X5ALUMT5-AX0DXXLIGHTING FIXTURE

Lumiversal, Inc.
LIGHTING FIXTURE - FCC ID X5ALUMT5-AX0DXX - Lumiversal, Inc.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Oct 09, 2011
Application Purpose
Original Equipment
Date of Application
Oct 09, 2011
Equipment Note
LIGHTING FIXTURE
Frequency Range
0.04500000 - 0.04500000
Company
Lumiversal, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Schematics

Test Report

↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Lighting Fixture Manual Brief Introduction: Lighting Fixture adopts the high efficient electronic ballast and works with tricolor T5 fluorescent tube to realize increasing illumination and energy saving. It’s used to replace the old T8 light fixture with magnetic ballast. It can save over 40-60% energy costs and installation cost. DIY easy installation just like changing a tube and keeping the old light fixture to save installation cost. Through many testing all cost can be taken back in 6 to 12 month. Working chart: The economic adapter is only suitable the first chart(the high quality T5 adapter are suitable for all three.)。 If the economic T5 adapter is used in the connection way like the second chart or the third chart, please cut off the capacitance first. 1 2 3 Installation: This device allows instant savings of energy & emissions and maintenance/service cost, simple Installation 1. Switch Off power 2. Remove the old T8 tube & starter unit from the batten fixture 3. Twist in the T5 adapter & T5 tube securely 4. Switch on power, takes all of 2 minutes and job done...!! Warning: 1、The start can’t be installed again after taken off 2、If the lamp doesn’t work please check it at below: If the connection of holder in good condition If the lamp is with fuse, please check the fuse Please check if the magnetic ballast is workable, if unworkable please ask your electrician to make the magnetic ballast in short circuit FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45–30 MHz.

External Photos

2.1 EUT - Appearance View 2.2 EUT - Special View

ID Label/Location Info

Page 20 of 20 Lumiversal, Inc. FCC ID: X5ALUMT5-AX0DXX WALTEK SERVICES Reference No.: WT10093841-N-E-F 10 FCC Label This device complies with FCC PART 18: 2007 of the FCC Rules. The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. Proposed Label Location on EUT EUT Top View/ proposed FCC Label Location FCC ID: X5ALUMT5-AX0DXX This device complies with Part 18 of the FCC Rules.

ID Label/Location Info

FCC ID Sample for Model: LUMT5-Ax0D/14-U, LUMT5-Ax0D/21-U, LUMT5-Ax0D/28-U, LUMT5-Ax0D/35-U FCC ID: X5ALUMT5-AX0DXX This device complies with Part 18 of the FCC Rules.

Internal Photos

2.1 PCB - Front View 2.2 PCB - Back View

Test Report

FCC TEST REPORT Waltek Services Ref. No.: WT10093841-N-E-F FCC ID : X5ALUMT5-AX0DXX Applicant : Lumiversal, Inc. Address : 500 N. Rainbow Blvd; Suite 300, Las Vegas, NV 89107 Equipment Under Test (EUT) : Product Name : Lighting Fixture Model No. : LUMT5-Ax0D/14-U, LUMT5-Ax0D/21-U, LUMT5-Ax0D/28-U, LUMT5-Ax0D/35-U Standards : FCC CFR47 Part 18 Section 18.305:2009 Date of Test : August 5 ~ August 23, 2011 Date of Issue : October 8, 2011 Test Engineer : Hunk yan Reviewed By : Philo zhong Test Result : PASS Prepared By: Waltek Services (Shenzhen) Co., Ltd. 1/F, Fukangtai Building, West Baima Rd., Songgang Street, Baoan District, Shenzhen 518105, China Tel :+86-755-27553488 Fax:+86-755-27553868 The sample detailed above has been tested to the requirements of Council Directives ANSI C63.4:2003. The test results have been reviewed against the Directives above and found to meet their essential requirements. Page 2 of 20 Lumiversal, Inc. FCC ID: X5ALUMT5-AX0DXX WALTEK SERVICES Reference No.: WT10093841-N-E-F 2 Contents Page 1 COVER PAGE..........................................................................................................................................................1 2 CONTENTS ..............................................................................................................................................................2 3 TEST SUMMARY....................................................................................................................................................3 4 GENERAL INFORMATION..................................................................................................................................4 4.1 CLIENT INFORMATION............................................................................................................................................4 4.2 GENERAL DESCRIPTION OF E.U.T...........................................................................................................................4 4.3 DETAILS OF E.U.T. .................................................................................................................................................4 4.4 DESCRIPTION OF SUPPORT UNITS...........................................................................................................................4 4.5 STANDARDS APPLICABLE FOR TESTING..................................................................................................................4 4.6 TEST METHODOLOGY.............................................................................................................................................4 4.7 TEST FACILITY........................................................................................................................................................5 4.8 TEST LOCATION......................................................................................................................................................5 5 EQUIPMENT USED DURING TEST ...................................................................................................................6 6 CONDUCTED EMISSION TEST ..........................................................................................................................7 6.1 TEST EQUIPMENT....................................................................................................................................................7 6.2 TEST PROCEDURE...................................................................................................................................................7 6.3 CONDUCTED TEST SETUP.......................................................................................................................................8 6.4 EUT OPERATING CONDITION.................................................................................................................................8 6.5 CONDUCTED EMISSION LIMITS...............................................................................................................................9 6.6 SPECTRUM ANALYZER............................................................................................................................................9 6.7 CONDUCTED EMISSION TEST RESULT.....................................................................................................................9 6.8 MEASUREMENT DATA..........................................................................................................................................10 7 RADIATED EMISSIONS TEST ..........................................................................................................................12 7.1 RADIATED EMISSION DATA..................................................................................................................................12 7.2 MEASUREMENT UNCERTAINTY.............................................................................................................................12 7.3 EUT SETUP...........................................................................................................................................................13 7.4 SPECTRUM ANALYZER SETUP...............................................................................................................................13 7.5 TEST PROCEDURE.................................................................................................................................................14 7.6 CORRECTED AMPLITUDE & MARGIN CALCULATION............................................................................................14 7.7 SUMMARY OF TEST RESULTS................................................................................................................................15 8 PHOTOGRAPHS OF TESTING..........................................................................................................................17 8.1 CONDUCTED EMISSIO…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Michael Whittingham(President)
[email protected]702-714-0075Fax: 408-905-8720

Test Firm

Waltek Services(Shenzhen) Co., Ltd.Philo zhong
[email protected]0086-755-27553488Fax: 0086-755-27553868

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.045 MHz - 0.045 MHz-