FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SOLiD, Inc./
  3. W6U70L21A

W6U70L21ASingle Carrier DAS

SOLiD, Inc.
Single Carrier DAS - FCC ID W6U70L21A - SOLiD, Inc.
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Jan 23, 2013
Application Purpose
Original Equipment
Date of Application
Jan 23, 2013
Equipment Note
Single Carrier DAS
Frequency Range
728.00000000 - 757.00000000
Company
SOLiD, Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Confidential & Proprietary 1/115 SC‐DAS SC‐DAS Installation and Operation Manual Document Reference: Version: V4.0 Document Status: Release 3 Issue Date: January. 07, 2013 Author: Kyung Eun Han Department: R&D Division Team 3 Authorizing Manager: Young shin Yeo Confidential & Proprietary 2/115 SC‐DAS REVISION HISTORY Version Issue Date No. of Pages Initials Details of Revision Changes V 1.0 April. 11, 2011 Original V 2.0 Dec. 08,2011 Add Sprint band V 3.0 Jan. 06,2012 Add Sprint band V 4.0 Jan. 07,2013 Add VzW (MRU MIMO) band Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD, Inc. website at www.st.co.kr or send email at [email protected] This manual is produced by Global Business Division Business Team 1. Printed in Korea. Confidential & Proprietary 3/115 SC‐DAS Contents Section1 Safety & Certification Notice ...................................................................... 11 Section2 System Overview ....................................................................................... 13 2.1 General overview ............................................................................................ 14 2.2 System overview ............................................................................................. 16 Section3 System Specifications ................................................................................ 19 3.1 System specifications ...................................................................................... 20 3.1.1 Physical Specifications .............................................................................. 20 3.1.2 Optical wavelength and Laser power......................................................... 21 3.1.3 Environmental specifications .................................................................... 21 3.1.4 Available Frequency Bands ........................................................................ 21 3.1.5 Band Specifications ................................................................................... 22 Section4 System Configuration and Functions ........................................................... 23 4.1 BIU (BTS Interface Unit) .................................................................................. 24 4.1.1 BIU Specifications .................................................................................................... 24 4.1.2 BIU block diagram ................................................................................................... 25 4.1.3 BIU assemblies ........................................................................................................ 25 4.1.4 Sub Assembly Description ........................................................................................ 26 4.1.5 BIU front/rear panel overview .................................................................................. 30 4.2 ODU (Optic distribution Unit) .......................................................................... 33 4.2.1 ODU specifications................................................................................................... 33 4.2.2 ODU block diagram ................................................................................................. 34 4.2.3 ODU assemblies ....................................................................................................... 34 4.2.4 Sub Assembly description ......................................................................... 35 4.2.5 ODU front/rear panel overview ................................................................................ 36 4.2.6 ODU Interface with BIU ............................................................................................ 38 4.3 OEU (Optic Expansion Unit) ............................................................................. 40 4.3.1 Specifications of OEU ............................................................................................... 40 Confidential & Proprietary 4/115 SC‐DAS 4.3.2 OEU block diagram ................................................................................... 41 4.3.3 OEU assemblies ....................................................................................................... 41 4.3.4 Sub Assembly description ........................................................................................ 42 4.3.5 OEU front/rear panel overview .................................................................. 45 4.4 ROU (Remote Optic Unit) ................................................................................ 46 4.4.1 ROU specifications .................................................................................... 47 4.4.2 ROU block diagram ................................................................................... 48 4.4.2.1 Combination of MRU 1900PCS+850C/ARU 700LTE+AWS‐1 ........................... 48 4.4.2.2 Combination of MRU 1900PCS/ARU 900I+800I ........................................... 48 4.4.2.3 Combination of MRU 700LTE+AWS‐1 .......................................................... 49 4.4.2.4 Combination of MRU 1900PCS+850C/ARU 700LTE+AWS‐1 ........................... 49 4.4.2.5 Combination of MRU 1900PCS/ARU 900I+800I ........................................... 50 4.4.2.6 Combination of MRU 700LTE+AWS‐1 .......................................................... 51 4.4.3 Sub Assembly description ......................................................................... 53 4.4.4 Bottom of ROU ......................................................................................... 55 4.4.5 Top of ROU ............................................................................................... 57 4.4.5.1 Combinat…

Text truncated - open the document above for the full version.

Users Manual

Confidential & Proprietary 58/115 SC‐DAS Item Description Remark 1. RF Port Terminal for Low RF port to connect between MRU and ARU RF Terminal for HIGH RF port to connect between MRU and ARU RF 2. ANT Port Terminal for RF port to connect to antenna 3. Optic Port Termnial for Optical port to connect with fiber cable The fiber connector type is SC/APC Confidential & Proprietary 59/115 SC‐DAS Section5 System Installation & Operation 5.1 BIU Installation 5.2 ODU Installation 5.3 ROU Installation 5.4 OEU Installation Confidential & Proprietary 60/115 SC‐DAS This chapter describes how to install each unit and corresponding fiber cables, along with power cabling method. In detail, the chapter describes how to install shelves or enclosures of each unit, Power Cabling method , Optic Cabling and RF Interface. Furthermore, by showing power consumption of modules installed in each unit, a the Power Cabling budget is easily determined. Last, it describes the quantity of components of modules to be installed in each unit along with an expansion method. 5.1 BIU Installation 5.1.1 BIU Shelf Installation Generally, the BIU is installed in a 19” standard rack. This unit has handles on each side for easy placement. With two mounting holes on each side, you can firmly fix the unit into a 19” rack. Figure 5.1 – RACK Installation BIU has the following components: No. Unit Description Remark Common Part Shelf Including Main Board, 19”,5U 1EA MPSU Operate ‐48Vdc Input 1EA MCPU With Ethernet Port and USB Port 1EA Power Cable ‐48Vdc Input with two lug terminal 1EA SISO Slot MCDU ‐ 1EA MDBU Two among MDBU Up to 2EA MIMO Slot MCDU ‐ 1EA MDBU Two among MDBU Up to 2EA Basically, the frame of the BIU has slots equipped with an MPSU to supply devices with poweran Confidential & Proprietary 61/115 SC‐DAS MCPU to query and control state of each module and a Power Cable to supply power from external rectifiers. In addition, ther are slots for the MDBUs which provide services for desired band (Optional) and the MCDU to combine and divide TX/RX signals for each SISO and MIMO slots 5.1.2 BIU Power Cabling BIU requires ‐48VDC input power. Connect DC cable from the power supply to the Terminal Block seen at the rear of BIU. Terminal Color of cable Description Remark ‐48V Blue color ‐ GND Black color ‐ NC Not Connected ‐ Before connecting the power terminal, you need to connect "+" terminal of the DVM probe with the GND terminal and then connect "–" terminal with ‐48V to see if “‐48Vdc” voltage is present. After confirming this, connect the power terminal with the terminal of the terminal block seen below. Figure 5.2 – Power interface diagrm Note that BIU does not operate if the "+" terminal and the "–" terminal of the ‐48V power are reversed. When you connect ‐48V power to the BIU, use the ON/OFF switch of the MPSU located at the front Confidential & Proprietary 62/115 SC‐DAS of BIU to check the power. Figure 5.3 – PSU LED indicator information Power Switch LED Description O ON Abnormal, Not supply Power ‐48Vdc Normal supply power ‐48Vdc DC ALM Normal Status Failure of output Power I ON Normal Status DC ALM Confidential & Proprietary 63/115 SC‐DAS 5.1.3 BIU/RF interface The BIU can be connected with a Bi‐Directional Amplifier or Base Station Tranceiver. To connect the BIU with a BDA, you need to use a duplexer or a circulator to separate TX/RX signals from each other. The BIU can feed external TX/RX signals from the Back Plane. Using a dual band MDBU, the BIU can easily accomodate all frequency bands. As seen in the table below, the MDBU is divided into Single and Dual Bandmodules and each unit can be connected with two carrier signals per band. At the rear of the MDBU, 4 ports represent the inputs for the frequency bands. The following table shows signals to be fed to corresponding ports: No Unit naming Description In/out RF Port TX RX 1 1900P+850C MDBU Dual Band 1900P:2Port 850C:2Port Port#1 1900P TX(1930~1995MHz) 1900P RX(1850~1915MHz) Port#2 1900P TX(1930~1995MHz) 1900P RX(1850~1915MHz) Port#3 850C TX(869~894MHz) 850C RX(824~849MHz) Port#4 850C TX(869~894MHz) 850C RX(824~849MHz) 2 700LTE+AWS‐1 MDBU Dual Band 700LTE:2Port AWS‐1:2Port Port#1 700LTE TX(728~756MHz) 700LTE RX(698~716MHz, 777~787MHz) Port#2 700LTE TX(728~756MHz) 700LTE RX(698~716MHz, 777~787MHz) Port#3 AWS‐1 TX(2110~2155MHz) AWS‐1 RX(1710~1755MHz) Port#4 AWS‐1 TX(2110~2155MHz) AWS‐1 RX(1710~1755MHz) 3 1900P MDBU Single Band 1900P:2Port Port#1 1900P TX(1930~1995MHz) 1900P RX(1850~1915MHz) Port#2 1900P TX(1930~1995MHz) 1900P RX(1850~1915MHz) 4 900I+800I MDBU Dual Band 900I:2Port 800I:2Port Port#1 900I TX(935~940MHz) 900I RX(896~901MHz) Port#2 900I TX(925~940MHz) 900I RX(896~901MHz) Port#3 800PS TX(851~869MHz) 800PS RX(806~869MHz) Port#4 800PS TX(851~869MHz) 800PS RX(806~869MHz) 5 1900P+AWS‐1 MDBU Dual Band 1900P:2Port AWS‐1:2Port Port#1 1900P TX(1930~1995MHz) 1900P RX(1850~1915MHz) Port#2 1900P TX(1930~1995MHz) 1900P RX(1850~1915MHz) Port#3 AWS‐1 TX(2110~2155MHz) AWS‐1 RX(1710~1755MHz) Port#4 AWS‐1 TX(2110~2155MHz) AWS‐1 RX(1710~1755MHz) 6 700PS+800PS Dual Band Port#1 700PS TX(763~775MHz) 700PS RX(793~805MHz) On the loadmap Confidential & Proprietary 64/115 SC‐DAS MDBU 700PS:2Port 800PS:2Port Port#2 700PS TX(763~775MHz) 700PS RX(793~805MHz) Port#3 800PS TX(851~869MHz) 800PS RX(806~869MHz) Port#4 800PS TX(851~869MHz) 800PS RX(806~869MHz) 7 900I MDBU Single Band 900I:2Port Port#1 900I TX(929~941MHz) 900I RX(896~902MHz) Port#2 900I TX(929~941MHz) 900I RX(896~902MHz) 8 VHF+UHF MCDU Dual Band VHF+UHF : 1Port Port#1 VHF Tx(136~174MHz) VHF Rx(136~174MHz) UHF Tx(380~512MHz) UHF Rx(380~512MHz) At the rear of BIU, Tx input and Rx output ports are seen for each MDBU. The name of all the ports are silk screened as "#1, #2, #3 and #4." From the table above, you need to feed correct signals tothe input and output ports of the corresponding MDBU. Figure 5.4 – BIU RF interface diagram For each port, TX and RX signals are separated from each other. It is not necessary to terminat…

Text truncated - open the document above for the full version.

Cover Letter(s)

SOLiD, Inc. 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, Korea Tel: +82-31-627-6292, Fax: +82-31-627-6209 EMCCert DR. RAŠEK GmbH Date: January 08 , 2013 Stoernhofer Berg 15 91364 Unterleinleiter GERMANY This authorization is valid until further written notice from the applicant. Sincerely Yours,

Cover Letter(s)

SOLiD, Inc. 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, Korea Tel: +82-31-627-6292, Fax: +82-31-627-6209 Date: January 08 , 2013 FCC Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Attention : Application Examiner / Reviewing Engineer Subject : Request for confidentiality per Section 0.459 of FCC Rules Applicant : SOLiD, Inc. FCC ID : W6U70L21A To whom it may concern, Request is hereby submitted, SOLiD, Inc., to withhold from public review certain portions of the application for equipment certification for the referenced FCC identifier. In particular, the following sections of the application and report are requested to be kept confidential: Schematics / Block Diagram / Operational Description / Parts List / Turn up procedure Rationale for request for confidentiality: SOLiD, Inc., has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would give them competitive advantage in developing similar products. If you have questions or need further information, please contact the undersigned. Sincerely Yours,

External Photos

Page 1 of 6 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 2 of 6 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 3 of 6 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 4 of 6 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 5 of 6 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 6 of 6 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)

ID Label/Location Info

Page 1 of 1 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) IDENTIFICATION LABEL: PROPOSED FCC ID LABEL The FCC ID shall be permanently affixed to the rear side of the equipment FCC ID AREA

Internal Photos

FCC ID. : W6U70L21A Page 1 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : W6U70L21A Page 2 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : W6U70L21A Page 3 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : W6U70L21A Page 4 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : W6U70L21A Page 5 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : W6U70L21A Page 6 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : W6U70L21A Page 7 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : W6U70L21A Page 8 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : W6U70L21A Page 9 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : W6U70L21A Page 10 of 10 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)

Test Report

FCC ID. : W6U70L21A Page 1 of 116 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) ELECTROMAGNETIC EMISSION C OMPLIANCE REPORT FOR LICENSED TRANSMITTER Test Report No. : E12DR-046 AGR No. : A12DA-055 Applicant : SOLiD , Inc Address : 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 463-400 Manufacturer : SOLiD , Inc Address : 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 463-400 Type of Equipment : SINGLE CARRIER DAS FCC ID. : W6U70L21A Model Name : SC-MRU700LTEAWS-AC Serial number : N/A Total page of Report : 116 pages (including this page) Date of Incoming : December 06, 2012 Date of issue : December 26, 2012 SUMMARY The equipment complies with the regulation; FCC Part 27 Subpart C. This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Prepared by: Approved by: Ki-Hong, Nam / Senior Engineer Y. K. Kwon / Exe. Managing Director EMC/RF Center EMC/RF Center ONETECH Corp. ONETECH Corp. FCC ID. : W6U70L21A Page 2 of 116 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 6 2. TEST SUMMARY .............................................................................................................................................................. 7 2.1 TEST ITEMS AND RESULTS .............................................................................................................................................. 7 2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS ........................................................................................... 7 2.3 RELATED SUBMITTAL(S) / GRANT(S) ............................................................................................................................ 7 2.4 PURPOSE OF THE TEST ................................................................................................................................................... 7 2.5 TEST METHODOLOGY .................................................................................................................................................... 7 2.6 TEST FACILITY ............................................................................................................................................................... 7 3. GENERAL INFORMATION ............................................................................................................................................ 8 3.1 PRODUCT DESCRIPTION ................................................................................................................................................. 8 3.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 9 3.3 PERIPHERAL EQUIPMENT ............................................................................................................................................... 9 3.4 MODE OF OPERATION DURING THE TEST ..................................................................................................................... 10 4. EUT MODIFICATIONS ................................................................................................................................................. 10 5. RF POWER OUTPUT AT ANTENNA TERMINAL ................................................................................................... 11 5.1 OPERATING ENVIRONMENT ......................................................................................................................................... 11 5.2 TEST SET-UP ................................................................................................................................................................. 11 5.3 TEST EQUIPMENT USED ................................................................................................................................................ 11 5.4 TEST DATA .................................................................................................................................................................... 12 5.4.1 Test Result for Part 27 C (AWS-1) ....................................................................................................................... 12 5.4.2 Test Result for Part 27 C (700LTE) ..................................................................................................................... 13 6. OCCUPIED BANDWIDTH ............................................................................................................................................ 14 6.1 OPERATING ENVIRONMENT ......................................................................................................................................... 14 6.2 TEST SET-UP ................................................................................................................................................................. 14 6.3 TEST EQUIPMENT USED ...................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 4 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) RF Test Page 2 of 4 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Conducted Page 3 of 4 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Radiated (30 Hz ~ 1GHz) Page 4 of 4 Report No. : E12DR-046 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Radiated (1GHz ~ 6GHz)

Contact Information

Applicant

Yong Chul Kim(Team Manager)
[email protected]+82-31-627-6292Fax: +82-31-627-6009

Test Firm

ONETECH Corp.Ki Hong Nam
[email protected]82-31-799-9580Fax: 82-31-799-9599

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
327728 MHz - 757 MHz631.00 mWD7WAmp
Confidentiality
Long Term
Grant Notes
Booster. Power output listed is composite conducted. Device supports CDMA, EVDO, WCDMA, and LTE modulations. The antenna(s) used for this transmitter are to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power at each antenna must satisfy the MPE categorical exclusion requirements of � 2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of �1.1307(b)(3).

Other Applications from SOLiD, Inc.

W6UPSEVHFUHFR

DAS

May 21, 2026

Equipment Class

B9B - Part 90 Class B Industrial Booster (non-SMR)
W6UNMRFM25

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
W6UNMRFM34

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
W6UNHRFM34

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
W6UNMRFM40

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)