FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Senet, Inc./
  3. X94-0005894

X94-0005894LoPower Propane eSensor Transmitter

Senet, Inc.
LoPower Propane eSensor Transmitter - FCC ID X94-0005894 - Senet, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 08, 2015
Application Purpose
Original Equipment
Date of Application
Sep 08, 2015
Equipment Note
LoPower Propane eSensor Transmitter
Frequency Range
433.00000000 - 433.00000000
Company
Senet, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DWG: Propane Install Manual 8.31.15 r1 For More Information Please Contact: Senet, Inc46 River Road, Hudson NH 03051 (603) 821-0003 www.senetco.com Note:This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Modifications:Any modifications made to this device that are not approved by Senet, incmay void the authority granted to the user by the FCC to operate this equipment.

Cover Letter(s)

46 River Road Hudson, NH 03051 PH 603-821-0003 FX 603-821-0199 July 27, 2015 Federal Communications Commission Office of Engineering and Technology 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir, We Senet, Inc. respectfully request that the 433 LoPower Propane eSensor (5894) schematic diagrams, block diagram and circuit description submitted with this application for Certification be withheld from public disclosure pursuant to Sections 0.457 (d) and 0.459 and of the FCC Rules. This request is made under the provisions of Section 0.552 (b) (4) of the Freedom of Information Act. The items listed above contain trade secrets and proprietary information which if disclosed to the public may be harmful to the applicant and place Senet, Inc. at a competitive disadvantage. Thank you for your attention to this matter. Sincerely, Chauncey G. Morgan Chief Financial Officer and Compliance Officer

Cover Letter(s)

Page 1 of 2 46 River Road Hudson, NH 03051 PH 603-821-0003 FX 603-821-0199 July 27, 2015 Retlif Testing Laboratories 101 New Boston Road Goffstown, NH 03045 Attn: Scott Wentworth Ref: AGENT AUTHORIZATION/ANTI-DRUG ABUSE CERTIFICATION Dear Scott, Senet, Inc. hereby authorizes Retlif Testing Laboratories, 101 New Boston Road, Goffstown, NH 03045 to act as our agent in all matters pertaining to FCC Certification of our 0005894 433 LoPower Propane eSensor. Senet Inc. (The Applicant) Certifies that neither Senet, Inc. nor any party to the application is subject to denial of Federal benefits, that include FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a β€œparty” for these purposes. Sincerely, Chauncey G. Morgan Chief Financial Officer & Compliance Officer Page 2 of 2

Test Report

Retlif Testing Laboratories, Test Report R-5980N-2, Senet, Inc. FCC ID: X94-0005894 Technical Information Report Number: R-5980N-2 Customer: Senet, Inc. Address: 46 River Road Hudson, NH 03051 Manufacturer: Senet, Inc. Manufacturer Address: 46 River Road Hudson, NH 03051 Test Sample: LoPower Propane eSensor Transmitter Part Number: 3822 Serial Number: 0003822-000165OC FCC ID: X94-0005894 Power Requirements: 3.6VDC Internal Battery Frequency of Operation: 433 MHz Antenna Type: Non-removable Omni Directional - No Antenna Connector Equipment Use: Measures Propane Tank Level and Sends Data Test Specification: FCC Rules and Regulations Part 15, Subpart C, Section 15.231 Test Procedure: ANSI C63.4:2009 Test Facility: Retlif Testing Laboratories 101 New Boston Road Goffstown, NH 03045 FCC Registered Test Site Number: 90899 1 Retlif Testing Laboratories, Test Report R-5980N-2, Senet, Inc. FCC ID: X94-0005894 Tests Performed The test methods performed on the LoPower Propane eSensor Transmitter are shown below: FCC Part 15, Subpart C Test Method 15.231(e) Field Strength of Emissions – Fundamental 15.231 Duty Cycle Determination 15.231(e) Field Strength of Spurious Emissions 15.231(c) Bandwidth of Emission General Test Requirements 1. The measurement procedures of ANSI C63.4:2009 were utilized as specified in FCC Part 15, Subpart C, Section 15.31(a)(3) and the ANSI C63.4 transition period allowed by the FCC. 2. All radiated emissions measurements were performed on an Open Area Test Site (OATS), listed with the FCC. 3. The level of the fundamental field strength was measured with a new battery installed in the EUT. 4. All measurements were performed at the specified 3 meter test distance as required by FCC Section 15.31(f). 5. The EUT was rotated throughout 360 degrees for all radiated emissions measurements. 6. All readily accessible EUT controls were adjusted in such a manner as to maximize the level of emissions. 7. Appropriate accessories were attached to all EUT ports during the performance of radiated emissions measurements. 8. The EUT was battery powered and AC line conducted emissions were not required. 9. The EUT operated at the frequency of 433 MHz. 10. The frequency spectrum was investigated from the lowest frequency generated in the device up to the 10 th harmonic of the highest fundamental frequency. 11. All measurements were taken with a peak detector function as specified in FCC Section 15.35(a). The duty cycle, calculated in accordance with FCC Section 15.35(c) was applied to the peak readings in order to obtain the average value of emissions. The peak value of emissions was verified to meet the 20 dB requirement of FCC Section 15.35(b). 12. The EUT transmits for a maximum of 1 second once every hour which meets the requirement of 15.231 (e). 2 We equi acco Labo Scot Bran NVL Todd Labo iNAR Non-W The te practic Non- E This te constit produc certify tha ipment sta ordance w oratories pe tt Wentwort nch Manag LAP Approv d Hannema oratory Sup RTE Certifi Warranty Provis esting services h ces. This warran Endorsement est report contain tute a recomme ct endorsement Retlif T at this repo ted. We fu ith the pro ersonnel ta th er ved Signato ann pervisor ed Techni c sion have been perfo ty is in lieu of all ns only findings ndation, endors e by NVLAP or any Testing Lab C ort is a tru urther certif ocedures in king them. ory cian ATL-02 ormed, findings o others, either ex and results arriv ement or certific y agency of the U boratories, T FCC ID Certificatio e represen fy that the ndicated a 255-T obtained and re xpressed or impli ed at after emplo ation of the prod U.S. Governmen Test Repor : X94-0005 on and Sig ntation of t e measurem nd vouch ports prepared i ied. oying the specific duct or material nt. rt R-5980N- 5894 natures the results ments show for the qu in accordance w c test procedure tested. This te s -2, Senet, I obtained wn in this ualifications with generally ac s and standards st report must n nc. from the t report wer s of all Re ccepted laborato s listed herein. It not be used by t tests of the re made in etlif Testing ory principles an is not intended t he client to claim e n g d o m 3 Retlif Testing Laboratories, Test Report R-5980N-2, Senet, Inc. FCC ID: X94-0005894 Requirements and Test Results Requirement: FCC Section 15.231(a) - Periodic operation in the band 40.66 - 40.7 MHz and above 70 MHz The provisions of this Section are restricted to periodic operation within the band 40.66-40.7 MHz and above 70 MHz. Except as shown in Paragraph (e) of this Section, the intentional radiator is restricted to the transmissions of a control signal such as those used with alarm systems, door openers, remote switches, etc. Continuous transmissions, voice, video and the radio control of toys are not permitted. Data is permitted to be sent with a control signal. ο‚· Results: The device was operated at a frequency of 433 MHz and is used to transmit propane tank level data. The device operates in accordance with 15.231 (e). Requirement: FCC Sections 15.231(a)(1)-(5) Periodic operation in the band 40.66 - 40.7 MHz and above 70 MHz The following conditions were met in order to comply with the provisions for momentary operation: FCC 15.231(a)(1): A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. ο‚· Results: The device is not manually operated. FCC 15.231(a)(2): A transmitter activated automatically shall cease transmission within 5 seconds after activation. ο‚· Results: The device will transmit for 25.05 msec after activation and cease transmission. 4 Retlif Testing Laboratories, Test Report R-5980N-2, Senet, Inc. FCC ID: X94-0005894 Requirements and Test Results (con’t) FCC 15.231(a)(3): Periodic transmissions at regular predetermined intervals are not permitted. However, polling or supervision transmissions, including data, to determine system integrity of transmitters used in security or…

Text truncated - open the document above for the full version.

Test Setup Photos

Retlif Testing Laboratories, Test Report R-5980N-2, Senet, Inc. FCC ID: X94-0005894 Test Photograph(s) Field Strength of Emissions – Fundamental Horizontal Antenna Polarization Vertical Antenna Polarization 11 Retlif Testing Laboratories, Test Report R-5980N-2, Senet, Inc. FCC ID: X94-0005894 Test Photograph(s) Duty Cycle Determination Test Setup 12 Retlif Testing Laboratories, Test Report R-5980N-2, Senet, Inc. FCC ID: X94-0005894 Test Photograph(s) Field Strength of Spurious Emissions Horizontal Polarization, 30 MHz to 1 GHz Vertical Polarization, 30 MHz to 1 GHz 13 Retlif Testing Laboratories, Test Report R-5980N-2, Senet, Inc. FCC ID: X94-0005894 Test Photograph(s) Field Strength of Spurious Emissions Horizontal Polarization, 1 GHz to 4.4 GHz Vertical Polarization, 1 GHz to 4.4 GHz 14 Retlif Testing Laboratories, Test Report R-5980N-2, Senet, Inc. FCC ID: X94-0005894 Test Photograph(s) Bandwidth of Emission Test Setup 15

Contact Information

Applicant

Brad Martin(COO & Chief Compliance Officer)
[email protected]603-821-0003Fax: 603-821-0199

Technical Contact

Retlif Testing LaboratoriesScott Wentworth
[email protected]6034974600

101 New Boston Rd. Β· Goffstown, New Hampshire Β· United States

Non-Technical Contact

Retlif Testing LaboratoriesScott Wentworth
[email protected]6034974600

Test Firm

Retlif Testing LaboratoriesScott Wentworth
[email protected]631-497-4600Fax: 631-497-5281

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)433 MHz - 433 MHz-
Confidentiality
Long Term

Other Applications from Senet, Inc.

LoPower Oil eSensor Transmitter - FCC ID X94-0005895 - Senet, Inc.
X94-0005895

LoPower Oil eSensor Transmitter

Sep 08, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Senet LoRa Basestation - FCC ID X94-0005845 - Senet, Inc.
X94-0005845

Senet LoRa Basestation

May 13, 2015

Equipment Class

DTS - Digital Transmission System
LoRa eSensor Propane Transmitter - FCC ID X94-0005847 - Senet, Inc.
X94-0005847

LoRa eSensor Propane Transmitter

Mar 11, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
LoRa eSensor Oil Transmitter - FCC ID X94-0005848 - Senet, Inc.
X94-0005848

LoRa eSensor Oil Transmitter

Mar 11, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Oil Tank Transmitter - FCC ID X94-0005618REVB00 - Senet, Inc.
X94-0005618REVB00

Oil Tank Transmitter

Jan 07, 2014

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter