Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USB wireless monitor & controller User’s Manual SCIE-OM-01 Copyright@2006 Chongqing Jinshan Science & Technology (Group) Co., Ltd Page 1 of 30 Statement: Copyright: This manual is protected by the copyright of Chongqing Jinshan Science and Technology (Group) Co. Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language or computer language, in any form or by any means, electronic mechanical, magnetic, optical, chemical, manual or otherwise, without prior written permission. Trademark: is the registered trademark of Chongqing Jinshan Science and Technology (Group) Co. Ltd. This trademark only belongs to the company’s product of Gastrointestinal Wireless Capsule Endoscope System. Trademark of the third party: ● Microsoft and Windows are the trademarks or registered trademarks of Microsoft Corporation in America and other countries. ● Pentium and Celeron are the trademarks or registered trademarks of Intel Corporation. ● In addition, the names of systems and products in this manual usually are the trademarks or registered trademarks of their respective developers and manufacturers. Authorization: ● Chongqing Jinshan Science and Technology (Group) Co. Ltd. implements protection of authorization on all rational designs and every part of production of Gastrointestinal Wireless Capsule Endoscope System. ● Any party or individual shall not lend, transfer or transact the product in any form, without authorization of the company. ● Should the product be used without authorization of the company, so the company shall not be responsible for any consequences caused by it. ● The manufacturer shall not be responsible for any consequences caused by deliberate damage or incorrect operation on direct or indirect use of Gastrointestinal Wireless Capsule Endoscope System. ● Within the scope of protection of authorization, the company can make adjustment for design and production of the system at any time without Page 2 of 30 Copyright@2006 Chongqing Jinshan Science & Technology (Group) Co., Ltd. notice. ● The image workstation in the Gastrointestinal Wireless Capsule Endoscope System operates under the Microsoft Windows XP Professional SP2 and its upgrade version. Any content in this environment does not belong to the scope of the company’s authorization; therefore, the company is not liable for any tort involved in using of the operating environment. Software authorization: ● Any party and individual shall not amend or copy all and part of the product without authorization. ● All termination of authorization is regarded as unauthorized. All information within the term of authorization shall be destroyed and dealt with in time, or it will be considered as tort. Approval: The Gastrointestinal Wireless Capsule Endoscope System conforms to the SFDA Authentication of State Food and Drug Administration of the People’s Republic of China. Environmental protection: ● Since capsule contains battery, corresponding treatment shall be made according to the local environment protection law after used, to avoid environment pollution. ● As to waste disposal of recorder in Gastrointestinal Wireless Capsule Endoscope System, please see the regulations of local electric product retirement for reference and corresponding treatment. This manual is subject to change without notice. This manual is for the USB wireless monitor of Gastrointestinal Wireless Capsule Endoscope System (hereafter called “OMOM Capsule Endoscopy”),which is the complement user manual of the 《Gastrointestinal Wireless Capsule Endoscope System》 Copyright@2006 Chongqing Jinshan Science & Technology (Group) Co., Ltd Page 3 of 30 Contact Manufactured by: Chongqing Jinshan Science & Technology (Group) Co., Ltd. Add:NO. 18, Nishang Road, LiangLu Industrial City YuBei District,chongqing,P.R.china P.C: 401120 Tel: +86-23-86098111 +86-10-58701253 +86-10-58701254 Company: http://www.cqjs.net Product: http://www.omom.us Email: Domestic sales: [email protected] Domestic technical support: [email protected] International sales: [email protected] International technical support: [email protected] Authorized European Representative: Smart Medical Group SL ADD.:Polígono Industrial Cordovilla Calle D N O 1 31191 Cordovilla Navarra - Spain Tel.:+34 948 29 33 24 Fax.:+34 948 29 34 18 [email protected] www.smartmedicalgroup.com Page 4 of 30 Copyright@2006 Chongqing Jinshan Science & Technology (Group) Co., Ltd. Special Mark Description: :Notice: Instruct user operating correctly to avoid the operation failed. :Hint: Un-ideal but rational result description, or rational suggestion and description. :Warning: Prompt for prohibiting operation that will bring serious consequence or destroy equipment. :caution:US Federal Law restricts this device ti sale by or on the order of a physician. Copyright@2006 Chongqing Jinshan Science & Technology (Group) Co., Ltd Page 5 of 30 SAFETY ALERT DESCRIPTIONS The following is a list of Capsule Endoscope System safety alerts that appear in this section and throughout this manual. You must read, understand, and heed these safety alerts before attempting to operate the Capsule Endoscope System. CAUTION: The Capsule cannot be chewed by the patient and should be swallowed under the doctor’s supervision. CAUTION: The Capsule is disposable. CAUTION: The disposal of used products should be complied with the national laws/regulations. CAUTION: The recorder should be worn outside of the clothing, or hurts of skin could occur. CAUTION: The charger should not be used in the patient environment. The device cannot be operated while charging. CAUTION: SIP/SOP only be connected the equipment in situations where no risk of external voltage exists. EMC ALERT DESCRIPTIONS The following is a list of Capsule Endoscope System EMC alerts that appear in this section and throughout this manual. You must read, understand, and heed these EMC alerts befo…
Text truncated - open the document above for the full version.
EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT – Front View EUT – Rear View
EXHIBIT A - FCC ID LABELING AND LOCATION FCC ID Label FCC ID Label Location
Antenna EXHIBIT C - EUT INTERNAL PHOTOGRAPHS EUT – Cover off View EUT – Main Board Top View EUT – Main Board Bottom View
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP*, NIST, or any agency of the Federal Government. * This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “*” (Rev.2) FCC PART 15.249 MEASUREMENT AND TEST REPORT For Chongqing Jinshan Science & Technology (Group) Co., Ltd. No.18, Nishang Road, LiangLu Industrial City, Yubei District, Chongqing, P.R. China FCC ID: XE8CJSMEW-II Model: JS-MEW-II Report Type: Original Report Product Type: USB Wireless Monitor & Controller Test Engineer: Weir Zhong Report Number: RSC09121451 Report Date: 2010-01-22 Reviewed By: Merry Zhao EMC Engineer Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Chongqing Jinshan Science & Technology (Group) Co., Ltd. FCC ID: XE8CJSMEW-II Report No.: RSC09121451 Page 2 of 25 FCC Part 15.249 Test Report TABLE OF CONTENTS GENERAL INFORMATION.......................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4 OBJECTIVE...................................................................................................................................................................4 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................4 TEST METHODOLOGY..................................................................................................................................................5 TEST FACILITY.............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ..........................................................................................................................6 JUSTIFICATION.............................................................................................................................................................6 EQUIPMENT MODIFICATIONS.......................................................................................................................................6 LOCAL SUPPORT EQUIPMENT LIST AND DETAILS........................................................................................................6 EXTERNAL I/O CABLE..................................................................................................................................................6 CONFIGURATION OF TEST SETUP.................................................................................................................................6 BLOCK DIAGRAM OF TEST SETUP................................................................................................................................7 SUMMARY OF TEST RESULTS...............................................................................................................................8 FCC §15.203 - ANTENNA REQUIREMENT.............................................................................................................9 APPLICABLE STANDARD..............................................................................................................................................9 ANTENNA CONNECTOR CONSTRUCTION......................................................................................................................9 FCC §15.207 (A) - CONDUCTED EMISSIONS......................................................................................................10 APPLICABLE STANDARD............................................................................................................................................10 MEASUREMENT UNCERTAINTY..................................................................................................................................10 EUT SETUP................................................................................................................................................................10 EMI TEST RECEIVER SETUP.......................................................................................................................................11 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................11 TEST PROCEDURE......................................................................................................................................................11 TEST RESULTS SUMMARY..........................................................................................................................................11 TEST DATA................................................................................................................................................................11 FCC §15.205, §15.209, §15.109 & §15.249 - RADIATED EMISSIONS .................................................................14 APPLICABLE STANDARD............................................................................................................................................14 MEASUREMENT UNCERTAINTY..................................................................................................................................14 TEST EQUIPMENT SETUP..................................................................................................…
Text truncated - open the document above for the full version.
EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Radiated Emissions - Front View Radiated Emissions - Rear View
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.45 GHz - 2.47 GHz | - |

Smart Capsule (in-body transmitter)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless CF Card
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified