FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Yanex Technologies, Inc./
  3. X5URC2Y1

X5URC2Y1UV System Remote Control

Yanex Technologies, Inc.
UV System Remote Control - FCC ID X5URC2Y1 - Yanex Technologies, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 10, 2010
Application Purpose
Original Equipment
Date of Application
Mar 10, 2010
Equipment Note
UV System Remote Control
Frequency Range
433.89000000 - 433.89000000
Company
Yanex Technologies, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Yanex Technologies, Inc. 5407 Foster Ave, Brooklyn, NY 11234 USA toll-free: 800-630-8809 www.yanextech.com YANEX-1 MOBILE PULSE XENON UV ANTIBACTERIAL SYSTEM FOR AIR AND SURFACE DISINFECTION ON PREMISES IN THE ABSENCE OF PEOPLE FOR INDOOR USE ONLY User Manual 2010 1 CONTENTS IMPORTANT SAFETY INFORMATION .................................................................. 2 INTRODUCTION ................................................................................................. 3 PURPOSE OF THE SYSTEM................................................................. 3 COMPONENTS AND FEATURES ........................................................................... 3 PACKAGE CONTENTS....................................................................... 3 LABELS AND MARKINGS.................................................................... 3 PACKING..................................................................................... 3 YANEX-1 SYSTEM DESIGN AND OPERATION............................................. 4 OPERATING INSTRUCTIONS .............................................................................. 7 OPERATING NOTES......................................................................... 7 SAFETY INTERLOCK OVERVIEW........................................................... 7 INTERLOCK INSTALLATION INSTRUCTIONS ............................................. 9 USING THE INTERLOCK.................................................................. 11 OVERVIEW OF YANEX-1 OPERATING PROCEDURES................................... 11 PREPARING THE SYSTEM FOR USE...................................................... 12 STEP-BY-STEP OPERATING INSTRUCTIONS............................................ 12 TRANSPORTATION AND STORAGE ................................................................... 15 TRANSPORTATION........................................................................ 15 STORAGE................................................................................... 15 MAINTENANCE AND SERVICE INFORMATION .................................................. 16 GENERAL DIRECTIONS................................................................... 16 MAINTENANCE PROCEDURES............................................................ 16 TROUBLESHOOTING...................................................................... 17 TECHNICAL SPECIFICATIONS .......................................................................... 18 WARRANTY ...................................................................................................... 18 2 IMPORTANT SAFETY INFORMATION It is important to read and understand this manual. The information it contains helps to protect your safety and prevent problems. This is the safety alert symbol. It is used to alert you of any potential personal injury risks. Obey all instructions that follow this symbol to avoid personal injury. When in emission mode, Yanex-1 produces ultraviolet radiation, which can be harmful for skin and eyes if exposed to. Entering the premises during operation of the device is prohibited. Emission Mode Indicator is located at the left bottom of the front control panel and on the remote control. Under normal circumstances, this indicator should be off at all times when operating personnel or other people are present on premises. If you noticed that this light is blinking, leave room immediately or follow emergency safety instructions below. This device is intended for use only by trained professionals. During device’s operation in the emission mode, presence of people in the room or direct exposure of the eyes and skin to the UV light is not allowed. To avoid burns, do not touch the quartz shield of the flash lamp for 10 minutes after the emission cycle is completed. Concentration of ozone in the treated air occurs with the normal operation of the system. The ozone levels produced do not exceed the maximum permissible values as per OSHA 1910.1000, TABLE Z-1. The scent of ozone usually disappears after 1 to 3 minutes. In a case of emergency, press the STOP button on the control panel of the system or on the remote control. The emission mode will be canceled and the system will return into the standby mode. To switch off the system, turn the key in the activation lock to position β€œ0.” An audio signal will be made and the system will be turned off. If necessary, the system can be shut off by unplugging the power cord from the power source (wall outlet). If you find yourself in the room with the system during emission mode and you do not have the remote control (or cannot unplug the machine), turn away from the lamp and close your eyes. Go as far away from the system as you can (leave the room if possible). Use objects in the room (furniture) to shield yourself from the UV light. Wait for the end of the session. Short-term health consequences may include minor skin/eyes irritation. This device is supplied with door safety interlocks which provide emergency system shut down in the even of accidental room entry. Instructions for interlock set-up and service are explained further in this manual. β€’ β€’ β€’ β€’ β€’ β€’ β€’ β€’ 3 INTRODUCTION PURPOSE OF THE SYSTEM YANEX-1 (also referred to as β€œSystem” or β€œDevice”) is designed to disinfect air and surfaces from microbes (bacteria, spores, viruses, fungi, etc.) and to deodorize rooms during scheduled service and emergency needs. The System can be used in a variety of settings, where it is possible to limit access to the treated area to trained operators only. Such settings include, but are not limited to the following: medical facilities, residential & commercial spaces, industrial facilities, storage facilities, public transportation and others. COMPONENTS AND FEATURES PACKAGE CONTENTS Every YANEX-1 device is supplied with the following components: ο‚·ο€  (1) remote control (with 9V battery included) ο‚·ο€ (1) power cord ο‚·ο€ (2) identical security access keys ο‚·ο€ (1) antenna ο‚·ο€ (1) protective cover ο‚·ο€ (1) user ma…

Text truncated - open the document above for the full version.

ID Label/Location Info

FCC ID Label and Location Remote Control: Location: back of the remote control. Door Safety Interlock: Location: back of the interlock. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: X5URC2Y1 Yanex Technologies, Inc. 1” ο‚± 10% 2.25” ο‚± 10% This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: X5USI2Y1 Yanex Technologies, Inc. 1” ο‚± 10% 2.25” ο‚± 10%

ID Label/Location Info

FCC ID Label and Location Remote Control: Location: back of the remote control. Door Safety Interlock: Location: back of the interlock. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: X5URC2Y1 Yanex Technologies, Inc. 1” ο‚± 10% 2.25” ο‚± 10% This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: X5USI2Y1 Yanex Technologies, Inc. 1” ο‚± 10% 2.25” ο‚± 10%

Test Report

Client: Product Designation: RC2Y1 (Remote Control) / SI2Y1 (Interlock) Report Number: 3197117ATL-001 All services undertaken are subject to the following general policy: This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST, or any agency of the US Government. Tested by: Tests performed by:Report reviewed by: Standard: Shawn K. McGuinness Senior Associate Engineer Troy J. Ihle EMC Project Engineer Yanex Inc. 5407 Foster Avenue Brooklyn, NY 11234 Contact: Gennady Sharovetsky Phone: 800.630.8809 Fax: 800.630.8628 TEST REPORT March 9, 2010 Intertek Testing Services NA Inc. 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 47 CFR Part 15, Subpart C (15.231 - Periodic operation in the band 40.66- 40.70 MHz and above 70 MHz) RSS-210, Issue 7, 2007 Page 1 of 28EMC Report for Yanex Inc. on the RC2Y1 (Remote Control) / SI2Y1 (Interlock) 03/09/2010Report Number: 3197117ATL-001Issued: Intertek 2.0 Test Summary 1.0 Introduction and Conclusion Test DateTest Full NameResultSection System setup including cable interconnection details, support equipment and simplified block diagram. (System Setup)4.0 Overview of EUT (Low Power Transmitters) (FCC 15C - EUT Overview)5.0 01/12/2010Restrictions (FCC 15C - 15.231(a))PASS6.0 01/12/2010Duty Cycle Determination (FCC 15A - 15.35(c))PASS7.0 01/15/2010Radiated Emissions (FCC 15C - 15.231(b))PASS8.0 12/07/2009Bandwidth Requirements (FCC 15C - 15.231(c))PASS9.0 Revision History (Revision History)10.0 Conducted emissions on AC power lines (Conducted Emissions) was waived due to the devices are battery-powered.NA The tests indicated in section 2.0 were performed on the product constructed as described in section 3.0. The remaining test sections are the verbatum text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Page 2 of 28EMC Report for Yanex Inc. on the RC2Y1 (Remote Control) / SI2Y1 (Interlock) 03/09/2010Report Number: 3197117ATL-001Issued: Intertek 3.0 Description of Equipment Under Test Equipment Under Test Description Manufacturer Model Number Serial Number UV System Remote Control Yanex Technologies, Inc. RC2Y1 Prototype UV System Int erlock Yanex Technologies, Inc. SI2Y1 Prototype EUT receive date: 12/7/09 EUT receive condition: Good Description of EUT provided by Client: The transmitters under test are used in controlling a UV disinfection system. Description of EUT exercising: During testing, the provided samples were configured to transmit continuously. Page 3 of 28EMC Report for Yanex Inc. on the RC2Y1 (Remote Control) / SI2Y1 (Interlock) 03/09/2010Report Number: 3197117ATL-001Issued: Intertek System setup including cable interconnection details, support equipment and simplified block diagram. (System Setup) 4.0 Method: Record the details of EUTcabling, document the support equipment, and show the interconnections in a block diagram. EUT Setup Diagram Drawing: Page 4 of 28EMC Report for Yanex Inc. on the RC2Y1 (Remote Control) / SI2Y1 (Interlock) 03/09/2010Report Number: 3197117ATL-001Issued: Intertek System setup including cable interconnection details, support equipment and simplified block diagram. (System Setup) 4.0 Description EUT Cabling Connection Length Shielding FerritesIDFromTo None None Support Equipment DescriptionManufacturerModel NumberSerial Number Data: Page 5 of 28EMC Report for Yanex Inc. on the RC2Y1 (Remote Control) / SI2Y1 (Interlock) 03/09/2010Report Number: 3197117ATL-001Issued: Intertek Overview of EUT (Low Power Transmitters) (FCC 15C - EUT Overview)5.0 Method: Complete the overview spreadsheet. Related Submittal(s) Grants: This report is for use with an application for certification of a low power transmitter. One transmitter is included in the application. Yanex Technologies, Inc. 5407 Fo s ter A v en ue Bro o kly n , NY 11234 Trade Name, Model No. Remote Control and Interlock Device, M/N: RC2Y1 and SI2Y1 FCC Id en t ifier X5URC2Y1 an d X5USI2Y1 Frequency Range (MHz) 433.89 A nten na Typ e (15.203) In teg ral Yanex Technologies, Inc. 214 M ain Street Hemp s tead , NY 11550 Additions, deviations and exclusions from standards This report is for use with an application for certification of a low power transmitter. One transmitter is included in the application. Applicant Manufacturer name & address Related Submittals and Grants: Data: Page 6 of 28EMC Report for Yanex Inc. on the RC2Y1 (Remote Control) / SI2Y1 (Interlock) 03/09/2010Report Number: 3197117ATL-001Issued: Intertek Restrictions (FCC 15C - 15.231(a))6.0 Method: 15.231(a) The provisions of this section are restricted to periodic operation within the band 40.66-40.70 MHz and above 70 MHz. Except as s…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Gennady Sharovetksy
[email protected]800-630-8809Fax: 800-630-8628

Test Firm

Intertek Testing Services NA Inc.Charles Parker
[email protected]972-202-8764Fax: 6787752401

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.89 MHz - 433.89 MHz-
Confidentiality
Long Term

Other Applications from Yanex Technologies, Inc.

UV System Interlock - FCC ID X5USI2Y1 - Yanex Technologies, Inc.
X5USI2Y1

UV System Interlock

Mar 10, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter