Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
140 Business Park Drive Winston–Salem, NC USA 27107 877.874.8774 www.vervelivingsystems.com April 15, 2010 AmericanTCB 6731 Whittier Avenue McLean VA 22101 Attn: Director of Certification Dear Sir or Madam We, Liberty Hardware Manufacturing Corporation [140 Business Park Drive, Winston-Salem, NC 27107], are requesting Limited Modular Approval (LMA) on the PTM 240C and hereby declare that the PTM 240C will only be integrated into Liberty Hardware Manufacturing Corporation products. Therefore, Liberty Hardware Manufacturing Corporation will retain full control of final installation No manual exists for this product since Liberty Hardware Manufacturing Corporation is the integrator. However, the following regulatory notices will be included in the end product manuals. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device contains FCC ID: X98-PTM240C / IC: 8907A-PTM240C CAUTION: Changes or modifications not expressly approved by Liberty Hardware Manufacturing Corporation could void the user’s authority to operate the equipment. In addition, the wording “Contains FCC ID: X98-PTM240C / IC: 8907A-PTM240C” will be included on the label of the device in which the PTM 240C is installed. Sincerely David M. Burke Associate Principal Engineer 313.792.4269 313.792.4325 [email protected]
140 Business Park Drive Winston–Salem, NC USA 27107 877.874.8774 www.vervelivingsystems.com April 15, 2010 AmericanTCB 6731 Whittier Avenue McLean VA 22101 Attn: Director of Certification Dear Sir or Madam We, Liberty Hardware Manufacturing Corporation [140 Business Park Drive, Winston-Salem, NC 27107], are requesting Limited Modular Approval (LMA) on the PTM 240C and hereby declare that the PTM 240C will only be integrated into Liberty Hardware Manufacturing Corporation products. Therefore, Liberty Hardware Manufacturing Corporation will retain full control of final installation No manual exists for this product since Liberty Hardware Manufacturing Corporation is the integrator. However, the following regulatory notices will be included in the end product manuals. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device contains FCC ID: X98-PTM240C / IC: 8907A-PTM240C CAUTION: Changes or modifications not expressly approved by Liberty Hardware Manufacturing Corporation could void the user’s authority to operate the equipment. In addition, the wording “Contains FCC ID: X98-PTM240C / IC: 8907A-PTM240C” will be included on the label of the device in which the PTM 240C is installed. Sincerely David M. Burke Associate Principal Engineer 313.792.4269 313.792.4325 [email protected] 140 Business Park Drive Winston–Salem, NC USA 27107 877.874.8774 www.vervelivingsystems.com April 29, 2010 AmericanTCB 6731 Whittier Avenue McLean VA 22101 Attn: Director of Certification RE: FCC ID: X98-PTM240C / IC: 8907A-PTM240C submittal as modular device 1. The modular transmitter must have its own RF shielding. This is intended to ensure that the module does not have to rely upon the shielding provided by the device into which it is installed in order for all modular transmitter emissions to comply with FCC Part 15 and Industry Canada limits. It is also intended to prevent coupling between the RF circuitry of the module and any wires or circuits in the device into which the module is installed. Such coupling may result in non-compliant operation. The modular transmitter has a ground plane and other grounding elements that are designed to provide adequate shielding; it was tested in a stand-alone configuration and the measurements confirmed the effectiveness of the ground plane shield. The modular transmitter complies with Part 15 emissions limits. 2. The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with Part 15 and Industry Canada requirements under conditions of excessive data rates or over-modulation. The modular transmitter has buffered modulation/data inputs. 3. The modular transmitter must have its own power supply regulation. This is intended to ensure that the module will comply with Part 15 and Industry Canada requirements regardless of the design of the power supplying circuitry in the device into which the module is installed. The modular transmitter has its own power supply regulation. 4. The modular transmitter must comply with the antenna requirements of FCC Sections 15.203 and 15.204(c) and Industry Canada requirements. The antenna must either be permanently attached or employ a “unique” antenna coupler (at all connections between the module and the antenna, including the cable). Any antenna used with the module must be approved with the module, either at the time of initial authorization or through a Class II permissive change. The “professional installation” provision of FCC Section 15.203 may not be applied to modules. The modular transmitter has a permanently attached antenna. 5. The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing. This is intended to demonstrate that the module is capable of complying with FCC Part 15 and Industry Canada emission limits regardless of the device into which it is eventually installed. Unless the transmitter module will be battery powered, it must comply with the AC line conducted requirements found in FCC Section 15.207. AC or DC power lines and data input/output lines connected to the module must not contain ferrites, unless they will be marketed with the module (see FCC Section 15.27(a)). The length of these lines shall be length typical of actual use or, if that length is unknown, at least 10 centimeters to insure that there is no coupling between the case of the module and supporting equipment. Any accessories, peripherals, or support equipment 140 Business Park Drive Winston–Salem, NC USA 27107 877.874.8774 www.vervelivingsystems.com connected to the module during testing shall be unmodified or commercially available (see FCC Section 15.31(i)). The modular transmitter was tested in a stand-alone configuration and complies with Part 15 emissions limits. 6. The modular transmitter must be labeled with its own FCC ID / IC number, and, if the FCC ID / IC number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: XYZMODEL1 / IC: XXX-YYYY” or “Contains FCC ID: XYZMODEL1 / IC: XXX-YYYY.” Any similar wording that expresses the same meaning may be used. The Applicant may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. The modular transmitter is labeled with its own FCC…
Text truncated - open the document above for the full version.
140 Business Park Drive Winston–Salem, NC USA 27107 877.874.8774 www.vervelivingsystems.com April 15, 2010 AmericanTCB 6731 Whittier Avenue McLean VA 22101 Attn: Director of Certification Dear Sir or Madam: We, Liberty Hardware Manufacturing Corporation [140 Business Park Drive, Winston-Salem, NC 27107], hereby authorize TÜV America Inc [19333 Wild Mountain Road, Taylors Falls, MN USA 55084-1786] to act as our agent in preparation of this application for equipment certification, including the signing of all documents relating to these matters. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as required by FCC's and Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by AmericanTCB, still resides with Liberty Hardware Manufacturing Corporation [140 Business Park Drive, Winston-Salem, NC 27107]. I further certify that the applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862. This authorization expires on April 15, 2011. Sincerely, David M. Burke Associate Principal Engineer 313.792.4269 313.792.4325 [email protected]
TOP BOARD VIEW BOTTOM BOARD VIEW TOP BOARD VIEW BOTTOM BOARD VIEW
TOP BOARD VIEW BOTTOM BOARD VIEW TOP BOARD VIEW BOTTOM BOARD VIEW
USER MANUAL V1.01 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 [email protected] www.enocean.com Subject to modifications PTM 240C User Manual V1.01 September 26, 2008 4:13 PM Page 1/11 Patent protected: WO98/36395 DE 100 25 561 DE 10309334 Transmitter Module 315MHz PTM 240C September 26, 2008 USER MANUAL V1.01 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 [email protected] www.enocean.com Subject to modifications PTM 240C User Manual V1.01 September 26, 2008 4:13 PM Page 2/11 PTM 240C REVISION HISTORY The following major modifications and improvements have been made to the first version of this document: No Major Changes 0.97 Documentation of energy pulse requirements extended 0.98 Energy pulse requirements corrected. Polarity is important! 1.00 Product released to serial production 1.01 Timing requirement for SW1, SW2 modified in section 2.2 Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany www.enocean.com, [email protected], phone ++49 (89) 6734 6890 © EnOcean GmbH All Rights Reserved Important! This information describes the type of component and shall not be considered as assured characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest product specifica- tions, refer to the EnOcean website: http://www.enocean.com. As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not for the described applications, processes and circuits. EnOcean does not assume responsibility for use of modules described and limits its liability to the replacement of modules determined to be defective due to workmanship. Devices or systems containing RF components must meet the essential requirements of the local legal authorities. The modules must not be used in any relation with equipment that supports, directly or indirectly, human health or life or with applications that can result in danger for people, animals or real value. Components of the modules are considered and should be disposed of as hazardous waste. Local government regulations are to be observed. Packing: Please use the recycling operators known to you. By agreement we will take pack- ing material back if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or that we are not obliged to accept, we shall have to in- voice you for any costs incurred. USER MANUAL V1.01 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 [email protected] www.enocean.com Subject to modifications PTM 240C User Manual V1.01 September 26, 2008 4:13 PM Page 3/11 PTM 240C TABLE OF CONTENT 1 GENERAL DESCRIPTION...................................................................................... 4 1.1 Functional Principle........................................................................................ 4 1.2 Features Overview ........................................................................................ 4 1.3 Mechanical Interface...................................................................................... 5 1.4 Environmental Conditions ............................................................................... 5 1.5 Ordering Information ..................................................................................... 5 2 FUNCTIONAL DESCRIPTION................................................................................. 6 2.1 Block Diagram .............................................................................................. 6 2.2 Pin Description and operational characteristics .................................................. 6 2.3 PTM 240C Radio Telegram .............................................................................. 7 2.3.1 Transmission timing ................................................................................... 7 2.3.2 Telegram Data........................................................................................... 7 2.4 Energy Pulse Requirements ............................................................................ 8 3 APPLICATIONS INFORMATION ............................................................................. 9 3.1 Antenna Mounting ......................................................................................... 9 3.2 Transmission Range .....................................................................................10 3.3 FCC/IC Approval Requirements ......................................................................11 USER MANUAL V1.01 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 [email protected] www.enocean.com Subject to modifications PTM 240C User Manual V1.01 September 26, 2008 4:13 PM Page 4/11 PTM 240C 1 GENERAL DESCRIPTION The radio transmitter module PTM 240C from EnOcean enables the implementation of batteryless occupancy sensors for applications in building technology. Power is provided by an external short energy pulse. The PTM 240C module serves the 315 MHz air interface protocol of EnOcean. Together with the transceiver module TCM2xyC, this module can be easily integrated in operation and control units for the implementation of different application specific system solutions. 1.1 Functional Principle When a short energy pulse is supplied to the PTM 240C module an RF telegram is transmit- ted including a 32-bit module ID. In addition the information of 2 inputs is transmitted. These inputs shall be used in the application circuitry to connect a learn button and the evaluation unit of a passive infrared sensor (PIR). 1.2 Features Overview Power supply external voltage pulse Frequency / Transmission power 315.0 MHz / typ. 3 dBm conducted Data rate / Modulation type 125 kbps / ASK Minimal switc…
Text truncated - open the document above for the full version.
TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 TEST RESULT SUMMARY FCC Part 15 Subpart C Section 15.231 Industry Canada RSS-210 Issue 7 MANUFACTURER Liberty Hardware Manufacturing Corp 7500 Holland Road Taylor MI 48180 EUT DESCRIPTION 315 MHz transmitter module EUT NAME PTM240C MODEL NUMBER(S) TESTED PTM240C SERIAL NUMBER(S) TESTED n/a TEST REPORT NUMBER WC1002659 TEST DATE(S) 13 April 2010 TÜV SÜD America Inc, as an independent testing laboratory, declares that the equipment tested as specified above conforms to the applicable requirements of FCC Part 15, Subpart C, Section 15.231 "Periodic operation in the band 40.66 - 40.70 MHz and above 70 MHz” and Industry Canada RSS-210 Issue 7 "Low-power Licence-exempt Radiocommunication Devices (All Frequency Bands): Category I Equipment" Annex 1 “Momentarily Operated Devices” It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical characteristics. Any modifications necessary for compliance made during testing on the above mentioned date(s) must be implemented in all production units for compliance to be maintained. Date: 27 April 2010 Tested by: Approved by: Location: Taylors Falls MN Joel T Schneider Greg S Jakubowski USA Senior EMC Engineer Senior EMC Technician Not Transferable TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 EMC TEST REPORT Test Report File No. : WC1002659 Date of issue: 27 April 2010 Manufacturer Liberty Hardware Manufacturing Corp Address 7500 Holland Road Taylor MI 48180 Description of Equipment 315 MHz transmitter module Name of Equipment PTM240C Model No(s) Tested PTM240C Serial No(s) Tested n/a Test Result Positive Negative TÜV SÜD America Inc reports apply only to the specific samples tested under stated test conditions. It is the manufacturer’s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. TÜV SÜD America Inc shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD America Inc issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. This report shall not be used by the client to claim product endorsement by NVLAP, NIST, or any agency of the US government. TÜV SÜD America Inc and its professional staff hold government and professional organization certifications and are members of AAMI, ACIL, AEA, ANSI, IEEE, NARTE, and VCCI. Test Report WC10026591 of 29 TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 REVISION RECORD REVISION TOTAL NUMBER OF PAGES DATE DESCRIPTION 29 27 April 2010 Initial Release Test Report WC10026592 of 29 TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 TEST REPORT CONTENTS Page(s) Revision Record 2 Directory 3 Test Regulations 4 Environmental Conditions 5 Power Supply 5 Test Equipment Traceability 5 Test Information Activation time FCC 15.231(a)(1)-(2), RSS 210 A1.1.1(1)-(2) 6 - 7 Periodic transmissions FCC 15.231(a)(3), IC RSS-210 A1.1.1(3) 8 Set-up information for security systems FCC 15.231(a)(5) 9 Radiated emissions FCC 15.231(b), IC RSS-210 A1.1.2 10 - 13 Bandwidth FCC 15.231(c), IC RSS-210 A1.1.3 14 - 15 Conducted emissions FCC 15.207, IC RSS-GEN 7.2.2 16 Test Set-up Photos 17 - 18 Equipment Under Test Information 19 General Remarks, Deviations, Summary 20 Appendix A Constructional Data Form and Block Diagram 21 - 27 Appendix B Measurement Protocol 28 - 29 Test Report WC10026593 of 29 TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 EMC TEST REGULATIONS: The tests were performed according to the following regulations: - FCC Part 15 Subpart C Section 15.231 - Industry Canada RSS-210 Issue 7 Annex 1 Test Report WC10026594 of 29 TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 ENVIRONMENTAL CONDITIONS IN THE LAB Actual Temperature: : 21°C Relative Humidity : 30 % Atmospheric pressure : 99 kPa POWER SUPPLY UTILIZED Power supply system : 3.3 VDC TEST EQUIPMENT All measurement instrumentation is traceable to the National Institute of Standards and Technology and is calibrated according to internal procedure. SIGN EXPLANATIONS - not applicable - applicable Test Report WC10026595 of 29 TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 Activation time FCC 15.231(a)(1) - IC RSS 210 A1.1.1(1) Test limit A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. Test summary The requirements are: - MET - NOT MET - NOT APPLICABLE The transmitter is not manually operated. FCC 15.231(a)2), IC RSS 210 A1.1.1(2) Test limit A transmitter activated automatically shall cease transmission within 5 seconds after activation Test summary The requirements are: - MET - NOT MET The transmitter activates automatically and does cease transmission within 5 seconds after activation Test location - Oakwood Lab - Wild River Lab Small Test Site (Open Area Test Site) Test equipment TUV ID Model Manufacturer Description Serial Cal Due WRLE10435 E4440A Agilent Spectrum Analyzer MY44304483 28-Jul-10 Test data See plot on next page Test Report WC10026596 of 29 TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 Test Report WC10026597…
Text truncated - open the document above for the full version.
TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 Test Setup Photo - Field strength of emissions FCC 15.231(b) - IC RSS 210 A1.1.2 Test Report WC100265917 of 29 TÜV SÜD AMERICA INC19333 Wild Mountain Road Taylors Falls MN 55084-1786 Tel: 651 638 0297 Fax: 651 638 0298 Rev. 080408 Test Setup Photo - Field strength of emissions FCC 15.231(b) - IC RSS 210 A1.1.2 Test Report WC100265918 of 29
19333 Wild Mountain Road · Taylor Falls, Minnesota · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |