Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Date:12-09-2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: X4GS06009 To Whom it may concern: Axon Enterprise, Inc ("the applicant") certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. Designated U.S. Agent Information: FCC FRN: 0017326364 Company Name: Axon Enterprise, Inc. Company US Address: 17800 N 85th St, Scottsdale, AZ 85255, USA Contact Person: Elisabet Dominguez Tel.: +1 480 676 2895 Email: [email protected] Sincerely, Axon Contact Person Name: Elisabet Dominguez US agent Contact Person Name: Elisabet Dominguez Title: Sr. Global Product Compliance Engineer I Title: Sr. Global Product Compliance Engineer I Company: Axon Enterprise, Inc. Company: Axon Enterprise, Inc.
Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: December 8, 2025 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: (X4GS06009) [Axon Enterprise, Inc] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Axon Enterprise, Inc] (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, Elisabet Dominguez Sr. Global Product Compliance Engineer I Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: December 8, 2025 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: (X4GS06009) [Axon Enterprise, Inc] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Elisabet Dominguez Sr. Global Product Compliance Engineer I
Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: November 12, 2025 SUBJECT: To Whom It May Concern: I, the undersigned, hereby states this equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules, and will apply the Supplier's Declaration of Conformity procedure to the class A computer peripheral portion of this composite device. I understand the following FCC requirements: 1. Devices subject to the SDoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm (Select the "accredited" option to search for FCC recognized accredited test firms.). 2. Pt 2.1077 contains the list of information that must be included in the Supplier's Declaration of Conformity, which must be supplied with each product sold. The SDoC compliance info shall be included in the User’s Manual or as a separate sheet. The info must contain the name, address, and phone number of the responsible party, which must be located within the United States. According to 2.909(b), the responsible party is either the Manufacturer or if the product is imported the Importer. Regards, Name: Elisabet Dominguez Title: Sr. Global Product Compliance Engineer I Axon Enterprise, Inc.
Declaration of Authorization BTL Inc. No. 29, Jintang Road, Tangzhen Industry Park Pudong New Area Shanghai, China We, Axon Enterprise, Inc., with address: 17800 N. 85th Street, Scottsdale, Arizona United States 85255 Declare that: Name Representative of agent: Ms. Riley Wei Agent Company name: BTL Inc. Address: No. 29, Jintang Road, Tangzhen Industry Park Pudong New Area City: Shanghai Country: China is authorized to apply for FCC and/or ISED Canada Certification of the following product, including the singing of the related documents such as IC application form(s)/ 731 forms: Product description: Outdoor LTE wireless camera Type designation: AX1054 Trademark: Axon IC: 8803A-S06009 FCC ID: X4GS06009 on our behalf. Date: November 18, 2025 Contact Person: Elisabet Dominguez Applicant: Axon Enterprise, Inc Phone: +1 480 676 2895 E-Mail: [email protected]
Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of Date: 12-09-2025 FCC ID: X4GS06009 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Exhibit Type: • Block Diagram • Schematics • Operational Description • Part List • BOM • Tune-Up procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until 180 days after the grant date: Exhibit Type • External Photos • Internal Photos • Test Setup Photos • User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Elisabet Dominguez Sr. Global Product Compliance Engineer I Axon Enterprise, Inc
AX1054 IP 66 Finished in the US with US and imported parts Requirement of PRIMAX Part: 1. Comply with PRIMAX QW-5Q002 "Green Product Chemical Substances Specification" 2. Follow customer's specification as required. 3.Follow Halogen- Free requirement : Br<900 ppm, Cl<900 ppm, Br+Cl< 1500 ppm if required. 30401435800A 2 PROJECT X mm Janice.chang Rong.zou2025/8/28 50#白色PET, 覆可打印霧膜 0.20.2 SNLABEL Pantone427C BlackC White Note: 1. Material: 50 micron white PET , with matt OPP film(can print) 50# 白色PET, 覆OPP可打印霧膜. 2. Size: 如上圖示, tolerance + 0.2mm - 3. 卷裝交料 3. Color: 4.2D barcode: Data matrix(ECC200) 1 7 . 0 0 m m 42.30 mm D20A Y#&#S from 2020/1/1,Y=33 alphanumeric combinations(0~Z),(remove“I”,“O”, “9”). fixed. S=34 alphanumeric combinations(0~Z),(remove“I”,“O”) #=numberfromg0~9 #=numberfromg0~9 &=numberfromg1~9(remove“0”) seeTableA 編碼進位說明: For example: The first SN is D01A, until the SN isD01A, the next SN isD01A...... 0000109990100 0 1 until D01A,the next SN is D01A........and so on. 01999010 Z0 When is999, must carry.When is999 and is Z, must carry. #&##&#SSY Code carry note: 當 變為999時, 進位.當 是999 且已進位到 Z時,必需進位. #&##&#SSY 舉例: 從2022/1/ 第1個 SN 是 D01A, 到SN變為D01A, 下一個 SN 為D01A...... 0000109990100 0 1 直到SN變為 D01A,則下一個 SN 為SN 為D01A ...........依此類推。 01999010 Z0 PN AXON Model # Top 4 digits 12-F0301AX01 AX1054 D20A D02AY#&#S 4 4 條碼寬度最大為4mm 符合本條碼位數及編碼 材質規格及檢驗方式,詳見廠商承認書內材質規格書。 For details on material specifications and inspection methods, please refer to the material specification sheet included in the supplier's approval document. vendor printingthermal print 35.00 S / N D20AY#&#S FCC ID: X4Gxxxxx IC: 8803A-xxxxxx REV X3 ROBOT MONO BOLD 9pt ROBOT MEDIUM 4pt ROBOT REGULAR 5pt 1 7 . 0 0 die cut scale 1:1 ⌀ ⌀ ⌀ ⌀ AX1054 IP 66 Finished in the US with US and imported parts AX1054 IP 66 Finished in the US with US and imported parts S / N D20AY#&#S FCC ID: X4GS06009 IC: 8803A-S06009 REV XX ROBOT MONO BOLD 9pt ROBOT MEDIUM 4pt ROBOT REGULAR 5pt AX1054 IP 66 Finished in the US with US and imported parts 1 8 . 0 0 R=1.75 R=2.25 R=4.9 50.79 AX1054 IP 66 Finished in the US with US and imported parts ->Rev.A forDVT/GAunitswith256GBeMMC ->Rev.X5 forDVTunitswith128GBeMMC 1/1 ID LABEL/LOCATION INFO Brand: Axon Model number: AX1054 Name: Elisabet Dominguez Job Title: Sr. Global Product Compliance Engineer I Company Name: Axon Enterprise, Inc.
Report No.: BTL-FCCP-6-2509H007 Project No.: 2509H007 Page 1 of 10 Report Version: R00 FCC RF Exposure Report FCC ID: X4GS06009 Report No. : BTL-FCCP-6-2509H007 Equipment : Outdoor LTE wireless camera Model Name : AX1054 Brand Name : Axon Applicant : Axon Enterprise, Inc Address : 17800 N. 85th Street, Scottsdale, Arizona 85255, USA FCC Rule Part(s) : 47 CFR § 2.1091 IEEE C95.1 Date of Receipt : 2025/9/11 Date of Test : 2025/10/2 ~ 2025/11/27 Issued Date : 2025/12/4 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Brett Shen, Engineer Approved by : Jerry Chuang, Vice Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-6-2509H007 Project No.: 2509H007 Page 2 of 10 Report Version: R00 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the Customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-6-2509H007 Project No.: 2509H007 Page 3 of 10 Report Version: R00 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-6-2509H007 R00 Original Report. 2025/12/4 Valid Report No.: BTL-FCCP-6-2509H007 Project No.: 2509H007 Page 4 of 10 Report Version: R00 1. LIMITS According to § 1.1310 Radiofrequency radiation exposure limits. (a) Specific absorption rate (SAR) shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in § 1.1307(b) of this part within the frequency range of 100 kHz to 6 GHz (inclusive). (b) The SAR limits for occupational/controlled exposure are 0.4 W/kg, as averaged over the whole body, and a peak spatial-average SAR of 8 W/kg, averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the parts of the human body treated as extremities, such as hands, wrists, feet, ankles, and pinnae, where the peak spatial-average SAR limit for occupational/controlled exposure is 20 W/kg, averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). Exposure may be averaged over a time period not to exceed 6 minutes to determine compliance with occupational/controlled SAR limits. (c) The SAR limits for general population/uncontrolled exposure are 0.08 W/kg, as averaged over the whole body, and a peak spatial-average SAR of 1.6 W/kg, averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the parts of the human body treated as extremities, such as hands, wrists, feet, ankles, and pinnae, where the peak spatial-average SAR limit is 4 W/kg, averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). Exposure may be averaged over a time period not to exceed 30 minutes to determine compliance with general population/uncontrolled SAR limits. (e) Limits for Maximum Permissible Exposure (MPE) to radiofrequency electromagnetic fields (Table 1). Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (i) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *(100) ≤6 3.0-30 1842/f 4.89/f *(900/f 2 ) <6 30-300 61.4 0.163 1.0 <6 300-1.500 f/300 <6 1.500-100.000 5 <6 (ii) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) <30 1.34-30 824/f 2.19/f *(180/f 2 ) <30 30-300 27.5 0.073 0.2 <30 300-1.500 f/1500 <30 1.500-100.000 1.0 <30 f = frequency in MHz. * = Plane-wave equivalent power density. Report No.: BTL-FCCP-6-2509H007 Project No.: 2509H007 Page 5 of 10 Report Version: R00 2. APPLIED EXEMPTION CRITERIA Refer to KDB 447498 D04, ticked item is applied: For RF Exposure Test Exemptions for Single Source: ☐ 1-mW Test Exemption Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or…
Text truncated - open the document above for the full version.
Outpost [DVT] Antenna test report Manufacturer: Axon Enterprise Inc, 17800 N 85th St, Scottsdale, AZ 85255 Measured at: 2025.08.25 – 2025.11.05 Measurements done by: Dmytro Vasylenko, Radio Frequency Engineer Ihor Kvachenok, Radio Frequency Engineer SQUAD Ukraine, 2025 Measurement Information: i. Devices was tested in a passive mode; ii. Measurement carried out with batteries installed; iii. For matching circuits Murata GJM03; GJM15 MLCC and LQP03TN; LQG15HS Chip Inductors are used; iv. Measurement procedure – TOSM calibration of VNA is carried out – the Murata switch connector are unsoldering from the main board – fixture compensation for prepared pigtails is carried out – pigtails are soldered in place of Murata switch connectors – during measurements, the pigtails of inactive antennas are loaded with 50 Ohm terminators. v. For LTE TX/RX Main LB+MB antenna measurements done in active mode, peak gain and efficiency calculated from TRP and EIRP respectively Peak Gain [dBi] = Peak EIRP - conducted power Efficiency [dB] = TRP - conducted power Measurement Equipment List: – Rohde&Schwarz ZNLE6 VNA (Cal Kit ZV-Z135) [Cal. Date 2023.11.07] – ETS-Lindgren AMS-8041 [OTA calibralion 2025.08.10] – Agilent E5071C [Cal. Date 2024.04.23] – Rohde&Schwarz CMW500 – EMQuest EMQ-100 Data Acquisition and Analysis Software Antennas definition: • LTE TX/RX Main LB+MB (B2, B4, B5, B12, B13, B14, B25, B26, B66) • LTE TX/RX Main HB (B7, B30) • LTE RX Diversity LB (B5, B12, B13, B14, B26) • LTE RX Diversity MB+HB (B2, B4, B7, B25, B30, B66) • GNSS, L1 band • Dual band 2.4GHz & 5GHz Wi-Fi/BT/BLE Passive maximum antenna peak gain summary table: Band Frequency, MHz LTE TX/RX Main LB+MB LTE TX/RX Main HB Wi-Fi/BT/BLE Gain, dBi Gain, dBi Gain, dBi Uplink (TX) B5 824 – 849 2.6 B12 699 – 716 0.1 B13 777 – 787 1.3 B14 788 – 798 1.5 B26 815 – 848 2.6 B2 1850 – 1910 3.3 B4 1710 – 1755 2.5 B25 1850 – 1915 3.3 B66 1710 – 1780 2.7 B7 2500 – 2570 2.8 B30 2305 – 2315 2.7 1-11 2401 – 4273 4.2 36-48 5150 – 5250 3.3 52-64 5250 – 5350 3.3 100-144 5470 – 5725 3 149-165 5725 – 5850 2.9 Passive antennas radiation efficiency results summary table: Band Frequency, MHz LTE TX/RX Main LB+MB LTE RX Diversity LB LTE TX/RX Main HB LTE RX Diversity MB+HB Wi-Fi/ BT/BLE GNSS Efficiency, dB Efficiency, dB Efficiency, dB Efficiency, dB Efficiency, dB Efficiency, dB Downlink (RX) B5 869 – 894 -2.8 -6.8 B12 729 – 746 -2.7 -2.7 B13 746 – 756 -2.8 -3.3 B14 758 – 768 -2.9 -3.9 B26 859 – 894 -2.6 -6.8 B2 1930 – 1990 -2.8 -4.3 B4 2110 – 2155 -3.2 -3.1 B25 1930 – 1995 -2.8 -3 B66 2110 – 2200 -3.2 -3.1 B7 2620 – 2690 -2.7 -4 B30 2350 – 2360 -3.3 -2.4 GNSS L1 1575 -5.6 Uplink (TX) B5 824 – 849 -2.9 B12 699 – 716 -2.6 B13 777 – 787 -3 B14 788 – 798 -2.9 B26 815 – 848 -2.5 B2 1850 – 1910 -2.6 B4 1710 – 1755 -3.1 B25 1850 – 1915 -2.9 B66 1710 – 1780 -3.1 B7 2500 – 2570 -2.9 B30 2305 – 2315 -3.6 1 – 11 2401 – 2473 -3.5 36 – 48 5150 – 5250 -3.7 52 – 64 5250 – 5350 -3.3 100 – 144 5470 – 5725 -3.4 149 – 165 5725 – 5850 -3.6 LTE TX/RX Main (HB) & LTE RX Diversity (MB+HB) Port 1 (S11) related to LTE TX/RX Main (HB) and Port 2 (S22) related to ANT3 LTE RX Diversity (MB+HB). Observed wide resonants with RL better than -6.9dB. Decided to go as is without optimization and fine tuning. LTE TX/RX Main (HB) performance shows batter than 40% of efficiency (-4dB). LTE RX Diversity (MB+HB) performance shows batter than 35% of efficiency (-4.5dB). LTE RX (Diversity LB) Return Losses shows vide resonant with no worse than -5.3dB. Test has been performed with Sub-1GHz antenna preloaded to 50 Ohm resistor. ANT2 performance shows efficiency better than -5dB over required frequency band. Dual band 2.4GHz & 5GHz Wi-Fi/BT/BLE & ANT4 GNSS L1 (1575.42MHz) Obtained fine-tuned resonants for both antennas. For Wi-Fi/BT/BLE antenna (Port 1, S11) on both bands RL better that -5.6dB and looks acceptable for further evaluation point of view. GNSS became better with wide resonant better than -10dB. GNSS performance shows more that 25% of efficiency (better than -6dB). Wi-Fi/BT/BLE 2.4GHz band performance shows more than 40% of efficiency (better than - 4dB). Wi-Fi/BT/BLE 5GHz band performance shows more than 45% of efficiency (better than - 3.5dB).
Report No.: BTL-FCCP-4-2509H007 Project No.: 2509H007 Page 1 of 189 Report Version: R01 FCC Radio Test Report FCC ID: X4GS06009 Report No. : BTL-FCCP-4-2509H007 Equipment : Outdoor LTE wireless camera Model Name : AX1054 Brand Name : Axon Applicant : Axon Enterprise, Inc Address : 17800 N. 85th Street, Scottsdale, Arizona 85255, USA Radio Function : RLAN 5 GHz (U-NII 1, U-NII 2A, U-NII 2C, U-NII 3) FCC Rule Part(s) : FCC CFR Title 47, Part 15, Subpart E (15.407) Measurement Procedure(s) : ANSI C63.10-2020 Date of Receipt : 2025/9/11 Date of Test : 2025/10/2 ~ 2025/11/27 Issued Date : 2025/12/9 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Brett Shen, Engineer Approved by : Jerry Chuang, Vice Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-4-2509H007 Project No.: 2509H007 Page 2 of 189 Report Version: R01 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the Customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-4-2509H007 Project No.: 2509H007 Page 3 of 189 Report Version: R01 CONTENTS REVISION HISTORY 5 1 SUMMARY OF TEST RESULTS 6 1.1 TEST FACILITY 7 1.2 MEASUREMENT UNCERTAINTY 7 1.3 TEST ENVIRONMENT CONDITIONS 7 1.4 DUTY CYCLE 8 2 GENERAL INFORMATION 9 2.1 DESCRIPTION OF EUT 9 2.2 TEST MODES 12 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 13 2.4 SUPPORT UNITS 14 3 AC POWER LINE CONDUCTED EMISSIONS TEST 15 3.1 LIMIT 15 3.2 TEST PROCEDURE 15 3.3 DEVIATION FROM TEST STANDARD 15 3.4 TEST SETUP 16 3.5 TEST RESULT 16 4 RADIATED EMISSIONS TEST 17 4.1 LIMIT 17 4.2 TEST PROCEDURE 18 4.3 DEVIATION FROM TEST STANDARD 18 4.4 TEST SETUP 19 4.5 EUT OPERATING CONDITIONS 20 4.6 TEST RESULT – 9 KHZ TO 30 MHZ 20 4.7 TEST RESULT – 30 MHZ TO 1 GHZ 20 4.8 TEST RESULT – ABOVE 1 GHZ 20 5 BANDWIDTH TEST 21 5.1 LIMIT 21 5.2 TEST PROCEDURE 21 5.3 DEVIATION FROM TEST STANDARD 21 5.4 TEST SETUP 21 5.5 EUT OPERATING CONDITIONS 21 5.6 TEST RESULT 21 6 OUTPUT POWER TEST 22 6.1 LIMIT 22 6.2 TEST PROCEDURE 22 6.3 DEVIATION FROM TEST STANDARD 22 6.4 TEST SETUP 22 6.5 EUT OPERATING CONDITIONS 22 6.6 TEST RESULT 22 7 POWER SPECTRAL DENSITY 23 7.1 LIMIT 23 7.2 TEST PROCEDURE 23 7.3 DEVIATION FROM TEST STANDARD 23 7.4 TEST SETUP 23 7.5 EUT OPERATING CONDITIONS 23 7.6 TEST RESULT 23 Report No.: BTL-FCCP-4-2509H007 Project No.: 2509H007 Page 4 of 189 Report Version: R01 8 LIST OF MEASURING EQUIPMENTS 24 9 EUT TEST PHOTO 26 10 EUT PHOTOS 26 APPENDIX A AC POWER LINE CONDUCTED EMISSIONS 27 APPENDIX B RADIATED EMISSIONS - 9 KHZ TO 30 MHZ 32 APPENDIX C RADIATED EMISSIONS - 30 MHZ TO 1 GHZ 37 APPENDIX D RADIATED EMISSIONS - ABOVE 1 GHZ 40 APPENDIX E BANDWIDTH 148 APPENDIX F CONDUCTED OUTPUT POWER 173 APPENDIX G POWER SPECTRAL DENSITY 176 Report No.: BTL-FCCP-4-2509H007 Project No.: 2509H007 Page 5 of 189 Report Version: R01 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-4-2509H007 R00 Original Report. 2025/12/4 Invalid BTL-FCCP-4-2509H007 R01 This report reavised as follow: 1. Revised the scope number in page7. 2. Updated the data in page70~145. 3. Added the Note in page175. lt is a revision of the report BTL-FCCP-4-2509H007 R00. This is a newly released report. replacing the BTL-FCCP-4-2509H007 R00 report. 2025/12/9 Valid Report No.: BTL-FCCP-4-2509H007 Project No.: 2509H007 Page 6 of 189 Report Version: R01 1 SUMMARY OF TEST RESULTS Test procedures according to the technical standards. Standard(s) Section Description Test Result Judgement Remark 15.207 AC Power Line Conducted Emissions APPENDIX A Pass ------ 15.205 15.209 15.407(b) Radiated Emissions APPENDIX B APPENDIX C APPENDIX D Pass ------ 15.407(a) Bandwidth APPENDIX E Pass ------ 15.407(a) Output Power APPENDIX F Pass ------ 15.407(a) Power Spectral Density APPENDIX G Pass ------ 15.203 Antenna Requirement ------ Pass ------ 15.407(c) Automatically Discontinue Transmission ------ Pass NOTE (3) Statement of Conformity The statement of conformity is based on the binary decision rule according to IEC Guide 115 and ILAC G8 "simple acceptance" principle. Without considering measurement uncert…
Text truncated - open the document above for the full version.
Report No.: BTL-FCCP-5-2509H007 Project No.: 2509H007 Page 1 of 39 Report Version: R00 FCC Radio Test Report FCC ID: X4GS06009 Report No. : BTL-FCCP-5-2509H007 Equipment : Outdoor LTE wireless camera Model Name : AX1054 Brand Name : Axon Applicant : Axon Enterprise, Inc Address : 17800 N. 85th Street, Scottsdale, Arizona 85255, USA Radio Function : RLAN 5 GHz (U-NII 2A, UNII-2C) FCC Rule Part(s) : FCC CFR Title 47, Part 15, Subpart E (15.407) (Only DFS) Date of Receipt : 2025/9/11 Date of Test : 2025/10/2 ~ 2025/11/27 Issued Date : 2025/12/4 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Brett Shen, Engineer Approved by : Jerry Chuang, Vice Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-5-2509H007 Project No.: 2509H007 Page 2 of 39 Report Version: R00 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the Customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-5-2509H007 Project No.: 2509H007 Page 3 of 39 Report Version: R00 CONTENTS REVISION HISTORY 4 1 SUMMARY OF TEST RESULTS 5 1.1 REFERENCE TEST GUIDANCE 5 1.2 TEST FACILITY 5 1.3 TEST ENVIRONMENT CONDITIONS 5 2 EUT INFORMATION 6 2.1 EUT SPECIFICATION TABLE 6 2.2 EIRP POWER 8 3 U-NII DFS RULE REQUIREMENTS 9 3.1 WORKING MODES AND REQUIRED TEST ITEMS 9 3.2 TEST LIMITS AND RADAR SIGNAL PARAMETERS 10 4 DYNAMIC FREQUENCY SELECTION (DFS) TEST 13 4.1 DFS MEASUREMENT SYSTEM 13 4.2 CALIBRATION OF DFS DETECTION THRESHOLD LEVEL 20 4.3 DEVIATION FROM TEST STANDARD 20 5 LIST OF MEASURING EQUIPMENTS 21 6 EUT TEST PHOTO 22 7 EUT PHOTOS 22 8 TEST RESULTS 23 8.1 SUMMARY OF TEST RESULT 23 8.2 EST MODE: DEVICE OPERATING IN MASTER MODE. 23 8.3 DFS DETECTION THRESHOLD 24 8.4 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME WLAN TRAFFIC 28 8.5 NON-OCCUPANCY PERIOD 36 Report No.: BTL-FCCP-5-2509H007 Project No.: 2509H007 Page 4 of 39 Report Version: R00 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-5-2509H007 R00 Original Report. 2025/12/4 Valid Report No.: BTL-FCCP-5-2509H007 Project No.: 2509H007 Page 5 of 39 Report Version: R00 1 SUMMARY OF TEST RESULTS Test procedures according to the technical standards. Standard(s) S…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 32.80 mW |
| 2 | 15E | 5.26 GHz - 5.32 GHz | 33.00 mW |
| 3 | 15E | 5.50 GHz - 5.70 GHz | 31.40 mW |
| 4 | 15E | 5.75 GHz - 5.83 GHz | 18.70 mW |
Law Enforcement Training
Equipment Class
DTS - Digital Transmission System
Law Enforcement Training
Equipment Class
DTS - Digital Transmission System
Fleet 3 Wireless Mic
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Fleet Hub
Equipment Class
DTS - Digital Transmission System
AXON Flex Controller
Equipment Class
DTS - Digital Transmission System