Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 06, 2023
Application Purpose
Original Equipment
Date of Application
Aug 06, 2023
Equipment Note
ADVANCED DIAGNOSTICS & INFORMATION SYSTEM
Frequency Range
2402.00000000 - 2480.00000000
Company
Autel Intelligent Technology Corp., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC STATEMENT : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOT E: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. RF Exposure Information (SAR) This device meets the government’s requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy. The exposure standard for wireless devices employs a unit of measurement known as Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/Kg. For body-worn operation, this device has been tested and meets the FCC RF exposure guidelines for use with an accessory that contains no metal. RF exposure compliance with any body-worn accessory that contains metal was not tested and certified, and use of s uch body-worn accessory should be avoided. FCC Note Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Shielded cables must be used with this unit to ensure compliance with the Class B FCC limits. - English: " This device complies with Industry Canada licence-exempt RSS standard( s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device." - French:" Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil nedoit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement."

Attestation Statements

- Autel Intelligent Technology Corp., Ltd. - The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/13/2023 U.S. Agent Designation [Autel Intelligent Technology Corp., Ltd.] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: [WQ8-DV2221]): Name and company of U.S. agent: Autel US, Inc Physical U. S. address of agent: 36 Harbor Park Drive, Port Washington, NY 11050-4651, United States FRN of U.S. agent: 0032544660 Email address of U.S. agent: [email protected] [Autel US, Inc] acknowledges their obligation to accept service of process on behalf of [Autel Intelligent Technology Corp., Ltd.]. [Autel Intelligent Technology Corp., Ltd.] with the FRN [0018132787] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanentl y terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm th e above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature [Name] Frank Li [Title] President [Company] Autel Intelligent Technology Corp., Ltd. Signature [Name of U.S. agent] Paul A Marshall [Title of U.S. agent] Manager [Company of U.S. agent] Autel US, Inc 48_[mo del] US_Agent_2.911(d)(7) - U, V04

Attestation Statements

Autel Intelligent Technology Corp., Ltd. The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/13/2023 To whom it may concern: We, [Autel Intelligent Technology Corp., Ltd.], hereby certify that the equipment for which authorization is sought (FCC ID: [WQ8-DV2221]) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the fi lin g of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist ) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). Sincerely, Signature [Name] Frank Li [Title] President [Company] Autel Intelligent Technology Corp., Ltd. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V02

External Photos

Model Name: MaxiSys MS908S3 ---------------- End ----------------

ID Label/Location Info

Label Location On EUT Label Product Name: ADVANCED DIAGNOSTICS & INFORMATION SYSTEM Model Number: MaxiSys MS908S3 Trademark: AUTEL FCC ID: WQ8-DV2221 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Model Name: MaxiSys MS908S3 BT&WIFI Antenna GPS Antenna ---------------- End ----------------

RF Exposure Info

TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 1 of 44 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China SARTestReport For ApplicantName:AutelIntelligentTechnologyCorp.,Ltd. Address: Floor2,CaihongKejiBuilding,36Hi-techNorthSixRoad, SongpingshanCommunity,Xili,Nanshan,ShenzhenCity,China EUTName:ADVANCEDDIAGNOSTICS&INFORMATIONSYSTEM BrandName:AUTEL ModelNumber:MaxiSysMS908S3 IssuedBy CompanyName:BTFTestingLab(Shenzhen)Co.,Ltd. Address: F101,201and301,Building1,Block2,TantouIndustrialPark, TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, China ReportNumber:BTF230619R00901 TestStandards: 47CFRPart2.1093IEEE1528-2013IEEEC95.1-2019 KDB447498D01KDB865664D01KDB865664D02 KDB941225D06KDB248227D01KDB616217D04 KDB648474D04KDB690783D01 FCCID:WQ8-DV2221 TestConclusion:Pass TestDate:2023-07-05 DateofIssue:2023-07-06 PreparedBy: MonicaZhou/ProjectEngineer Date:2023-07-06 ApprovedBy: Ryan.CJ/EMCManager Date:2023-07-06 Note:Allthetestresultsinthisreportonlyrelatedtothetestingsamples.Whichcanbeduplicatedcompletelyforthelegalusewithapprovalof applicant;itshallnotbereproducedexceptinfullwithoutthewrittenapprovalofBTFTestingLab(Shenzhen)Co.,Ltd.,Alltheobjectionsshouldbe raisedwithinthirtydaysfromthedateofissue.Tovalidatethereport,youcancontactus. TestReportNumber:BTF230619R00901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 2 of 44 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China RevisionHistory VersionIssueDateRevisionsContent R_V02023-07-06Original Note:Oncetherevisionhasbeenmade,thenpreviousversionsreportsareinvalid. TestReportNumber:BTF230619R00901 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 3 of 44 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China TableofContents 1.Introduction .........................................................................................................................................................................................................................4 1.1IdentificationofTestingLaboratory......................................................................................................................................................................4 1.2IdentificationoftheResponsibleTestingLocation............................................................................................................................................4 1.3LaboratoryCondition..............................................................................................................................................................................................4 1.4Announcement........................................................................................................................................................................................................4 2.ProductInformation ...........................................................................................................................................................................................................5 2.1ApplicationInformation...........................................................................................................................................................................................5 2.2ManufacturerInformation .......................................................................................................................................................................................5 2.3FactoryInformation.................................................................................................................................................................................................5 2.4GeneralDescriptionofEquipmentunderTest(EUT).......................................................................................................................................5 2.5EquipmentunderTestAncillaryEquipment .......................................................................................................................................................5 2.6TechnicalInformation .............................................................................................................................................................................................5 3.SummaryofTestResults .................................................................................................................................................................................................6 3.1TestStandards........................................................................................................................................................................................................6 3.2DeviceCategoryandSARLimit ...........................................................................................................................................................................7 3.3TestResultSummary .............................................................................................................................................................................................7 3.4TestUncertainty ......................................................................................................................................................................................................8 4.MeasurementSystem.....................................................................................................................................................................................................10 4.1SpecificAbsorptionRate(SAR)Definition..................................................…

Text truncated - open the document above for the full version.

Test Report

Project No.: ZKT-230619L4592E2 Page 1 of 75 FCC TEST REPORT FCC ID: WQ8-DV2221 Report Number. ................................ : ZKT-230619L4592E2 Date of Test ......................................... Jun. 15, 2023 – Jun. 28, 2023 Date of issue ..................................... : Jul. 13, 2023 Total number of pages ....................... 75 Test Result ...................................... : PASS Testing Laboratory. ........................ : Shenzhen ZKT Technology Co., Ltd. Address ........................................... : 1/F , No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Applicant's name ......................... : Autel Intelligent Technology Corp., Ltd. Address ........................................... : Floor 2, Caihong Keji Building, 36 Hi-tech North Six Road, Songpingshan Community, Xili Sub-district, Nanshan District, Shenzhen City, China Manufacturer's name ................... : Autel Intelligent Technology Corp., Ltd. Address ........................................... : Floor 2, Caihong Keji Building, 36 Hi-tech North Six Road, Songpingshan Community, Xili Sub-district, Nanshan District, Shenzhen City, China Test specification: Standard ........................................... : FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2013 Test procedure ................................. : / Non-standard test method .............. : N/A Test Report Form No. .................... : TRF-EL-112_V0 Test Report Form(s) Originator .... : ZKT Testing Master TRF ................................... : Dated: 2021-04-22 This device described above has been tested by ZKT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ZKT, this document may be altered or revised by ZKT, personal only, and shall be noted in the revision of the document. Product name ................................. : ADVANCED DIAGNOSTICS & INFORMATION SYSTEM Trademark ....................................... : AUTEL Model/Type reference ....................... : MaxiSys MS908S3 Ratings .............................................. : Input: 12V 3A Battery: 3.85V 11600mAh, 44.66Wh Project No.: ZKT-230619L4592E2 Page 2 of 75 Te sting procedure and testing location: Testing Laboratory ..................................... : Shenzhen ZKT Technology Co., Ltd. Address ...................................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Tom Zou Te s ted by (name + signature) .................... : Jackson Fang Reviewer (name + signature) ..................... : Lake Xie Approved (name + signature) .................... : Project No.: ZKT-230619L4592E2 Page 3 of 75 Table of Contents Page 1. VERSION .................................................................................................................. 5 2. TEST SUMMARY ...................................................................................................... 6 2.1 TEST FACILITY ...................................................................................................... 7 2.2 MEASUREMENT UNCERTAINTY .......................................................................... 7 3. GENERAL INFORMATION ...................................................................................... 8 3.1 GENERAL DESCRIPTION OF EUT ........................................................................ 8 3.2 Test Setup Configuration ......................................................................................... 9 3.3 Support Equipment ................................................................................................ 10 3.4 Test Mode ............................................................................................................. 10 3.5 EQUIPMENTS LIST FOR ALL TEST ITEMS ........................................................ 11 4. EMC EMISSION TEST ............................................................................................ 13 4.1 Conducted emissions ............................................................................................ 13 4.1.1 POWER LINE CONDUCTED EMISSION Limits ................................................ 13 4.1.2 TEST PROCEDURE .......................................................................................... 13 4.1.3 DEVIATION FROM TEST STANDARD .............................................................. 13 4.1.4 TEST SETUP ..................................................................................................... 13 4.1.5 EUT OPERATING CONDITIONS ....................................................................... 14 4.2 Radiated emissions ............................................................................................... 17 4.2.1 Radiated Emission Limits ................................................................................... 17 4.2.2 TEST PROCEDURE .......................................................................................... 17 4.2.3 DEVIATION FROM TEST STANDARD .............................................................. 18 4.2.4 TEST SETUP ..................................................................................................... 18 4.2.5 EUT OPERATING CONDITIONS ....................................................................... 19 4.2.6 TEST RESULTS ................................................................................................. 19 5. RADIATED BAND EMISSION MEASUREMENT ................................................... 25 5.1 Test Requirement: ................................................................................................. 25 5.2 TEST PROCEDURE .....................…

Text truncated - open the document above for the full version.

Test Report

东莞市一佳电子通讯科技有限公司 Dongguan YiJia Electronics Communication Technology Co.,Ltd. 规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2023/06/21 编号 File No 23062101 版本 Revision 1.0 客户 CUSTOMER: 道通 客户料号 CUSTOMER NO: 501012406MS908S3 品名 2 4/5 8G Antenna 品名 PART NAME: 2.4/5.8G Antenna 供方料号 SUPPLIER NO: YJI01.005.084.301A 送样日期 Date: 送样数量Q“TY: 客户确认CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 供方确认SUPPLIER SIGNATURE APPROVALCHECKDESIGN add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 APPROVALCHECKDESIGN ChenGuoqiangXieLiChenXingyi YJ-RD-F04-A 承认书项目表 NO . 内容 (Contents) 页数 (Number of Page) 页码 (Page Code) 1 承认书封面(Spec Cover) 11 承认书封面(p) 2 承认书项目表(Spec Item ) 12 3 工程成品图(Drawing) 13 4 天线规格(Antenna Specification) 14 5 S参数测试(S Parameter ) 15 6 无源测试(Passive Test ) 36 ~ 8 7 方向图(Radiation Pattern ) 29 ~ 10 8 天线装配图(Antenna Profile) 311 ~ 13 9 材质证明(Mt ilC tifi t) 2814 419 材质证明(Material Certificate ) 2814 ~ 41 10 RoHS报告(RoHS Test Report ) **** 11N/AN/AN/A add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 12--- 13--- 天线规格 Antenna Specification Electrical Properties Frequency 2.4-2.5GHz 5.15-5.85GHz Impedance50 Ohm Nominal V.S.W.R2.0 Max Gain 2.8 [email protected] Gain 2.7 [email protected] RadiationOmni-directional PolarizationLinear Physical Properties Connector 4代IPEX Cable TypeO.D.0.81mm Cable Length70mm Cable ColorBlack add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Operating Temp.-40 ~ +85 ̊C Storage Temp / Humidity 25±5 ̊C / <70% AgilentAgilent E5071B SS Parameter Test // WIFI Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Y Z Y XX Y X Z add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 X P assive Tes t For WiFi/BT2.4G Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 2400 61.0 -2.22.7 2410 61.3 -2.12.8 2420 60.8 -2.22.8 2430 57.8 -2.42.5 2440 55 6-2624 2440 55.6 2.62.4 2450 59.1 -2.32.5 2460 59.5 -2.32.4 2470 61.4 -2.12.4 2480 60.2 -2.22.3 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 2490 60.4 -2.22.3 2500 61.2 -2.12.4 Passive Test For WiFi5.8G Freq (MHz) Effi (%) Effi (dB) Gain (dBi)(MHz)(%)(dB)(dBi) 5150 51.9 -2.91.5 5200 60.3 -2.22.0 5250 65.2 -1.92.6 6596 5300 66.9 -1.72.7 5350 64.9 -1.92.7 5400 64.8 -1.92.5 5450 64.2 -1.92.0 5500 65.5 -1.81.6 5550 64.3 -1.91.7 5600 66.3 -1.81.8 5650 62.3 -2.12.6 5700 65.3 -1.92.7 5750 65 4-1827 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 5750 65.4 -1.8 2.7 5800 65.5 -1.82.1 5850 61.4 -2.12.1 Radiation P attern For WIFI/BT Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Radiation Pattern For WIFI Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 DeviceDevice add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 WIFI/ BT Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 GPS天线 WIFI/BT天线 add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 , 安 全 資 料 表 版權2021-01-10 PSM-800FSDM-A/SMH-800 1 ,一、 化學品與廠商資料 化學品名稱:液態熱固軟板油墨 PSM-800FSDM-A/SMH-800 其他名稱: 建議用途及限制使用:柔性电路板(PI/Cu) ,手機天線板 製造者、輸入者或供應者名稱、地址及電話:製造者:優立實業股份有限公司 住址:桃園市觀音區經建四路22號 電話:886-3-4836651 緊急聯絡電話/傳真電話:電話:886-3-4836651、傳真:886-3-4837487 二、危害辨識資料 化學品危害分類: 健康及環境危害:急毒性物質(吞食)第 4 級、腐蝕/刺激皮膚物質第2級、嚴重損傷/刺激眼睛物質第2A級、皮膚 過敏物質第1級、致癌物質第2級、水環境之危害物質(急毒性)第2級。 標示內容: 象 徵 符 號: 警 示 語:警告 危害警告訊息: 吞食有害 造成皮膚刺激 造成嚴重眼睛刺激 可能造成皮膚過敏 懷疑致癌 對水生生物有毒 危害防範措施: 置容器於通風良好的地方 遠離高温 使用時勿吃、喝 衣服一經污染,立即脫掉 戴眼罩/護面罩 若與眼睛接觸,立刻以大量的水洗滌後洽詢醫療 戴上合適的手套 勿吸入氣體/煙氣/蒸氣/霧氣 使用前取得說明 置放於上鎖處 在瞭解所有安全防範措施之前切勿處置 避免釋放至環境中 其他危害:- 三、成份辨識資料 混合物: 中英文名稱:液態熱固軟板油墨PSM-800FSDM-A/SMH-800 化學性質: 危害成分之中英文名稱 化學文摘社登記號碼(CAS No.) 濃度或濃度範圍(成分百分比) 環氧丙烯酸酯寡聚物Epoxy acrylate oligmer 28064-14-4 50 % 二氧化矽Fused silica 7631-86-9 13 % 芳香族溶劑Aromatic solvent 64742-94-5 4 % , 安 全 資 料 表 版權2021-01-10 PSM-800FSDM-A/SMH-800 2 二丙二醇甲基醚Methyl dipropylene glycol 34590-94-8 4% 碳黑Carbon black 1333-86-4 3.5 % 硫酸鋇BaSO4 13462-86-7 24 % 光敏劑及其它Photoinitiator and the others 5495-84-1 1.5 % 四、急救措施 不同暴露途徑之急救方法: 吸 入:1.施救前先做好自身的防護措施。 2.移走污染源或將患者移至新鮮空氣處。 3.若有病人呼吸停止,立即由受過訓的人施以人工呼吸,若心跳停止,施行心肺復甦術,當患者吸入和吞下 毒性物質時,別直接使用口對口人工呼吸,應使用單向給氣式之口袋型面罩和其他醫療器材來執行人工呼 吸。 4.保持患者安靜及維持正常體溫。6.儘速就醫治療。 皮膚接觸:儘快以緩和流動的水沖洗受污染區域至少20 分鐘,沖水前,脫掉污染的衣物、鞋子、皮飾品。 眼睛接觸:立即將眼皮撐開用緩和流動的水沖洗受污眼睛至少20 分鐘,並立即就醫。 食 入:1.若患者即將喪失意識,或已喪失意識或痙攣,不可餵食任何東西。 2.不可催吐,並給予240-300ml 的水。 3.如果自發性嘔吐,讓其漱口,並反覆給水。 最重要症狀及危害效應:- 對急救人員之防護:- 對醫師之提示:- 五、滅火措施 適用滅火劑:化學乾粉、酒精泡沫、二氧化碳、噴水,大火:噴水、水霧、泡沫水霧。 滅火時可能遭遇之特殊危害: 1.其蒸氣及熱分解物易燃及有毒。 2.其蒸氣較空氣重,能傳播至遠處之火源處,發生回火。 3.蒸氣與大氣結合可能會發生爆炸。 4.當此物質在室內、室外或下水道有蒸氣爆炸危險。 特殊滅火程序: 1.在安全距離的地方滅火,保持在上風位置。 2.可用水冷卻容器,分散蒸氣沖洗外洩並稀釋外洩物,保護搶救人員。 3.用水噴灑露在火焰中的容器四週,使容器冷卻,直到火勢被撲滅為止。離開容器的本端以維安全。 4.撲滅或移開所有引燃源。 消防人員之特殊防護裝備:消防人員必須配戴空氣呼吸器、消防衣及防護手套。 六、洩漏處理方法 個人應注意事項: 1.限制人員進入,直至外溢區完全清理乾淨為止。 2.由受過訓之人員負責清理之工作。 3.穿戴適當的個人防護裝備。 環境注意事項: 1.移去引火源。 2.保持洩漏區通風。 3.處在上風處,避免進入低處。 4.在不危及人員安全情況下,搬移或隔離易燃和可燃物。 5.隔離污染源至少100 至200 公尺。 清理方法: 1.不可碰觸外洩物。 , 安 全 資 料 表 版權2021-01-10 PSM-800FSDM-A/SMH-800 3 2.避免外洩物進入下水道或密閉的空間內。 3.在安全許可的情形下,設法阻止或減少溢漏。 4.用不會和外洩物反應的泥土、沙或相似穩定且不可燃的物質圍堵外洩物。 5.少量溢漏時,用不會和外洩物反應之吸收劑吸收。已污染的吸收劑和外洩物具有同樣的 6.危害性,須置於加蓋並標示的適當容器裡。用水沖洗溢漏區域。 7.大量溢漏時:連絡消防、緊急處理單位及供應商以尋求協助。 七、安全處置與儲存方法 處置: 1.貯存於陰涼乾燥涼好通風的地方,並避免陽光直射、熱及引火源。 2.遠離不容物如強氧化物、強酸、水。 3.使用接地、與無火花之電器儀器、通風系統。 4.小量時貯存於冰箱,並使用防爆炸冰箱。 5.設外洩警報系統。 6.須貯存區與工作區隔離,並限制人員出入貯存區,並貼示警告標語。 7.避免碰撞,並就近設滅火系統。 8.不可單獨工作,另一人需隨時待命救援。 9.在工作區使用許可裝運燃燒性液體的容器,並且所有桶槽、轉裝容器都要接地,且須接觸到裸金屬。 10.使用最小可能的量,並在指定區內,使用適合的通風系統。 11.標示容器,當不使用時要緊蓋。 儲存: 1.貯存於陰涼乾燥涼好通風的地方,並避免陽光直射、熱及引火源。 2.小量時貯存於冰箱,並使用防爆炸冰箱。 3.須貯存區與工作區隔離,並限制人員出入貯存區,並貼示警告標語。 4.標示容器,當不使用時要緊蓋。 八、暴露預防措施 工程控制: 1.單獨使用步產生火花、接地的通風系統。 2.排氣口直接通到室外、並採取保護的重要措施。 3.大量使用此物質時,可能需要局部排氣裝置和製程密閉。 4.供給充分新鮮空氣以補充排氣系統抽出的空氣。 控制參數:- 八小時日時量平均容許濃度/短時間時量平均容許濃度/最高容許濃度:- 生物指標:- 個人防護設備: ̇呼吸防護:1.含有機蒸汽過濾毒罐之化學品過濾毒呼吸防護具或自攜式呼吸防護具。 2.定流量式供氣式呼吸防護具,動力型含有機蒸氣濾罐空氣淨化呼吸防護具,含有機蒸氣濾毒罐的面罩, 全面型自攜式呼吸防護具,全面型供氣式呼吸防護具,全面型含有機蒸汽濾毒罐之化學品濾毒呼吸防護具。 3.正壓全面型攜式呼吸防護具或含輔助型正壓自攜式呼吸防護具之正壓全面型供氣式呼吸防護具。 4.有機蒸氣濾毒罐的面罩,逃生型自攜式呼吸防護具。 ̇手部防護:丁基橡膠最佳,氯聚乙烯,聚乙烯酸,氟化彈性體、丁基橡膠∕氯丁橡膠,鐵氟龍,氯丁橡膠∕天然橡膠銀罩, 氟化彈性體∕氯丁基橡膠亦佳的防滲手套。 ̇眼睛防護:1.防濺化學安全眼鏡。 2.全面罩。 3.勿戴隱形眼鏡。 ̇皮膚及身體防護:1.工作鞋及連身工作服。 2.工作區要有淋浴/沖洗設備。 衛生措施: 1.工作後儘速脫掉污染之衣物,洗淨後才可再穿戴。 , 安 全 資 料 表 版權2021-01-10 PSM-800FSDM-A/SMH-800 4 2.工作場所嚴禁抽煙或飲食。 3.處理此物後,須徹底洗手。 4.維…

Text truncated - open the document above for the full version.

Test Setup Photos

APPENDIX I -- TEST SETUP PHOTOGRAPH Photo of Radiation Emission Test ---------------- End ----------------

Contact Information

Applicant

Frank Li(President)
[email protected](86)755-86147779Fax: (86)755-86147758

Test Firm

Shenzhen ZKT Technology Co., Ltd.Lake Xie
[email protected]0086-13620010775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz10.30 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. SAR compliance for body-worn operation is based on a separation distance of 0 mm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn transmission is 0.093W/kg (1g).

Other Applications from Autel Intelligent Technology Corp., Ltd.

WQ8-DV2121

AUTOMOTIVE DIAGNOSIS & ANALYSIS SYSTEM

Sep 05, 2025

Equipment Class

DTS - Digital Transmission System
LITHIUM BATTERY BALANCER - FCC ID WQ8-BCE100 - Autel Intelligent Technology Corp., Ltd.
WQ8-BCE100

LITHIUM BATTERY BALANCER

Jun 26, 2024

Equipment Class

DTS - Digital Transmission System
Battery Leakage Tester - FCC ID WQ8-ALT100L - Autel Intelligent Technology Corp., Ltd.
WQ8-ALT100L

Battery Leakage Tester

Apr 01, 2024

Equipment Class

DTS - Digital Transmission System