FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHIMWOO ELECTRONICS CO., LTD./
  3. WT9SC33FO

WT9SC33FOIR/RF Remote Controller

SHIMWOO ELECTRONICS CO., LTD.
IR/RF Remote Controller - FCC ID WT9SC33FO - SHIMWOO ELECTRONICS CO., LTD.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Dec 18, 2013
Application Purpose
Original Equipment
Date of Application
Dec 18, 2013
Equipment Note
IR/RF Remote Controller
Frequency Range
433.92000000 - 433.92000000
Company
SHIMWOO ELECTRONICS CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

www.televisionlifts.com Phone 702 410 5024 Fax 702 778 3608 Up/Down and Swivel IR/RF Remote Control It is critical importance that the installer fully reads and understands these Instructions before installing or operating the lift. LIFT-TECH’s IR/RF remote controller for a motorized up/down and swivel lift is highly sophisticated and utilizes the latest computer chip technology to control the lift’s functions. The controller consists of a black electronic box, and IR/RF remote control. www.televisionlifts.com Phone 702 410 5024 Fax 702 778 3608 For RF press and hold “Down” and “1”for three seconds. For IR press and hold “Down” and “3” for three seconds. Operation of the hand-held transmitter is very straightforward. There are seven different buttons on the transmitter; an up arrow, a down arrow, a left arrow, a right arrow, and three preset buttons. The up arrow button commands the lift to raise. The left arrow button commands the left swivel function. The right arrow button commands the right swivel function. The down arrow button commands the lift to lower. If the lift is in a swiveled position when the down button is depressed, the swivel will return to center and then lower. The three preset buttons are labeled 1, 2, and 3. They can be programmed by the operator to any 3 preset positions of their choice. If the lift is lowered and a preset button is pressed, the lift will raise and rotate to the corresponding preset position. If any of the buttons are pressed with the lift raised, the swivel will rotate to the corresponding preset position. Once again, if the lift is in a swiveled position when the down button is depressed, the swivel will return center and then lower. The precision, reliability, and unique operating features of this controller clearly sets it apart form and ahead of any other in the marketplace. Installation and Operating Instructions If is of critical importance that the installer fully reads and understands these instructions before installing or operating the lift. When the lift is shipped from the factory, the swivel will be in center position. The swivel function will not operate with the transmitter when the lift is in the lowered position. The up/down functions will operate only when the swivel is in the center position. If vibration in shipping has caused the swivel to be out of center, do not rotate the swivel by hand. Use the manual override buttons on the control box to return the unit to center. LIFT-TECH utilizes a unique combination of computer chip technology and a solenoid to establish absolute center for the swivel. A potentiometer provides feedback to the controller so that the controller can determine the exact swivel position. This feature is important for a number of reasons: www.televisionlifts.com Phone 702 410 5024 Fax 702 778 3608 1. To establish absolute center, so that there is no “play” that might result in damage to the cabinetry when the lift raises and lowers. 2. To establish a maximum range of swivel operation. The Custom Television Lifts swivel will be shipped with a range of 180° in both directions; however, the limits may be readily reprogrammed at any time if less swivel travel is desired. This feature is beneficial for applications in which less travel is desired to avoid hitting a wall or other obstruction when swiveled too far. Once programmed, the controller will retain the swivel limits or “soft stops” until reprogrammed. 3. To set the preset positions: The precise feedback from the potentiometer ensures that the swivel always returns to the programmed preset position. 4. There are no external switches or magnets on the swivel. The use of the potentiometer will provide reliable operation without having to worry about magnet placement or switch adjustments. The controller will actually identify that the swivel is approaching the “soft spot” and will decelerate the swivel motor to ensure a smooth motion when stopping. IR Receiver Mounting and Connections The unit is designed to install in a ½” diameter hole and comes with a mounting nut and lens. The lens unscrews to allow the tube to be easily inserted through the back of the ½” hole. Once inserted, replace the lens and moderately tighten the mounting nut. Use caution not to over tighten the nut. An infrared system such as this requires a line of sight between the receiver and transmitter. Therefore, care should be taken to ensure that the receiver placement allows a line of sight to the infrared transmitter from normal operating position. The infrared receiver needs to be plugged into the connection on the box labeled IR EYE. www.televisionlifts.com Phone 702 410 5024 Fax 702 778 3608 Set Up 1. Plug the connector into the electronic control box. There are three connections to be made. The main lift cable is and eight pin Molex connector. It is plugged it to the female connector on the box labeled LIFT. The main lift cable provides power to the up/down motor and supplies power to the duplex receptacle on the lift platform. ( For up/down lift only the LIFT connection should be plugged in) The swivel cable has a twelve pin Molex connector. Plug it into the female connector on the box labeled SWIVEL. The swivel cable provides power to the swivel motor and the solenoid. In addition, it returns feedback to the control cox from the potentiometers. Mount and connect the receiver as described previous section. All connections are to be made prior to provident AC power. Plug the power cord into a 115V AC receptacle last. 2. After powering the unit, wait 15 seconds before using the hand-held transmitter. During this time, the controller is cycling through a learning mode. This learning mode will be utilized if the lift needs to be reprogrammed; however, it will retain the factory programmed settings in the absence of any input during this cycle. 3. After waiting 15 seconds, the swivel is now in operating mode. If the AC power source is interrupted, the controller will remember absolute…

Text truncated - open the document above for the full version.

Cover Letter(s)

SHIMWOO ELECTRONICS CO., LTD. Date: December 16, 2013 FCC Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Attention : Application Examiner / Reviewing Engineer Subject : Attestation for used operating frequency band Applicant : SHIMWOO ELECTRONICS CO., LTD. FCC ID : WT9SC33FO To whom it may concern, We, SHIMWOO ELECTRONICS CO., LTD. are guarantee for used frequency band as bellows, This model, IR/RF REMOTE will be used only following frequencies. * Used frequency band 433.92 MHz If you have questions or need further information, please contact the undersigned. Sincerely Yours, ____________________________ Jung-Hwo, Kim / Chief Engineer SHIMWOO ELECTRONICS CO., LTD. E-mail: [email protected]

Cover Letter(s)

SHIMWOO ELECTRONICS CO., LTD. EMCCert DR. RAŠEK GmbH Date: December 16, 2013 Stoernhofer Berg 15 91364 Unterleinleiter GERMANY To whom it may concern: I, the undersigned, hereby authorize Mr. Gea-Won, Lee / Managing Director of ONETECH Corp., and hereafter to as ONETECH, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Ant and all acts carried out by Mr. Gea-Won, Lee of ONETECH on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits. that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing EMCC as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures of advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, ____________________________ Jung-Hwo, Kim / Chief Engineer SHIMWOO ELECTRONICS CO., LTD. E-mail: [email protected]

Cover Letter(s)

SHIMWOO ELECTRONICS CO., LTD. FCC Laboratory Date: December 16, 2013 7435 Oakland Mills Road Columbia, MD 21046 Attention : Application Examiner / Reviewing Engineer Subject : Request for confidentiality per Section 0.459 of FCC Rules Applicant : SHIMWOO ELECTRONICS CO., LTD. FCC ID : WT9SC33FO To whom it may concern, Request is hereby submitted, SHIMWOO ELECTRONICS CO., LTD., to withhold from public review certain portions of the application for equipment certification for the referenced FCC identifier. In particular, the following sections of the application and report are requested to be kept confidential: Schematics / Block Diagram / Parts List / Operational description Rationale for request for confidentiality: SHIMWOO ELECTRONICS CO., LTD., has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would give them competitive advantage in developing similar products. If you have questions or need further information, please contact the undersigned. Sincerely Yours, ____________________________ Jung-Hwo, Kim / Chief Engineer SHIMWOO ELECTRONICS CO., LTD. E-mail: [email protected]

External Photos

FCC ID. : WT9SC33FO Page 1 of 6 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : WT9SC33FO Page 2 of 6 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : WT9SC33FO Page 3 of 6 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : WT9SC33FO Page 4 of 6 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : WT9SC33FO Page 5 of 6 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : WT9SC33FO Page 6 of 6 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)

ID Label/Location Info

FCC ID. : WT9SC33FO Page 1 of 1 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) IDENTIFICATION LABEL: PROPOSED FCC ID LABEL The FCC ID shall be permanently affixed in the rear side of the equipment FCC ID AREA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : WT9SC33FO

Internal Photos

FCC ID. : WT9SC33FO Page 1 of 3 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : WT9SC33FO Page 2 of 3 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) FCC ID. : WT9SC33FO Page 3 of 3 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)

Test Report

FCC ID. : WT9SC33FO Page 1 of 18 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-002 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) ELECTROMAGNETIC EMISSION COMPLIANCE REPORT FOR LOW-POWER, NON-LICENSED TRANSMITTER Test Report No. : E13DR-019 AGR No : A13NA-123 Applicant : SHIMWOO ELECTRONICS CO., LTD. Address : 5F, Yongjin Bldg, 402-1, Yangjae2-Dong, Seocho-gu, Seoul, Korea Manufacturer : SHIMWOO ELECTRONICS CO., LTD. Address : 5F, Yongjin Bldg, 402-1, Yangjae2-Dong, Seocho-gu, Seoul, Korea Type of Equipment : Single Frequency Remote Control FCC ID. : WT9SC33FO Model Name : IR/RF REMOTE Serial number : N/A Total page of Report : 18 pages (including this page) Date of Incoming : November 20, 2013 Date of issue : December 06, 2013 SUMMARY The equipment complies with the regulation; FCC Part 15 Subpart C Section 15.231. This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Prepared by: Approved by: Ki-Hong, Nam / Senior Engineer Gea-Won, Lee / Managing Director ONETECH Corp. ONETECH Corp. FCC ID. : WT9SC33FO Page 2 of 18 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-002 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................. 3 2. GENERAL INFORMATION ............................................................................................................ 4 2.1 PRODUCT DESCRIPTION ..................................................................................................................................................... 4 2.2 MODEL DIFFERENCES........................................................................................................................................................ 4 2.3 RELATED SUBMITTAL(S) / GRANT(S) ................................................................................................................................ 4 2.4 PURPOSE OF THE TEST ....................................................................................................................................................... 4 2.5 TEST METHODOLOGY ........................................................................................................................................................ 4 2.6 TEST FACILITY ................................................................................................................................................................... 4 3. SYSTEM TEST CONFIGURATION ............................................................................................... 5 3.1 JUSTIFICATION ................................................................................................................................................................... 5 3.2 PERIPHERAL EQUIPMENT .................................................................................................................................................. 5 3.3 MODE OF OPERATION DURING THE TEST .......................................................................................................................... 5 3.4. EUT MODIFICATIONS ................................................................................................................................................. 5 3.5 CONFIGURATION OF TEST SYSTEM ................................................................................................................................... 5 3.6 ANTENNA REQUIREMENT .................................................................................................................................................. 6 4. PRELIMINARY TEST ...................................................................................................................... 6 4.1 AC POWER LINE CONDUCTED EMISSIONS TESTS ............................................................................................................. 6 4.2 GENERAL RADIATED EMISSIONS TESTS ........................................................................................................................... 6 5. FINAL RESULT OF MEASURMENT ............................................................................................ 7 5.1 TEST DATA ......................................................................................................................................................................... 7 5.1.1 Field Strength of the Carrier Test .............................................................................................................................. 7 5.1.2 Maximum Modulation Percentage (MMP) ............................................................................................................... 8 5.1.3 Transmitter Transmission Duration ........................................................................................................................ 11 5.1.4 Spurious Emission Test ............................................................................................................................................ 12 5.1.5 Bandwidth of the operating frequency ..................................................................................................................... 15 6. FIELD STRENGTH CALCU…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID. : WT9SC33FO Page 1 of 2 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Radiated Emission Test FCC ID. : WT9SC33FO Page 2 of 2 Report No. : E13DR-019 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)

Contact Information

Applicant

Jung-Hwo Kim(Chief Engineer)
[email protected]+82-2-579-8512Fax: +82-2-579-8511

Test Firm

ONETECH Corp.Ki Hong Nam
[email protected]82-31-799-9580Fax: 82-31-799-9599

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term