
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
megascan M1 User Manual Rev. 1.0 Updated on 28th August, 2009 Technical Contacts and Enquiry: [email protected] Website: www.scanmega.com (This user manual / product specification is subjected to be changed without prior notice) P. 1 megascan M1 User Manual Rev. 1.0 Model: megascan M1 megascan M1 User Manual Rev. 1.0 Updated on 28th August, 2009 Technical Contacts and Enquiry: [email protected] Website: www.scanmega.com (This user manual / product specification is subjected to be changed without prior notice) P. 2 Table of Content FCC statement..................................................................................................... 3 CE statement ....................................................................................................... 3 Chapter 1 Introduction of megascan M1 ........................................................... 4 1.1 Overview of megascan M1 ................................................................ 4 1.2 Ports Description ................................................................................ 5 1.3 Indicators LEDs in megascan M1 ..................................................... 6 1.4 Antenna for megascan M1 ................................................................ 7 1.5 Product Features ................................................................................ 8 1.6 Specification: ....................................................................................... 9 Chapter 2 Installation of megascan M1 ........................................................... 10 2.1 Power up megascan M1 .................................................................. 10 2.2 Environmental Requirements .......................................................... 10 2.3 Start up Procedures ......................................................................... 11 2.4 Caution .............................................................................................. 11 2.5 Professional Installation Instructions .............................................. 12 Chapter 3 Demonstration of RFID Applications ............................................. 15 3.1 Creating RFID Application with megascan M1 .............................. 15 3.1.1 Delivering Application to megascan M1 ................................... 15 3.1.2 Programming Language compatibility ...................................... 15 Chapter 4 Regulatory Information ................................................................... 16 4.1 Federal Communications Commission (FCC) Compliance .......... 16 4.1.1 Radio Frequency Radiation Exposure ....................................... 17 4.2 CE Compliance ................................................................................. 18 Chapter 5 Disclaimer Notice ............................................................................ 19 Chapter 6 Warranty ........................................................................................... 20 Chapter 7 Support ............................................................................................. 21 megascan M1 User Manual Rev. 1.0 Updated on 28th August, 2009 Technical Contacts and Enquiry: [email protected] Website: www.scanmega.com (This user manual / product specification is subjected to be changed without prior notice) P. 3 FCC statement FCC NOTICE: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. CE statement CE NOTICE: The CE Mark applies to products regulated by certain European health, safety and environmental protection legislation. The CE Mark is obligatory for products it applies to: the manufacturer affixes the marking in order to be allowed to sell his product in the European market. megascan M1 User Manual Rev. 1.0 Updated on 28th August, 2009 Technical Contacts and Enquiry: [email protected] Website: www.scanmega.com (This user manual / product specification is subjected to be changed without prior notice) P. 4 Chapter 1 Introduction of megascan M1 1.1 Overview of megascan M1 The Megabyte Ltd., megascan M1 RFID reader does more than simply read and acts as a data conduit, they need processing speed and ample memory. is an UHF RFID reader, which includes powerful RFID reader with 17 RFID antenna ports, which operates in 860MHz to 930MHz UHF band and is compliance with ISO 18000-6C Tag Air Interfaces with read and write function. megascan M1 reduces implementation cost and deployment time; improves reliability in harsh environments and enhances overall RFID system performance. β’ The megascan M1 Intelligent RFID Reader supports protocols, UHF CLASS 1 GEN2 EPC C1G2/ISO 18000-6C, (865-868 MHz RFID frequency band) in Europe as well as (902-928 MHz RFID frequency band) in United States. megascan M1 User Manual Rev. 1.0 Updated on 28th August, 2009 Technical Contacts and Enquiry: [email protected] Website: www.scanmega.com (This user manual / product specification is subjected to be changed without prior notice) P. 5 1.2 Ports Description The megascan M1 has several types of input/output port: Items Name Description 1 Ethernet Port, RJ-45 10BaseTx/100BaseTx port that connects the reader to your Ethernet network, which is embedded with Power over Ethernet (PoE) Technology. 2 UHF RFID Antenna Port(s) 17 SMA ports for external UHF antenna connection; -16 ports with LED signal light, - 1 dedicate RF output ports for M2 connection, megascan M1 User Manual Rev. 1.0 Updated on 28th August, 2009 Technical Contacts and Enquiry: [email protected] Website: www.scanmega.com (This user manual / product specification is subjected to be changed without prior notice) P. β¦
Text truncated - open the document above for the full version.
(Fig.1) FCC ID: XEK-MEGASCANM1 FCC LABEL LOCATION The label will be permanently affixed at a conspicuous location on the device. LABEL
β’Black and White format Model: megascan M1 Tested to comply with FCC Standards 3β Product label 2β FCC ID: XEK-MEGASCANM1 S/N: 000000000001 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
INTERTEK TESTING SERVICES FCC ID: XEK-MEGASCANM1 RF exposure page 1 of 1 For Maximum Permissible Exposure (MPE) evaluation of the device, the maximum power density at 25 cm from this mobile transmitter shall be less than the General Population / Uncontrolled MPE limit in OET Bulletin 65. For the device of tested model of M1, the maximum conducted measured power (P out ) was 912mW. From these data, the exposed power density at a distance (R) of 25cm from the center of radiation of the antenna can be calculated according to OET Bulletin 65 as follow: Power density = PG / 4ΟR 2 where: P= Power input to the external antenna (P out β cable loss) G= Antenna Gain (Linear gain) R= Separation distance from Transmitting Antenna The conducted power P out = 29.6dBm Cable loss = 0.5dB Antenna Gain = 6dB The power density at 25 cm from the antenna = (812.830 x 3.98)/ (4Ο25 2 ) mW cm-2 = 0.412 mW cm-2 In the frequency range of 902-928 MHz, the MPE limit is 0.601 mWcm-2 for general population and uncontrolled exposure. As the measured power density at 25cm from the transmitter is lower than the MPE limit, the compliance to the MPE limit can be ensured by indicating the minimum 25cm separation between the transmitter's radiating structures and body of the user or nearby persons. The following RF exposure statement is included in the user manual: βFCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 25 centimeters between the radiator and your body.β
INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H2A INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H2B INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H2C INTERTEK TESTING SERVICES Report No.: HK09050175- 3 H3A INTERTEK TESTING SERVICES Report No.: HK09050175- 3 H3B INTERTEK TESTING SERVICES Report No.: HK09050175- 3 H3C INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H4 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H5 A INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H5 B INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6A.1 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 . H6A.2 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6B.1 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6B.2 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6C.1 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6C.2 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6D.1 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6D.2
INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6A.1 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 . H6A.2 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6B.1 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6B.2 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6C.1 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6C.2 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6D.1 INTERTEK TESTING SERVICES Report No.: HK09050758- 3 H6D.2
INTERTEK TESTING SERVICE Report No: HK09070758-1 Configuration Photographs Worst-Case Radiated Emissions (Front View) Model : M1 INTERTEK TESTING SERVICE Report No: HK09070758-1 Configuration Photographs Worst-Case Radiated Emissions (Back View) Model : M1
81-1 Luliaoken, 9th Lin, Wulung Tsuen Chiunglin Β· Hsinchu Β· Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.75 MHz - 927.25 MHz | 912.00 mW |
mHand-H6B
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
UHF Mobile RFID Reader
Equipment Class
NII - Unlicensed National Information Infrastructure TX
MSCAN-CVG RFID READER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter