Application Details

Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Date of Grant
May 10, 2012
Application Purpose
Original Equipment
Date of Application
May 10, 2012
Equipment Note
Two Way Radio
Frequency Range
406.10000000 - 470.00000000
Company
BOND TELECOMMUNICATION CO., LIMITED.
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SAFETYTRAINING INFORMATION Yo u r BOND TELECOMMUNICATION CO., LIMITED radio generates RF electromagnetic energy during transmit mode. This radio is designed for and classified as “Occupational Use Only”, meaning it must be used only during the course of employment by individuals aware of the hazards, and the ways to minimize such hazards. This radio is NOT intended for use by the “General Population” in an uncontrolled environment. This radio has been tested and complies with the FCC RF exposure limits for “Occupational Use Only”. In addition, your BOND TELECOMMUNICATION CO., LIMITED radio complies with the following Standards and Guidelines with regard to RF energy and electromagnetic energy levels and evaluation of such levels for exposure to humans:  FCC OET Bulletin 65 Edition 97-01 Supplement C, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields.  American National Standards Institute (C95.1-1992), IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz.  American National Standards Institute (C95.3-1992), IEEE Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields– RF and Microwave.  The following accessories are authorized for use with this product. Use of accessories other than those (listed in the instruction) specified may result in RF exposure levels exceed the FCC requirements for wireless RF exposure. To ensure that your expose to RF electromagnetic energy is within the FCC allowable limits for occupational use, always adhere to the following guidelines:  DO NOT operate the radio without a proper antenna attached, as this may damaged the radio and may also cause you to exceed FCC RF exposure limits. A proper antenna is the antenna supplied with this radio by the manufacturer or antenna specifically authorized by the manufacturer for use with this radio.  DO NOT transmits for more than 50% of total radio use time (“50%duty cycle”). Transmitting more than 50% of the time can cause FCC RF exposure compliance requirements to be exceeded. The radio is transmitting when the “TX indicator” lights red. You can cause the radio to transmit by pressing the “PTT” switch.  ALWAYS keep the antenna at least 2.5 cm (1 inch) away from the body when transmitting and only use the HYT belt-clip which is listed in instructions when attaching the radio to your belt, etc., to ensure FCC RF exposure compliance requirements are not exceeded. To provide the recipients of your transmission the best sound quality, hold the antenna at least 5 cm (2 inches) from your mouth, and slightly off to one side. T he information listed above provides the user with the information needed to make him or her aware of RF exposure, and what to do to as‐sure that this radio operates with the FCC RF exposure limits of this radio. Electromagnetic Interference/Compatibility During transmissions, your BOND TELECOMMUNICATION CO., LIMITED radio generates RF energy that can possibly cause interference with other devices or systems. To avoid such interference, turn off the radio in areas where signs are posted to do so. DO NOT operate the transmitter in areas that are sensitive to electromagnetic radiation such as hospitals, aircraft, and blasting sites. Occupational/Controlled Use The radio transmitter is used in situations in which persons are exposed as consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure.

Cover Letter(s)

May PH O Koen D‐32 Germ Su b FCC tran Gen t The Pro g or b usin y 2, 2012 OENIX TESTLA nigswinkel 10 2825 Blombe many bject: C ID: X9MDT nsmitter. tlemen; equipment m gramming of by service or g the equip m AB GmbH 0 rg, TBOND Att meets the req this product’ maintenance ment’s externa estation st a quirements of ’s transmit fre e personal. T al operation atement tha f the FCC Rul equencies ca The operator controls. BOND T at the end u es, Part 90.20 n be perform r cannot be p TELECOMM user can’t tu 03(e) and (g), med ONLY by program tran MUNICATION Lou une the , as applicabl the manufac nsmit freque N CO., LIMI uisBondWu/G e. turer ncies TED G.M.

Cover Letter(s)

May 2, 2012 Federal Communication Commission Authorization and Evaluation Division FCC ID: X9MDTBOND Re: Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the applicant hereby requests confidential treatment of information applied this application as outlined below: 1: Block Diagram 2: Circuit Diagram 3: Operational Description 4: Parts List 5:Tune Up Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rules 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, BOND TELECOMMUNICATION CO., LIMITED LouisBondWu/G.M.

Cover Letter(s)

ou ex c the Si n Lou BO FLAT A1, We, BON r device cept the e users a ncerely y uisBondWu OND TEL WZ, 15/F STRAN Tel: 852 ND TELE , FCC ID batter y as they p yours, u/G.M. LECOMM HILLIER C ND EAST, S 2‐63524 St ECOMMU : X9MDT y compar purchase MUNICA COMMERC SHEUNG 4346; FAX tateme UNICATI TBOND, rtment o e the pro ATION CO CIAL BUILD WAN HON X: 852‐6 ent ION CO., has no s of this d ducts an O., LIMI DING, 65-6 NGKONG. 6352434 D , LIMITE space to device. It nd instal TED 67 BONHA 46 Date: May 2 ED states put the t is visib ll the bat AM 2, 2012 s that label ble to ttery.

External Photos

TOP VIEW OF EUT BOTTOM VIEW OF EUT LEFT VIEW OF EUT RIGHT VIEW OF EUT FRONT VIEW OF EUT BACK VIEW OF EUT ALL VIEW OF EUT

ID Label/Location Info

FCC ID Label Location Product Name FCC RF Warning Label Two way radio FCC ID : X9MDTBOND Brand :LUITON,Duet Model : LT‐303,DT‐303 Frequency Range : 400MHz to 470MHz

Internal Photos

OPEN VIEW OF EUT INTERNAL VIEW OF EUT – 1 INTERNAL VIEW OF EUT – 2 Internal View of EUT – 3 Internal View of EUT – 4

RF Exposure Info

SAR Test Report Report No.: AGC06X120401S1 FCC ID : X9MDTBOND Product Designation : Two way radio Brand Name : LUITON, DUET Model Name : LT-303; DT-303 Client : BOND TELECOMMUNICATION CO., LIMITED. Date of Issue : Apr.20, 2012 STANDARD(S) : FCC Oet65 Supplement C June 2001 IEEE Std. 1528-2003,47CFR § 2.1093 Attestation of Global Compliance Co., Ltd. CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. Applicant Applicant Manufact Manufact Product N Brand Na Model Na Differenc EUT Volta Applicabl Te s t D a te Te s t R e su Performe t Name t Address turer Name turer Addres Name ame ame e Descriptio age e Standard e ults ed Location Test : BO : FL A BO : Bon ss : 82 0 362 : Two : LUI : LT- on Th e mo : DC : FCC IEE : Ap r : MA Hea Bod : Att e 1F. Xix Tested Checke d Authorize t Repo OND TELECO AT A1, WZ, ONHAM STR nd Telecom 0#, Internatio 2000, Fujian o way radio ITON, DUET 303; DT-303 e two mode del names. C 7.4V by bat C Oet65 Su EE Std. 1528 r.19, 2012 AX SAR MEA ad: 3.380 W dy: 4.626 W estation of G , No.2 Build iang, Baoan By d By ed By ort Ce OMMUNICA 15/F HILLIE RAND EAST Co., Ltd. on City Bloc n, China T 3 els are the s ttery pplement C 8-2003,47CF ASUREMEN W/Kg(with 5 W/Kg(with 5 Global Comp ding, Huafe n District, Sh Angela L Forrest L Solger Zh a ertifica ATION CO., ER COMMER T, SHEUNG W ck, Citong Rd same, only June 2001 FR § 2.10 NT(1g) 50% duty cyc 0% duty cyc pliance Co.( ng No.1 Te henzhen Li A Lei A ang A Report N ation LIMITED. RCIAL BUIL WAN HONG d, Fengze D have differe 93 cle) cle) Shenzhen), echnical Ind Apr.20, 2012 Apr.20, 2012 Apr.20, 2012 No.: AGC06 P LDING, 65-6 GKONG. District, Quan ent brand na Ltd. ustrial Park 6X120401S1 Page 2 of 66 67 nzhou ames and k, Sanwei, 1 Report No.: AGC06X120401S1 Page 3 of 66 TABLE OF CONTENTS 1. GENERAL INFORMATION ............................................................................................................................ 5 1.1. EUT DESCRIPTION .................................................................................................................................... 5 1.2. TEST PROCEDURE ................................................................................................................................... 5 1.3. TEST ENVIRONMENT ................................................................................................................................ 5 2. SAR MEASUREMENT SYSTEM ..................................................................................................................... 6 2.1. COMOSAR SYSTEM DESCRIPTION ......................................................................................................... 6 2.1.2. AREA SCANS ........................................................................................................................................... 7 2.1.3. ZOOM SCAN (CUBE SCAN AVERAGING) .............................................................................................. 7 2.2.1. ISOTROPIC E-FIELD PROBE SPECIFICATION ..................................................................................... 8 2.3. BOUNDARY DETECTION UNIT AND PROBE MOUNTING DEVICE ......................................................... 8 2.4. DATA ACQUISITION ELECTRONICS (DAE) AND MEASUREMENT SERVER .......................................... 9 2.5 ROBOT ........................................................................................................................................................ 8 2.6. VIDEO POSITIONING SYSTERM .............................................................................................................. 9 2.7. DEVICE HOLDER ....................................................................................................................................... 9 2.8. ELLIPTICAL PHANTOM ............................................................................................................................ 10 3. TISSUE SIMULATING LIQUID ..................................................................................................................... 11 3.1. THE COMPOSITION OF THE TISSUE SIMULATING LIQUID .............................................................................. 11 3.2. TISSUE CALIBRATION RESULT .................................................................................................................................. 11 3.3. TISSUE DIELECTRIC PARAMETERS FOR HEAD AND BODY PHANTOMS ................................................. 12 4. SAR MEASUREMENT PROCEDURE ......................................................................................................... 13 4.1. SAR SYSTEM VALIDATION .......................................................................................................................................... 13 4.1.1. VALIDATION DIPOLES ............................................................................................................................................... 13 4.1.2. VALIDATION RESULT ................................................................................................................................................. 14 4.2. SAR MEASUREMENT PROCEDURE ........................................................................................................................ 15 5. SAR EXPOSURE LIMITS ............................................................................................................................ 16 6. TEST EQUIPMENT LIST ............................................................................................................................. 17 7. MEASUREMENT UNCERTAINTY ................................................................................................................ 18 Report No.: AGC06X120401S1 Page 4 of 66 8. CONDUCTED POWER MEASUREMENT ............................................................…

Text truncated - open the document above for the full version.

Test Report

FCC Part 90 Test Report Report No.: AGC06X120401F1 FCC ID : X9MDTBOND PRODUCT DESIGNATION : Two way radio BRAND NAME : LUITON, Duet TEST MODEL : LT‐303, DT‐303 CLIENT : BOND TELECOMMUNICATION CO., LIMITED DATE OF ISSUE : Apr. 19, 2012 STANDARD(S) : FCC Part 90 Rules Attestation of Global Compliance Co., Ltd. CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. V A M P B T S D F D W p g t h VERIFICA Applicant: Manufacture Product Des Brand Name Test model: Serious mod Difference de File Number Date of Test: We hereb The abo rocedures, a iven in ANS he FCC Rule The test ATION O er: cription: e: del: escription: : : by certify ove equipme and equipm SI C 63.4:200 es Part 90 re results of th F COMP BOND FLAT A EAST, Bond T 820#, I Fujian, Two wa LUITO DT-303 LT-303 All the LT-30 3 AGC06 Apr. 12 y that: ent was teste ment configur 03 and TIA/E equirements his report re Te s t e Revi e Approv LIANCE TELECOMM A1, WZ, 15/F SHEUNG W Telecommun nternation C China ay radio N, Duet 3 3 same excep 3 is correspo 6X120401F1 2, 2012 to Ap ed by Attest rations show EIA 603. The s. late only to t d By: ew By ved By MUNICATIO F HILLIER C WAN HONG nication Co., City Block, C pt for the mo onding to LU 1 pr. 18, 2012 tation of Glo wn in this re e sample tes the tested s Curoky C h Forrest Le Solger zha ON CO., LIM COMMERCI KONG. Ltd Citong Rd, F odel name a UITON, DT-3 obal Complia port were m sted as desc ample ident hen Ap ei Ap ang Ap MITED AL BUILDIN Fengze Distr and brand na 303 is corres ance Co., Lt made in acco cribed in this tified in this r pr. 19, 2012 pr. 19, 2012 pr. 19, 2012 Report No.: NG, 65-67 B rict, Quanzho ame, sponding to td. The data ordance with s report is in report. AGC06X1204 Page 1 ONHAM ST ou 362000, Duet. a evaluation h the proced compliance 401F1 of 50 TRAND , test dures e with Report No.: AGC06X120401F1 Page 2 of 50 TABLE OF CONTENTS 1. GENERAL INFORMATION ............................................................................................. 4 1.1 PRODUCT DESCRIPTION ....................................................................................................................... 4 1.3 TEST METHODOLOGY ........................................................................................................................... 5 1.4 TEST FACILITY ........................................................................................................................................ 5 1.5 SPECIAL ACCESSORIES ....................................................................................................................... 5 1.6 EQUIPMENT MODIFICATIONS ............................................................................................................... 5 2. SYSTEM TEST CONFIGURATION ................................................................................. 6 2.1 EUT CONFIGURATION ............................................................................................................................ 6 2.2 EUT EXERCISE ........................................................................................................................................ 6 2.3 GENERAL TECHNICAL REQUIREMENTS............................................................................................. 6 2.4 CONFIGURATION OF TESTED SYSTEM ............................................................................................. 6 3. SUMMARY OF TEST RESULTS .................................................................................... 7 4. DESCRIPTION OF TEST MODES .................................................................................. 8 5. FREQUENCY TOLERANCE ........................................................................................... 9 5.1 PROVISIONS APPLICABLE .................................................................................................................... 9 5.2 MEASUREMENT PROCEDURE .............................................................................................................. 9 5.3 TEST SETUP BLOCK DIAGRAM .......................................................................................................... 10 5.4 TEST EQUIPMENT USED ..................................................................................................................... 10 5.5 TEST RESULT ........................................................................................................................................ 10 6. EMISSION BANDWIDTH .............................................................................................. 13 6.1 PROVISIONS APPLICABLE .................................................................................................................. 13 6.2 MEASUREMENT PROCEDURE ............................................................................................................ 13 6.3 TEST SETUP BLOCK DIAGRAM .......................................................................................................... 13 6.4 MEASUREMENT EQUIPMENT USED: ................................................................................................. 13 6.5 MEASUREMENT RESULT: .................................................................................................................... 14 7. UNWANTED RADIATION ............................................................................................. 15 7.1 PROVISIONS APPLICABLE .................................................................................................................. 15 7.2 MEASUREMENT PROCEDURE ............................................................................................................ 15 7.3 TEST SETUP BLOCK DIAGRAM .......................................................................................................... 16 7.4 MEASUREMENT EQUIPMENT USED: ............................…

Text truncated - open the document above for the full version.

Test Setup Photos

RADIATED TEST SETUP

Contact Information

Applicant

LouisBond Wu(General Manager)
[email protected]595-28012708Fax: 595-28013708

Test Firm

Attestation of Global Compliance Shenzhen Co. Ltd.Forrest Lei
[email protected]86-755-29081966Fax: 86-755-26008484

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
29406.1 MHz - 470 MHz3.65 W7K30F3E1.14 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. This transmitter may operate with the antenna(s) documented in this filing in Push-to-Talk and body-worn configurations. RF exposure compliance is limited to the specific belt-clip and accessory configurations as documented in this filing and the separation distance between user and the device or its antenna shall be at least 2.5 cm. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. The highest reported SAR values are Head 3.38 W/kg, Body-worn 4.26 W/kg when operating at 50% duty cycle.