FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SOLiD, Inc./
  3. W6UHM70P80P

W6UHM70P80PRDU (Remote Drive Unit)

SOLiD, Inc.
RDU (Remote Drive Unit) - FCC ID W6UHM70P80P - SOLiD, Inc.
Click to zoom

Application Details

Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)
Date of Grant
Mar 26, 2015
Application Purpose
Original Equipment
Date of Application
Feb 13, 2015
Equipment Note
RDU (Remote Drive Unit)
Frequency Range
851.00000000 - 861.00000000
Company
SOLiD, Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Confidential & Proprietary 1/39 HERCULES (Alliance 5W Remote Unit) User Manual SOLiD, Inc. 10,9th Floor, SOLiD Space220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 393-400 Tel : +82-31-627-6290 Fax : +82-31-627-6209 Confidential & Proprietary 2/39 REVISION HISTORY Version Issue Date No. of Pages Initials Details of Revision Changes V 1.0 September. 07, 2014 Original Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD Tehcnology, Inc. website at www.solid.co.kr or send email at [email protected] This manual is produced by Global Business Division Business Team 1. Printed in Korea. Confidential & Proprietary 3/39 Contents Section1 Safety & Certification Notice ....................................................................... 5 Section2 Introduction ............................................................................................... 9 2.1 Purpose ......................................................................................................... 10 2.2 HERCULES ...................................................................................................... 11 Section3 Functional Description .............................................................................. 12 3.1 General ......................................................................................................... 13 3.2 Component of HERCULES Remote Unit ............................................................. 14 3.3 Dimension ..................................................................................................... 16 Section4 System Installation ................................................................................... 17 4.1 Remote Unit Installation ................................................................................. 19 4.1.1 Remote Unit Enclosure installation .................................................................. 19 4.1.2 How to expand ADD ON ROU at the Remote Unit .............................................. 23 4.1.3 Remote Unit Power Cabling ............................................................................. 25 4.1.4 Remote Unit Ground cabling ........................................................................... 26 4.1.5 Optical Cabling ............................................................................................... 28 4.1.6 Mounting of MRDU ........................................................................................ 30 Section5 System Specifications ................................................................................ 35 5.1 Physical Specifications .................................................................................... 36 5.2 RF performance .............................................................................................. 37 5.3 Certification ................................................................................................... 38 Confidential & Proprietary 4/39 Contents of Figure Figure 3.1 – Remote Unit Block Diagram ............................................................ 13 Figure 3.2 – Inside of Remote Unit .................................................................... 14 Figure 3.3 – Remote Unit Dimension ................................................................. 16 Figure 4.1 – Exterior of Remote Unit .................................................................. 19 Figure 4.2 – Dimension used to install REMOTE UNIT on the WALL ........................ 20 Figure 4.3 – Procedures of installation ............................................................... 21 Figure 4.5 – Connection diagram between Remote Unit and ADD ON ROU (DC type) .............................................................................................................. 24 Figure 4.6 – Location of Ground Terminal ........................................................... 26 Figure 4.7 – Information of Terminal .................................................................. 26 Figure 4.8 – How to install Ground Terminal ....................................................... 27 Figure 4.9 – Location of Optical Connector ......................................................... 28 Figure 4.10 – Information of Optical Connector .................................................. 28 Figure 4.11 – How to install Optical Cabling ........................................................ 29 Figure 4.12 – Location of MRDU ........................................................................ 30 Figure 4.13 – How to mount MRDU ................................................................... 31 Figure 4.14 – How to mount FAN Unit ................................................................ 32 Figure 4.15 – How to mount FAN Unit ................................................................ 33 Confidential & Proprietary 5/39 Section1 Safety & Certification Notice Confidential & Proprietary 6/39 “Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.” - Obey all general and regional safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. - The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters. - To prevent electrical shock, switch the main power supply off prior to working with the DAS System or Fiber BDA. Never install or use electrical equipment in a wet location or during…

Text truncated - open the document above for the full version.

Cover Letter(s)

SOLiD, Inc. 10,9th Floor, SOLiD Space 220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 463-400 Tel : +82-31-627-6290 Fax : +82-31-627-6209 ____________________________________________________________________________ Date: Jan. 14, 2015 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 Subject: Letter for Warning Label Message FCC ID: W6UHM70P80P To Whom It May Concern: Warning label messages will be also shown in online and point-of-sale marketing materials and on outside packaging of device per KDB 935210 D02 in Section V clause (g). Best Regards

Cover Letter(s)

SOLiD, Inc. 10,9th Floor, SOLiD Space 220 Pangyoyeok-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 463-400 Tel : +82-31-627-6290 Fax : +82-31-627-6209 ____________________________________________________________________________ Date: Jan. 14, 2015 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 RE: Request of Confidentiality for FCC ID: W6UHM70P80P To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), and Section 552 (b) (4) of the Freedom of Information Act, SOLiD, Inc. hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give SOLiD, Inc. temporary confidentiality of commercially sensitive information prior to product release. The requested Confidential and Temporary Confidential exhibits are listed as follows: CONFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description CONFIDENTIAL 1 Block Diagram 2 Operational Descriptions 3 Parts Lists and Tune-Up Procedure 4 Schematics SHORT-TERM CONFIDENTIAL 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 User’s Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. SOLiD, Inc.

External Photos

FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P H CT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/10 EXTERNAL PHOTOGRAPHS FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P H CT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/10 FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P H CT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/10 FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P H CT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/10 FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P H CT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/10 External Sub RU Chassis Photos FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/10 FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/10 FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 8/10 FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 9/10 FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 10/10

ID Label/Location Info

ID Label : MRDU-70P80P WARNING Label FCC ID : W6UHM70P80P Model : MRDU-70P80P Made in KOREA IC : 9354A-HM70P80P FCC Label FCC ID : W6UHM70P80P Model : MRDU-70P80P Made in KOREA IC : 9354A-HM70P80P ID Label WARNING Label FCC Label

Internal Photos

FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/15 INTERNAL PHOTOGRAPHS FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 8/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 9/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 10/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 11/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 12/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 13/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 14/15 FCC ID : W6UHM70P80P / IC:9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 15/15

RF Exposure Info

FCC ID: W6UHM70P80P / IC: 9354A-HM70P80P RF EXPOSURE STATEMENT 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34....................................... 1.34 - 30....................................... 30 - 300....................................... 300 - 1500.................................... 1500 - 100.000................................. 614 824/f 27.5 ............... ............... 1.63 2.19/f 0.073 ............... ............... *(100) *(180/ f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz * = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna FCC ID: W6UHM70P80P / IC: 9354A-HM70P80P 2-1 Limit (700 Band LTE 5MHz) Max Peak output Power at antenna input terminal 37.05 dBm Max Peak output Power at antenna input terminal 5069.907 mW Prediction distance 300.000 cm Prediction frequency 760.500 MHz Antenna Gain(typical) 17.000 dBi Antenna Gain(numeric) 50.1 - Power density at prediction frequency( S) 0.22467 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.507 mW/cm 2 2-2 Limit (700 Band_iDEN) Max Peak output Power at antenna input terminal 37.070 dBm Max Peak output Power at antenna input terminal 5093.309 mW Prediction distance 300.000 cm Prediction frequency 758.013 MHz Antenna Gain(typical) 17.000 dBi Antenna Gain(numeric) 50.1 - Power density at prediction frequency( S) 0.22571 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.505 mW/cm 2 FCC ID: W6UHM70P80P / IC: 9354A-HM70P80P 2-3 Limit (800 Band_iDEN) Max Peak output Power at antenna input terminal 37.040 dBm Max Peak output Power at antenna input terminal 5058.247 mW Prediction distance 300.000 cm Prediction frequency 851.013 MHz Antenna Gain(typical) 17.000 dBi Antenna Gain(numeric) 50.119 - Power density at prediction frequency( S) 0.22415 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.567 mW/cm 2 3. RESULTS The power density level at 300 cm is 0.22467mW/cm², which is below the uncontrolled exposure limit of 0.507 mW/cm² at 700 Band LTE 5MHz The power density level at 300 cm is 0.22571 mW/cm², which is below the uncontrolled exposure limit of 0.505 mW/cm² at 700 Band iDEN The power density level at 300 cm is 0.22415 mW/cm², which is below the uncontrolled exposure limit of 0.567 mW/cm² at 800 Band iDEN Note: “"RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances."

Test Report

Report No.: HCT-R-1501-F011-1 MODEL: MRDU-70P80P Page 2 of 125 F-01P-02-014 (Rev.00) HCT CO., LTD FCC ID: W6UHM70P80P / IC: 9354A-HM70P80P Report Revision TEST REPORT NO. DATE DESCRIPTION HCT-R-1501-F011 January 13, 2015 - First Approval Report HCT-R-1501-F011-1 February 04, 2015 - Revised FCC Rules - Added ‘Mask G’ test result Report No.: HCT-R-1501-F011-1 MODEL: MRDU-70P80P Page 3 of 125 F-01P-02-014 (Rev.00) HCT CO., LTD FCC ID: W6UHM70P80P / IC: 9354A-HM70P80P Table of Contents 1. CLIENT INFORMATION _______________________________________________________________ 4 2. FACILITIES AND ACCREDITATIONS ____________________________________________________ 5 2.1. FACILITIES ......................................................................................................................................... 5 2.2. EQUIPMENT ....................................................................................................................................... 5 3. TEST SUMMARY ____________________________________________________________________ 6 3.1. STANDARDS ...................................................................................................................................... 6 3.2. MODE OF OPERATION DURING THE TEST .................................................................................... 6 4. STANDARDS ENVIRONMENTAL TEST CONDITIONS ______________________________________ 7 5. TEST EQUIPMENT ___________________________________________________________________ 8 6. RF OUTPUT POWER _________________________________________________________________ 9 7. OCCUPIED BANDWIDTH ____________________________________________________________ 29 8. PASSBAND GAIN AND BANDWIDTH & OUT OF BAND REJECTION _________________________ 45 9. NOISE FIGURE _____________________________________________________________________ 48 10. EMISSION MASKS _________________________________________________________________ 50 11. SPURIOUS AND HARMONIC EMISSION AT ANTENNA TERMINAL _________________________ 54 12. RADIATED SPURIOUS EMISSIONS __________________________________________________ 117 13. FREQUENCY STABILITY OVER TEMPERATURE AND VOLTAGE VARIATIONS ______________ 122 Report No.: HCT-R-1501-F011-1 MODEL: MRDU-70P80P Page 4 of 125 F-01P-02-014 (Rev.00) HCT CO., LTD FCC ID: W6UHM70P80P / IC: 9354A-HM70P80P 1. CLIENT INFORMATION The EUT has been tested by request of Company SOLiD, Inc. 10, 9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, South Korea ■ FCC ID: W6UHM70P80P ■ IC: 9354A-HM70P80P ■ APPLICANT: SOLiD, Inc. ■ EUT Type: RDU (Remote Drive Unit) ■ Model: MRDU-70P80P ■ Frequency Ranges: 758 MHz ~ 775 MHz (768 MHz ~ 769 MHz Guard band) 851 MHz ~ 861 MHz ■Conducted Output Power: 5 W (37 dBm) ■ Antenna Gain(s) : Manufacturer does not provide an antenna. ■ FCC Rules Part(s): CFR Title 47, Part 90 ■ IC Rules Part(s): RSS-Gen (Issue4, November 2014), RSS-131( Issue 2, July 2003) ■ Measurement standard(s): ANSI/TIA-603-C-2004, KDB 971168 D01 v02r02, KDB 935210 D03 v02r01, RSS-131( Issue 2, July 2003) ■ Place of Tests: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, Korea. (IC Recognition No. : 5944A-3) Report No.: HCT-R-1501-F011-1 MODEL: MRDU-70P80P Page 5 of 125 F-01P-02-014 (Rev.00) HCT CO., LTD FCC ID: W6UHM70P80P / IC: 9354A-HM70P80P 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea. The site is constructed in conformance with the requirements of ANSI C63.4. (Version :2003) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated February 28, 2014 (Registration Number: 90661). 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of Linearly polarized antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre- selectors and quasi-peak detectors are used to perform radiated measurements. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring Apparatus and Measurement Methods.” Report No.: HCT-R-1501-F011-1 MODEL: MRDU-70P80P Page 6 of 125 F-01P-02-014 (Rev.00) HCT CO., LTD FCC ID: W6UHM70P80P / IC: 9354A-HM70P80P 3. TEST SUMMARY 3.1. STANDARDS The following tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC Part90, RSS-GEN, RSS-131. Description Reference (FCC) Reference (IC) Results Conducted RF Output Power §2.1046, §90.541, §90.542, §90.635 RSS-131, Section 4.3 RSS-131, Section 6.2 Compliant Occupied Bandwidth §2.1049 RSS-GEN, Section 4.6.1 Compliant Passband Gain and Bandwidth & Out of Band Rejection KDB 935210 D03 v02r01 RSS-131, Section 4.2 RSS-131, Section 6.1 Compliant Noise Figure §90.219 - Compliant Emission Masks §90.210 - Compliant Spurious Emissions at Antenna Terminals §2.1051, §90.543, §90.691 RSS-131, Section 4.4 RSS-131, Section 6.3 RSS-131, Section 6.4 Compliant Radiated Spurious Emissions §2.1053, §90.543, §90.691 - Compliant Frequency Stability §2.1055, §90.213, §90.539 RSS-131, Section 4.5 RSS-131, Section 6.5 Compliant 3.2. MODE OF OPERATION DURING THE TEST The EUT was operated in a manner representative of the typical usage of the equipment. During all testing, system components were manipulated within the confines of typical usage to maximize each emission. The device does not supply antenna(s) with the system, so the dummy loads were connected to the RF output ports for radiated spurious emission testing. Test Frequency & Modulation Frequency Modulation 758 MHz - 768 MHz LTE(5 MHz) 758 MHz - 775 MHz (768 MHz ~ 769 MHz Guard band) iDEN(25 kHz) 851 MHz - 861 MHz iDEN(25 kHz) Report No…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/5 TEST SETUP PHOTOGRAPHS FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/5 ■ AC Power Test Setup Photo FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/5 ■ DC Power Test Setup Photo FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/5 ■ Conducted Emission Test Setup Photo-1 FCC ID : W6UHM70P80P / IC: 9354A-HM70P80P HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/5 ■ Conducted Emission Test Setup Photo-2

Contact Information

Applicant

Yong Chul Kim(Team Manager)
[email protected]+82-31-627-6292Fax: +82-31-627-6009

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
39851 MHz - 861 MHz5.061 WW7WAmp
Confidentiality
Long Term
Grant Notes
Output power is conducted. Device supports LTE and iDEN modulations. This filing contains compliance information and test data for incumbent/duly-authorized public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. The single unit RF Exposure compliance for the device was based on maximum antenna gain 17 dBi and minimum separation distance 300 cm. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. RF exposure of simultaneous transmission including multiple units in single enclosure is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).

Other Applications from SOLiD, Inc.

W6UPSEVHFUHFR

DAS

May 21, 2026

Equipment Class

B9B - Part 90 Class B Industrial Booster (non-SMR)
W6UNMRFM25

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
W6UNMRFM34

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
W6UNHRFM34

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
W6UNMRFM40

nGENESIS

Mar 17, 2026

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)