Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Date: 1/21/2026 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(5) Attestation FCC ID: W6UNLRFM23 1. SOLiD, Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2. SOLiD, Inc. (“the applicant”) certifies that, the device does not have cybersecurity and / or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, identified on the Covered List installed on the device, nor will it be installed by the applicant anytime after certification. 3. SOLiD, Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Sincerely yours, Name: Yong chul Kim Job Title: Manage Company Name: SOLiD, Inc.
1 Date: 2/11/2026 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(7) FCC US Agent Letter of Attestation FCC ID: W6UNLRFM23 Grantee FRN: 0018550988 To whom it may concern: FCC US Agent Agent Company Name: Solid Gear, Inc. FCC FRN: 0034264838 Agent Contact Name: Ryan Oliveira Agent US Address: 800 Klein Rd, Suite 200, Plano TX 75074 Agent Email Address: [email protected] This letter is to confirm that we have accepted the responsibility to act as US Agent on behalf of SOLiD, Inc. (“the applicant”) for the above referenced FCC ID. We are aware of the requirements and responsibilities of the applicant’s agent for service of process as outlined in the FCC section 2.911(d)(7) and Report and Order FCC 22-84 paragraph 63. Sincerely, Ryan Oliveira Senior Product Line Manager Solid Gear, Inc.
Date: 2/11/2026 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 RE: CFR 47 §2.911 (d)(7) Agent Designation Attestation FCC ID: W6UNLRFM23 Grantee FRN: 0018550988 SOLiD, Inc. (“the applicant”) as required by section 2.911(d)(7), designates the following agent, located in the United States, for purposes of acting as the applicant’s agent for service of process. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility under CFR 47 §2.929(c) to inform the FCC whenever the agent information changes. U.S. Agent Information: FCC FRN: 0034264838 Contact Person: Ryan Oliveira Company Name: Solid Gear, Inc. Company Address: 800 Klein Rd, Suite 200, Plano TX 75074 Email: [email protected] Sincerely yours, Name: Yong chul Kim Job Title: Manage Company Name: SOLiD, Inc.
Date: 2/10/2026 Federal Communications Commissions Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: W6UNLRFM23 ATTESTATION With respect to section IV (d) of 935210 D02 Signal Booster Certification v04r03, we confirm the signal booster warning label messages will be shown in online and point-of-sale marketing materials and on outside packaging of device. ⚫ For frequency bands under “Industrial (Part 20) Signal Booster”: With respect to section IV (d) of 935210 D02 Signal Booster Certification v04r03, we confirm the signal booster warning label messages will be shown in online and point-of-sale marketing materials and on outside packaging of device. Sincerely yours, Name: Yong chul Kim Job Title: Manage Company Name: SOLiD, Inc.
Date: 1/21/2026 Federal Communications Commission Equipment Authorization branch 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. In authorizing UL Verification Services Inc. as our representative, we still recognize that we are responsible to: a) fulfill the requirements for the scope of certification requested, including implementing any appropriate changes requested by UL Verification Services Telecommunications Certification Body (TCB) and / or the FCC; b) supply any and all information needed for the evaluation of the products for which certification is sought; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) not use our product certification in such a manner as to bring the TCB or FCC into disrepute and to not make any statement regarding product certification which the TCB or FCC may consider misleading or unauthorized; e) discontinue use of all advertising matter that contains any reference thereto and complies with any and all actions required by the FCC upon suspension or cancellation of certification; f) use certification only to indicate that products are certified in conformity with specified standards; g) endeavor to ensure that no certificate or report or any part thereof is used in a misleading manner, and any copies of the grants/certificates shall be reproduced in their entirety; h) comply with the requirements of the TCB and FCC, including the use of marks and label information prescribed for the scope of certification, when making reference to product certification in communication media such as documents, brochure or advertisements; i) comply with the requirements for certification, supply any information needed for evaluation of products to be certified and, where applicable, make provision for the participation of observers; j) ensure that products marketed under the scope of the requested certification continue to comply with the certification requirements; k) provide a sample of a production unit for testing within 30 days of the request should this product be selected as part of either the TCB’s or the FCC’s market surveillance requirements; l) keep a record of all complaints relating to product’s compliance with requirements of relevant standard; make records available to UL or FCC when requested; take appropriate action with respect to such complaints and any deficiencies found in the product that affect compliance with requirements for certification; document the actions taken with respect to complaints and/or deficiencies; m) inform the TCB immediately of any changes that may affect its ability to comply with the certification requirements. This authorization is valid until further written notice from the applicant. Sincerely Yours, Name: Yong chul Kim Job Title: Manage Company Name: SOLiD, Inc.
CONFIDENTIALITY REQUEST Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 1/23/2026 To Whom It May Concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, SOLiD, Inc. requests confidentiality for the following products: FCC ID: W6UNLRFM23 The following exhibits contain trade secrets and proprietary information that could be of benefit to our competitors regarding the design of our product. This material is not customarily available to the general public and we request that it be withheld from public inspection. We request that the following information submitted be held permanent confidential treatment. Permanent Confidential Request • Schematic • Block Diagram • Operational description • Part List We request that the following information submitted be held short-term confidential treatment for 180 days. Short- term Confidential Request • Internal Photos • External Photos • Test-Setup Photos • User’s Manual If you have any questions, please feel free to contact me at the address shown below. Best regards, Name: Yong chul Kim Job Title: Manage Company Name: SOLiD, Inc.
SOLiD 본문서의저작권은SOLiD에있으며, 허가없는무단전재와재배포등사외반출을금지합니다. Phoenix 개발팀 nGENESISFCC Label_Phoenix 본문서의저작권은SOLiD에있으며, 허가없는무단전재와재배포등사외반출을금지합니다. 2 History Rev No.DataPage변경내용비고 V0.126.01.13초안 V0.226.02.04Rainproof추가및오타수정 본문서의저작권은SOLiD에있으며, 허가없는무단전재와재배포등사외반출을금지합니다. 3 nLRFM명판통합건검토(1/2) 베트남 생산 한국 생산 NAME PLATE Part 90 and Part 20 Signal Boosters THIS IS A 90.219 CLASS B DEVICE WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Part 90 Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal- boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of$100,000 for each continuing violation. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_7L FCC ID : W6UNLRFM7L Made in KOREA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_8C FCC ID : W6UNLRFM8C Made in KOREA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_17 FCC ID : W6UNLRFM17 Made in KOREA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_19 FCC ID : W6UNLRFM19 Made in KOREA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_23 FCC ID : W6UNLRFM23 Made in KOREA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_25 FCC ID : W6UNLRFM25 Made in KOREA Part 90 and Part 20 Signal Boosters THIS IS A 90.219 CLASS B DEVICE WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Part 90 Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal- boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of$100,000 for each continuing violation. Part 90 and Part 20 Signal Boosters THIS IS A 90.219 CLASS B DEVICE WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Part 90 Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal- boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of$100,000 for each continuing violation. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_7L FCC ID : W6UNLRFM7L Made in Vietnam This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_8C FCC ID : W6UNLRFM8C Made in Vietnam This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_17 FCC ID : W6UNLRFM17 Made in Vietnam This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_19 FCC ID : W6UNLRFM19 Made in Vietnam This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product : SOLiDGENESIS ® Model : nLRFM_23 FCC ID : W6UNLRFM23 Made in Vietnam This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept …
Text truncated - open the document above for the full version.
- Band = - Transmitting frequency = MHz ~ MHz mm dBi =Maximum power density Numeric power gain of the antenna Maximum power with turn-up toler ance Distance from transmitting antenna 2 Copyright ⓒ 2026, UL Korea, Ltd. = 0. 111882 ㎽/㎝ 2 Conclusion: The exposure condition of this device is compliant with FCC rul es. The limit for maximum permi ssible exposure = 1.000000 ㎽/㎝ S = P G / ( 4 R 2 π) , ㎽/㎝ 2 S = G = P = R = 158.5 mW dBm - Max. Antenna Gain = 5.5 - Max. power with turn-up tolerance = 22.00 Internal Antenna Type - Min. test separation distance = 200 2350 2360 FCC ID : W6UNLRFM23 Maximum Permissible Ex posure(MPE) evaluation January 23, 2026 WCS - Band = - Transmitting frequency = MHz ~ MHz mm dBi =Maximum power density Numeric power gain of the antenna Maximum power with turn-up toler ance Distance from transmitting antenna 2 Copyright ⓒ 2026, UL Korea, Ltd. = 0. 312172 ㎽/㎝ 2 Conclusion: The exposure condition of this device is compliant with FCC rul es. The limit for maximum permi ssible exposure = 1.000000 ㎽/㎝ S = P G / ( 4 R 2 π) , ㎽/㎝ 2 S = G = P = R = 158.5 mW dBm - Max. Antenna Gain = 17 - Max. power with turn-up tolerance = 22.00 External Antenna Type - Min. test separation distance = 450 2350 2360 FCC ID : W6UNLRFM23 Maximum Permissible Ex posure(MPE) evaluation January 23, 2026 WCS
CERTIFICATION TEST REPORT Report Number. : U-4792013068-FR5V3 Applicant : SOLiD, Inc. 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea Model : nLRFM_23 FCC ID : W6UNLRFM23 EUT Description : nGENESIS Test Standard(s) : FCC CFR47 PART 2 FCC CFR47 PART 27 Date Of Issue: 2026-03-04 Prepared by: UL KOREA LTD. 26th floor, 152, Teheran-ro, Gangnam-gu Seoul, 06236, Korea Uiwang Test Site: UL Korea, Ltd. Uiwang Laboratory 42, Obongsandan 1-ro, Uiwang-si, Gyeonggi-do, Republic of Korea, TEL: (031) 389-9603 FAX: (031) 462-8355 REPORT NO: U-4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 2 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd Revision History Rev. Issue Date Revisions Revised By V1 2026-01-05 Initial issue Jungi Shin V2 2026-02-24 Updated to address TCB`s question Jungi Shin V3 2026-03-04 Updated to address TCB`s question Jungi Shin REPORT NO: U-4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 3 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 6 4.1. MEASURING INSTRUMENT CALIBRATION ................................................................ 6 4.2. SAMPLE CALCULATION .............................................................................................. 6 4.3. MEASUREMENT UNCERTAINTY ................................................................................ 6 4.4. DECISION RULE .......................................................................................................... 6 5. EQUIPMENT UNDER TEST ............................................................................................... 7 5.1. DESCRIPTION OF EUT ................................................................................................ 7 5.2. DESCRIPTION OF AVAILABLE ANTENNAS ............................................................... 7 5.3. WORST-CASE ORIENTATION ..................................................................................... 8 5.4. DESCRIPTION OF TEST SETUP ................................................................................. 9 6. TEST AND MEASUREMENT EQUIPMENT ......................................................................10 7. SUMMARY TABLE ...........................................................................................................12 8. CONDUCTED RESULTS ..................................................................................................13 8.1. AGC THRESHOLD ......................................................................................................13 8.2. OUT-OF-BAND REJECTION .......................................................................................15 8.2.1. OUT-OF-BAND REJECTION TEST PLOT ...........................................................16 8.3. INPUT-VERSUS-OUTPUT SIGNAL COMPARISON ....................................................17 8.3.1. INPUT-VERSUS-OUTPUT SIGNAL COMPARISON TEST PLOT .......................19 8.4. INPUT/OUTPUT POWER AND AMPLIFIER/BOOSTER GAIN ....................................21 8.4.1. OUTPUT POWER AND PARR TEST PLOT ........................................................24 8.5. OUT-OF-BAND/OUT-OF-BLOCK EMISSIONS AND SPURIOUS EMISSIONS ............26 8.5.1. OUT-OF-BAND/OUT-OF-BLOCK EMISSIONS PLOT .........................................29 8.5.2. CONDUCTED SPURIOUS EMISSIONS PLOT ....................................................31 9. RADIATED RESULTS .......................................................................................................43 9.1. RADIATED SPURIOUS EMISSIONS ...........................................................................43 9.1.1. RADIATED SPURIOUS TEST RESULTS (ABOVE 1GHz) ..................................44 9.1.2. RADIATED SPURIOUS TEST RESULTS (BELOW 1GHz) ..................................47 9.1.3. RADIATED SPURIOUS TEST RESULTS (BELOW 30MHz) ................................49 REPORT NO: U-4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 4 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd 1. ATTESTATION OF TEST RESULTS COMPANY NAME: SOLiD, Inc. EUT DESCRIPTION: nGENESIS MODEL NUMBER: nLRFM_23 SERIAL NUMBER: Identical prototype DATE TESTED: 2025-10-03 - 2025-12-30 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 2 FCC PART 27 Complies Complies UL KOREA LTD. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL KOREA LTD. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report…
Text truncated - open the document above for the full version.
REPORT NO: U- 4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 37 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd WCS / Broadband / Low channel REPORT NO: U- 4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 38 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd WCS / Broadband / Low channel_additional band § 27.53 (a)(ii) § 27.53 (a)(i) § 27.53 (a)(iii) § 27.53 (a)(iii) § 27.53 (a)(iii) § 27.53 (a)(iii) § 27.53 (a)(iii) REPORT NO: U- 4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 39 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd WCS / Broadband / Mid channel REPORT NO: U- 4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 40 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd WCS / Broadband / Mid channel_additional band § 27.53 (a)(ii) § 27.53 (a)(i) § 27.53 (a)(iii) § 27.53 (a)(iii) § 27.53 (a)(iii) § 27.53 (a)(iii) § 27.53 (a)(iii) REPORT NO: U- 4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 41 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd WCS / Broadband / High channel REPORT NO: U- 4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 42 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd WCS / Broadband / High channel_additional band § 27.53 (a)(ii) § 27.53 (a)(i) § 27.53 (a)(iii) § 27.53 (a)(iii) § 27.53 (a)(iii) § 27.53 (a)(iii) § 27.53 (a)(iii) REPORT NO: U-4792013068-FR5V3 DATE: 2026-03-04 FCC ID: W6UNLRFM23 Page 43 of 50 UL Korea, Ltd. Uiwang Laboratory FORM ID: FCC_15C(05) 42, Obongsandan 1-ro, Uiwang-si , Gyeonggi-do, Republic of Korea TEL: (031) 389-9603 FAX: (031) 462-8355 UL KOREA LTD. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd 9. RADIATED RESULTS 9.1. RADIATED SPURIOUS EMISSIONS RULE PART(S) FCC: §2.1053 LIMIT § 2.1053 Measurements required: Field strength of spurious radiation. (a) Measurements shall be made to detect spurious emissions that may be radiated directly from the cabinet, control circuits, power leads, or intermediate circuit elements under normal conditions of installation and operation. Curves or equivalent data shall be supplied showing the magnitude of each harmonic and other spurious emission. For this test, single sideband, independent sideband, and controlled carrier transmitters shall be modulated under the conditions specified in paragraph (c) of §2.1049, as appropriate. For equipment operating on frequencies below 890 MHz, an open field test is normally required, with the measuring instrument antenna located in the far-field at all test frequencies. In the event it is either impractical or impossible to make open field measurements (e.g. a broadcast transmitter installed in a building) measurements will be accepted of the equipment as installed. Such measurements must be accompanied by a description of the site where the measurements were made showing the location of any possible source of reflections which might distort the field strength measurements. Information submitted shall include the relative radiated power of each spurious emission with reference to the rated power output of the transmitter, assuming all emissions are radiated from halfwave dipole antennas. (b) The measurements specified in paragraph (a) of this section shall be made for the following equipment: (1) Those in which the spurious emissions are required to be 60 dB or more below the mean power of the transmitter. (2) All equipment operating on frequencies higher than 25 MHz. (3) All equipment where the antenna is an integral part of, and attached directly to the transmitter. (4) Other types of equipment as required, when deemed necessary by the Commission. TEST PROCEDURE Because KDB 935210 D05 procedure does not provide this requirement, measurements were in accordance with the test methods section 5.5 of ANSI C63.26-2015 a) Place the EUT in the center of the turntable. The EUT shall be configured to transmit into the standard non-radiating load (for measuring radiated spurious emissions), connected with cables of minimal length unless specified otherwise. If the EUT uses an adjustable antenna, the antenna shall be positioned to the length that produces the worst case emission at the fundamental operating frequency. b) Each emission under consideration shall be evaluated: 1) Raise and lower the measurement antenna in accordance 5.5.2, as necessary to enable detection of the maximum emission amplitude relative to measurement antenna height. 2) Rotate the EUT through 360° to determine the maximum emission level relative to the axial position. 3) …
Text truncated - open the document above for the full version.
800 Klein Rd, Suite 200 · Plano, 75044 · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 27 | 2.35 GHz - 2.36 GHz | 140.00 mW | G7W | Amp |
| 2 | 27 | 2.35 GHz - 2.36 GHz | 140.00 mW | D7W | Amp |
Equipment Class
B9B - Part 90 Class B Industrial Booster (non-SMR)nGENESIS
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)nGENESIS
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)nGENESIS
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)nGENESIS
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)