W6UEROU67835L2DAS System

SOLiD, Inc.
DAS System - FCC ID W6UEROU67835L2 - SOLiD, Inc.
Click to zoom

Application Details

Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)
Date of Grant
Feb 21, 2021
Application Purpose
Original Equipment
Date of Application
Feb 21, 2021
Equipment Note
DAS System
Frequency Range
758.00000000 - 768.00000000
Company
SOLiD, Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Confidential & Proprietary 1/17 eROU_67835L2_X User Manual Document Reference: Version: V1.0 Document Status: Release 1 Issue Date: Feb 05, 2021 Author: Dong-Gwon Ye o Department: R&D Division Te a m 2 Authorizing Manager: hyun-suk Chae Confidential & Proprietary 2/17 REVISION HISTORY Version Issue Date No. of Pages Initials Details of Revision Changes V 1.0 February 05, 2021 Original Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD Tehcnology, Inc. website at www.solid.co.kr or send email at [email protected] This manual is produced by Global Business Division Business Team Printed in Korea. Confidential & Proprietary 3/17 Contents Section1 Safety & Certification Notice ......................................................................... 4 Section2 System configuration and Functions .............................................................. 8 2.1 eROU(edge Remote Optic Unit)........................................................................... 8 2.1.1 Specifications of eROU ................................................................................. 9 2.1.2 Port on eROU ............................................................................................ 10 2.1.2.1 Functions .................................................................................................. 10 Section3 System Installation ..................................................................................... 13 3.1 eROU Installation ............................................................................................. 13 3.1.1 eROU Enclosure installation ......................................................................... 13 3.1.2 eROU(Internal Antenna) Mount Installation_ Case .1 ..................................... 14 3.1.3 eROU(Internal Antenna) Mount Installation_ Case .2 ..................................... 14 3.1.4 eROU(Internal Antenna) Mount Installation_ Case .3 ..................................... 15 3.1.5 eROU(External Antenna) Mount Installation ................................................. 15 3.1.6 Installation Cable Gland .............................................................................. 16 3.1.7 Power cabling ............................................................................................ 17 Confidential & Proprietary 4/17 Section1 Safety & Certification Notice Confidential & Proprietary 5/17 “Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.” - Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. - The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters. - eROU equipment is exclusive to the indoor. - Use this unit only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. - Any DAS system or Fiber BDA will generate radio (RF) signals and continuously emit RF energy. Avoid prolonged exposure to the antennas. SOLiD recommends maintaining a 70 cm minimum clearance from the antenna while the system is operating. - Do not operate this unit on or close to flammable materials, as the unit may reach high temperatures due to power dissipation. - Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives on the DAS equipment. Alcohol may be used to clean fiber optic cabling ends and connectors. - To prevent electrical shock, switch the main power supply off prior to working with the DAS System or Fiber BDA. Never install or use electrical equipment in a wet location or during a lightning storm. - Do not look into the ends of any optical fiber or directly into the optical transceiver of any digital unit. Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating transceiver or optical fiber connector to avoid the potential of radiation exposure. - Allow sufficient fiber length to permit routing without severe bends. - For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily accessible. - A readily accessible disconnect device shall be incorporated external to the equipment. - This power of this system shall be supplied through wiring installed in a normal building. If powered directly from the mains distribution system, it shall be used additional protection, such as Confidential & Proprietary 6/17 overvoltage protection device - Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote. Any equipment attached to this device not meeting this standard may cause degradation and unwanted signals in the bi-directional system. All components connected to this device must operate in the frequency range of this device. - Only 50 ohm rated antennas, cables and passive components operating from 150 - 3 GHz shall be used with this device. - The head end unit must always be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station. - Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shal…

Text truncated - open the document above for the full version.

Attestation Statements

SOLiD, Inc. 10,9th Floor, SOLiD Space 220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 463-400 Tel : +82-31-627-6290 Fax : +82-31-627-6209 ____________________________________________________________________________ Date: Feb 16, 2021 Federal Communications C ommission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 Subject: Letter for Warning Label Message FCC ID: W6UEROU67835L2 To Whom It May Concern: Warning label messages will be also shown in online and point-of-sale marketing materials and on outside packaging of device per KDB 935210 D02 Signal Boosters Certification v04r02 in Section V clause (g). B est Regards Company Name : SOLiD, Inc. Company Address : 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, South Korea Contact Person Name/Title (in print) : Yong chul Kim / Manager E-mail : [email protected]

Cover Letter(s)

Date : Nov. 9, 2017 Rev : 2.3 FCC Agent Authorization Letter HACS-F004 FCC Agent Authorization Letter HCT America LLC ([email protected]) 1726 Ringwood Avenue San Jose, CA 95131 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America LLC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America LLC Date : Nov. 9, 2017 Rev : 2.3 REVISION TABLE Rev Description of Change Date Approved 1.0 Original Release(Obsolete) 06/14/2012 QM 2.0 Updated template(Obsolete) 10/01/2012 QM 2.1 Updated address(Obsolete) 01/10/2014 QM 2.2 Updated address 11/18/2016 QM 2.3 Fixed Typo “Agent” 11/09/2017 QM HACS-F004 FCC Agent Authorization Letter HCT America LLC ([email protected]) 1726 Ringwood Avenue San Jose, CA 95131 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America LLC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America LLC SOLiD, Inc. DATE : Feb 16, 2021 To: Federal Communications Commis sion Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To whom it may concern: Subject : FCC Agent Authorization Letter for FCC ID : W6UEROU67835L2 We, the undersi gned, hereby authorize HCT CO., LTD. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by HCT CO., LTD. on our behalf shall have the same effect as acts of our own. We, the undersi gned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). We recognize that we are still responsible for the terms and conditions outlined in the HCT America Client Services Agreement. This authorization is valid until further written notice from the applicant. Sincerely, Signed by: Company Name : SOLiD, Inc. Company Address : 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, G yeonggi-do, S outh Korea Contact Person Name/Title (in print) : Yong chul Kim / Manager E-mail : [email protected] HACS-F004 FCC Agent Authorization Letter Rev : 2.3

Cover Letter(s)

Date : Nov. 09, 2017 Rev : 3.0 FCC Confidentiality Request Letter HACS-F003 FCC Confidentiality Request Letter HCT America LLC ([email protected]) 1726 Ringwood Avenue San Jose, CA 95131 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America LLC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America LLC Date : Nov. 09, 2017 Rev : 3.0 REVISION TABLE Rev Description of Change Date Approved 1.0 Original Release(Obsolete) 06/14/2012 QM 2.0 Updated template(Obsolete) 10/01/2012 QM 2.1 Updated address(Obsolete) 01/10/2014 QM 2.2 Updated address 11/18/2016 QM 3.0 Updated LTC and STC Confidentiality table 11/09/2017 QM HACS-F003 FCC Confidentiality Request Letter HCT America LLC ([email protected]) 1726 Ringwood Avenue San Jose, CA 95131 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America LLC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America LLC SOLiD, Inc. DATE : Feb 16, 2021 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD SUBJECT : Request for Confidentiality for FCC ID : W6UEROU67835L2 We hereby request confidential treatment of the information accompanying this application as outlined below: LONG-TERM AND SHORT-TERM CONFIDENTIAL LIST LONG-TERM CONFIDENTIAL Exhibit Description 1 Block Diagram 2 Operational Description 3 Parts List 4 Schematics 5 Tune-up Procedure SHORT-TERM CONFIDENTIAL (180 DAYS) 6 External Photos 7 Internal Photos 8 Test-Setup Photos 9 User’s Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Signed by: Company Name : SOLiD, Inc. Company Address : 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, G yeonggi-do, S outh Korea Contact Person Name/Title (in print) : Yong chul Kim / Manager E-mail : [email protected] HACS-F003 FCC Confidentiality Request Letter Rev : 3.0

External Photos

FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 1 of 7 EXTERNAL PHOTOGRAPHS FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 2 of 7 ■ EXTERNAL PHOTO(LEFT) FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 3 of 7 ■ EXTERNAL PHOTO(RIGHT) FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 4 of 7 ■ EXTERNAL PHOTO(REAR) FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 5 of 7 ■ EXTERNAL PHOTO(FRONT) FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 6 of 7 ■ EXTERNAL PHOTO(BOTTOM) FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 7 of 7 ■ EXTERNAL PHOTO(TOP)

ID Label/Location Info

1 ©2020 SOLiD. All Rights Reserved. This document is SOLiDproprietary. eROU_67835L2_X 200 mm 200 mm 83.5 mm

Internal Photos

FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 1 of 4 INTERNAL PHOTOGRAPHS FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 2 of 4 [TOP] FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 3 of 4 [Bottom] FCC ID: W6UEROU67835L2 / IC: 9354A-EROU67835L2 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 4 of 4 [Antenna Port]

RF Exposure Info

TEST REPORT FCC MPE Test for eROU_67835L2_X Certification APPLICANT SOLiD, Inc. REPORT NO. HCT-RF-2102-FC009 DATE OF ISSUE February 18, 2021 Tested by Kwang Il Yoon Technical Manager Jong Seok Lee HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383 KOREA Tel. +82 31 634 6300 F ax. +82 31 645 6401 F-TP22-03 (Rev. 03) Page 2 of 13 HCT Co., Ltd. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383 KOREA Tel. +82 31 634 6300 Fax. +82 31 645 6401 TEST REPORT FCC MPE Test for eROU_67835L2_X REPORT NO. HCT-RF-2102-FC009 DATE OF ISSUE February 18, 2021 Additional Model - A pplicantSOLiD, Inc. 10, 9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, South Korea Eut Type Model Name DAS System eROU_67835L2_X FCC ID W6UEROU67835L2 The result shown in this test report refer only to the sample(s) tested unless otherwise stated. This test results were applied only to the test methods required by the standard. Report No. HCT-RF-2102-FC009 F-TP22-03 (Rev. 03) Page 3 of 13 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 February 18, 2021 Initial Release The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. * The report shall not be reproduced except in full(only partly) without approval of the laboratory. Report No. HCT-RF-2102-FC009 F-TP22-03 (Rev. 03) Page 4 of 13 RF Exposure Statement 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34 1.34 - 30 30 - 300 300 - 1500 1500 - 100.000 614 824/f 27.5   1.63 2.19/f 0.073   *(100) *(180/ f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz * = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Report No. HCT-RF-2102-FC009 F-TP22-03 (Rev. 03) Page 5 of 13 - 600 MHz Service ˊ LTE 5 MHz (Downlink) Max Peak output Power at antenna input terminal 18.50 dBm Max Peak output Power at antenna input terminal 70.79 mW Prediction distance 70.00 cm Prediction frequency 619.50 MHz Antenna Gain(typical) 17.00 dBi Antenna Gain(numeric) 50.12 - Power density at prediction frequency( S) 0.0576 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.4130 mW/cm 2 - 600 MHz Service ˊ LTE 10 MHz (Downlink) Max Peak output Power at antenna input terminal 18.50 dBm Max Peak output Power at antenna input terminal 70.79 mW Prediction distance 70.00 cm Prediction frequency 622.00 MHz Antenna Gain(typical) 17.00 dBi Antenna Gain(numeric) 50.12 - Power density at prediction frequency( S) 0.0576 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.4147 mW/cm 2 Report No. HCT-RF-2102-FC009 F-TP22-03 (Rev. 03) Page 6 of 13 - 600 MHz Service ˊ LTE 20 MHz (Downlink) Max Peak output Power at antenna input terminal 18.50 dBm Max Peak output Power at antenna input terminal 70.79 mW Prediction distance 70.00 cm Prediction frequency 627.00 MHz Antenna Gain(typical) 17.00 dBi Antenna Gain(numeric) 50.12 - Power density at prediction frequency( S) 0.0576 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.4180 mW/cm 2 - Lower 700 MHz - LTE 5 MHz (Downlink) Max Peak output Power at antenna input terminal 18.50 dBm Max Peak output Power at antenna input terminal 70.79 mW Prediction distance 70.00 cm Prediction frequency 730.50 MHz Antenna Gain(typical) 17.00 dBi Antenna Gain(numeric) 50.12 - Power density at prediction frequency( S) 0.0576 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.4870 mW/cm 2 Report No. HCT-RF-2102-FC009 F-TP22-03 (Rev. 03) Page 7 of 13 - Lower 700 MHz - LTE 10 MHz (Downlink) Max Peak output Power at antenna input terminal 18.50 dBm Max Peak output Power at antenna input terminal 70.79 mW Prediction distance 70.00 cm Prediction frequency 733.00 MHz Antenna Gain(typical) 17.00 dBi Antenna Gain(numeric) 50.12 - Power density at prediction frequency( S) 0.0576 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.4887 mW/cm 2 - Upper 700 MHz - LTE 5 MHz (Downlink) Max Peak output Power at antenna input terminal 18.50 dBm Max Peak output Power at antenna input terminal 70.79 mW Prediction distance 70.00 cm Prediction frequency 748.50 MHz Antenna Gain(typical) 17.00 dBi Antenna Gain(numeric) 50.12 - Power density at prediction frequency( S) 0.0576 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.4990 mW/cm 2 Report No. HCT-RF-2102-FC009 F-TP22-03 (Rev. 03) Page 8 of 13 - Upper 700 MHz - LTE 10 MHz (Downlink) Max Peak output Power at antenna input terminal 18.50 dBm Max Peak output Power at antenna input terminal 70.79 mW Prediction distance 70.00 cm Prediction frequency 751.00 MHz Antenna Gain(typical) 17.00 dBi Antenna Gain(numeric) 50.12 - Power density at prediction frequency( S) 0.0576 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.5007 mW/cm 2 - FirstNet - LTE 5 MHz (Downlink) Max Peak output Power at antenna input terminal 18.50 dBm Max Peak output Power at antenna input terminal 70.79 mW Pre…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT FCC Test for eROU_67835L2_X Certification APPLICANT SOLiD, Inc. REPORT NO. HCT-RF-2102-FC008 DATE OF ISSUE February 18, 2021 Tested by Kwang Il Yoon Technical Manager Jong Seok Lee HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383 KOREA Tel. +82 31 634 6300 F ax. +82 31 645 6401 F-TP22-03 (Rev. 03) Page 2 of 171 HCT Co., Ltd. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383 KOREA Tel. +82 31 634 6300 Fax. +82 31 645 6401 TEST REPORT FCC Test for eROU_67835L2_X REPORT NO. HCT-RF-2102-FC008 DATE OF ISSUE February 18, 2021 Additional Model - A pplicantSOLiD, Inc. 10, 9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, South Korea Eut Type Model Name DAS System eROU_67835L2_X FCC IDW6UEROU67835L2 Output Power17 dBm Date of TestJanuary 21, 2021~ February 09, 2021 FCC Rule Parts:Part 2, Part 22, Part 27, Part 90 The result shown in this test report refer only to the sample(s) tested unless otherwise stated. This test results were applied only to the test methods required by the standard. Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 3 of 171 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 February 18, 2021 Initial Release The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. * The report shall not be reproduced except in full(only partly) without approval of the laboratory. Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 4 of 171 CONTENTS 1. GENERAL INFORMATION 5 1.1. APPLICANT INFORMATION 5 1.2. PRODUCT INFORMATION 5 1.3. TEST INFORMATION 5 2. FACILITIES AND ACCREDITATIONS 6 2.1. FACILITIES 6 2.2. EQUIPMENT 6 3. TEST SPECIFICATIONS 7 3.1. STANDARDS 7 3.2. ADDITIONAL DESCRIPTIONS ABOUT TEST 8 3.3. MEASUREMENTUNCERTAINTY 10 3.4. STANDARDS ENVIRONMENTAL TEST CONDITIONS 10 3.5. TEST DIAGRAMS 11 4. TEST EQUIPMENTS 12 5. TEST RESULT 13 5.1. AGC THRESHOLD 13 5.2. OUT-OF-BAND REJECTION 15 5.3. INPUT-VERSUS-OUTPUT SIGNAL COMPARISON 18 5.4. INPUT/OUTPUT POWER AND AMPLIFIER/BOOSTER GAIN 55 5.5. OUT-OF-BAND/OUT-OF-BLOCK EMISSIONS AND SPURIOUS EMISSIONS 73 5.6. RADIATED SPURIOUS EMISSIONS 166 6. Annex A_EUT AND TEST SETUP PHOTO 171 Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 5 of 171 1. GENERAL INFORMATION 1.1. APPLICANT INFORMATION Company Name SOLiD, Inc. Company Address 10, 9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, South Korea 1.2. PRODUCT INFORMATION EUT Type DAS System EUT Serial Number EX21020001 Power Supply DC 39~57 Vdc Frequency Range Band Name Downlink (MHz) 600 MHz Service 617 ~ 652 Lower 700 MHz 728 ~ 746 Upper 700 MHz 746 ~ 757 FirstNet 758 ~ 768 ESMR 862 ~ 869 Cellular 869 ~ 894 Tx Output Power 17 dBm Antenna Peak Gain 17 dBi 1.3. TEST INFORMATION FCC Rule Parts Part 2, Part 22, Part 27, Part 90 Measurement Standards KDB 935210 D05 v01r04, ANSI C63.26-2015 Test Location HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 6 of 171 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA. The site is constructed in conformance with the requirements of ANSI C63.4 (Version: 2014) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated April 02, 2018 (Registration Number: KR0032). 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of linearly polarized antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to perform radiated measurements. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, ᄲRadio Interference Measuring Apparatus and Measurement Methods.ᄶ Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 7 of 171 3. TEST SPECIFICATIONS 3.1. STANDARDS The following tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC Part 2, Part 22, Part 27, Part 90. Description Reference Results AGC threshold KDB 935210 D05 v01r04 3.2 Compliant Out-of-band rejection KDB 935210 D05 v01r04 3.3 Compliant Input-versus-output signal comparison §2.1049 Compliant Input/output power and amplifier/booster gain §2.1046, §22.913, §27.50(b), (c), §90.542, §90.635 Compliant Out-of-band/out-of-block emissions and spurious emissions §2.1051, §22.917, §27.53(c), (f), (g), §90.543 §90.691 Compliant Spurious emissions radiated §2.1053 Compliant Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 8 of 171 3.2. ADDITIONAL DESCRIPTIONS ABOUT TEST Except for the following cases, EUT was tested under normal operating conditions. : Out-of-band rejection test requires maximum gain condition without AGC. The test was generally based on the method of KDB 935210 D05 v01r04 and only followed ANSI C63.26-2015 if there was no test method in KDB standard. EUT was tested with following modulated signals provide by applicant. Band Name Tested signals 600 MHz Service LTE 5 MHz LTE 10 MHz LTE 20 MHz Lower 700 MHz LTE 5 MHz LTE 10 MHz Upper 700 MHz LTE 5 MHz LTE 10 MHz Fi…

Text truncated - open the document above for the full version.

Test Report

Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 109 of 171 +3 dB above Out-of-band (single test signals) / Upper 700 MHz / Downlink / LTE 5 MHz / Lower +3 dB above Out-of-band (single test signals) / Upper 700 MHz / Downlink / LTE 5 MHz / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 110 of 171 Out-of-band (single test signals) / Upper 700 MHz / Downlink / LTE 10 MHz / Lower Out-of-band (single test signals) / Upper 700 MHz / Downlink / LTE 10 MHz / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 111 of 171 +3 dB above Out-of-band (single test signals) / Upper 700 MHz / Downlink / LTE 10 MHz / Lower +3 dB above Out-of-band (single test signals) / Upper 700 MHz / Downlink / LTE 10 MHz / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 112 of 171 Out-of-band (single test signals) / FirstNet / Downlink / LTE 5 MHz / Lower Out-of-band (single test signals) / FirstNet / Downlink / LTE 5 MHz / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 113 of 171 +3 dB above Out-of-band (single test signals) / FirstNet / Downlink / LTE 5 MHz / Lower +3 dB above Out-of-band (single test signals) / FirstNet / Downlink / LTE 5 MHz / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 114 of 171 Out-of-band (single test signals) / FirstNet / Downlink / LTE 10 MHz / Lower Out-of-band (single test signals) / FirstNet / Downlink / LTE 10 MHz / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 115 of 171 +3 dB above Out-of-band (single test signals) / FirstNet / Downlink / LTE 10 MHz / Lower +3 dB above Out-of-band (single test signals) / FirstNet / Downlink / LTE 10 MHz / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 116 of 171 Out-of-band (single test signals) / ESMR / Downlink / CDMA / Lower Out-of-band (single test signals) / ESMR / Downlink / CDMA / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 117 of 171 +3 dB above Out-of-band (single test signals) / ESMR / Downlink / CDMA / Lower +3 dB above Out-of-band (single test signals) / ESMR / Downlink / CDMA / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 118 of 171 Out-of-band (single test signals) / ESMR / Downlink / WCDMA / Lower Out-of-band (single test signals) / ESMR / Downlink / WCDMA / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 119 of 171 +3 dB above Out-of-band (single test signals) / ESMR / Downlink / WCDMA / Lower +3 dB above Out-of-band (single test signals) / ESMR / Downlink / WCDMA / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 120 of 171 Out-of-band (single test signals) / ESMR / Downlink / LTE 5 MHz / Lower Out-of-band (single test signals) / ESMR / Downlink / LTE 5 MHz / Upper Report No. HCT-RF-2102-FC008 F-TP22-03 (Rev. 03) Page 121 of 171 +3 dB above Out-of-band (single test signals) / ESMR / Downlink / LTE 5 MHz / Lower +3 dB above Out-of-band (single test signals) / ESMR / Downlink / LTE …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yong Chul Kim(Team Manager)
[email protected]+82-31-627-6292Fax: +82-31-627-6009

Test Firm

HCT Co., Ltd.Lee Yoon-Jung
[email protected]82-31-645-6432Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower OutputEmission
29758 MHz - 768 MHz49.00 mWG7W
Confidentiality
Long Term
Grant Notes
In-Building DAS Industrial Booster. Power output listed is conducted per band. The device is capable of transmitting multiple signals in different bands at the same time with maximum combined conducted power of 0.300 Watts. This filing includes compliance information and test data for incumbent public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. ERP for operations under Part 90.219(e)(1) are limited to 5 Watts. The antenna(s) used with this transmitter must be fix-mounted on permanent structures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The single unit RF Exposure compliance for the device was based on maximum antenna gain 17 dBi with minimum separation distance 70 cm. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and licensing, and the use of higher gain antennas may require larger separation distances.

Other Applications from SOLiD, Inc.

W6UPSEVHFUHFR

DAS

May 21, 2026

Equipment Class

B9B - Part 90 Class B Industrial Booster (non-SMR)
W6UNMRFM25

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
W6UNMRFM34

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
W6UNHRFM34

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
W6UNMRFM40

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)