 8 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/ 8 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/ 8 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 8/ 8
1. RDU 25TDD Label RDU MODULE (25TDD) MODEL NAME : RDU 25TDD FCC ID : W6U25TDD IC : 9354A-25TDD ID Label #1 WARNING Label WARNING Label Label Location ID Label #1
FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/ 12 INTERNAL PHOTOGRAPHS FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/ 12 Bare PCB FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/ 12 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/ 12 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/ 12 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/ 12 SMT PCB FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/ 12 . FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 8/ 12 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 9/ 12 FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 10/12 Assembly FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 11/12 Exterior picture (Completed assembly) FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 12/12
74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL: +82-31-645-6300 FAX: +82-31-645-6401 F-01P-02-014 (Rev.00) HCT Co.,LTD. FCC / IC REPORT Certification FCC ID : W6U25TDD IC: : 9354A-25TDD APPLICANT : SOLiD, Inc FCC/IC Model Name: RDU 25TDD EUT Type: RDU Module (25 TDD) FCC Frequency Ranges: 2497.8 MHz ~ 2565.4 MHz (LB) 2574.1 MHz ~ 2611.9 MHz (MB) 2619.8 MHz ~ 2687.4 MHz (UB) IC Frequency Ranges: 2500.0 MHz ~ 2565.4 MHz (LB) 2574.1 MHz ~ 2611.9 MHz (MB) 2619.8 MHz ~ 2688.4 MHz (UB) Conducted Output Power: 1 W ( 30 dBm) Date of Test : June 29, 2015 ~ July 16, 2015 FCC Rules Part(s): CFR 47, Part 27 IC Rules : RSS-Gen (Issue 4, November 2014), RSS-131 (Issue 2, July 2003) Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Part 27 of the FCC Rules under normal use and maintenance. Report prepared by : Yong Hyun Lee Engineer of RF Team Report approved by : Sang Jun Lee Manager of RF Team This report only responds to the tested sample and may not be reproduced, except in full, without written approval of the HCT Co., Ltd. Applicant Name: SOLiD, Inc Address: 10, 9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, South Korea Date of Issue: July 22, 2015 Test Site/Location: HCT CO., LTD., 74, Seoicheon-ro 578beon-gil, Majang- myeon, Icheon-si, Gyeonggi-do, Korea Report No.: HCT-R-1507-F020-1 HCT FRN: 0005866421 IC Recognition No.: 5944A-3 Report No.: HCT-R-1507-F020-1 MODEL: RDU 25TDD Page 2 of 63 F-01P-02-014 (Rev.00) HCT CO., LTD FCC ID: W6U25TDD / IC: 9354A-25TDD Report Revision TEST REPORT NO. DATE DESCRIPTION HCT-R-1507-F020 July 17, 2015 - First Approval Report HCT-R-1507-F020-1 July 22, 2015 - Modified a typo - Revised Emission limits Report No.: HCT-R-1507-F020-1 MODEL: RDU 25TDD Page 3 of 63 F-01P-02-014 (Rev.00) HCT CO., LTD FCC ID: W6U25TDD / IC: 9354A-25TDD Table of Contents 1. CLIENT INFORMATION ________________________________________________________________ 4 2. FACILITIES AND ACCREDITATIONS _____________________________________________________ 5 2.1. FACILITIES ......................................................................................................................................... 5 2.2. EQUIPMENT ....................................................................................................................................... 5 3. TEST SUMMARY _____________________________________________________________________ 6 3.1. STANDARDS ...................................................................................................................................... 6 3.2. MODE OF OPERATION DURING THE TEST .................................................................................... 6 4. STANDARDS ENVIRONMENTAL TEST CONDITIONS _______________________________________ 7 5. TEST EQUIPMENT ___________________________________________________________________ 8 6. RF OUTPUT POWER__________________________________________________________________ 9 7. OCCUPIED BANDWIDTH _____________________________________________________________ 21 8. PASSBAND GAIN AND BANDWIDTH & Out of Band Rejection ______________________________ 27 9. SPURIOUS AND HARMONIC EMISSION AT ANTENNA TERMINAL __________________________ 31 10. RADIATED SPURIOUS EMISSIONS ___________________________________________________ 58 11. FREQUENCY STABILITY OVER TEMPERATURE AND VOLTAGE VARIATIONS ________________ 61 Report No.: HCT-R-1507-F020-1 MODEL: RDU 25TDD Page 4 of 63 F-01P-02-014 (Rev.00) HCT CO., LTD FCC ID: W6U25TDD / IC: 9354A-25TDD 1. CLIENT INFORMATION The EUT has been tested by request of Company SOLiD, Inc 10, 9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, South Korea ■ FCC ID: W6U25TDD ■ IC: 9354A-25TDD ■ APPLICANT: SOLiD, Inc ■ EUT Type: RDU Module (25 TDD) ■ FCC/ IC Model: RDU 25TDD ■ FCC Frequency Ranges: 2497.8 MHz ~ 2565.4 MHz (LB) 2574.1 MHz ~ 2611.9 MHz (MB) 2619.8 MHz ~ 2687.4 MHz (UB) ■ IC Frequency Ranges: 2500.0 MHz ~ 2565.4 MHz (LB) 2574.1 MHz ~ 2611.9 MHz (MB) 2619.8 MHz ~ 2688.4 MHz (UB) ■ Conducted Output Power: 1 W ( 30 dBm) ■ Antenna Gain(s) : Manufacturer does not provide an antenna. ■ FCC Rules Part(s): CFR Title 47 Part 27 ■ IC Rules Part(s): RSS-Gen (Issue 4, November 2014), RSS-131 (Issue 2, July 2003) ■ Measurement standard(s): ANSI/TIA-603-C-2004, KDB 971168 D01 v02r02 KDB 935210 D02 v03, KDB 935210 D05 v01, RSS-131 (Issue 2, July 2003) ■ Place of Tests: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea. (IC Recognition No. : 5944A-3) Report No.: HCT-R-1507-F020-1 MODEL: RDU 25TDD Page 5 of 63 F-01P-02-014 (Rev.00) HCT CO., LTD FCC ID: W6U25TDD / IC: 9354A-25TDD 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea. The site is constructed in conformance with the requirements of ANSI C63.4. (Version :2003) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated February 28, 2014 (Registration Number: 90661) 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of Linearly polarized antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre- selectors and quasi-peak detectors are used to perform radiated measurements. Calibrated wideband preamplifiers, coaxial cables, and coa…
Text truncated - open the document above for the full version.
FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/ 8 TEST SETUP PHOTOGRAPHS FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/ 8 ■ Conducted Downlink-1 Test Setup Photo FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/ 8 ■ Conducted Downlink-2 Test Setup Photo FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/ 8 ■ Conducted Downlink-3 Test Setup Photo FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/ 8 ■ Radiated Test Setup Photo( AC Front) FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/ 8 ■ Radiated Test Setup Photo( AC Back) FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/ 8 ■ Radiated Test Setup Photo( DC Front) FCC ID : W6U25TDD HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 8/ 8 ■ Radiated Test Setup Photo( DC Back)
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 27 | 2.50 GHz - 2.69 GHz | 1.086 W | 17M9G7D | Amp |
Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)nGENESIS
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)nGENESIS
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)nGENESIS
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)nGENESIS
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)