FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. YOUNGIL ELECTRONICS CO., LTD./
  3. X5OAM-MSC1

X5OAM-MSC1EAS(ELECTRONIC ARTICLE SURVEILLANCE)

YOUNGIL ELECTRONICS CO., LTD.
EAS(ELECTRONIC ARTICLE SURVEILLANCE) - FCC ID X5OAM-MSC1 - YOUNGIL ELECTRONICS CO., LTD.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Feb 18, 2010
Application Purpose
Original Equipment
Date of Application
Feb 18, 2010
Equipment Note
EAS(ELECTRONIC ARTICLE SURVEILLANCE)
Frequency Range
0.05800000 - 0.05800000
Company
YOUNGIL ELECTRONICS CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

I I n n s s t t a a l l l l a a t t i i o o n n M M a a n n u u a a l l ( ( A A M M - - M M S S C C 1 1 ) ) Youngil Electronics Co.,Ltd System Overview. This equipment has 58 KHz performance frequency. And can use all kind of hard tags, soft labels that have 58 KHz resonance frequency. And this equipment manufactures to have perfect compatibility with existing products. This equipment has Transmitter unit, Receive unit, alarm control unit, power unit on antenna interior and reduced occupying space. Also this has very simple installation. You can fix equipment in the floor and connect AC power source, than installation ends. And equipment has factory setting which display most performance. You can do simple tuning process with controller. Controller connected equipment with D-sub connector. And display alarm counter, noise level by real time. Also, do as can control sensitivity of equipment through setting function. It can have correct sensitivity in installation place through this function. <Reference> This manual made for master antenna. (Transmitter, Receiver, Alarm counter, power unit internal type). In case use one master antenna with one slave antenna, is same performance such as that use two master antenna. And it can cost saving is possible than that use two master antenna. (slave type is production available when customer’s request.) Master antenna is built in all function that controlled slave antenna. Slave antenna’s control is achieved through controller that is connected in master antenna. This manual made for master antenna by standard. 1. Install configuration. This system is extended according to way out’s width. Detection distance that offer in one antenna is extension from 80cm (use DR label) to 1.2m (Use ferrite hard tag). Maximum detection area is decided according to number of installed antenna. This system built in all function in one antenna. All function that transmitting, receiving, alarming is work in one antenna. All functions are work normally installing only one antenna. Detection territory of equipment is possible series extension according to number of installed equipment. 1.1 Install configuration method. 1.1.1 Have one entrance, and when width of entrance is within 1meter. The antenna is mounted in the side of door with 1.2meters detecting distance with youngil’s ferrite hard tags. 1.1.2 One entrance, entrance have two doors which have width 1meter. This installation with detection range within 2.4 meters. 1.1.2.1 The antenna mounted in the middle of entrance, with 1.2 meters detection on both side with youngil’s ferrite hard tags. 1.1.2.2 Antenna is mounted in both sides of the entrance and provides the detection distance of 2.4 meters with youngil’s ferrite hard tags. The two antennas use same power line with same phase to synchronize with each other. In this case, does not close the entrance and not to be there is an effect which seems widely. 1.1.3 Two entrance, entrance have four doors which have width 1meter. When being like this, three antennas do in necessary. And to the case which will use the master type antenna the inter-connection cable is not necessary. But in this case antenna is powered by the same power line with the same phase to synchronized with each other’s. If you mounted master with slave antenna, than you must have inter-connection cables between master and slave antennas. 2. Installation method. 2.1 When you arrive at install place. Place the antenna where you have planned for the proper aisle width and to maintain clearance from fixtures that produce interference, and doors that open inward. Distances between antennas depend on tags or labels used with the system. Don’t share the mains AC source with neon signs, motors, computers, cash registers, terminals or data communication equipment. The interference will be able to occur in the equipment with other equipment. As a same reason, equipment use same power lines. If different power lines are supplied to installed antenna, antenna does not operate or false alarm will be occur. Also all power lines must be 3phase power lines has a ground. Please confirm a power lines before installing. Note; We recommended uses the power line which different is separating with other equipment. Attention; Remember to keep system at least 3meters from: - Computer Monitors, TV’s (CRT only). - SMPS (switching mode power supply), neon displays. - Any large metal objects. And we do not recommend that install system under fluorescent light. Note : ONLY if you test system operation to ensure there is no interference. If you detect interference, you must move the components further away from the object causing the interference Use care when you place and install antenna. Let them stand unsupported only as long as required to verify their arrangement and mark mounting holes on the floor. Remember checking the power sources phasing, as they are very important for AM systems. AC power line is connected directly in power unit of the equipment inside. When therefore installation, you must confirm beforehand and prepare according to this of what way power supply consists in equipment, and must prepare. According to power supply method, there is case that must do power construction separately with system installation. In this case, request to customer, power construction should be completed before system installation. This manual does not recorded about power lines work. 2.2 Tools. Tools ; marker, hammer drill, hand drill, hand grinder, hammer, anchor, spanner and other tools. 3. Pre-installation test. 3.1 Test set-up Stand antenna in place that wish to install. Connect to AC power source to system and power ON. CAUTION : Make sure to wire the mains plug correctly to prevent damage the system. 3.2 Check Function. If everything works well (system is factory adjusted) you can test detection, if there are problems see the adjustment procedures for more details. If the system works well and the customer is satisfied wi…

Text truncated - open the document above for the full version.

Cover Letter(s)

YOUNGIL ELECTRONICS CO., LTD. E-Mail : [email protected] Tel. : 82-31-425-6151 Fax. : 82-31-425-6153 Ferbruary 01, 2010 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: X5OAM-MSC1 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Part List CONF APPENDIX – AM-MSC1 - Part List.PDF Schematics Diagram(s) CONF APPENDIX – AM-MSC1 – Schemetics.PDF Block diagram CONF APPENDIX - AM-MSC1 – Block diagramPDF The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, YOUNGIL ELECTRONICS CO., LTD. JONG-BOK CHOL / Manager

External Photos

www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 15 of 21 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. APPENDIX C – EUT Photographs EUT External Photographs www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 16 of 21 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. EUT External Photographs ANT

ID Label/Location Info

www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 21 of 21 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. FCC ID label location

Internal Photos

www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 17 of 21 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. PCB www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 18 of 21 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 19 of 21 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 20 of 21 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD.

Operational Description

Operation description Acousto-Magnetic (AM ,Transceiver System) Acousto-Magnetic systems transmit a radio frequency signal at 58 kHz in a pulsed pattern. The transmit signal energizes an Acoustic-Magnetic tag in the detection zone. When the transmit signal pulse ends, the tag responds, emitting a very distinctive frequency signal, like a tuning fork. While the transmitter is off between pulses the tag signal is detected by the receiver. The ground of the system is commonly connected to the ground for the power supply. The integral antenna, loop coil antenna, is employed. Antenna Antenna

Test Report

www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 1 of 22 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. TEST REPORT For FCC Test Report No. : TK-FR10007 Date of Issue : 02/04/2010 Description of Product : EAS(Electronic Article Surveillance) Model No. : AM-MSC1 Applicant : YOUNGIL ELECTRONICS CO., LTD. 898-27 Hogae-Dong, Dongan-Gu, Anyang-City, Kyunggi-Do, Korea Manufacturer : YOUNGIL ELECTRONICS CO., LTD. 898-27 Hogae-Dong, Dongan-Gu, Anyang-City, Kyunggi-Do, Korea Standards : FCC Part 15 Subpart C Test Date : 01/27/2010 ~ 02/04/2010 Test Results : PASS FAIL The test results relate only to the items tested. Tested by: Reviewed by: Kyu-Chul Shin KT Kang Test Engineer Technical Manager Date:02/04/2010 Date: 02/04/2010 THRU-KES CO.,LTD. 477-6, Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do,469-803, Korea Tel: +82-31-425-6200 / Fax: +82-31-424-0450 www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 2 of 22 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. TABLE OF CONTENTS 1.0 General Product Description ...............................................................................3 1.1 Model Differences .............................................................................................3 1.2 Device Modifications .........................................................................................3 1.3 EUT Configuration(s).........................................................................................4 1.4 EUT Exercise....................................................................................................4 1.5 EUT Operating Mode(s) .....................................................................................4 1.6 Calibration Details of Equipment Used for Measurement .........................................5 1.7 Test Facility......................................................................................................5 1.8 Measurement Procedure ....................................................................................5 2.0 Emissions Test Regulations.................................................................................6 2.1 Radiated Electric Field Emissions.........................................................................7 2.2 Conducted Voltage Emissions – 15.207 .............................................................. 11 APPWNDIX A –Test Equipment Used For Tests ........................................................... 14 APPENDIX B - Test Setup Photos and Configuration ......................................................... 15 Radiated Electric Field Emissions ............................................................................. 15 APPENDIX C – EUT Photographs ................................................................................... 17 EUT External Photographs ...................................................................................... 17 EUT External Photographs ...................................................................................... 18 PCB .................................................................................................................... 19 FCC ID label location .................................................................................................. 23 www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 3 of 22 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. 1.0 General Product Description Product : EAS(Electronic Article Surveillance) Equipment model name : AM-MSC1 Serial number : Prototype Antenna designation :Internal Fixed Antenna Antenna type : Loop Antenna Frequency Range : 58KHz Number of channels : 1 Operating Voltage : AC 115V 1.1 Model Differences Not applicable 1.2 Device Modifications Not applicable www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 4 of 22 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. 1.3 EUT Configuration(s) The following peripheral devices and/or interface cables were connected during the measurement: Peripheral Devices Device Manufacturer Model No. Serial No. FCC ID or DoC EUT YOUNGIL ELECTRONICS CO., LTD. AM-MSC1 - - 1.4 EUT Exercise The calibrated antennas used to sample the radiated field strength are mounted on a non-conductive, motorized antenna mast 3 or 10 meters from the leading edge of the turntable. 1.5 EUT Operating Mode(s) Equipment under test was operated during the measurement under the following conditions: Standby Scrolling ‘H’ Display circles pattern Read / Write Practice operation www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 5 of 22 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. 1.6 Calibration Details of Equipment Used for Measurement Test equipment and test accessories are calibrated on regular basis. The maximum time between calibrations is one year or what is recommended by the manufacturer, whichever is less. All test equipment calibrations are traceable to the Korea Research Institute of Standards and Science (KRISS), therefore, all test data recorded in this report is traceable to KRISS. 1.7 Test Facility THRU-KES Co.,Ltd. (Test Site # : 343818) 477-6, Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do,469-803, Korea 1.8 Measurement Procedure Preliminary radiated emissions test were performed open site (Distance of antenna and EUT was 3 m). To find worst mode, several typical mode and typical cable position were tested and peak level and frequency were recorded. Final radiated emissions test was performed Open Area Test Site. Based on the preliminary tests of the EUT, final test was proceeded worst case test mode and cable configuration. * Measurement procedures was In accordance with ANSI C63.4,ANSI C63.7 www.kes.co.k…

Text truncated - open the document above for the full version.

Test Setup Photos

www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 15 of 22 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. APPENDIX B - Test Setup Photos and Configuration Radiated Electric Field Emissions LOOP ANTENNA www.kes.co.kr Te s t Re p o r t N o. : TK-FR10007 Model No: AM-MSC1 Page 16 of 22 This Report shall not be reproduced except in full without the written approval of THRU-KES CO.,LTD. Conducted Voltage Emissions

Contact Information

Applicant

JONG-BOK CHOI
[email protected]82-31-425-6151Fax: 82-31-425-6153

Test Firm

KES Co., Ltd.In-sung Ryu
[email protected]82-31-425-6200Fax: 82-31-424-0425

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.058 MHz - 0.058 MHz-
Confidentiality
Long Term