Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
3 Trademarks Autel ® ,MaxiSys ® ,MaxiDAS ® , MaxiScan ® ,MaxiCheck ® ,MaxiRecorder ® ,and MaxiDAS ® are trademarks of Autel Intelligent Technology Corp., Ltd., registered in China, the United States and other countries. All other marks are trademarks or registered trademarks of their respective holders. Copyright Information No part of this manual may be reproduced, stored in a retrieval system or transmitted, in any form or by any means,electronic, mechanical, photocopying, recording, or otherwise without the prior written permission of Autel. Disclaimer of Warranties and Limitation of Liabilities All information, specifications and illustrations in this manual are based on the latest information available at the time of printing. Autel reserves the right to make changes at any time without notice. While information of this manual has been carefully checked for accuracy, no guarantee is given for the completeness and correctness of the contents, including but not limited to the product specifications, functions, and illustrations. Autel will not be liable for any direct, special, incidental, indirect damages or any economic consequential damages (including the loss of profits). IMPORTANT Before operating or maintaining this unit, please read this manual carefully, paying extra attention to the safety warnings and precautions. For Services and Support pro.autel.com www.autel.com 1‐855‐288‐3587/1‐855‐AUTELUS (North America) 0086‐755‐86147779 (China) [email protected] 4 For technical assistance in all other markets, please contact your local selling agent. Safety Information For your own safety and the safety of others, and to prevent damage to the device and vehicles upon which it is used, it is important that the safety instructions presented throughout this manual be read and understood by all persons operating or coming into contact with the device. There are various procedures, techniques, tools, and parts for servicing vehicles, as well as in the skill of the person doing the work. Because of the vast number of test applications and variations in the products that can be tested with this equipment, we cannot possibly anticipate or provide advice or safety messages to cover every circumstance. It is the automotive technician’s responsibility to be knowledgeable of the system being tested. It is crucial to use proper service methods and test procedures. It is essential to perform tests in an appropriate and acceptable manner that does not endanger your safety, the safety of others in the work area, the device being used, or the vehicle being tested. Before using the device, always refer to and follow the safety messages and applicable test procedures provided by the manufacturer of the vehicle or equipment being tested. Use the device only as described in this manual. Read, understand, and follow all safety messages and instructions in this manual. Safety Messages Safety messages are provided to help prevent personal injury and equipment damage. All safety messages are introduced by a signal word indicating the hazard level. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in deathorseriousinjurytotheoperatorortobystanders. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in deathorseriousinjurytotheoperatorortobystanders. 5 Safety Instructions The safety messages herein cover situations Autel is aware of. Autel cannot know, evaluate or advise you as to all of the possible hazards. You must be certain that any condition or service procedure encountered does not jeopardize your personal safety. 6 DANGER When an engine is operating, keep the service area WELL VENTILATED or attach a building exhaust removal system to the engine exhaust system. Engines produce carbon monoxide, an odorless, poisonous gas that causes slower reaction time and can lead to serious personal injury or loss of life. SAFETY WARNINGS Always perform automotive testing in a safe environment. Wear safety eye protection that meets ANSI standards. Keep clothing, hair, hands, tools, test equipment, etc. away from all moving or hot engine parts. Operate the vehicle in a well‐ventilated work area, for exhaust gases are poisonous. Put the transmission in PARK (for automatic transmission) or NEUTRAL (for manual transmission) and make sure the parking brake is engaged. Put blocks in front of the drive wheels and never leave the vehicle unattended while testing. Be extra cautious when working around the ignition coil, distributor cap, ignition wires and spark plugs. These components create hazardous voltages when the engine is running. Keep a fire extinguisher suitable for gasoline, chemical, and electrical fires nearby. Do not connect or disconnect any test equipment while the ignition is on or the engine is running. Keep the test equipment dry, clean, free from oil, water or grease. Use a mild detergent on a clean cloth to clean the outside of the equipment as necessary. Do not drive the vehicle and operate the test equipment at the same time. Any distraction may cause an accident. Refer to the service manual for the vehicle being serviced and adhere to all diagnostic procedures and precautions. Failure to do so may result in personal injury or damage to the test equipment. To avoid damaging the test equipment or generating false data, make sure the vehicle battery is fully charged and the connection to the vehicle DLC is clean and secure. Do not place the test equipment on the distributor of the vehicle. Strong electro‐magnetic interference can damage the equipment. 7 List 1.product description ................................................................................................................... 8 1.1Maxi SCR – Urea Pump Tester ............................................................ 8 2.SCR Diagnostic operation ....................................................................................................…
Text truncated - open the document above for the full version.
FCC ID: WQ8MAXISYSSCR
Label Location On EUT Label Product Name: MaxiSys SCR Model No.: MaxiSCR FCC ID: WQ8MAXISYSSCR This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation.
FCC ID: WQ8MAXISYSSCR ANT
version01 Autel Intelligent Tech. Corp., Ltd. Declaration concerning Antenna Specification It is hereby declared that the product Model No.: MaxiSCR FCC ID: WQ8MAXISYSSCR fulfills the requirement in FCC test relating to the antenna type. The device specified above confirms to the FCC recommendations for internal antenna type(s) described below: BDR&EDR+BLE Model No. of antenna: YJ-MaxiSCR-BT-V01 Type of antenna:FPCB Antenna Gain of the antenna: 4 dBi Frequency range:2402-2480MHz The mounting of the antenna is fixed to the radio module and no other antenna should be used. Company name: Autel Intelligent Tech. Corp., Ltd. Address: 7th-8th, 10th Floor, Bldg. B1, Zhiyuan, Xueyuan Rd. Xili, Nanshan, Shenzhen, China City:Shenzhen ZIP / Postal code: N/A Country:China Place:ShenzhenDate: 2020-07-31 Signature:
RF EXPOSURE EVALUATION According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in §1.1307(b) FCC ID: WQ8MAXISYSSCR EUT Specification EUTMaxiSys SCR Frequency band (Operating) WLAN: 2.412GHz ~ 2.462GHz WLAN: 5.18GHz ~ 5.32GHz / 5.50GHz ~ 5.70GHz WLAN: 5.745GHz ~ 5825GHz Others: 2.402GHz~2.480GHz (BDR&EDR+BLE) Device category Portable (<20cm separation) Mobile (>20cm separation) Others ___ Exposure classificationOccupational/Controlled exposure (S = 5mW/cm2) General Population/Uncontrolled exposure (S=1mW/cm2) Antenna diversitySingle antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Max. output power-0.721 dBm (0.0008W) for BDR&EDR -1.151 dBm (0.0008W) for BLE Antenna gain (Max)4dBi Evaluation applied MPE Evaluation SAR Evaluation Limits for Maximum Permissible Exposure(MPE) Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density(mW/cm 2 ) Average Time (A) Limits for Occupational/Control Exposures 300-1500----F/3006 1500-100000----56 (B) Limits for General Population/Uncontrol Exposures 300-1500----F/15006 1500-100000----130 Friis transmission formula: Pd=(Pout*G)\(4*pi*R2) Where Pd= Power density in mW/cm 2 Pout=output power to antenna in Mw G= gain of antenna in linear scale Pi=3.1416 R= distance between observation point and center of the radiator in cm Pd the limit of MPE, 1mW/cm2. If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. Measurement Result Operating Mode Channel Frequency (MHz) Measured Power (dBm) Tune up tolerance (dBm) Max. Tune up Power (dBm) Antenna Gain (dBi) Power density at 20cm (mW/ cm 2 ) Power density Limits (mW/cm 2 ) BLE 2402-1.154-1.154±1-0.15440.00051 2440-1.151-1.151±1-0.15140.00051 2480-1.375-1.375±1-0.37540.00051 BDR&E DR 2402-0.813-0.813±10.1874 0.0005 1 2441-0.744-0.744±10.25640.00051 2480-0.874-0.874±10.12640.00051 2402-0.823-0.823±10.17740.00051 2441-0.721-0.721±10.27940.00051 2480-0.862-0.862±10.13840.00051
Report No.: SZAWW181211003-01FCC ID: WQ8MAXISYSSCRPage 1 of 59 Code:AB-RF-05-a FCC TEST REPORT Client Name: Autel Intelligent Tech. Corp., Ltd. Address: 7th-8th, 10th Floor, Bldg. B1, Zhiyuan, Xueyuan Rd., Xili, Nanshan Shenzhen China Product Name: MaxiSys SCR Date: Jul. 30, 2020 Shenzhen Anbotek Compliance Laboratory Limited Report No.: SZAWW181211003-01FCC ID: WQ8MAXISYSSCRPage 2 of 59 Code:AB-RF-05-a Contents 1. General Information ............................................................................................................................................... 5 1.1. Client Information ....................................................................................................................................... 5 1.2. Description of Device (EUT) ..................................................................................................................... 5 1.3. Auxiliary Equipment Used During Test ................................................................................................... 6 1.4. Description of Test Modes ........................................................................................................................ 6 1.5. List of channels ........................................................................................................................................... 7 1.6. Description Of Test Setup ......................................................................................................................... 8 1.7. Test Equipment List .................................................................................................................................... 9 1.8. Measurement Uncertainty ....................................................................................................................... 10 1.9. Description of Test Facility ...................................................................................................................... 10 2. Summary of Test Results ................................................................................................................................... 11 3. Conducted Emission Test ................................................................................................................................... 12 3.1. Test Standard and Limit .......................................................................................................................... 12 3.2. Test Setup .................................................................................................................................................. 12 3.3. Test Procedure .......................................................................................................................................... 12 3.4. Test Data .................................................................................................................................................... 12 4. Radiation Spurious Emission and Band Edge ................................................................................................ 15 4.1. Test Standard and Limit .......................................................................................................................... 15 4.2. Test Setup .................................................................................................................................................. 15 4.3. Test Procedure .......................................................................................................................................... 16 4.4. Test Data .................................................................................................................................................... 17 5. Maximum Peak Output Power Test .................................................................................................................. 25 5.1. Test Standard and Limit .......................................................................................................................... 25 5.2. Test Setup .................................................................................................................................................. 25 5.3. Test Procedure .......................................................................................................................................... 25 5.4. Test Data .................................................................................................................................................... 25 6. 20DB Occupy Bandwidth Test ........................................................................................................................... 29 6.1. Test Standard ............................................................................................................................................ 29 6.2. Test Setup .................................................................................................................................................. 29 6.3. Test Procedure .......................................................................................................................................... 29 6.4. Test Data .................................................................................................................................................... 29 7. Carrier Frequency Separation Test ................................................................................................................... 33 7.1. Test Standard and Limit .......................................................................................................................... 33 7.2. Test Setup .................................................................................................................................................. 33 7.3. Test Procedure ....................................................................................................................................…
Text truncated - open the document above for the full version.
FCC ID: WQ8MAXISYSSCR Photo of Conducted Emission Measurement Photo of Radiation Emission Test
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 800.00 µW |
AUTOMOTIVE DIAGNOSIS & ANALYSIS SYSTEM
Equipment Class
DTS - Digital Transmission System
LITHIUM BATTERY BALANCER
Equipment Class
DTS - Digital Transmission System
Battery Leakage Tester
Equipment Class
DTS - Digital Transmission System
UNIVERSAL SMART KEY
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterADAS Calibration Frame
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter